Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1. Synchronous generator design & operation Dr.-Ing. Georg Möhlenkamp 1/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1. Synchronous generator design & operation 1. Basics of synchronous generator operation 2. Excitation of synchronous generator 3. Steady state operation of synchronous generator 4. Embodiments of synchronous generators 5. Dynamics of synchronous generator operation 6. Synchronous generator design: Cooling 2/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation 3/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation Voltage induction by rotating exitation coil: I = v(t)ind V Ο ο π£ π‘ 4/66 Institut Energietechnik ind ππΉ = β ππ‘ Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation Voltage induction by rotating exitation coil: v(t) v(t) 5/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp t Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation Voltage induction by rotating exitation coil: π£ π‘ = π β ππ ππ‘+ππ£ π£ π‘ = π β sin ππ‘ + ππ£ t 6/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation 3-phase AC system: vabc(t) t sin ππ‘ + ππ£ π£π (π‘) π£π (π‘) = π β sin ππ‘ + ππ£ β 120° π£π (π‘) sin ππ‘ + ππ£ + 120° 7/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation Main parts of Synchrongenerator β stationary armature machine: Stator winding Stator laminated core Rotor with exitation winding Generator shaft Star connetions of Stator windings 8/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation Coil-axis definition: Rotor axis d Stator axis C Stator axis B Stator axis A d direct axis q quadrature axis Orientation axis Definition acc. Park 9/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation Reduction to 1-phase equivalent circuit: Stator axis A Rotor axis d Rotor axis q d direct axis q quadrature axis Definition acc. Park 10/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.1. Basics of synchronous generator operation 1-phase equivalent circuit: Synchronous generated voltage UP (or VP) Stator voltage US or UG (or VS) Stator current I or IS 11/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator 12/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator Brush rings Cooling fan Main bearing Sealing Excitation Terminals 13/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator 14/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator 15/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator No load diagram: ππ = 1 2 β ΟπΏ β πΏππ β πΌπ = 1 2 β πππ β πΌπ Ldf : mutual inductance stator to exciter If0 excites generator to nominal stator voltage VsN. Short circuit characteristics: ππ 1 πππ πΌπ = = β β πΌπ ππ π 2 π Ifk induces generator nominal stator current IsN. Xd : rotor reactance in d Rd : rotor resistance in d Rd << Xd No-load/Short-circuit ratio kk: πΌπ0 πΌπ π0 ππ π 1 1 = = ππ = β = πΌππ πΌπ π πΌπ π ππ π₯π 16/66 Institut Energietechnik xd : related rotor reactance in d Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator Synchronous impedances: ππ ππ = πΌπ ππ π ππ = πΌπ π0 ππ = ππ 17/66 to calculate from no-load & short circuit characteristics for turbo generators Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator Summary: No-load and short circuit characteristics β’ No-load characteristic: Back EMF over excitation current at open circuit β’ Non-linear voltage curve due to iron saturation β’ Short-circuit characteristics: Stator current over excitation current at short circuit β’ Small resulting air gap flux linkage => no saturation Rotor excitation methods: β’ External with slip rings and brushes β’ Brushless with rotating diode bridges 18/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator 19/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 2. Excitation of synchronous generator 20/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.2. Excitation of synchronous generator Exercise 1.2.1: a) Give for the test results of the Olkiluoto Generator (previous pages) the saturated and the unsaturated reactance in related and absolute values b) Calculate the synchronous generated voltage VP for nominal operating conditions (saturated and unsaturated case) c) Starting from this nominal operating conditions, determine the terminal voltage of the generator, after a sudden disconnection from the grid Beispiel 4.1, S. 85 21/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 100 Uns. β95,6 kV Sat. β83,7 kV 2. Excitation of synchronous generator Exercise 1.2.1c Sudden load shedding β38 kV 22/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady-state operation 23/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator simplified equivalent circuit and vector diagram accordingly: Xd : rotor reactance in d Rd : rotor resistance in d Rd << Xd Ο Phase angle Ο (between stator voltage and current) Load angle Ο (between stator and synchronous