STLP 9128 E special

STLP 9128 E special
STLP 9128 E special - Gestockte Breitband Log.-Per. Antenne
STLP 9128 E special - Stacked Log Periodic Antenna
Technische Daten:
Frequenzbereich, nominell:
Nutzbarer Frequenzbereich:
Impedanz, nominell:
Stehwellenverhältnis SWR typisch:
Befestigung:
3 dB Öffnungswinkel typ.(E-Ebene):
3 dB Öffnungswinkel typ.(H-Ebene):
Max. Eingangsleistung (N-Buchse):
Max. Eingangsleistung
(7/16-Buchse):
Halterungsrohr:
Breite x Länge x Höhe
bei vertikaler Polarisation:
Gewicht:
Datasheet
Type:
The STLP 9128 E special is a linear polarized stacked logarithmic periodic broadband antenna with N- or 7/16-connector for
receive and transmit applications. Main
application: generation of defined high field
strength levels for radiated immunity testing.
80-1700 MHz
80-2700 MHz
50 Ω
<1.5
22 mm Rohr / Tube
47°-87°
41°-107°
1 kW (const.)
1.5 kW (intermitt.)
2 kW (const.)
3 kW (intermitt.)
d=22 mm
1.5 x 1.74 x 1.4 m
9.8 kg
1/10
Specifications:
Nominal frequency range:
Usable frequency range:
Nominal Impedance:
Standing Wave Ratio SWR typical:
Mounting
3 dB beam width typ.(E-Plane):
3 dB beam width typ.(H-Plane):
Max. input power (N-connector):
Max. input power (7/16Connector):
Mounting tube:
Width x length x height
while set to vertical polarisation:
Weight:
Rev. A
0741.171115
Bauart:
Die STLP 9128 E special ist eine linear polarisierte, gestockte Logarithmisch Periodische
Breitbandantenne mit N- oder 7/16- Anschluss,
Aluminiumausführung für Empfangs- und Sendeanwendungen. Haupteinsatzzweck: Erzeugung extrem hoher Feldstärken.
STLP 9128 E special
Description:
The STLP 9128 E special is nearly identical
like the STLP 9128 E but with folded longest elements and smaller structure angle.
Beschreibung:
Die STLP 9128 E special ist ähnlich der STLP
9128 E, jedoch verfügt die STLP 9128 E special
über einen verringerten Strukturwinkel und gefaltete Elemente. Dadurch verringert sich die
Antennengröße auf < 150 cm.
Die gestockte Logarithmisch Periodische Breitbandantenne besteht aus zwei übereinander
angeordneten logarithmisch-periodischen Strukturen. Die hervorragenden Eigenschaften (breitbandig sehr gute Anpassung, gleichmäßiger
Gewinn über den gesamten Frequenzbereich)
der Logarithmisch Periodischen Antennen bleiben dabei voll erhalten. Durch die gestockte
Anordnung wird das Richtdiagramm in der HEbene besser gebündelt, was zu einem Gewinnzuwachs von 2.5 dB gegenüber der herkömmlichen LP-Antenne führt. Dies ist insbesondere bei der Immunitätsprüfung ein wesentlicher Vorteil, wenn maximale Feldstärke bei großer Feldhomogenität erreicht werden soll. Nahezu gleiche Öffnungswinkel in E- und H-Ebene
sorgen für optimale "Ausleuchtung" bei minimiertem Einfluss von Umgebungsreflexionen.
Darüber hinaus verfügt die STLP 9128 E special
über eine hervorragende Unterdrückung der
kreuzpolarisierten Komponente. Durch die Verwendung von Schnelltrennstellen (Fastlinks)
kann die Antenne werkzeuglos innerhalb kürzester Zeit in fünf kompakte Einzelteile zerlegt werden, die leicht gelagert bzw. transportiert werden
können.
Datasheet
2/10
Rev. A
0741.171115
The stacked Log Periodic Dipole Antenna
(Stacked LPDA) consists of two ordinary
Log.-Per. structures. The excellent characteristics (flat gain over a large bandwidth,
low SWR) of the ordinary LPDA designs
could be maintained using the stacked
LPDA design. The stacked design helps to
focus the directional pattern of the H-plane
somewhat, resulting in a typical gain improvement of 2.5 dB compared to an ordinary LP antenna. This is especially important for immunity testing, where a maximum fieldstrength and a good field uniformity is required. The beamwidth in the Eplane and the H-plane are nearly identical,
providing an optimised illumination of the
EuT with minimised ground reflection influence.Further the cross polar rejection of the
STLP 9128 E special is excellent. The
fastlinks allows to disassemble the rear
elements without any need for further tools
within a few seconds. These fastlinks divide
the antenna into five parts, which can be
stored and transported easily.
