COLOR SCANNING SONAR FSV-84 - Furuno USA

COLOR SCANNING SONAR
FSV-84
www.furuno.co.jp
The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
Telephone : +81-(0)798-65-2111
Fax
: +81-(0)798-65-4200
All rights reserved.
Printed in Japan
A : SEP . 2006
B3 : JUN . 21, 2007
Pub. No. IME-13290-B3
(DAMI )
FSV-84
*00015742911*
*00015742911*
* 0 0 0 1 5 7 4 2 9 1 1 *
SAFETY INSTRUCTIONS
The installer must read the safety instructions before attempting to install the equipment.
DANGER
Indicates a potentially hazardous situation which, if not avoided,
will result in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury.
Warning, Caution
Prohibitive Action
DANGER
Keep away from raise/lower
shaft in hull unit when it is
moving.
Gears will cause serious injury.
Mandatory Action
WARNING
Do not install the equipment where it
may get wet from rain or water splash.
Water can cause fire or electrical shock, or
damage the equipment.
Be sure no water leaks in at the transducer installation site.
WARNING
Do not open the equipment unless
totally familiar with electrical circuits
and service manual.
High voltage exists inside the equipment,
and a residual charge remains in capacitors
severalminutes after the power is turned off.
Improperhandling can result in electrical
shock.
Turn off power at the switchboard before
beginning the installation.
Electrical shock or fire can result if the
the power is left on.
Water leakage can sink the vessel. Also
confirm that the transducer will not loosen
by ship's vibration. The installer of the
equipment is solely responsible for the
proper installation of the equipment.
FURUNO will assume no responsibility for
any damage associated with improper
installation.
Install the specified transducer tank
in accordance with the installation
instructions. If a different tank is to be
installed the shipyard is solely responsible for its installation, and it should
be installed so the hull will not be
damaged if the tank strikes an object.
The tank or hull may be damaged if the
tank strikes an object.
i
WARNING
If a steel tank is installed on a wooden
or FRP vessel, take appropriate
measures to prevent electrolytic
corrosion.
CAUTION
Maximum speed while the transducer is
projected or being raised or lowered
is as below, to prevent damage to the
transducer.
Electrolytic corrosion can damage the
hull.
Be sure to power each unit with proper
voltage.
Projected
800 mm stroke
Raising/
Lowering
Max. 18 kt Max. 15 kt
1100 mm stroke Max. 18 kt Max. 15 kt
Connection of an improper power supply
can cause fire or damage the equipment.
Observe the following compass safe
distances to prevent interference to a
magnetic compass:
Standard
compass
Steering
compass
Processor Unit
2.05 m
1.35 m
Control Unit
0.20 m
0.15 m
Monitor Unit
1.25 m
0.85 m
Ground the equipment to prevent
electrical shock and mutual
interference.
ii
TABLE OF CONTENTS
SYSTEM CONFIGURATION .......................................................................................... iv
EQUIPMENT LISTS ....................................................................................................... vi
1. MOUNTING THE EQUIPMENT..............................................................................1-1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
Hull Unit ............................................................................................................................... 1-1
Processor Unit ..................................................................................................................... 1-7
Monitor Unit (option) ............................................................................................................ 1-8
Control Unit .........................................................................................................................1-11
Transceiver Unit................................................................................................................. 1-13
Attachment Kit (option) ...................................................................................................... 1-14
FRP Tank (option) .............................................................................................................. 1-16
Control Box Extension Kit (option)..................................................................................... 1-18
2. WIRING ..................................................................................................................2-1
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
How to Use the Crimping Tool, Pin Extractor ...................................................................... 2-1
Wiring................................................................................................................................... 2-2
Monitor Unit (option) ............................................................................................................ 2-4
Processor Unit ..................................................................................................................... 2-8
Transceiver Unit................................................................................................................. 2-14
Control Box of Hull Unit ..................................................................................................... 2-17
Input Voltage and Fuses .................................................................................................... 2-18
Controller Extension Kit (Junction Box)............................................................................. 2-19
3. ADJUSTMENT AND CHECK.................................................................................3-1
3.1
3.2
3.3
3.4
3.5
3.6
Hull Unit Check .................................................................................................................... 3-1
Heading Adjustment............................................................................................................. 3-4
Configuring Own Ship Mark................................................................................................. 3-6
Other SYSTEM Menu Items ................................................................................................ 3-7
CONE Board Setting in the Processor Unit....................................................................... 3-12
DIP Switch Setting ............................................................................................................. 3-13
4. CONNECTING EXTERNAL INTERFACE CS-120A ..............................................4-1
PACKING LIST............................................................................................................ A-1
OUTLINE DRAWINGS ................................................................................................ D-1
INTERCONNECTION DIAGRAMS ............................................................................. S-1
iii
SYSTEM CONFIGURATION
System with locally supplied monitor
CONTROL UNIT
FSV-8401
External
Monitor
External equipment
Option
AD Converter
AD-100
CONTROL UNIT
FSV-8401
Speed Log
Loudspeaker
Current
Indicator
Speed Log
Echo Sounder,
Current Indicator,
other
PROCESOR UNIT
Navigator 1
E/S Interface
VI-1100A
FSV-8402
Net Recorder
Navigator 2
VI-1100A
Net Sonde
Junction Box
CS-170
External
Interface CS-120A
(Note 1)
Net Sonde
220 VAC,
3φ, 50/60 Hz
100-115/
220-230 VAC,
1φ, 50/60 Hz
TRANSCEIVER UNIT
FSV-841A
Satellite
Compass
SC-50/110
100/110/115/
220/230 VAC,
1φ, 50/60 Hz
Note 1: Power Kit (option, installed in
processor unit) required to connect CS-120A.
iv
VI-1100A
HULL UNIT
FSV-8432
FSV-8442
System with FURUNO monitor
CONTROL UNIT
FSV-8401
MONITOR
UNIT
FSV-2400
External equipment
Option
AD Converter
AD-100
CONTROL UNIT
FSV-8401
Speed Log
Loudspeaker
Current
Indicator
Sub Monitor
Speed Log
Echo Sounder,
Current Indicator,
other
PROCESSOR UNIT
Navigator 1
E/S Interface
VI-1100A
FSV-8402
Net Recorder
Navigator 2
VI-1100A
Net Sonde
Junction Box
CS-170
External
Interface CS-120A
(Note 1)
100-115/
220-230 VAC,
1φ, 50/60 Hz
Satellite
Compass
SC-50/110
E/S Interface
VI-1100A
Net Sonde
220 VAC,
3φ, 50/60 Hz
TRANSCEIVER UNIT
FSV-841A
HULL UNIT
FSV-8432
FSV-8442
100/110/115/
220/230 VAC,
1φ, 50/60 Hz
Note 1: Power Kit (option, installed in
processor unit) required to connect CS-120A.
v
EQUIPMENT LISTS
Standard supply
Name
Control Unit
Processor Unit
Transceiver Unit
Hull Unit
Installation
Materials*
Accessories*
Spare Parts*
Type
FSV-8401-10
FSV-8402-100
FSV-8402-200
FSV-841A
FSV-8432
Code No.
—
—
—
—
—
FSV-8442
Qty
1
Remarks
w/10 m cable
110 VAC
220 VAC
1
1
800 mm stroke w/motion sensor
& no dome
1100 mm stroke w/motion
sensor & no dome
Cable between transceiver unit
and hull unit, 8 m
For transceiver unit
For processor unit,
CP10-04502, CP10-04506
For processor unit
Memory card for control unit
For transceiver unit
For processor unit
For hull unit
1
—
CP10-06000
000-067-071
1 set
CP10-07011
001-005-660
1 set
CP10-06100
000-067-067
1 set
FP10-02901
FP10-02201
SP10-03101
SP10-02601
SP10-02603
007-008-780
006-922-390
007-008-530
006-921-340
006-921-360
1 set
1 set
1 set
1 set
1 set
Optional equipment
Name
Power Kit for
CS-120A
Hood
Loudspeaker
Code No.
Qty
000-067-013
1
FP03-06503
SEM-21Q
MJ-A6SPF0012-050C
MJ-A6SPF0012-100C
008-490-970
000-144-917
000-154-053-10
000-154-037-10
1
1
1
1
8-core Cable
VVS 0.3×8C *6M*
000-555-043
1
37-core Cable
E/S Interface
Net Sonde
Junction Box
10S1258
VI-1100A
CS-170
000-101-006
—
—
1
1
1
Cable Assy.
Type
FSV-2403
FSV-2400-10
—
Monitor Unit
Control Unit
Installation
Material for
interface*
Attachment Kit
Retraction Tank
Controller
Extension Kit
1
FSV-8401-5
FSV8401-10
—
—
CP10-04801
006-934-240
1
OP10-30
OP10-28
OP10-29
00-067-179
000-067-077
000-067-178
1
FSV-846
* See packing list at back of this manual.
vi
1
—
1
Remarks
For CS-120A
For monitor unit
5 m, NMEA, 6P-6P
10 m, NMEA, 6P-6P
6 m, for echosounder,
02S8040
Length specified by user
CP10-04501, FP03-06201,
FP10-02201, FP10-02202,
FP10-02203, Dust cover
w/5 m cable
w/10 m cable
See section 1.7.
