BL compact multiprotocol station for Industrial Ethernet 4 Analog Inputs for Current or Voltage and 2 Analog Outputs for Current BLCEN-6M12LT-4AI-VI-2AO-I ■ Compact fieldbus I/O module in IP69K ■ EtherNet/IP™, Modbus® TCP, or PROFINET® slave ■ Integrated Ethernet switch ■ 10 Mbps / 100 Mbps supported ■ Two males M12, 4-pin, D-coded, for fieldbus connection ■ 2 rotary switches for node address ■ IP69K ■ M12 I/O Steckplätze ■ LEDs zur Anzeige von Status und Diagnose ■ Elektronik über Optokoppler galvanisch von der Feldebene getrennt Type code Ident no. BLCEN-6M12LT-4AI-VI-2AO-I 6811482 Nominal system voltage System power supply Voltage supply connection Admissible range Vi Nominal current Vi Max. current Vi Admissible range Vo Nominal current Vo Max. current Vo 24 VDC via auxiliary power 2 x M12, 5-pin 18…30VDC 137 mA 2A 18…30VDC 50 mA 4A Fieldbus transmission rate Adjustment transmission rate Fieldbus address range Protocol detection Web server Service Interface Vendor ID Product type Product code 10/100 Mbps automatic detection 1…92 0 (192.168.1.254) 93 (BootP) 94 (DHCP) 95 (PGM) 96 (PGM-DHCP) *Recommended for PROFINET 97…99 (manufacturer specific) 2 dez. Drehkodierschalter 2 x M12 4-polig, D-kodiert automatic integriert Ethernet 48 12 11482 Modbus TCP Addressing Supported function codes Number of TCP connections Input Data Size Input register start address Output Data Size Output register start address Static IP, BOOTP, DHCP FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, FC23 6 max. 6 register 0 (0x0000 hex) max. 2 register 2048 (0x0800 hex) ■ 0/4…20 mA or -10/0…+10 VDC (kanalweise umschaltbar) ■ 2 analoge Stromausgänge ■ 0/4…20 mA Edition • 2016-03-24T22:19:56+01:00 Fieldbus addressing Fieldbus connection technology ■ 4 analoge Eingänge für Strom oder Spannung 1/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com BL compact multiprotocol station for Industrial Ethernet 4 Analog Inputs for Current or Voltage and 2 Analog Outputs for Current BLCEN-6M12LT-4AI-VI-2AO-I EtherNet/IP™ Addressing Device Level Ring (DLR) Number of CIP connections Input Assembly Instance Input Data Size Output Assembly Instance Output Data Size Configuration Assembly Instance Configuration Size Comm Format acc. to EtherNet/IP™ specification supported 6 103 7 INT 104 2 INT 106 0 Data - INT PROFINET Addressing Conformance class MinCycleTime Diagnostics Topology detection Automatic addressing Media Redundancy Protocol (MRP) Input Data Size Output Data Size DCP B (RT) 1 ms acc. to PROFINET alarm handling supported supported supported max. 8 BYTE max. 4 BYTE from 4AI-VI 0/4 … 20 mA or -10/0 … 10 VDC channel diagnostics 24 VDC Strom: < 0,125 Kò, Spannung: < 98,5 Kò < 20 Hz < 0.3 % < 0.05 % < 300 ppm/ºC of full scale 16 bit Sigma Delta 16 bit signed integer 12 bit full range left-justified Analog outputs Output type Type of output diagnostics Sensor supply Load resistance, resistive Load resistance, inductive Transmission frequency Basic fault limit at 23 °C Repeatability Temperature coefficient Resolution Measured-value display from 2AO-I 0/4 … 20 mA Channel diagnostics 24 VDC < 0,45 < 1 mH < 200 Hz < 0.2 % < 0.05 % < 150 ppm / ºC v.E. 16 bit 16 Bit Signed Integer 12 bit full range left justified Edition • 2016-03-24T22:19:56+01:00 Analog inputs Operating modes Type of input diagnostics Sensor supply Input resistance Maximum limiting frequency analog Basic fault limit at 23 °C Repeatability Temperature coefficient Resolution Measuring principle Measurement display 2/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com BL compact multiprotocol station for Industrial Ethernet 4 Analog Inputs for Current or Voltage and 2 Analog Outputs for Current BLCEN-6M12LT-4AI-VI-2AO-I Dimensions Operating temperature Storage temperature Relative humidity Vibration test Extended vibration resistance - up to 20 g (at 10 to 150 Hz) Shock test Electro-magnetic compatibility Protection class Bei Festmontage auf Trägerplatte oder Maschinenkörper. nach IEC 61131-2 nach IEC 61131-2 IP67 IP69K Nylon glasfaserverstärkt, Stecker nickelbeschichtet black Lexan nickel-plated brass Polyester with Polycarbonate overlay nickelbeschichtetes Messing 600 ± 20 g CE, cULus Edition • 2016-03-24T22:19:56+01:00 Housing material Housing color Window material Screw material Label material Ground tab material Weight Approvals and certificates 168 x 71 x 32.5 mm -40…+70 ºC -40…+85 ºC 15 to 95% (nicht kondensierend) nach IEC 61131-2 3/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com BL compact multiprotocol station for Industrial Ethernet 4 Analog Inputs for Current or Voltage and 2 Analog Outputs for Current BLCEN-6M12LT-4AI-VI-2AO-I Ethernet Fieldbus cable (example): RSSD RSSD 441-2M ident-no. U-02482 or RSSD-RSSD-441-2M/S2174 ident-no. 6914218 Slot 1: Analog Inputs Pin Assignment Extension cable (example): RK 4.5T-2-RS 4.5T/S653 ident-no. U2187-09 or RKC4.5T-2-RSC4.5T/TEL ident-no. 6625212 2-wire connection (current) 4-wire connection technology Edition • 2016-03-24T22:19:56+01:00 ? 