STLP 9128 E special
Isotropgewinn
10
9
8
Isotropic Gain [dBi]
7
6
5
4
3
2
1
0
500
1000
1500
Frequency [MHz]
2000
2500
2000
2500
Antennen-Wandlungsmaß
35
30
20
15
10
5
0
500
Datasheet
1000
1500
Frequency [MHz]
3/10
Rev. A
0741.171115
Antenna Factor [dB/m]
25
STLP 9128 E special
Distance
Abstand
MHz
60.00
65.00
70.00
75.00
80.00
85.00
90.00
95.00
100.00
105.00
110.00
115.00
120.00
125.00
130.00
135.00
140.00
145.00
150.00
155.00
160.00
165.00
170.00
175.00
180.00
185.00
190.00
195.00
200.00
205.00
210.00
215.00
220.00
225.00
230.00
235.00
240.00
245.00
250.00
255.00
260.00
265.00
270.00
275.00
280.00
285.00
290.00
295.00
300.00
305.00
310.00
m
6.40
6.40
6.40
6.40
6.40
6.19
6.01
5.85
5.70
5.57
5.45
5.34
5.24
5.14
5.06
4.98
4.90
4.83
4.77
4.71
4.65
4.60
4.55
4.50
4.46
4.42
4.38
4.34
4.30
4.27
4.24
4.21
4.18
4.15
4.12
4.10
4.07
4.05
4.02
4.00
3.98
3.96
3.94
3.92
3.90
3.89
3.87
3.85
3.84
3.82
3.81
Datasheet
Wavelength
Wellenlänge
m
5.00
4.62
4.29
4.00
3.75
3.53
3.33
3.16
3.00
2.86
2.73
2.61
2.50
2.40
2.31
2.22
2.14
2.07
2.00
1.94
1.88
1.82
1.76
1.71
1.67
1.62
1.58
1.54
1.50
1.46
1.43
1.40
1.36
1.33
1.30
1.28
1.25
1.22
1.20
1.18
1.15
1.13
1.11
1.09
1.07
1.05
1.03
1.02
1.00
0.98
0.97
Attenuation
Dämpfung
dB
23.95
20.92
17.23
14.73
13.53
13.39
12.93
12.68
12.94
12.44
11.69
11.14
10.86
10.66
10.58
10.91
11.45
12.00
12.33
12.45
12.64
12.67
12.59
12.65
12.77
12.73
13.02
13.47
13.60
13.77
13.77
13.57
13.51
13.54
13.58
13.45
13.74
13.95
14.00
13.94
14.22
14.60
14.76
15.10
15.62
16.17
16.79
16.80
16.59
16.64
16.58
4/10
Gain(Isotr.)