For steel vessel
For FRP vessel
For control box in hull unit
1. MOUNTING THE EQUIPMENT
1.1 Hull Unit
Note 1: The raise/lower control box on the hull unit contains a motion sensor. Therefore,
never drop the hull unit.
Note 2: Handle the transducer carefully. Shock will damage its sensitive components.
1.1.1 Mounting considerations
Decide the location of the hull unit through consultation with the dockyard and ship owner.
When deciding the location, the following points should be taken into account.
• Choose an area where propeller noise, cruising noise, air bubbles and interference from
turbulence are at a minimum. Generally, the point at 1/3 to 1/2 of the ship’s length from the
bow on or near the keel is optimum. On-the-keel installation is advantageous for
minimizing oil consumption in comparison with off-the-keel. If the hull unit can not be
installed on the keel, the center of the retraction tank should be within 600 mm of the keel
to prevent a rolling effect. For large ship with deep draft, the hull unit can be installed at
the bow.
1/2
1/3
Within 600 mm
Hull unit mounting location
• Choose a place where the hull bottom is flat and the draft is sufficiently deep. Normally,
the transducer should protrude at least 500 mm beyond the keel to minimize the effect of
air foam and bubbles.
• Choose a place where interference from other transducers is minimal. The hull unit should
be at least 2.5 m away from the transducers of other equipment.
• No obstacle should be in the fore direction since it causes a shadow zone and aerated
water, resulting in poor sonar performance.
• The physical distance between the hull unit and the transceiver unit should be no more
than 5 m.
• The space shown in the figure on the next page is required around the hull unit for wiring
and maintenance.
• If the ambient temperature around the unit will be below 0°C, provide the sonar
compartment with a heater to keep the temperature above 0°C. See the next page for
details.
1-1
1200 mm
500 mm
500 mm
500 mm
Compartment
Maintenance space, example sonar compartment
Note: After mounting the equipment, be sure to install anti-vibration stays, as shown on
page 1-6.
1-2
1.1.2 Shortening the retraction tank
Shorten the tank as necessary so that the transducer positions well below the keel when it is
fully lowered. The following table provides guidelines for shortening the tank. Refer also to
the retraction tank installation drawing at the back of this manual.
Installation
Method
D
D
Stroke
800 mm
stroke
1100 mm
stroke
Remove
0-50 mm
from the
bottom.
Remove 0-50 mm
from the bottom.
Same as left. Note that the length
"D" must be less than
1000 mm.
Same as left.
Remove
0-50 mm
from the
bottom.
Remove 0-50 mm from
the bottom. Note that
the length "D" must be
Same as left.
less than 1200 mm.
Same as left.
Guidelines for shortening the retraction tank
Note 1: The transducer will lower to mid-protrusion (500/800 mm stroke) if the tank is not
shortened. However, if it is shortened more than 50 mm, the transducer cannot be
completely retracted.
Note 2: When maximum length is removed and “D” is minimum, the effect of air foam is
minimized because the transducer fully protrudes in water.
1-3
1.1.3 Remarks for installation of retraction tank
1. Install, if possible, the tank on the keel where the tank can be most firmly fixed.
2. Install the reinforcement ribs as near as possible to the top of the retraction tank, allowing
space for tightening of nuts and bolts.
Retraction tank
Reinforcement rib
Minimum quantity: 4
Thickness: at least 12 mm
250-300 mm
How to install reinforcement ribs
3. Add a doubling plate (a plate added to another to give extra strength or stiffness) at the
location where the retraction tank is welded to the hull bottom. The size of the doubling
plate is such that it may lie across two bottom frames.
1-4
1.1.4 Installing hull unit on retraction tank
After welding the retraction tank and allowing sufficient time for cooling, install the hull unit
as follows:
1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount
of grease. Place the O-ring in position on the tank flange.
2. Orient the hull unit so that the bow mark (inscribed) on its flange points toward the ship’s
bow. Note that heading adjustment is required if the bow mark is not facing the ship’s
bow.
3. Confirm that the O-ring is in position. Place the hull unit on the tank.
4. Coat every washer, nut and bolt with a slight amount of grease to ease removal. Fasten
the hull unit to the retraction tank with flat washers, spring washers and hex bolts.
5. Reinforce the hull unit against vibration by extending stays to the ship’s hull from the two
eye bolts at the top of the hull unit, referring to the procedure on the next page.
Nut
Spring washer
Flat washer
BOW mark
Hull unit flange
O-ring
Tank flange
Flat washer
Hex bolt
Nut
Spring
washer
Flat washer
O-ring
RETRACTION
TANK
Hex bolt
(16 places)
Installation of hull unit
1-5
1.1.5 Installing stays (anti-vibration measure)
Install stays from the top of the hull unit to the ship’s hull. The stays should be angle iron
with a size of 75×75×9 mm or more and at least two pieces should be used; one each to
ship’s bow and stern directions. This measure must be done to prevent damage to the
transducer.
Stay fixed to crossbeam on overhead
(WRONG installation method)
Stay
Eye Bolt
Stay installed horizontally
(PROPER installation method)
Hull Unit
90
Proper installation of stays
After installing the hull unit, attach the hand crank to the location shown in the figure below.
Double-end ratchet wrench
RN2430L
Handle fixing plate 2
10-086-5742
Handle fixing plate 1
10-086-5741
Pan head screw
M4x10, 2 pcs.
Wing bolt
M4x10, 2 pcs.
Fixing hand crank to hull unit
1-6
1.2 Processor Unit
Mounting considerations
When choosing a mounting location, keep in mind the following points:
• The processor unit must be mounted upright.
• Locate the unit out of direct sunlight and away from heat sources because of heat that can
build up inside the cabinet.
• Do not locate the equipment where it may be subjected to water splash or rain.
• Be sure the mounting location is strong enough to support the weight of the unit under the
continued vibration which is normally experienced on the ship. If necessary reinforce the
mounting location.
• Determine the mounting location considering the length of the cables below.
● Signal cable from the transceiver unit
● Monitor cable from the monitor
● Control cable from the control unit (when locally supplied monitor is used)
• Leave sufficient space on the sides and rear of the unit to facilitate maintenance. Also,
leave a foot or so of "service loop" in cables behind the unit so it can be pulled forward for
servicing or easy removal of connectors. See the outline drawing for recommended
maintenance space.
• Observe the compass safe distances shown on page ii to prevent interference to a
magnetic compass.
• Make free space of at least 40 cm between the processor unit and bulkhead to prevent
cable stress.
• Prepare cable entrance ABOVE the unit. Consider cable bend with cable fixed by cable
clamp at rear of the unit.
Cable entrance
Processor unit, rear view
1-7
Mounting procedure
1. Unfasten two bolts from the bottom of the front side of the processor unit. Pull the unit
toward you to separate it from the mounting base.
2. Use six bolts (supplied as installation material) to fix the mounting base.
3. Place the processor unit in front of the mounting base.
4. Push the unit forward until it touches the end of the mounting base.
5. Refasten two bolts removed at step 1 to fix the unit to the mounting base.
505
477
160±1
5.5
φ8
34
200±1
195±1
Unfasten two bolts
Mounting dimension for processor unit
1.3 Monitor Unit (option)
Mounting considerations
• The monitor unit is designed for mounting on a tabletop.
• Locate the monitor unit where it can be easily operated while viewing the screen and
operating the control unit.
• Locate the monitor unit out of direct sunlight and away from heat sources because of heat
that can build up inside the cabinet.
• Do not locate the equipment where it may be subjected to water splash or rain.
• Be sure the mounting location is strong enough to support the weight of the unit under the
continued vibration which is normally experienced on the ship. If necessary reinforce the
mounting location.
• The length of the monitor cable which runs between the control unit and the monitor unit is
10 m. Keep this distance in mind when choosing a mounting location.
• Leave sufficient space on the sides and rear of the unit to facilitate maintenance.
• Observe the compass safe distances shown on page ii to prevent interference to a
magnetic compass.
1-8
Mounting procedure
1. Drill four holes of 12 mm in diameter in the mounting location, referring to the outline
drawing for mounting dimensions.
2. Unfasten two M4×10 screws to dismount the front cover.
3. Unfasten two sets of M10 bolts, plain washers and spring washers to separate the
monitor from the mounting base.
4. Pull the monitor forward about 4 cm and then lift it to separate it from the mounting base.
5. Fasten the mounting base to the mounting location with M10 bolts, nuts and washers
(local supply).
6. Lay the monitor on the top of the mounting base, mating the rear pin on the monitor to
the slit in the mounting base. Fix the monitor to the mounting base with the two sets of
bolts, nuts and washers unfastened at step 3.
7. Close the front cover.
Plain Washer, M10, 2 pcs.
Spring Washer, M10, 2 pcs.
Pin
Hex Bolt
M10x30,
2 pcs.
Hex Bolt
M10, 4 pcs.
Washer
Front Cover
Pan-Head Screw
M4x10, 2 pcs.
Slit
Mounting Base
Monitor unit
1-9
Attaching the CRT filter
1. Attach two spacers (5×2.5, supplied) with screws (M5×10, supplied) to the location
shown below.
2. Screw two hood retainers (supplied) into the filter (supplied).
3. Set two washers (supplied) into the two hood retainers attached at step 2.
4. Attach the filter to the monitor unit as shown below.
Hood retainer (2 pcs.)
