PULSED RF POWER AMPLIFIER -参考出品-

PULSED RF POWER AMPLIFIER -参考出品■
■
■
■
R&K-CGA9400BW200-5252MP
X-Band All Solid State Amplifier
Broadband Frequency:9.4GHz±100MHz
Output Power
:160W(min.)@Psat(Pulse)
With Output Circulator
SPECIFICATIONS @+25℃
OUTLINE DRAWING
Frequency Range
: 9.4GHz±100MHz
In-Band Signal Gain
: +52dB (min.) @Po=+52dBm(Pulse)
In-Band Gain Flatness
: ±0.5dB (max.) @Po=+52dBm(Pulse)
Output Power
: 160W (min.)
@Psat(Pulse)
Operation Mode
: Class AB
RF Pulse Width
: 100μS (max.)
RF Pulse Duty
: 20% (max.)
RF Pulse Rise and Fall time : 50nS (max.)
Impedance
: 50Ω
Input / Output VSWR
: 2.0 : 1 (max.)
Harmonics
: -60dBc (max.) @Po=+52dBm(Pulse)
Spurious
: -60dBc (max.) @Po=+52dBm(Pulse)
DC Supply Input
: +48V ±1V
Efficiency
: 25% (typ.)
Maximum RF Input Power : +10dBm
Operating Temperature
: -20℃ to +60℃
Storage Temperature
: -20℃ to +80℃
Connectors(Standard)
: SMA‐FEMALE
Protection Circuits
: Output Circulator
Over Temperature Protection
Reverse Connection Protection Diode
※IN MILLIMETERS
TYPICAL PERFORMANCE (Temp @+25℃)
Input / Output VSWR
5
Input VSWR
Output VSWR
52
50
Output Power (dBm)
48
46
44
3
2
42
Output Power Linearity & Efficiency
40
80
50
70
48
60
46
50
44
40
30
42
Efficiency
9.3
Switching Speed
CONT
RF OUT
9.4
Frequency (GHz)
RF OUT
CONT
9.5
9.6
9.4GHz / +52dBm
2kHz / Duty 20%
V : 5V / Div.
H : 50nS / Div.
V : 100mV / Div. H : 50nS / Div. ATT : 55dB
9.2
9.3
Switching Speed
CONT
RF OUT
9.4
Frequency (GHz)
RF OUT
CONT
9.5
9.6
9.4GHz / +52dBm
2kHz / Duty 20%
V : 5V / Div.
H : 50nS / Div.
V : 100mV / Div. H : 50nS / Div. ATT : 55dB
-14
-12
-10
-8
-6
-4
9.3GHz
9.4GHz
9.5GHz
Pulse Width 100μS
Pulse Duty 20%
-2
Input Power (dBm)
Switching Speed
CONT
RF OUT
Frequency
Pulse Duty
1%
2%
5%
10%
40
9.2
100
90
52
4
VSWR
Output Power (dBm)
54
RF OUT
CONT
Efficiency (%)
RF Output Power Flatness
54
0
2
20
10
0
9.4GHz / +52dBm
2kHz / Duty 20%
V : 5V / Div.
H : 50nS / Div.
V : 100mV / Div. H : 50nS / Div. ATT : 55dB
本製品及び、これに使用される技術は、輸出貿易管理令別表に定められた規定により輸出の際には
輸出許可が必要となります。 弊社は、安全保障輸出管理の法遵守の為、本製品に関わる詳細な
情報及びデータ等の提供は、国内外での使用に関わらず、最終需要者様の詳細情報の開示を条件
とします。ご理解、ご協力の程よろしくお願いいたします。