Isotrop- gewinn
dBi
0.09
1.95
4.12
5.67
6.55
6.74
7.09
7.33
7.31
7.67
8.15
8.53
8.77
8.97
9.11
9.04
8.86
8.68
8.60
8.63
8.62
8.69
8.81
8.86
8.88
8.98
8.91
8.76
8.77
8.76
8.83
9.00
9.10
9.15
9.20
9.33
9.25
9.21
9.25
9.34
9.26
9.13
9.11
9.00
8.80
8.58
8.33
8.38
8.54
8.57
8.65
Gain(Dipole)
Gewinn über
Dipol
dBd
-2.06
-0.20
1.97
3.52
4.40
4.59
4.94
5.18
5.16
5.52
6.00
6.38
6.62
6.82
6.96
6.89
6.71
6.53
6.45
6.48
6.47
6.54
6.66
6.71
6.73
6.83
6.76
6.61
6.62
6.61
6.68
6.85
6.95
7.00
7.05
7.18
7.10
7.06
7.10
7.19
7.11
6.98
6.96
6.85
6.65
6.43
6.18
6.23
6.39
6.42
6.50
Ant.-Factor
Ant.-Wandlungsmaß
dB/m
5.69
4.53
3.00
2.05
1.73
2.07
2.21
2.44
2.91
2.97
2.90
2.90
3.03
3.19
3.39
3.79
4.28
4.77
5.14
5.40
5.68
5.88
6.02
6.22
6.45
6.58
6.89
7.26
7.47
7.70
7.83
7.87
7.97
8.11
8.25
8.31
8.57
8.79
8.93
9.01
9.26
9.55
9.74
10.01
10.36
10.74
11.14
11.24
11.22
11.34
11.40
Rev. A
0741.171115
Frequency
Frequenz
STLP 9128 E special
Distance
Abstand
MHz
315.00
320.00
325.00
330.00
335.00
340.00
345.00
350.00
355.00
360.00
365.00
370.00
375.00
380.00
385.00
390.00
395.00
400.00
405.00
410.00
415.00
420.00
425.00
430.00
435.00
440.00
445.00
450.00
455.00
460.00
465.00
470.00
475.00
480.00
485.00
490.00
495.00
500.00
510.00
520.00
530.00
540.00
550.00
560.00
570.00
580.00
590.00
600.00
610.00
620.00
630.00
640.00
m
3.79
3.78
3.77
3.75
3.74
3.73
3.72
3.71
3.69
3.68
3.67
3.66
3.65
3.64
3.63
3.62
3.61
3.61
3.60
3.59
3.58
3.57
3.56
3.56
3.55
3.54
3.53
3.53
3.52
3.51
3.51
3.50
3.50
3.49
3.48
3.48
3.47
3.47
3.45
3.44
3.43
3.42
3.41
3.41
3.40
3.39
3.38
3.37
3.36
3.36
3.35
3.34
Datasheet
Wavelength
Wellenlänge
m
0.95
0.94
0.92
0.91
0.90
0.88
0.87
0.86
0.85
0.83
0.82
0.81
0.80
0.79
0.78
0.77
0.76
0.75
0.74
0.73
0.72
0.71
0.71
0.70
0.69
0.68
0.67
0.67
0.66
0.65
0.65
0.64
0.63
0.63
0.62
0.61
0.61
0.60
0.59
0.58
0.57
0.56
0.55
0.54
0.53
0.52
0.51
0.50
0.49
0.48
0.48
0.47
Attenuation
Dämpfung
dB
16.15
16.43
16.44
16.28
16.22
16.32
16.20
16.46
16.56
16.79
16.87
16.78
16.75
17.28
17.42
17.11
16.93
17.14
17.17
17.02
16.96
17.27
17.61
17.47
17.55
17.82
18.06
18.20
18.52
18.51
18.53
18.75
18.91
18.92
18.96
18.95
18.76
18.64
19.02
19.14
19.68
20.10
20.50
20.05
20.16
19.83
20.06
20.76
20.91
21.43
21.07
20.89
5/10
Gain(Isotr.)
Isotrop- gewinn
dBi
8.92
8.83
8.88
9.01
9.09
9.09
9.20
9.12
9.12
9.05
9.06
9.15
9.21
8.99
8.97
9.17
9.30
9.24
9.27
9.39
9.46
9.35
9.22
9.33
9.33
9.24
9.16
9.13
9.01
9.05
9.08
9.01
8.97
9.00
9.02
9.06
9.19
9.29
9.17
9.18
8.98
8.84
8.71
9.00
9.01
9.24
9.19
8.90
8.89
8.69
8.93
9.08
Gain(Dipole)
Gewinn über
Dipol
dBd
6.77
6.68
6.73
6.86
6.94
6.94
7.05
6.97
6.97
6.90
6.91
7.00
7.06
6.84