Washer (2 pcs.)
M5
tapping hole
(Up side)
Filter
CRT
Notch
(Down side)
Spacer (2 pcs.)
Screw (2 pcs.)
How to attach the hood
1-10
1.4 Control Unit
The control unit is designed for mounting on a tabletop, with or without the KB (keyboard)
fixing plate (supplied), which mounts the control unit at an angle. If the control unit is not to
be fixed permanently, lay it atop the rubber feet (supplied as accessories). Be sure to
observe the compass safe distances noted on page ii to prevent interference to a magnetic
compass.
Mounting without KB fixing plate
1. Drill four mounting holes of 6 mm diameter to fasten the control unit, referring to the
outline drawing at the back of this manual.
2. Referring to the outline drawing for the control unit at the back of this manual, make a
cutout in the mounting location large enough to accommodate the name plate so the
control unit will lie flat.
3. Fix the control unit with four bolts (M5) from under the tabletop. (M5 bolts with a sufficient
length for the thickness of the tabletop should be provided locally.)
467±1
75 ±1 22
Fixing hole φ6
FSV-84
Control unit
Mounting with KB fixing plate
1. To fix the control unit to a desired location at an angle, fasten the KB fixing plate to the
control unit and desired location with two upset screws (M5×10, supplied) and two
tapping screws (φ6.5, local supply) as below.
450
Upset screw (M5x10)
FSV-84
Tapping screw
( 6.5)
KB fixing plate
How to attach KB fixing plate
2. Set dust cover (supplied) to the control unit.
1-11
Passing the cable through the bottom of the control unit (for permanent mounting)
For permanent mounting methods (2) and (3), the control cable can be passed through the
bottom of the control unit as follows:
1. Unfasten eight screws (M4) to
remove the cover from the bottom
Screw
of the control unit.
M4x8 (8 pcs.)
2. Unscrew two screws (M4×10) to
remove the cable clamp.
3. Disconnect two connectors J1 and
J1
Co
J2
ntr
J2 from the circuit board.
ol
u
nit
4. Attach the control cable to the
co
ve
control unit cover with the cable
r
Previous cable hole
Nut
clamp (removed at step 2), two
Clamp
Spring washer
flat head screws (M4), flat
Flat washer
washers, spring washers and nuts
Screw (M4x12)
(hardware: supplied).
Fasten the cable with the clamp here.
5. Re-connect two connectors
Control unit, cover removed
disconnected at step 3.
6. Fasten eight screws to attach the
control unit cover.
7. Attach the connector seal (supplied) to the hole at the rear of the control unit.
8. Drill a hole of 30 mm in diameter to pass the cable from the bottom of the control unit
through the tabletop
9. Attach the connector seal (supplied) to the hole at the bottom of the control unit when the
above modification is not done.
10. Fix the control unit referring to (2) or (3) on the previous page.
Hole for leading in cable
FSV-84
Cable
Cable
Without KB fixing plate
With KB fixing plate
Control unit, side view
1-12
1.5 Transceiver Unit
The length of the cable between the transceiver unit and the hull unit is 5 m, so choose a
mounting location within 5 m of the hull unit. The transceiver unit should be fixed to a
mounting base (shipyard supply) whose dimensions are as shown in the outline drawing at
the back of this manual. Reinforce the transceiver unit against vibration by stays extending
from the eyebolts on the top of the unit. Fasten four bolts (M12, local supply) at the bottom
of the transceiver unit to fix the unit to the mounting location.
CABLE CLAMP
GND TERMINAL
EYE BOLT
(4 pcs.)
GROUND
TERMINAL
CABLE
ENTRANCE
CABLE CLAMP
MOUNTING BASE
(shipyard supply)
CABLE ENTRANCE
(mounting base)
Mounting dimensions for transceiver unit
1-13
1.6 Attachment Kit (option)
The attachment kit permits use of the tank for the CSH-80 series.
Attachment kit (Type: OP10-30, Code no.: 000-067-179)
Name
Insulation gasket (1)
Insulation gasket (2)
O-ring
Type
SHG-0003-0
MS-1000-68
C00117A
Code No.
Qty
100-038-570
000-857-221
000-158-976-10
1
16
1
1. Clean the hull unit flange, the O-ring and O-ring groove. Coat them with a slight amount
of grease. Place the O-ring in position on the tank flange.
2. Lay the insulation gasket (1) on the top of the tank flange.
3. Orient the hull unit so that the bow mark (inscribed) on its flange points toward the ship’s
bow. Note that heading adjustment in the monitor unit is required if the bow mark does
not face the ship’s bow.
4. Confirm that there is no foreign material on the surface of the retraction tank flange, and
then do the following:
a) Place the hull unit on the tank.
b) Confirm that the O-ring and the insulation gasket (1) are in position.
5. Insert the insulation gasket (2) into the bolt holes of the tank flange.
6. Coat every bolt, washer and nut with a slight amount of grease to ease removal. Fit the
insulation gasket (2) into the bolt holes of the tank flange.
6. Fasten the hull unit to the retraction tank with insulation gasket (2), flat washers, spring
washers and hex bolts.
1-14
Hex.nut
Hex.nut
Spring washer
Flat washer
Spring washer
Flat washer
Hull unit flange
O ring
O ring
Insulation gasket (1)
Insulation gasket (1)
Insulation gasket (2)
Insulation gasket (2)
Flat washer
Flat washer
Hex. bolt
Hex. bolt
Hex. nut
Spring washer
Flat washer
O ring
Insulation gasket (1)
Retraction tank
Insulation gasket (2)
Hex. bolt
1-15
1.7 FRP Tank (option)
Caution for installing FRP tank
Use an FRP tank supplied by FURUNO. Other makes of tank may be used, however
watertightness cannot be guaranteed. A non-FURUNO make of tank should meet the
following requirements:
- The surface of the FRP tank flange must be flush (within 0.5 mm) with tank.
- Use the sealant recommended by shipyard.
Contents of FRP retraction tank installation kit
Name
Type
Retraction Tank (FRP)
Waterproofing Gasket
Three Bond
OP10-29-1
SHH-0003-1
1101 200G
Code No.
007-022-920
660-800-031
000-854-101
Qty
1
1
1
Fasten the hull unit to the retraction tank (after installing the retraction tank) as follows:
1. Clean the surface of the tank flange. Coat the flange with about 1mm thickness of
sealant (Three Bond, supplied). USE ONLY THE SUPPLIED SEALANT.
Sealant
2 mm
1 mm
100 mm
FRP tank
2. Lay the waterproofing gasket on the tank flange and coat the gasket with about 1 mm
thickness of sealant.
Sealant
Waterproofing gasket
FRP tank
Note: Use only specified waterproofing gasket.
3. Orient the bow mark (arrow) on the hull unit flange toward ship’s bow. (If the mark cannot
be perfectly oriented toward ship’s bow, adjust heading after installation, as shown later
in this manual.
Flange
BOW
1-16
4. Set the hull unit on the top of the retraction tank, observing the following cautions:
- Clean the hull unit flange to make sure no foreign material has fallen into the retraction
tank.
- Confirm that the waterproofing gasket is properly in place.
Bolt hole
5. As shown in the figure below use bolts, nuts and washers to fasten the hull unit to the
retraction tank.
Nut
Spring washer
Flat washer
Flange at hull unit
Flange at tank
Flat washer
Bolt
1-17
1.8 Control Box Extension Kit (option)
The control box may be mounted separately from the hull unit. Detach the control box and
mounting plate from the hull unit and fix the junction box of the control box extension kit to
the hull unit, with four M5 bolts
MOUNTING PLATE
10-086-5614, 2 pcs.
FLAT WASHER
M10, 4 pcs.
SCREW
M10X25, 4 pcs.
Mounting holes for junction
box of cable extension kit
SPRING WASHER
M10, 4 pcs.
NUT
M10, 4 pcs.
CONTROL BOX (assy.)
17
8
210
156
234
250
192
2 -φ6
FIXING HOLE
R3
156
1-18
6
JUNCTION BOX
Fix the control box to bulkhead with four M10 bolts.
FIXING HOLE
TERMINAL
CABLE CLAMP
GND
TERMINAL
1-19
This page intentionally left blank.
1-20
2. WIRING
2.1 How to Use the Crimping Tool, Pin Extractor
A special crimping tool is necessary for connection of wires to the contact pins of the 38P
connector. The pin extractor removes the contact pin from the connector body. This
paragraph describes how to crimp and extract the contact pin.
Crimping Tool
06-1001-016
Contact Pin
60-8017-0313-00339F
(000-159-417-10)
Pin Extractor
06-1877-04
(000-519-595)
Crimping tool, contact pin, pin extractor
2.1.1 How to use the crimping tool
1. Remove the vinyl sheath by 3 to 4 mm to expose the
core.
2. Hold the crimping tool horizontally and insert the
contact pin with its slit facing downward into the crimp
hole on the crimping tool.
3. Insert the wire onto the contact pin and squeeze the
handle until the rachet releases. (The wire should be
placed deep enough into the contact pin so that its end
comes in contact with the stopper plate of the crimping
tool.) With crimping completed, pull the wire while
holding the contact pin to make sure that it is tightly
fastened.