4/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com BL compact multiprotocol station for Industrial Ethernet 4 Analog Inputs for Current or Voltage and 2 Analog Outputs for Current BLCEN-6M12LT-4AI-VI-2AO-I Slot 2: Analog Outputs Pin Assignment Extension cable (example): RK 4.5T-2-RS 4.5T/S653 ident-no. U2187-09 or RKC4.5T-2-RSC4.5T/TEL ident-no. 6625212 Auxiliary Power Pin Assignment Extension cable (example): RKC 4.4T-2-RSC 4.4T ident-no. Edition • 2016-03-24T22:19:56+01:00 U5264 or RKC4.4T-2-RSC4.4T/TEL ident-no. 6625208 5/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com BL compact multiprotocol station for Industrial Ethernet 4 Analog Inputs for Current or Voltage and 2 Analog Outputs for Current BLCEN-6M12LT-4AI-VI-2AO-I Status: Station LED LED Color Status Description OFF Power off RED ON Insufficient power supply RED FLASHING (1Hz) Deviating station configuration RED FLASHING (4 Hz) No module bus communication GREEN ON Station OK GREEN FLASHING Force mode active OFF No connection GREEN ON Fieldbus communication active GREEN FLASHING (1Hz) Fieldbus communication disabled, device status OK RED ON Double MAC-ID RED FLASHING Fieldbus communication timeout GREEN ON I/O slots OK GREEN FLASHING (1Hz) At least one I/O slot in idle state RED ON At least one faulty I/O slot RED FLASHING At least one I/O slot in faulty state Color Status Description OFF Diagnostic disabled RED ON Station / module bus communication failure RED FLASHING (0.5Hz) Summarized diagnostic OFF Channel inactive GREEN ON Channel active GREEN FLASHING (0.5 Hz) Measuring range undershoot GREEN FLASHING (4 Hz) Measuring range overshoot Status Description OFF Diagnostic disabled RED ON Station / module bus communication failure RED FLASHING (0.5Hz) Summarized diagnostic IOs MNS IO Status: I/O LED, slot 1 LED D1 * AI channels 10…13 * D1 LED also indicates gateway diagnostic I/O LED Status Slot 2 LED Colour D2 * AO channels Not connected 0/1 Edition • 2016-03-24T22:19:56+01:00 * The D2 LED also indicates gateway diagnosis 6/7 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com BL compact multiprotocol station for Industrial Ethernet 4 Analog Inputs for Current or Voltage and 2 Analog Outputs for Current BLCEN-6M12LT-4AI-VI-2AO-I Prozessdaten Mapping der einzelnen Protokolle EtherNet/IP™ I/O und Diagnosedaten Mapping INPUT BYTE Bit 7 AI 10 0 AI 10 LSB 1 AI 10 MSB 2 AI 11 LSB 3 AI 11 MSB 4 AI 12 LSB 5 AI 12 MSB 6 AI 13 LSB 7 AI 13 MSB 8 Modulnummer meldet Diagnose Daten 9 Austauschsta- - Diagnose ak- - tion tiv AI 11 AI 12 AI 13 Diagnose Steckplatz 1 10 Bit 6 - Bit 5 - Bit 4 - - Bit 3 Bit 2 Bit 1 Bit 0 - - - - - - Offener Bereichsfehler (ref. Byte 8) Stromkreis AI AI 10 10 11 - - - - - - Offener Bereichsfehler Stromkreis AI AI 11 11 12 - - - - - - Offener Bereichsfehler Stromkreis AI AI 12 12 13 - - - - - - Offener Bereichsfehler Stromkreis AI AI 13 13 OUTPUT BYTE Bit 7 AO 20 0 AO 20 LSB 1 AO 20 MSB 2 AO 21 LSB 3 AO 21 MSB AO 21 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Modbus TCP Register Mapping REG Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 0x0000 AI 10 0x0001 AI 11 0x0002 AI 12 0x0003 AI 13 Status (RO) 0x0004 - FCE - - CFG COM VI low - Diag. (RO) 0x0005 - - - - - - - - Outputs (RW) 0x0800 AO 20 0x0801 AO 21 - - - - - OCAI MRAI 11 11 OCAI MRAI 13 13 Inputs (RO) I/O Diag. (RO) 0xA000 0xA001 - - - - - - Bit 8 Bit 7 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 VO low - - - - - - DIA - - - - - - S2 DIA S1 DIA - - - - - - OCAI MRAI 10 10 OCAI MRAI 12 12 - Bit 6 - - - - - PROFINET® Process Data Edition • 2016-03-24T22:19:56+01:00 Eingänge Ausgänge 7/7 BYTE Bit 7 0 AI 10 LSB 1 AI 10 MSB 2 AI 11 LSB 3 AI 11 MSB 4 AI 12 LSB 5 AI 12 MSB 6 AI 13 LSB 7 AI 13 MSB 0 AO 20 LSB 1 AO 20 MSB 2 AO 21 LSB 3 AO 21 MSB Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
© Copyright 2024 ExpyDoc