6.82
7.02
7.15
7.09
7.12
7.24
7.31
7.20
7.07
7.18
7.18
7.09
7.01
6.98
6.86
6.90
6.93
6.86
6.82
6.85
6.87
6.91
7.04
7.14
7.02
7.03
6.83
6.69
6.56
6.85
6.86
7.09
7.04
6.75
6.74
6.54
6.78
6.93
Ant.-Factor
Ant.-Wandlungsmaß
dB/m
11.27
11.49
11.58
11.58
11.63
11.76
11.78
11.98
12.10
12.30
12.41
12.43
12.49
12.83
12.96
12.87
12.85
13.02
13.10
13.09
13.12
13.33
13.57
13.56
13.66
13.85
14.03
14.15
14.37
14.43
14.49
14.65
14.78
14.84
14.91
14.96
14.92
14.91
15.20
15.36
15.73
16.03
16.32
16.18
16.33
16.25
16.45
16.88
17.04
17.38
17.28
17.26
Rev. A
0741.171115
Frequency
Frequenz
STLP 9128 E special
Distance
Abstand
MHz
650.00
660.00
670.00
680.00
690.00
700.00
710.00
720.00
730.00
740.00
750.00
760.00
770.00
780.00
790.00
800.00
810.00
820.00
830.00
840.00
850.00
860.00
870.00
880.00
890.00
900.00
910.00
920.00
930.00
940.00
950.00
960.00
970.00
980.00
990.00
1000.00
1020.00
1040.00
1060.00
1080.00
1100.00
1120.00
1140.00
1160.00
1180.00
1200.00
1220.00
1240.00
1260.00
1280.00
1300.00
1320.00
m
3.34
3.33
3.32
3.32
3.31
3.31
3.30
3.29
3.29
3.28
3.28
3.27
3.27
3.27
3.26
3.26
3.25
3.25
3.24
3.24
3.24
3.23
3.23
3.22
3.22
3.22
3.21
3.21
3.21
3.20
3.20
3.20
3.19
3.19
3.19
3.19
3.18
3.18
3.17
3.17
3.16
3.16
3.15
3.15
3.14
3.14
3.14
3.13
3.13
3.13
3.12
3.12
Datasheet
Wavelength
Wellenlänge
m
0.46
0.45
0.45
0.44
0.43
0.43
0.42
0.42
0.41
0.41
0.40
0.39
0.39
0.38
0.38
0.38
0.37
0.37
0.36
0.36
0.35
0.35
0.34
0.34
0.34
0.33
0.33
0.33
0.32
0.32
0.32
0.31
0.31
0.31
0.30
0.30
0.29
0.29
0.28
0.28
0.27
0.27
0.26
0.26
0.25
0.25
0.25
0.24
0.24
0.23
0.23
0.23
Attenuation
Dämpfung
dB
20.53
20.72
20.58
20.63
21.16
21.65
22.12
22.31
22.15
21.98
21.62
20.92
21.24
22.00
22.06
22.24
22.67
22.59
22.38
22.14
22.15
22.46
22.91
23.00
22.93
22.98
22.88
23.05
23.01
23.38
23.86
24.38
24.33
24.05
23.91
23.99
23.84
24.26
24.11
24.54
25.05
25.71
25.71
25.63
25.43
25.28
25.38
25.99
26.36
26.16
25.75
25.73
6/10
Gain(Isotr.)
Isotrop- gewinn
dBi
9.32
9.28
9.41
9.44
9.23
9.04
8.86
8.82
8.95
9.09
9.32
9.72
9.61
9.28
9.30
9.26
9.09
9.18
9.33
9.50
9.54
9.43
9.25
9.25
9.33
9.35
9.44
9.40
9.46
9.32
9.12
8.90
8.97
9.15
9.26
9.26
9.41
9.28
9.43
9.29
9.11
8.85
8.92
9.03
9.20
9.34
9.36
9.12
9.00
9.16
9.43
9.50
Gain(Dipole)
Gewinn über
Dipol
dBd
7.17
7.13
7.26
7.29
7.08
6.89
6.71
6.67
6.80
6.94
7.17
7.57
7.46
7.13
7.15
7.11
6.94
7.03
7.18
7.35
7.39
7.28
7.10
7.10
7.18
7.20
7.29
7.25
7.31
7.17
6.97
6.75
6.82
7.00
7.11
7.11
7.26
7.13
7.28
7.14
6.96
6.70
6.77
6.88
7.05
7.19
7.21
6.97
6.85
7.01
7.28
7.35
Ant.-Factor
Ant.-Wandlungsmaß
dB/m
17.16
17.33
17.33
17.43
17.77
18.08
18.39
18.55
18.54
18.51
18.40
18.12
18.34
18.78