2.1.2 How to use the pin extractor
If a contact pin is inserted into an incorrect hole on the
connector body, remove it with the pin extractor.
1. Push the pin extractor into the pin hole from the side
opposite to the pin inserting side.
2. Push in the head of the pin extractor. The retaining
spring comes free and the contact pin can be removed.
2-1
2.2 Wiring
Optional supply
*1 With monitor unit
MONITOR UNIT
FSV-2400
10S2076 (10 m)
10S2076 (10 m)
FSV-84
*1 No monitor unit
CONTROL UNIT FSV-8401
FSV-84
10S2074 (10 m) or 10S2075 (30 m)
CONTROL UNIT FSV-8401
Monitor
(Local supply)
Transceiver
unit
Monitor unit
Control unit
Monitor cable *1 Choose one
(Local supply)
Monitor unit
Control unit
External
monitor
*2: If connector may loosen by
vibration, monitor cable may also
be connected inside.
*1
Clamp in Processor Unit
PROCESSOR UNIT
FSV-8402
TRANSCEIVER UNIT
FSV-841A
10S1258 max. 100 m
DPYCY-1.5
100-115/
220-230 VAC
1φ, 50/60 Hz
Cables shown are JIS cables.
If not available, use equivalent.
See cross section diagrams of
cables in this section for cable
construction.
Hull Unit Control Box
(Separate installation
available with FSV-846
(option)).
10S2078 (8 m) *3
220 VAC
3φ, 50/60 Hz
TPYCY-4
DPYCYS-2.5
100/110/115/ 220/230 VAC
1φ, 50/60 Hz
HULL UNIT
FSV-8432
(800 mm stroke)
FSV-8442
(1100 mm stroke)
10S2320 (5 m)
*3 To connect cable 10S2078, connect the end where the peeled portion is
longer to the transceiver unit and connect the other end to the hull unit.
Wiring
2-2
Transducer cable
If the transducer cable is not quite long enough, unfasten the cable clamp shown in the
figure below to release the cable. This will allow a separation of 5 m between the hull unit
and transceiver (or junction box). With the cable fastened by the cable clamp, the units may
be separated from each other up to 4.5 m.
Transducer
cable
Unfasten this cable clamp.
Ground
Ground the processor unit and the hull unit, using an IV-8SQ wire or copper strap, to prevent
electrical shock. The monitor unit and transceiver unit also must be grounded, also with an
IV-8SQ wire or copper strap. Both the transceiver unit and the junction box (option) are
supplied with a copper strap.
Cable (10S2078) between hull unit and transceiver unit
The length of the cable between the hull unit and transceiver unit is 8 m. Arrange it as shown
below.
Clamp point
Clamp point
10S2078 (8 m)
Transceiver unit
side
0.38 m
7.2 m
0.07 m
Raise/lower control box
of the hull unit side
0.28 m
0.07 m
2-3
2.3 Monitor Unit (option)
2.3.1 Fabrication of cable from processor unit
One of the cables 10S2074 (10 m) or 10S2075 (30 m) runs between the processor unit
(FSV-8402) and the monitor unit (FSV-2400). Pass it through the cable clamp at the rear of
the monitor unit and connect.
SHIELD
ANTICORROSIVE SHEATH
30 11 12
13
29
28
14
10 1 2
15
27 9
3 16
26 8
4 17
25 7
6 5 18
24
19
23
22 21 20
1. GRY (No.1)
2. BLK/WHT
3. GRY (No.2)
4. BLK/RED
5. GRY (No.3)
6. BLK/GRN
7. GRY (No.4)
8. BLK/YEL
ARMOR
9. GRY (No.5)
10. BLK/BLU
11. BLK/BRN
12. BLK/PPL
13. WHT/RED
14. WHT/GRN
15. WHT/YEL
16. WHT/BLU
17. WHT/BRN
18. WHT/PPL
19. RED/GRN
20. RED/YEL
21. RED/BLU
22. RED/BRN
23. RED/PPL
24. GRN/YEL
25. GRN/BLU
26. GRN/BRN
27. GRN/PPL
28. YEL/BLU
29. YEL/BRN
30. YEL/PPL
1, 3, 5. 7, 9: Coaxial cables
Others:
Twisted pair cables
Cable 10S2074, sectional view
Fabrication of 38P connector 00-8016-038-313761HV (CN-A303)
250
45
40
Shield
Vinyl Sheath
Core
Anticorrosive
Sheath
Armor
Insulating Tape
After exposing cores,
wind shield around the armor.
Fabrication of cable for 38P connector 00-8016-038-313761HV
Guide Pin A
Guide Pin B
Position No.
Guide Pin A
(Large)
Assembling 38P connector
2-4
Guide Pin B
(Small)
Positioning guide pins
Guide pins of the connector identify the mating receptacle. They are;
• Guide pin A (Large): 4
• Guide pin B (Small): 1
Use the tool (Type: 10-910-0179-0) shown below to position guide pins.
Connector
Tool
CN-A303
Guide Pin
Guide Pin A (Large)
4
Guide Pin B (Small)
1
Guide pin insertion tool (notch in head)
Assembling BNC connector (CN-A304 to CN-A 308)
Housing Clamp Washer Nut
1. Remove vinyl sheath of the cable by 7.5 mm.
2. Pass the cable through the nut, washer, gasket and
clamp.
Center Pin Gasket
3. Unravel the shield and fold it back onto the clamp.
7.5
4. Remove the insulator, leaving 3 mm.
5. Trim the shield as shown in the drawing. Solder the
center chip to the conductor of the cable.
Shield
6. Pass the cable through the housing and tighten the
nut.
3
2-5
Assembling D-SUB connector (CN-A302)
1. Remove vinyl sheath of cores by 3 mm.
2. Pass the cores through shrink tubing (local supply).
3. Solder cores to connector pins referring to the interconnection diagram at the back of this
manual.
4. Assemble the connector.
Fold back shield onto cable,
and wrap with shield tape.
Cable clamp
Assembling D-sub connector
2.3.2 Connecting cable between processor unit and monitor unit
For the FURUNO-supplied monitor, connect the cable (10S2074 or 1022075) from the
processor unit (FSV-8402) to the CN-A302 – CN-A308 connectors on the monitor unit
(FSV-2400).
Attach connector from processor unit and control unit as below.
1.
2.
3.
4.
Unfasten four screws (M4×10) at the rear of the monitor to loosen the cable cover.
Lift and pull the cable cover to remove it.
Unfasten two screws (M4×10) to remove the clamp cover.
Lay the monitor and control cables on the clamp, and then reattach the clamp plate to fix
cables.
5. Connect eight connectors referring to the instruction sticker by the connector board.
6. Reattach the cable cover.
2-6
CN-A306 CN-A305 CN-A304
2
H
4
R
CN-A302
V
PROCESSOR
UNIT
CN-A301 CN-A303
CONTROL UNIT
Connector board
5
1
PROCESSOR UNIT
3
G
B
CN-A308 CN-A307
Cable from processor unit
(10S2074 or 10S2075)
Cable from control unit
(10S2076)
Clamp
Cable cover
Monitor unit, rear view
2-7
2.4 Processor Unit
Cables from the monitor unit, transceiver unit and other equipment are connected to the
CONE Board (10P6905) in the processor unit.
Group cables according to left side
and right side connection point and
bind each group with cable tie, 15 cm
from connector. Confirm that no stress
is placed on any cable when it is
plugged in.
15 cm
Cable tie
CN-A104
CN-A103
CN-A102
CN-A101
Processor unit, right side view
Processor unit
2-8
Processor unit, rear view
2.4.1 Cable from transceiver unit
This cable (10S1258) runs between the processor unit and transceiver unit (FSV-841). Pass
it through the cable clamp in the processor unit and connect it to CN-A101 on the CONE
Board.
Shield
Anticorrosive Sheath
1. BLK
2. BLK/BRN
3. BLK/RED
4. BLK/ORG
5. BLK/YEL
6. BLK/GRN
7. BLK/BLU
8. BLK/PPL
19 8 9
10
18 7 2 3 11
1 4
17 6
12
5
13
16
15 14
Armor
9. BLK/GRY
10. BLK/WHT
11. BRN/RED
12. BRN/ORG
13. BRN/YEL
14. BRN/GRN
15. BRN/BLU
16. BRN/PPL
17. BRN/GRY
18. BRN/WHT
19. RED/ORG
1:
Coaxial cable
2 to 19: Twisted pair cable
Cable type 10S12581, sectional view
Fabrication of 38P connector 00-8016-038-313761HV (CN-A101)
320
45
40
Shield
Vinyl Sheath
Core
Anticorrosive
Sheath
Armor
Insulating Tape
After exposing cores,
wind shield around the armor.
Fabrication of cable for 38P connector 00-8016-038-313761HV
Guide Pin A
Guide Pin B
Position No.
Guide Pin A
(Large)
Guide Pin B
(Small)
Assembling 38P connector
2-9
Positioning guide pins
Guide pins of the connector identify the mating receptacle. They are;
• Guide pin A (Large): 1
• Guide pin B (Small): 1
Use the tool (Type: 10-910-0179-0) shown below to position guide pins.
Connector
Tool
CN-A101
Guide Pin
Guide Pin A (Large)
4
Guide Pin B (Small)
1
Guide pin insertion tool (notch in head)
2.4.2 Power cable
Attach the NCS-253-P connector to the power cable (DPYCY-1.5 or equivalent) and connect
to the CN-A110 on the rear of the processor unit.
