43LED/545 Wiring diagram DMX512 Decoder (Easy) 110V-230VAC N L N Power Supply 12-36VDC L 43LED/540-W D+ GND V- 12/36VDC D- DC INPUT V+ GND Vin GND V+ R- CH1 0-5 0-9 0-9 OUTPUT Power Supply 12-24VDC 110V-230VAC DMX+ 3 W4 DMX- GND V+ R- CH1 0-5 0-9 0-9 OUTPUT 12/36VDC DC INPUT V+ DMX+ 3 W4 DMX- V+ R- CH1 0-5 0-9 0-9 DMX+ DMXDMX+ 43LED/545 OUTPUT 12/36VDC DC INPUT GND DMX- 2 DMX512 Decoder DMX+ V+ GB- 43LED/545 DMX- V- 2 DMX512 Decoder DMX+ V- GB- 43LED/545 DMX- G2 B- 3 DMX512 Decoder W4 Using instruction Operation Through buttons to set desired DMX512 address, 1 key is to set “hundreds” position, 2 is to set “ten” position, 3 is to set “a” bit. “3" button “2" button “1" button Feature To open the connection of DMX512 controller, then it can work correctly. Standard DMX512 compliant control interface, enable to set the DMX address freely. And show address Via digital numueric display. Three-channel/ four-channel output selectable. Two types available(Constant Voltage, Constant Current),suitable for different LED lamps. To work with power repeater to expand output power unlimitedly. Choose Channel Press 2nd button and 3rd button at the same time for 2 seconds, cH digital display flashes, then press 1st button to choose 1/2/3/4, 3 means total 3 channels, 4 means total 4 channels. Press any button for >2 seconds to confirm the 1,2,3 or 4 channels. The factory preset default is 4 channels outputs. Compatible with SR-2811DMX,SR-2201DMX,SR-2812,SR-2816 and any good quality DMX Master Parameter Part No. Input Voltage Output Current Output Power Remarks 43LED/545 12-36VDC 4x8A 4x(96-288)W constant voltage NOTE: For example, when we set address to 001 When select 1cH, all four channels will be the same address 001. Product Size When select 2cH, channel one and channel three will be the same address 001, channel two and channel four will be 002. When select 3cH, channel 1,2,3 will be address 001,002,003, and channel 4 address is also 001 29 59 When select 4cH, channel 1, 2, 3,4 will be address 001, 002,003,004. 170 Bedienungsanleitungen und Schaltdiagramme finden Sie unter www.leuchtwurm.at mittels Suche der jeweiligen Artikelnummer. Bedienungsanleitungen und Schaltdiagramme finden Sie unter www.leuchtwurm.at mittels Suche der jeweiligen Artikelnummer. Set DMX address Press 1st button for 2 seconds, digital display flashes to set the required DMX address, then press any button for >2 seconds to confirm. Choose PWM frequency Press 1st button and 3rd button for 2 seconds, digital display flashes to show P-c . P means PWM frequency, press 1st to show "1", means 1500Hz, "2" means 200Hz. c means dimming options, press 3rd to show "1", means logarithmic dimming, "2" means linear dimming. The factory preset default is PWM frequency 200Hz with linear dimming. 2-2 Safety & Warnings 1) The product shall be installed and serviced by a qualified person. 2) IP20.Please avoid the sun and rain. When installed outdoors, please ensure it is mounted in a water proof enclosure. 3) Always be sure to mount this unit in an area with proper ventilation to avoid overheating. 4) Please check if the output voltage of any LED power supplies used comply with the working voltage of the product. 5) Never connect any cables while power is on and always assure correct connections to avoid short circuits before switching on. 6) Please ensure that the cable is secured tightly in the connector 7) For update information please consult your supplier. Warranty Agreement 1) We provide lifelong technical assistance with this product: 3-year warranty. We print date on every products, for example :1125 means year 2011,week 25.The warranty is for free repair or replacement and covers manufacturing faults only. For faults beyond the 3-year warranty we reserve the right to charge for time and parts. 