18.87
19.02
19.30
19.32
19.27
19.21
19.27
19.48
19.76
19.86
19.88
19.95
19.96
20.10
20.13
20.36
20.65
20.97
20.99
20.89
20.87
20.96
20.98
21.28
21.30
21.60
21.94
22.35
22.44
22.48
22.46
22.46
22.59
22.97
23.23
23.20
23.07
23.13
Rev. A
0741.171115
Frequency
Frequenz
STLP 9128 E special
Distance
Abstand
MHz
1340.00
1360.00
1380.00
1400.00
1420.00
1440.00
1460.00
1480.00
1500.00
1520.00
1540.00
1560.00
1580.00
1600.00
1620.00
1640.00
1660.00
1680.00
1700.00
1720.00
1740.00
1760.00
1780.00
1800.00
1820.00
1840.00
1860.00
1880.00
1900.00
1920.00
1940.00
1960.00
1980.00
2000.00
2050.00
2100.00
2150.00
2200.00
2250.00
2300.00
2350.00
2400.00
2450.00
2500.00
2550.00
2600.00
2650.00
2700.00
m
3.12
3.11
3.11
3.11
3.10
3.10
3.10
3.10
3.09
3.09
3.09
3.09
3.08
3.08
3.08
3.08
3.08
3.07
3.07
3.07
3.07
3.07
3.06
3.06
3.06
3.06
3.06
3.06
3.05
3.05
3.05
3.05
3.05
3.05
3.04
3.04
3.04
3.03
3.03
3.03
3.03
3.02
3.02
3.02
3.02
3.01
3.01
3.01
Datasheet
Wavelength
Wellenlänge
m
0.22
0.22
0.22
0.21
0.21
0.21
0.21
0.20
0.20
0.20
0.19
0.19
0.19
0.19
0.19
0.18
0.18
0.18
0.18
0.17
0.17
0.17
0.17
0.17
0.16
0.16
0.16
0.16
0.16
0.16
0.15
0.15
0.15
0.15
0.15
0.14
0.14
0.14
0.13
0.13
0.13
0.13
0.12
0.12
0.12
0.12
0.11
0.11
Attenuation
Dämpfung
dB
25.61
26.59
26.83
26.79
26.52
26.20
26.25
26.96
27.61
27.90
27.93
27.51
27.38
27.24
27.34
27.48
28.14
28.32
28.12
28.55
29.39
30.40
30.98
31.15
31.46
31.83
32.32
32.75
32.93
33.58
33.41
34.15
35.02
35.34
35.02
35.42
34.96
32.85
32.26
31.72
31.26
31.96
32.97
32.64
32.74
33.97
36.06
39.88
7/10
Gain(Isotr.)
Isotrop- gewinn
dBi
9.62
9.19
9.13
9.21
9.40
9.62
9.65
9.35
9.08
8.99
9.03
9.29
9.41
9.53
9.53
9.51
9.23
9.19
9.34
9.17
8.80
8.34
8.10
8.06
7.95
7.81
7.61
7.44
7.39
7.11
7.24
6.91
6.52
6.40
6.66
6.56
6.89
8.04
8.43
8.79
9.11
8.85
8.43
8.68
8.71
8.18
7.21
5.38
Gain(Dipole)
Gewinn über
Dipol
dBd
7.47
7.04
6.98
7.06
7.25
7.47
7.50
7.20
6.93
6.84
6.88
7.14
7.26
7.38
7.38
7.36
7.08
7.04
7.19
7.02
6.65
6.19
5.95
5.91
5.80
5.66
5.46
5.29
5.24
4.96
5.09
4.76
4.37
4.25
4.51
4.41
4.74
5.89
6.28
6.64
6.96
6.70
6.28
6.53
6.56
6.03
5.06
3.23
Ant.-Factor
Ant.-Wandlungsmaß
dB/m
23.14
23.70
23.89
23.93
23.87
23.77
23.86
24.28
24.66
24.87
24.94
24.79
24.78
24.77
24.88
25.01
25.39
25.54
25.49
25.76
26.23
26.79
27.13
27.27
27.47
27.71
28.00
28.26
28.41
28.78
28.74
29.16
29.63
29.84
29.80
30.10
29.98
29.03
28.83
28.66
28.53
28.97
29.57
29.50
29.64
30.34
31.47
33.47
Rev. A
0741.171115
Frequency
Frequenz
STLP 9128 E special
Erzeugung definierter Feldstärken
Generating defined Fieldstrength
Erzeugung von Feldstärken unter Freiraumbedingungen vor der Spitze der Log.-Per.