Cable DPYCY-1.5
Slip on heat-shrink tubing
or elastic tubing and heat.
Armor
Armor
Vinyl
sheath
Vinyl
sheath
Armor
#2
#3
#1
Solder
lead
wire
to armor
Solder
lead
wire
to armor
andand
connect
to #1
of connector.
connect
it toit #1
pinpin
of connector.
Vinyl
sheath
Taping
Taping
Use cable DPYCY-1.5
(Japan standard cable)
or equivalent cable.
Conductor
S = 1.5 mm2
φ = 1.56 mm
Assembling connector NCS-253-P
2.4.3 Cable from monitor unit
Connect the cable 10S2074 (10 m) or 10S2075 (30 m) from the monitor unit to the
connectors in the processor unit as shown below.
38P connector: CN-A103 (For the optional sub-monitor display, CN-A108)
D-sub 25 pin: CN-A102 (For the optional sub-monitor display, CN-A107)
D-sub 15 pin: CN-A104 (For the optional sub-monitor display, CN-A109)
2.4.4 Cable from control unit
For blackbox configuration, attach the cable (10S2076) from the control unit (FSV-8401) to
CN-A103 on CONE Board (10P6905) in the processor unit, passing it through the cable
clamp in the processor unit.
2-10
2.4.5 Optional equipment
Optional equipment (navigator, current indicator, AD converter, speed log, etc.) are
connected at the rear of the processor unit.
Use the SRCN connectors (optionally supplied, Type: CP10-04801, Code no.: 006-934-240)
to connect equipment to the rear of the processor unit.
Cable list
Outline of core
Simple
w/shield
Twisted
Sectional view of cables
02S8040
9 mm
Shield
No.
Color
1 WHT/BLU
2
BLK
3
PNK
4
GRN
5
ORG
6
YEL
7
RED
CO-SPEVV-SB-C 0.2sq, 5P
Shield
14 mm
No.
1
2
3
4
5
Color
YEL/BLK
YEL/WHT
YEL/RED
YEL/BLU
YEL/GRN
Armor
2-11
J5 (CIF1)
: SRCN6A13-5P
J7 (GYRO) : SRCN6A16-10P
J8 (LOG)
: SRCN6A13-3P
J10 (FNZ)
: SRCN6A21-10P
J13 (EXT-KP) : SRCN6A21-10S
Cable with armor
8 cm
2 cm
1 cm
Armor
Shield
3 mm
Vinyl sheath
Clamp fixing screw
Solder unused cores and
earth to braided shield.
Clamp
Solder earth wire.
Set screw
Wind shield
tape.
Connector case
Soldering side
Wind vinyl tape.
Attach conector at
shield to ground.
J9 (ES1)
: SRCN6A16-7P
J12 (ES2/NET): SRCN6A16-10P
Cable without armor
2 cm
3mm
Shield
Vinyl sheath
Solder unused cores and
earh wire to braided shieeld.
Clamp fixing screw
Clamp
Set screw
Vinyl sheath
Wind vinyl tape
Connector case
Soldering-side
2-12
Synchronizing with echo sounder or other sonar
To synchronize the transmission of the FSV-84 with an echo sounder or other type of sonar,
make connections as shown below.
• Current driven KP input
PROCESSOR
UNIT
EXT-KP
KP signal
8
9
EXT-KP-IN-H
EXT-KP-IN-C
Echosounder
Sonar
• Voltage driven KP input
PROCESSOR
UNIT
EXT-KP
KP signal
EXT-12VKP-IN
GND
10
7
Echosounder
Sonar
For KP sync with external echosounder/sonar make the following connections.
• Voltage driven KP output
Processor EXT-KP
unit
INTKP1
GND
INTKP2
GND
INTKP3
GND
KP signal
1
2
3
4
5
6
E/S
Sonar
Current
indicator
Menu setting
See EXT KP INPUT and EXT KP OUTPUT on the SYSTEM MENU/INTERFACE SETTING
menu according to other party. For further details, see page 3-8.
2-13
2.5 Transceiver Unit
2.5.1 Fabrication of 38P connector 00-8016-038-313761HV (CN-B101)
Pass the cable (10S2158) from the processor unit (FSV-8402) through the cable clamp on
the transceiver unit (FSV-841) and connect it to CN-B101.
400
45
40
Shield
Vinyl Sheath
Anticorrosive
Sheath
Armor
Core
Insulating Tape
After exposing cores,
wind shield around the armor.
Fabrication of cable for 00-8016-038-313761HV
Shorten the unused wires appropriately and treat their ends with vinyl tape to prevent short
circuit.
Guide Pin A
Guide Pin B
Position No.
Guide Pin A
(Large)
Guide Pin B
(Small)
Assembling 38P connector
Positioning guide pins
Use the tool (Type: 10-910-0179-0) shown below to position guide pins.
Connector
Tool
CN-B101
Guide Pin
2-14
Guide Pin A (large)
1
Guide Pin B (small)
1
Guide pin insertion tool (notch in head)
Power cable fabrication
Use power cable DPYCY-2.5 or equivalent.
140
(Power source side: 200)
35
30
FV2-4 (2 pcs.)
Anticorrosive
sheath
Armor
Vinyl sheath
Satellite compass cable fabrication
Use cable type TTYCS-1Q and connect it to TB B102.
300
30
5
Armor
Sheath
Braided shield
Wiring WAGO connector
Push down.
φ = 11.3 mm
Shield
Conductor
S = 0.75 mm 2
φ = 1.11 mm
Lever
Core
Twist
WAGO connector
Procedure
1. Twist core.
2. Insert lever and push down.
3. Insert core in hole.
4. Release lever.
5. Tug on wire to mark sure it is in place firmly.
2-15
P1
(64 pin)
P2
(64 pin)
TRX-1
TRX-16
Fix cables
by clamps.
CN-B101
TB-B10
CN-B102
Fix cables
by clamps.
Fasten shield with
steel clamp.
TB-B101
Clamp for transducer cables
Cable
No.
16
15
14
13
12
11
10
9
8
7
To Processor Unit
(cable 10S1258-1)
6
5
4
3
2
1
Arrange transducer cables as shown above and
fix them with clamp.
To Hull Unit
(cable 10S2078)
Satellite Compass
Power
Transceiver unit, inside view
Connect transducer cable (cables from transducer or cables from Junction Box FSV-845)
referring to cable no. labeled on the chassis and connector no. labeled on each pc board.
Connector is locked properly when you hear a “click” sound. For the cable (10S2078) from
the control box of the hull unit connect the longer peeled portion of the cable to the
transceiver unit.
Note: When removing or inserting TRX board when the transducer cable is not connected,
lock the connector lock of the transducer cable connector (HIF connector).
2-16
2.6 Control Box of Hull Unit
Connect the power cable TYPCY-4 (3φ) and the transceiver unit cable (10S2078, end with
shorter peeled portion) as shown below.
Sheath
100
25
20
M4 (YEL) x 3
FV5.5-4
Anticorrosiove
Clamp
sheath
armor.
Power cable
TPYCY-4
Vinyl sheath
Cable 10S2078
(from transceiver unit)
Armor
Vinyl
sheath
Conductor
S = 4 mm2
∅ = 2.55 mm
LED (Red)
For detection of phase reversal on
3 phase power cable
Confirm LED after completing the installation. The LED lights (in red) if power connection is
correct. If it is off, turn off power from the mains switchboard, reconnect any two lines of the
power cable, turn on the power, and check if the LED is lit. The hull unit does not work if this
connection is wrong.
Normal phase: LED lights (in red).
Phase reversal: LED does not light.
2-17
2.7 Input Voltage and Fuses
The transceiver unit is shipped from the factory with its input voltage set for 230 VAC and a
10 A fuse inserted in F601 and F602. For other voltages, change toggle switch positions and
fuses as below.
Input voltage
Set the toggle switches S603, S604 and S605 according to input voltage, referring to the
table below.
Input
(TB-B101)
100 VAC
110 VAC
115 VAC
220 VAC
230 VAC
S603
S604
S605
L
H
H
H
H
L
L
H
L
H
L
L
L
H
H
Default setting
Default setting
Fuses
Change the fuse in F601 and F602 according to input voltage, referring to the table below.
Input
(TB-B101)
100 VAC
110 VAC
115 VAC
220 VAC
230 VAC
Fuse
F601
F602
Default
setting
WARNING
Use the proper fuse.
20A
20A
10A
10A
Use of a wrong fuse can result in damage
to the equipment or cause fire.
Default
setting
Marking the label
After setting toggle switches and changing the fuses,
mark the label on the inside of the cover with the
voltage that applies. In the example shown right, 100
V is marked so 20A fuses must be used.
FUSE
FUSE
F601
F602
INPUT
(TB-B101)
FUSE
F601 F602
100V
110V
115V
220V
230V
2-18
20A
20A
10A
10A
2.8 Controller Extension Kit (Junction Box)
Wire the junction box of the controller extension kit as shown below.
Cable from TB-C101 in control box
Cable from TB-1 in control box
Cable from limit switch in hull unit
Cable from motor brake in hull unit
2-19
This page intentionally left blank.