2) Limited Warrenty Any defects caused by wrong operation. Any damages caused by unauthorized removal, maintenance, modifying, incorrect connection and replacement of chips. Any damages due to transportation, vibration etc. after purchase. Any damages caused by earthquake, fire, lightning, pollution and abnormal voltage. Any damages caused by negligence, inappropriate storing at high temperatures and humidity or near harmful chemicals. Product has been updated 3) Repair or replacement as provided under this warranty is the exclusive remedy to the customer. Bedienungsanleitungen und Schaltdiagramme finden Sie unter www.leuchtwurm.at mittels Suche der jeweiligen Artikelnummer. Merkmale · Standard DMX512 Decoder mit frei programmierbarer DMX Adresse, Adressanzeige über digitales Display · Ausgangsseitig drei oder vier Kanäle wählbar · Konstantspannungs- oder konstantstromtauglich, geeignet für verschiedene Leuchten · unlimitierte Ausgangsspannung mit Verstärker · kompatibel mit hochqualitativen DMX Master Geräten Bedienungsanleitung Funktion Druckknopf um die gewünschte DMX512 Adresse einzustellen. Schalter 1 zum Einstellen der 100er-Stelle, 2 für die 10er-Stelle, 3 für die 1er-Stelle Kanalwahl Knopf 2 und 3 mehrere Sekunden gleichzeitig drücken, Kanal Digitaldisplay blinkt, dann bitte ersten Knopf drücken um Kanal 1,2 3 oder 4 zu wählen; 3 heißt dabei insgesamt 3 Kanäle, 4 heißt insgesamt 4 Kanäle. Beliebigen Knopf zwei sekundenlang drücken um 1, 2, 3 oder 4 Kanäle zu bestätigen. Fabrikstandardeinstellung auf 4 Kanal. Anmerkung Beispielsweise bei Adresswahl 001 - bei Wahl von 1 Kanal: alle vier Kanäle lauten auf gleiche Adresse 001 - bei Wahl von 2 Kanälen: Kanal eins und drei lauten auf gleiche Adresse 001, Kanal zwei und vier lauten auf 002 - bei Wahl von 3 Kanälen: 1, 2, 3 lauten auf Adressen 001, 002, 003, Kanal 4 lautet wiederum auf 001 - bei Wahl von 4 Kanälen: 1, 2, 3, 4 lauten auf Adressen 001, 002, 003, 004 DMX Adresse einstellen Knopf 1 zwei Sekunden gedrückt halten, Digitale Anzeige blinkt um die erforderliche DMX Adresse einzugeben. Zur Bestätigung beliebigen Knopf mehr als zwei Sekunden gedrückt halten. Wahl der PMW Frequenz Knopf 1 und 3 zwei Sekunden gedrückt halten, Digitale Anzeige blinkt zum Zeigen der P-c. P heißt PMW Frequenz, ersten Knopf drücken um „1“ zu zeigen – dies bedeutet 1500Hz, „2“ bedeutet 200Hz. c heißt Dimmoption, drücken Sie 3 um „1“ = logarithmische Dimmung zu zeigen, „2“ = lineare Dimmung. Werksteinstellung ist auf PCW Frequenz 200Hz mit linearer Dimmfunktion voreingestellt. 2-2 Warnhinweise 1) Installation ausschließlich durch qualifiziertes Fachpersonal 2) IP20. Bitte direkte Sonneneinstrahlung und Regen vermeiden. Außenanwendungen ausschließlich in dichten Gehäusen oder Bereichen. 3) Sorgen Sie stets für ausreichende Belüftung und vermeiden Sie Überhitzung. 4) Bitte prüfen Sie, ob die Ausgangsspannung aller verwendeten LED Netzteile mit der Betriebsspannung des Produktes übereinstimmt. 5) Anschluss immer im ausgeschalteten Zustand. Stellen Sie stets die Verkabelung um Kurzschluss beim Einschalten zu vermeiden. 6) Stellen Sie bitte eine korrekten Sitz der Kabel sicher. 7) Für alle weiteren Informationen wenden Sie sich bitte an die technische Hotline +43/5244/64827-15.
© Copyright 2024 ExpyDoc