generated voltage) 24/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Power (measured at grid): ππΊ = 3 β ππΊ β πΌ β ππΊ = 3 β ππΊ β I β cos π ππΊ = 3 β ππΊ β I β sin π Ο 25/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Power (generated internally): β π π ππΊ = 3 β ππΊ β πΌ β = 3 β ππΊ β βπππ π π ~0 ππβ = ππβ β ππΊβ = ππ π βππ β ππΊ = ππ cos π β πππ sin π β ππΊ ππΊ β ππ ππΊ = 3 β sin π ππ Ο ππΊ β ππ ππΊ2 ππΊ = 3 β cos π β 3 β ππ ππ 26/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator No load operating point: Im PG = QG = 0 I=0 Vp= VG ο¨ Vd = 0 UP UG Re Ο=0 οͺ=0 Active power only operating point (motor): PG >0 ; QG = 0 οͺ= 0 Ο Vp> VG as Vp=VG + Vd Rd << Xd ο¨ I β΄ Vd 27/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Inductive reactive power only: Im PG = 0 ; QG = +Q UP UG Ο Ud Re VP > VG Ο=0 οͺ=-90° I Capacitive reactive power only: PG = 0 ; QG = -Q Im I Ο UP Ud VP < VG Ο=0 οͺ=+90° UG Re 28/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Exercise 1.3.1: Nominal values of a turbo generator: 1600 MVA; 27,0 KV; 50 Hz; cos Ο = 0,800; 1500 rpm; xd= 2,1 p.u.; a) Calculate the torque of the turbine under nominal conditions of the generator b) Show the dependency on the generator active and reactive power of the load angle Ο for nominal excitation conditions c) Calculate for the 2 operating points generator active and reactive power, reactive power consumption (inductive) or supply (capacitive). 1. Starting from the nominal operating point, the valve of the turbine get reduced to 75% of power 2. Starting from the nominal operating point, the excitation current of the generator get reduced to 75% (Valve of turbine not reduced) Beispiel 4.2, S. 93 29/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Load angle Ο (between no-load and actual excitation current) 30/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator 31/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator 32/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Summary: Stator current root locus β’ Cylindrical rotor machine: circle with radius proportional to If (for Rs = 0) β’ Operational limits min./max. exciter current, max stator current, max. load angle, Max. real power, stability limit Not covered: β’ Salient pole machine with βPascal limaconsβ β’ Reluctance circle for zero excitation β’ Regulation and V-curves 33/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Exercise 1.3.2: Nominal values of a turbo generator: 552 MVA; 24,0 KV; 50 Hz; cos Ο = 0,900; 3000 rpm; xd= 1,63 p.u.; a) Draw the voltage vector diagram under nominal conditions of the generator b) Draw the stator current vector diagram for nominal conditions c) By using this diagram: determine if the 2 following operating points are allowed for continuous service 1. Nominal current and cos Ο = 0,8 2. Nominal current and cos Ο = 1,0 d) By using the stator current vector determine the generator active and reactive power, if from nominal operation 1. The steam to the turbine is reduced to 50% 2. The excitation current is reduced resulting in a reduced synchronous generated voltage of 75% Beispiel 4.6, S. 105 34/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.3. Steady state operation of synchronous generator Exercise 1.3.2 (coninued): Nominal values of a turbo generator: 552 MVA; 24,0 KV; 50 Hz; cos Ο = 0,900; 3000 rpm; xd= 1,63 p.u.; e) Starting from nominal conditions the synchronous generated voltage is reduced. 1. At which synchronous generated voltage runs the generator with active power only, and which is the stator current accordingly. 2. At which synchronous generated voltage runs the generator at the stability limit, and which is the stator current accordingly. f) If the machine runs as a synchronous compensator only, which is the maximum reactive power inductive and capacitive? Beispiel 4.6, S. 105 35/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators 36/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators 37/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators 38/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators 39/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators 40/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators Retaining ring Coupling to turbine Cooling fan Rotor, active part Excitation connectors in hollow shaft Slip rings Excitation end windings Slot caps Source: ALSTOM 41/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators Synchronous generator design: turbo rotor 42/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators 43/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.4. Embodiments of synchronous generators 44/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation 45/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Windings and equivalent circuits of a synchronous generator: U, V, W: Stator windings f: excitation winding D, Q: Damper