2-20
3. ADJUSTMENT AND CHECK
3.1 Hull Unit Check
Setting transmission on
Default setting of transmission is OFF. Set the transmission on as follows:
Note: NEVER transmit when the vessel is in drydock.
1. Turn on the power, and then press the [MENU] key to show the main menu.
MENU
TX PULSE LENGTH-H
TX POWER-H
TVG-NEAR-H
TVG-MEDIUM-H
TVG-FAR-H
AGC-H
2ND AGC-H
ECHO AVERAGE-H
COLOR-H
COLOR RESPONSE-H
QUIT
:9
:9
:0
:0
:0
:0
:0
:0
: COLOR 1
: COLOR CURVE 3
User Menu
Settings change according
to user preference.
H-SCAN SETTING...
V-SCAN SETTING...
OTHERS...
Main menu
2. Use the trackball to choose OTHERS and press the [MENU] key.
MENU
QUIT
OTHERS
QUIT
ES1 SETTING...
ES2 SETTING...
ERASE MARKS...
DISPLAY SETTING...
ALARM & AUDIO...
PRESET, MEMORY CARD...
INITIAL SETTING...
OTHERS menu
3. Choose INITIAL SETTING and press the [MENU] key.
CAUTION
YES
THIS ITEM IS DEFINED AS NON-CHANGEABLE ITEM.
ARE YOU SURE TO CHANGE IT TO CHANGEABLE ?
NO
3-1
4. Choose YES and press the [MENU] key.
MENU
QUIT
OTHERS
QUIT
INITIAL SETTING
QUIT
MARK DISPLAY...
MARK SIZE...
DATA DISPLAY...
CURRENT VEC & WIND...
NET SONDE SETTING...
NET SHOOT SETTING...
TARGET LOCK...
STABILIZATION...
TEST...
INITIALIZATION...
INITIAL SETTING menu
5. Choose TEST and press the [MENU] key.
MENU
QUIT
OTHERS
QUIT
INITIAL SETTING
QUIT
TEST
BOARD TEST...
PANEL TEST...
TEST PATTERN...
RX TEST...
NOISE TEST...
TX
QUIT
: OFF
TEST menu
6. Choose TX and press the [MENU] key.
7. Choose ON and press the [MENU] key.
8. Choose QUIT at the top of the menu and press the [MENU] key.
How to check the hull unit
1. Press the POWER (|) switch on the control unit to turn on the equipment. Confirm that
“ ON” lamp above the POWER switch and theª switch light.
Transducer switches of the control unit
2. Confirm that the 5V and UP lamps on the raise/lower control box are lit.
3-2
3. Remove the cover of the raise/lower control box and use a multimeter to measure the
following voltages:
Terminal
TB-C101
Terminal No.
(1) – (2)
(2) – (3)
(1) – (3)
Voltage
220 VAC
220 VAC
220 VAC
4. In the raise/lower control box, set the TEST/NORMAL switch to TEST. Press the
[DOWN] switch to confirm that the transducer lowers. Also, while the transducer is being
lowered, check that the MD LED lights when the MD L. SW kicks. Note that the MD L.
SW does not stop the transducer when the TEST/NORMAL switch is in the TEST
position.
TEST
OFF
NORMAL
5V
L.SW
UP MD DN
UP
DOWN
Control unit (in hull unit)
5. Press and release the [DOWN] switch. Confirm that the transducer stops at the moment
the switch is released.
6. Press the [DOWN] switch again. Confirm that the transducer stops at the moment the
lower limit switch kicks.
7. Confirm that the [UP] switch operates in a similar manner.
8. Check that LEDs on the panel of the raise/lower control box light as follows:
1) UP, MD and DN LEDs light when corresponding limit switch is kicked.
2) UP and DN LEDs light while UP and DOWN switches are pressed and extinguish when
the switches are released.
9. Set the TEST/NORMAL switch to NORMAL.
10. At the control unit, press the ª (mid position) switch. Confirm that the lamp above the
switch blinks while the transducer is being lowered, a short beep sounds when the mid
limit switch kicks, and the lamp lights when the transducer is lowered to the mid position.
11. Press the ª switch (fully lowered position). Confirm that the lamp above the switch
blinks while the transducer is being lowered, a short beep sounds when the mid limit
switch is kicked, and the lamp lights when the transducer is fully lowered.
12. Press the OFF switch. Confirm that the transducer is completely retracted and then the
power is turned off.
13. Press the © switch. Confirm that the lamp above the switch blinks while the transducer
is being raised, a short beep sounds when the mid limit switch is kicked, and the lamp
lights when the transducer is fully raised.
14. With the transducer lowered (mid or fully lowered), confirm that the transducer is raised
when © or the OFF is pressed.
3-3
3.2 Heading Adjustment
When the BOW mark on the flange of the hull unit cannot be directed toward ship’s bow,
adjust the heading so an echo which is dead ahead appears dead ahead on the display.
1. Referring to the previous section, set the TX (transmission) to ON.
2. Locate a target in the bow direction (buoy, for example) and display it on a near range. If
the target appears at 12 o’clock the heading alignment is correct. If it does not, measure
the error and go to next step.
Buoy
If target's on-screen
position is right of ship's
bow for example, heading
is skewed left.
Heading adjustment
3. Turn off the power and then turn it on again while pressing and holding down the
[MENU] key. Release the [MENU] key after the self-test screen appears. After the picture
appears, press the [MENU] key three times to open the SYSTEM menu.
SYSTEM MENU
QUIT
INTERFACE SETTING...
EXT DATA SETTING...
OWN SHIP MARK...
TEST&INITIALIZATION...
TX/RX SETTING...
TX/RX SETTING-H...
TX/RX SETTING-V...
OTHERS...
SYSTEM menu
4. Use the trackball to choose OTHERS and press the [MENU] key.
5. Choose HEADING ADJUST1 and press the [MENU] key.
3-4
MENU
QUIT
OTHERS
QUIT
LANGUAGE
HEADING ADJUST1
HEADING ADJUST2
PROPELLER DIREC
ES2 SELECT
ES DRAFT OFFSET
EVENT KEY
AUTO TILT
SELECT USER PROG
TRACKBALL SPEED
HULL UNIT STROKE
: English
: 0°
QUIT
: 0°
CANCEL
: -180°
: ES
: 0.0m
: EVENT
: NARROW
:H/V INTERLOCK
: NORMAL
: 1100m
OTHERS menu, HEADING ADJUST
6. Choose ▲ or ▼ to choose direction (plus or minus, respectively) in which to increment
or decrement setting and then press the [MENU] key to set. Each pressing of the
[MENU] key changes the setting in increments of 1°. The setting range is -180° to +179°.
7. Choose QUIT to finish the adjustment and press the [MENU] key.
8. Choose QUIT at the top of the menu screen and press the [MENU] key to close all
menus.
Heading adjustment for motion sensor
HEADING ADJUST2 (on the SYSTEM menu) is used for heading adjustment of motion
sensor. Adjust the heading according to type of motion sensor connected, referring to the
guidelines below.
• If the standard motion sensor is used where the hull unit and control box are installed
together, use the same value as set for HEADING ADJUST1.
• If the control box is installed separately, set angle measured from bow. The angle is 0
degrees if the lid of the control box is directed toward ship’s stern precisely.
• If GPS gyro is selected as motion sensor, set 0 degrees.
3-5
3.3 Configuring Own Ship Mark
Set own ship’s dimensions and the location of the transducer to accurately display the own
ship mark on the display.
1. Press the [MENU] key to display the SYSTEM menu.
SYSTEM MENU
QUIT
INTERFACE SETTING...
EXT DATA SETTING...
OWN SHIP MARK...
TEST&INITIALIZATION...
TX/RX SETTING...
TX/RX SETTING-H...
TX/RX SETTING-V...
OTHERS...
System menu
2. Use the trackball to choose OWN SHIP MARK and press the [MENU] key.
MENU
QUIT
OWN SHIP MARK
QUIT
SHIP'S LENGTH
SHIP'S WIDTH
TD POSITION 1
TD POSITION 2
: 75m
: 20m
: 15m
: 0.0m
OWN SHIP MARK menu
3. Use the trackball to choose SHIP’S LENGTH.
4. Press the [MENU] key to show the setting window.
MENU
QUIT
OWN SHIP MARK
QUIT
SHIP'S LENGTH
SHIP'S WIDTH
TD POSITION 1
TD POSITION 2
: 75m
: 20m
: 15m
: 0.0m
QUIT
CANCEL
OWN SHIP MARK menu, setting window
3-6
5. Choose ▲ or ▼ and then operate the
[MENU] key to set the ship’s length
(15 to 150 m).
6. Choose QUIT to finish the setting.
7. Set the SHIP’S WIDTH (5 to 30 m), TD
POSITION 1 (5 to 50 m) or TD
POSITION 2 (-10.0 to 10.0 m)
similarly.
TD POSITION 1: Set the transducer’s
distance from the bow.
TD POSITION 2: Set the transducer’s
distance from the keel. Choose [+] for
starboard, [-] for port.
TD Position 1
Ship's
Length
TD Position 2
(Negative value
for port)
8. Choose QUIT at the top of the menu
screen and press the [MENU] key to
close all menus.
Ship's Width
Ship shape description
3.4 Other SYSTEM Menu Items
This section mainly shows you how to set up according to external equipment connected.