Antenne (siehe Skizze und Angaben bei
den Kurvenscharen). Wenn Anteile von
Umgebungsreflexionen vorhanden sind,
kann dies zu einer frequenz- und höhenabhängigen Änderung der Feldstärke führen.
Die Leistungsangaben beziehen sich auf
eine 50 Ω Quellimpedanz und unmodulierte
Hochfrequenz (CW). Bei 80% Amplitudenmodulation ist die 1.8-fache Spannungsaussteuerung erforderlich, was in einem ca.
3.24-fachen Leistungsbedarf resultiert. Zur
Steigerung der Feldstärke um den Faktor
10 ist die 100-fache Verstärkerleistung erforderlich.
Field strength generated under freespace conditions at a separation from
the antenna tip (see diagrams for
several combinations of power and
distance). If environmental reflections
are present, this may lead to frequency and height dependent fieldstrengths. The power figures refer to
a 50 Ω source and an unmodulated
(cw) signal. An 80% Amplitude Modulation requires a 1.8 times higher voltage, resulting in 3.24 times higher
power compared to cw. A fieldstrength increase of factor 10 requires
100 times amplifier-power.
Bei der Erzeugung von hohen Feldstärken müssen die relevanten Sicherheitsvorschriften und Normen
beachtet werden! Missachtung dieser Vorschriften kann zu Schädigungen der Gesundheit führen!
The safety precautions and relevant standards must be considered while performing tests
with high fieldstrength! Ignoring these standards and precautions may result in severe
danger for health!
Datasheet
50 %
2.25
+3.5
60 %
2.56
+4.1
70 %
2.89
+4.6
80 %
3.24
+5.1
8/10
90 %
3.61
+5.6
95%
3.8
+5.8
Modulation (AM)
Power Factor
Additional Power
Requirement
[dB]
Rev. A
0741.171115
Modulation (AM)
Leistungsfaktor
Zusätzlicher
Leistungsbedarf
[dB]
STLP 9128 E special
Erzeugte Elektrische Feldstärke vor der Antennenspitze
unmoduliert, Eingangsleistung an N-Buchse, Reflexionsfreie Umgebung
Generated Electrical Fieldstrength in front of Antenna Tip
no modulation, Input Power at N-Connector, Anechoic Environmental Conditions
STLP 9128 E special Erzeugte Feldstärke in 1 m Abstand Spitze - Prüfling
STLP 9128 E special 1 m Distance Tip-EuT
1000
E - Fieldstrength [V/m]
2 kW
1 kW
500 W
200 W
100 W
50 W
100
20 W
10 W
5W
2W
1W
10
1
100
1000
300
3000
Frequency [MHz]
STLP 9128 E special Erzeugte Feldstärke in 2 m Abstand Spitze - Prüfling
STLP 9128 E special 2 m Distance Tip-EuT
E - Fieldstrength [V/m]
1000
2 kW
1 kW
500 W
100
200 W
100 W
50 W
20 W
10 W
5W
10
2W
1W
1
100
300
1000
3000
Datasheet
9/10
Rev. A
0741.171115
Frequency [MHz]
STLP 9128 E special
Erzeugte Elektrische Feldstärke vor der Antennenspitze
unmoduliert, Eingangsleistung an N-Buchse, Reflexionsfreie Umgebung
Generated Electrical Fieldstrength in front of Antenna Tip
no modulation, Input Power at N-Connector, Anechoic Environmental Conditions
STLP 9128 E special Erzeugte Feldstärke in 3 m Abstand Spitze - Prüfling
STLP 9128 E special 3 m Distance Tip-EuT
2 kW
1 kW
500 W
E - Fieldstrength [V/m]
100
200 W
100 W
50 W
20 W
10 W
10
5W
2W
1W
1
100
300
1000
3000
Frequency [MHz]
STLP 9128 E special Erzeugte Feldstärke in 4 m Abstand Spitze - Prüfling
STLP 9128 E special 4 m Distance Tip-EuT
2 kW
E - Fieldstrength [V/m]
100
1 kW
500 W
200 W
100 W
50 W
20 W
10 W
10
5W
2W
1W
1
100
300
1000
3000
Frequency [MHz]
Datasheet
10/10
Rev. A
0741.171115
SCHWARZBECK MESS – ELEKTRONIK OHG
An der Klinge 29
69250 Schönau, Germany
Phone: +49 6228 1001
Fax.: +49 6228 1003
E-Mail: [email protected]