windings d, q: equivalent windings to represent stator windings in d, q axes 46/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Interpretation of synchronous impedances: ππ ππ = πΌπ see chapter 2 ππ π ππ = πΌπ π0 to calculate from noload & short circuit characteristics ππ = ππ 47/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp for turbo generators Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation What happens at 3 phase short circuit: Phase current and excitation current at short circuit in voltage zero crossing Short at voltage zero crossing: ο§ max. DC component in AC current, ο§ max. stator flux => through flux linkage max. rotor current (in field and damper winding), ο§ stator flux is frozen due to no stator voltage => rotor turns below stator flux and AC is induced in excitation and damper winding, 48/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Interpretation of sub-synchronous impedances: with Assuming Damper winding in d-axis not operative: 49/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Roughly size inductances and resistances: Reactance Turbo generators Salient pole generators Rule of thump for Turbo-Generators: 50/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Current and voltage (related to nominal values) at 3 phase short circuit: Short circuit in voltage zero crossing (left) and voltage maximum (right) Short at voltage zero crossing: max. DC component in AC current Short at voltage maximum: no DC component in AC current 51/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Analysis of short circuit currents: Envelope of AC (left) and DC component (right) of short circuit current 3 characteristic initial values (Ig, Ik´, Ik´´) and time constants (Tg, Td´, Td´´) to describe the short circuit current characteristic 52/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Characteristic parameters to describe short circuit currents: πΌπ = ππ ππ πΌπ ´ = ´´ πΌπ = 53/66 Steady state short circuit current (see chapter 2) ππ ´ ππ ´ ππ ´´ ππ ´´ Transient short circuit current (UP´ calculated under the assumption that Xd´ replaces Xd just before the short) Initial AC short circuit current (UP´´ calculated under the assumption that Xd´´ replaces Xd just before the short) Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Roughly size of time constants: Time constants 54/66 Turbo generators Institut Energietechnik Salient pole generators Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Generator voltage (related to nominal values) at load shedding: Load shedding without voltage control (left) and fast voltage control (right) w/o voltage control: Vf const.; VS rise continuously, with voltage control: Vf = 0; VS returns fast to nominal value 55/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Generator voltage (related to nominal values) at load shedding after 3-phase short: Excitation current and voltage, stator voltage, (all related values) 3-phase short: excitation control tries to recover shorted voltage (Vf = 2); Load shedding: voltage comes back quickly and supports house load 56/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.5. Dynamics of synchronous generator operation Exercise 1.5.1: Nominal values of a turbo generator: (see exercise 1.3) 1600 MVA; 27,0 KV; 50 Hz; cos Ο = 0,800; 1500 rpm; xd= 2,1 p.u.; 1. What happens with the generator active, reactive power (inductive or capacitive) and speed, starting from the operating point under nominal conditions, 1. If the steam supply to the turbine get stopped 2. If the excitation circuit get broken and excitation current stops immediately 3. If a 3-phase short happens at the generator terminals 4. If the generator suddenly gets disconnected from the grid 5. If a 3-phase short happens at the generator terminals and, as a result, short time later, the generator suddenly gets disconnected from the grid Beispiel 4.2, S. 93 57/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.6. Cooling 58/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.6. Synchronous generator design: Cooling 59/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.6. Synchronous generator design: Cooling 60/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.6. Synchronous generator design: Cooling 61/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.6. Synchronous generator design: Cooling 62/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.6. Synchronous generator design: Cooling 63/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1.6. Synchronous generator design: Cooling 64/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme Brandenburgische Technische Universität Cottbus - Senftenberg Generators and Large Drives 1. State of the art synchronous generator design 65/66 Institut Energietechnik Dr.-Ing. Georg Möhlenkamp Lehrstuhl Leistungselektronik und Antriebssysteme
© Copyright 2025 ExpyDoc