Default settings are underlined.
3.4.1 INTERFACE SETTING menu
MENU
QUIT
INTERFACE SETTING
Future use
NMEA 1 BAUD RATE
NMEA 2 BAUD RATE
CIF BAUD RATE
AUX BAUD RATE
SENSOR BAUD RATE
EXT KP INPUT
EXT KP OUTPUT
LAN SETTING...
QUIT
: 4800 bps
: 4800 bps
: 4800 bps
: 19200 bps
: 38400 bps
: DISABLE
: NEGATIVE
INTERFACE SETTING menu
NMEA 1 BAUD RATE: Set the transmission rate for the NMEA 1 port.
(4800 bps, 9600 bps, 19200 bps, 38400 bps)
NMEA 2 BAUD RATE: Set the transmission rate for the NMEA 2 port.
(4800 bps, 9600 bps, 19200 bps, 38400 bps)
3-7
CIF BAUD RATE: Set the transmission rate for the CIF port. If the CS-120A is connected,
choose “2400 bps”. (2400 bps, 4800 bps, 9600 bps, 19200 bps)
AUX BAUD RATE: Set the transmission rate for the AUX port. (2400 bps, 4800 bps, 9600
bps, 19200 bps)
SENSOR BAUD RATE: Set baud rate of satellite compass, connected to the transceiver
unit. (4800 bps, 9600 bps, 19200 bps, 38400 bps.) For SC-50/SC-110, select 38400 bps.
Note: Set NMEA output for SC-50/SC-110 as follows:
- Output format: IEC ed1
- Sentence: ATT, HVE (turn off all other sentences except those two)
- Baud rate: 38400 bps
- Interval: 25 ms
(Any talker)
EXT KP INPUT: Set the input logic of KP from external equipment. (DISABLE, ↑, ↓)
DISABLE: Disable external KP.
↑: Synchronize with leading edge of input pulse.
↓: Synchronize with trailing edge of input pulse
Note: To transmit with external KP, set the TX INTERNAL to “0” in the H-SCAN SETTING
menu.
EXT KP OUTPUT: Choose the KP output logic, POSITIVE or NEGATIVE. (POSITIVE,
NEGATIVE)
3.4.2 EXT DATA SETTING menu
MENU
QUIT
EXT DATA SETTING
DATE&TIME
HEADING
LOG PULSE
SPEED&COURSE
SPEED SENSOR
LAT/LON
POSITIONING SENSOR
WATER DEPTH
WATER TEMP.
WATER CURRENT
WIND
NET DEPTH
QUIT
: CIF
: AD10S
: 200p/NM
: NMEA
: GPS/DR
: NMEA
: AUTO SEL.
: NMEA
: NMEA
: CIF
: CIF
: PULSE
EXT DATA SETTING menu
DATE & TIME: Choose the input format for data and time data. (NONE, CIF, NMEA)
HEADING: Choose the input format for heading data. (NONE, AD10S, CIF, NMEA)
LOG PULSE: Set the log pulse rate for the log signal. (200 p/NM, 400 p/NM)
3-8
SPEED & COURSE: Choose the input format for ship’s speed and course data. When
choosing the LOG&HEADING, the heading data is used instead of the course data.
(NONE, LOG&HEADING, CIF, NMEA)
SPEED SENSOR: Choose the input format for speed and course data. This setting is
ineffective when LOG&HEADING is selected as speed and course source.
(NONE, GPS/DR, DOPPLER/DR)
LAT/LON: Choose the input format for ship’s position data. (NONE, CIF, NMEA)
POSITIONING SENSOR
Choose the type of the navigator to use. For AUTO SEL., the priority is GPS/DR>LORAN-C.
(LORAN-C, GPS/DR, AUTO SEL.)
WATER DEPTH: Choose the input format for depth data. (NONE, CIF, NMEA)
WATER TEMP.: Choose the input format for water temperature data. (NONE, CIF, NMEA)
WATER CURRENT: Choose the input format for water current data. (NONE, CIF, NMEA)
WIND: Choose the input format for wind data. (NONE, CIF, NMEA)
NET DEPTH: Choose the input format for net depth data. (NONE, CIF, PULSE)
3-9
Data sentences
NMEA Input sentences
Sentence
Main data source
Main data
GNS
GPS
Latitude, longitude
GGA
GPS
Latitude, longitude
RMA
Loran C
Latitude, longitude
RMC
GPS
Latitude, longitude, speed
GLL
GPS
Latitude, longitude
ZDA
GPS
Time, date
VBW
Ship speed, tide speed
Speed thru water, speed over ground
VHW
Tide speed
Speed thru water
VTG
GPS
True course, speed over ground
VDR
Tide speed
Tide speed and direction
HDT
Compass
Heading
HDM
Compass
Heading
HDG
Compass
Heading
HCD
Compass
Heading
HCC
Compass
Heading
DPT
Echo sounder
Depth
DBT
Echo sounder
Depth
DBS
Echo sounder
Depth
MTW
Echo sounder, Temperature indicator
Water temperature
MWV
Windmeter
Wind speed and direction
CUR
Current indicator
Tide speed and direction
NMEA output sentences
Sentence
Main data
TLL
Event, Net shoot, latitude and longitude of target mark
FKV
Fish school speed
TFM
Relative direction, distance, depth and speed of fish school
TLM
Relative direction, distance, depth of position mark
EVT
Bearing, distance and depth of event mark
FMG
Bearing, distance, depth and volume of estimate mark
FVC
Bearing, distance, depth and speed of fish school mark
SHT
Bearing and distance of net shoot mark
TLF
SV, area and volume of fish echo
SD3∼SD8
Scan setting parameters for each Tx and Rx
3-10
3.4.3 OTHERS menu
MENU
QUIT
OTHERS
QUIT
LANGUAGE
HEADING ADJUST1
HEADING ADJUST2
PROPELLER DIREC
ES2 SELECT
ES DRAFT OFFSET
EVENT KEY
AUTO TILT
SELECT USER PROG
TRACKBALL SPEED
HULL UNIT STROKE
TD TYPE
: English
:0
:0
: -180
: ES
: 0.0m
: EVENT
: NARROW
:H/V INTERLOCK
: NORMAL
: 800m
: NON-DOME
OTHERS menu
LANGUAGE: Choose the language to use. (JAPANESE, ENGLISH)
HEADING ADJUST1: See “3.2 Heading Adjustment”.
HEADING ADJUST2: Compensate for installation error in motion sensor (in hull unit) or
satellite compass, in bow direction. (-180 to 179(°)).
PROPELLER DIREC: Set bow reference bearing for screw as viewed from transducer
position. This is for suppressing screw noise, by specifying screw bearing. (-180 to 179(°)).
ES2 SELECT: Choose the equipment connected to the ES2 port; echo sounder or net
recorder. (ES, NET REC)
ES DRAFT OFFSET: When connecting an echosounder, you may enter the ship’s draft if
you prefer to display depth from the draft rather than depth from the transducer. (0.0 m to
10.0 m, increments of 0.1 m)
EVENT KEY: Choose the key to use to enter own ship’s position, EVENT or SHOOT. When
choosing SHOOT, the shoot function becomes inoperative. (EVENT, SHOOT)
AUTO TILT: Choose the range for the auto tilt form WIDE (±2 to 10°, ±4 to 16°, ±6 to 20°) or
NARROW (±1 to 4°, ±2 to 6°, ±3 to 8°). (WIDE, NARROW)
SELECT USER PROG: Choose whether to program horizontal and vertical displays
together or individually, by the USER PROG control. H/V INTERLOCK, the default setting,
commonly applies control settings to the horizontal and vertical displays. H/V INDVIDUAL
enables individual adjustment of horizontal and vertical displays.
3-11
TRACKBALL SPEED: Choose the speed of trackball movement (inside menu window only).
(SLOW, NORMAL, FAST)
HULL UNIT STROKE: Choose the stroke length of the hull unit. (800 mm, 1100 mm).
TD TYPE: Choose the type of transducer used: DOME.
3.5 CONE Board Setting in the Processor Unit
Adjust the potentiometers on the CONE Board in the processor unit, referring to the table
shown below.
Location
No.
R118
Name
ALARM
VOLUME
Resistance
value
10 kΩ
Function
Adjustment
Adjust the volume of
audio alarm.
CW: Large
CCW: Small
R119
ES2_OFFSET
1 kΩ
Adjust ES2 signal offset.
CW: Noise decrease
CCW: Noise increase
R167
ES2_GAIN
10 kΩ
Adjust ES2 signal gain.
R168
ES1_OFFSET
1 kΩ
Adjust ES1 signal offset.
R209
ES1_GAIN
10 kΩ
Adjust ES1 signal gain.
CW: Gain increase
CCW: Gain decrease
CW: Noise decrease
CCW: Noise increase
CW: Gain increase
CCW: Gain decrease
CW: Clockwise, CCW: Counterclockwise
3.5.1 Adjustment of signal level (echo sounder connected)
Adjusts the output level of the echo sounder on the CONE Board as below.
1. Choose an echo sounder display (ES1 or ES2) from the menu.
2. For ES1, adjust R168 to suppress noise, and then adjust R209 so that the picture
condition is similar to that of connected echo sounder connected to the FSV-84.
3. For ES 2, adjust R119 to suppress noise, and then adjust R167 so that the picture
condition is similar to that of echo sounder connected to the FSV-84.
3.5.2 Adjusting the volume of the audio alarm
The volume of the audio alarm cannot be adjusted from the control unit. If necessary, adjust
R118 on the CONE Board to choose appropriate volume.
3-12
3.6 DIP Switch Setting
J496, J497
AC
DC
96
4
J
97
J4
DCON board (10P6987)
IFES board (10P6903)
IFE
SS
CSAC
D
NAUN
A2DL
CO
N
J1
J1
Processor unit, inside view
3.6.1 CIF2/NMEA2 connector interface selection
The signal format for the CIF2/NMEA2 port (at the back of the processor unit) can be set for
CIF or NMEA by DIP switch S2-8 on the IFES Board (10P6903). The default format is OFF
(CIF).
DIP switch setting
S2-#8: ON
S2-#8: OFF
Format
NMEA
CIF
S2
IFES Board (10P6903)
3-13
3.6.2 Choosing echosounder signal
There are two kinds of echosounder signals, AC signal and DC signal. Set the appropriate
jumper on the CONE board (10P6905) as below according to the input port. The default
setting is AC. See previous for parts location.
Input port
ES1
ES2/NET
Jumper
J496
J497
Note: The SIGOUT (AC signal) terminal and REC terminal (DC signal) in the output port
are provided for a FURUNO echosounder. Therefore, when using the SIGOUT
terminal, it is not necessary to change the above-mentioned jumper setting.
3-14
4. CONNECTING EXTERNAL
INTERFACE CS-120A
The External Interface CS-120A functions to enable upgrading from a past CSH series sonar.
However, we recommend that you connect external devices directly to the processor unit, to
avoid signal delay. Connect echo sounder and net sonde directly to the processor unit.
Install the following power supply kit (option) in the processor unit to enable use of the
CS-120A.
Name:
Power Supply Kit
Type:
FSV-2403
Code No.: 000-067-013
Name
Type
Code No.
Qty
Power supply pcb
LEA50F-24-XFND
000-143-913
1
Spacer
SQ-22
000-802-742
4
Protection sheet
10-071-3508
100-290-712
1
Screw
M3×8 C2700W
000-881-404
4
Connector(NJC)
NJC-203-PM
000-506-702
1
Remarks
1. Unfasten seven screws to remove the front cover of the processor unit.
2. Unfasten two upset screws, detach the plugs J503, J502, J501, J504, J506 and J507,
and then pull out the power module.
Protection sheet
VH4P
Power supply
pcb
Spacer
Detach J503, J502,
J501, J504 and
VH5P J506.
IFE
S
SC
AN
SC
AN
2D
UA
L
DC
ON
Power Module
Upset screws
M5x25 SUS 2 pcs.
Pin
Hole
Detach J507.
Processor unit, front view
4-1
3. Fix the power supply pcb (supplied) to the power module with four spacers (supplied).
4. Connect two VH connectors (provided on the power module) to the power supply pcb.
5. Lay the protection sheet (supplied) on top of the spacers and fasten with pan head
screws (M3×8).
6. Reattach the power module.
7. Connect between the processor unit and CS-120A as follows.
PROCESSOR
UNIT
CS-120A
CS-120A
MJ-A3SPF0013-035
1
2
3
+24V_H
+24V_C
GND
YEL BRN
ORG BRN
PPL BRN
J201
L
E
PP
24V
0V
GND
NN
MM
JJ
KK
TD-H
TD-C
RD-H
RD-C
BB
EE
DD
Z
GND
DSR-C
DSR-H
DTR-H
OR NMEA2/CIF2
For CIF1
For CIF2
CIF_TXD_H
CIF_TXD_C
CIF_RXD_H
CIF_RXD_C
SHIELD
GND
1
2
3
4
5
6
37-core cable
10S1258
Wiring between processor unit and CS-120A
8. Set the DIP switch on the DCON Board as follows.
Input port
CIF1
NMEA2/CIF2
DIP switch setting on DCON Board
S3-#2: ON
S3-#3: ON
S3
DCON Board (10P6987)
For connection to NMEA2/CIF2 port, the #8 segment of S2 on the IFES board should be
OFF (CIF).
Note: If the CIF1 format is selected, change baud rate to 2400 bps. See CIF BAUD RATE
on page 3-8 for details.
4-2
+056#..#6+10/#6'4+#.5
#%%'5514+'5
52#4'2#465
70+6
176.+0'
%2
%2
(2
52
(58
36;
A-1
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%7:
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
%7: &'5%4+26+10%1&'ͳ
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ
Ꮏ੐᧚ᢱ
#%%'5514+'5
ઃዻຠ
ઃዻຠ
52#4'2#465
੍஻ຠ
੍஻ຠ
241%'551470+6
ᜰ␜ⵝ⟎೙ᓮㇱ
࡙࠾࠶࠻
0#/'
(58
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
%100'%614
0%5
㩄㩒㩂㩊
0%5
*':$1.6
5.166'&9#5*'4*'#&
౐ⷺ㩇㩢㩦㩢㩈㩛㩇$
%106#%62+0
㩄㩧㩊㩂㩎㩕㩩㩧㧔
%100'%614
㩄㩒㩂㩊
㧕
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
%1&'01 0%52
%1&'01 0%5241*5
/:575
%1&'01 /:575
(
%1&'01
*8(
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
%2
6;2'
೙ᓮㇱ↪
(14241%'551470+6
೙ᓮㇱ↪
(14241%'551470+6
೙ᓮㇱ↪
(14241%'551470+6
೙ᓮㇱ↪
(14241%'551470+6
↪ㅜ㧛஻⠨
4'/#4-5
%1: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%1:
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
%1&'01
A-2
数量
Q'TY
1
用途/備考
REMARKS
2
1
000-508-661
000-508-663
1
10CO-X-9406
FURUNO ELECTRIC CO .,LTD.
CODE NO.
SRCN6A16-10P
CODE NO.
SRCN6A13-5P
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
CONNECTOR(SRCN)
コネクタ(SRCN)
CONNECTOR(SRCN)
コネクタ(SRCN)
1
番 号
NO.
MEMORY CARD
メモリカード組品
略 図
OUTLINE
型名/規格
DESCRIPTIONS
FP10-02901
007-008-780
CODE NO.
007-008-790
FP10-02902
TYPE
CODE NO.
1
数量
Q'TY
1/1
10CT-X-9501
制御部用
FOR PROCESSOR UNIT
用途/備考
REMARKS
10CT-X-9501 -0
A-4
FURUNO ELECTRIC CO .,LTD.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
名 称
NAME
ACCESSORIES
名 称
NAME
型名/規格
DESCRIPTIONS
1/1
INSTALLATION MATERIALS
番 号
NO.
略 図
OUTLINE
10CO-X-9406 -2
付属品表
CP10-04506
TYPE
工事材料表
006-921-290
CODE NO.
A-3
㩕㨷㨺㩇㩨
(75'
()$1#
#%8
()$8
#2$(
2'4
8'5
ᜰ␜ⵝ⟎㧪೙ᓮㇱ↪
(14&+52.#;70+6
4'/#4-5%1&'01
%1:
52#4'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪ
ᄌࠊࠅ߹ߖࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'
722'4241&7%637#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕
&9)01
2'4
5'6
914-+0)
37#06+6;
5'652'4
8'55'.
$1:012
52
75'
6;2'
&9)01
14
6;2'01
(74701'.'%64+%%1.6&
176.+0'
52#4'2#465.+56(14
0#/'1(
2#46
/(450#/'
+6'/
01
5*+201
%1: %1&'01
A-5
0#/'
#%%'5514+'5
70+6
176.+0'
(2
(2
(58
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%7:
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
36;
A-6
%7: &'5%4+26+10%1&'ͳ
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
#%%'5514+'5
ઃዻຠ
ઃዻຠ
%10641.70+6
ᠲ૞ㇱ
࡙࠾࠶࠻
(58,,'
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
47$$'4(''6
ࠧࡓ⿷
*':$1.6
9#5*'4*'#&
㨻㩖㩩㩈㨹㩎7+㩈㩛㩇$
18#.*'#&5%4'9
㧗㩅㩡ዊ㩒㩆㩨
(.#69#5*'4
㩚㩀㩨㩁ᐔᐳ㊄
524+0)9#5*'4
ࡃࡀᐳ㊄
*':076
౐ⷺ㩏㨹㩎㧝⒳
&7//;(+./
㩄㩒㩂㩊㩆㨺㩣
&756%18'4-$
㩊㩨㩇㩎㩀㩔㩨㨺-$
-$(+:0)2.#6'
-$⋥ઃߌ㊄ౕ
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
%1&'
01
5,㩂㩥
5,㩂㩥
%1&'
01
/:575
%1&'
01
/:%9/$0+
%1&'
01
/%2/$0+
%1&'
01
/%9/$0+
%1&'
01
/%9/$0+
%1&'
01
%1&'
01
%1&'
01
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
(2
6;2'
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
ᠲ૞ㇱ↪
(14%10641..70+6
↪ㅜ㧛஻⠨
4'/#4-5
%1: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%1:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
#%%'5514+'5
ઃዻຠ⴫
%1&'01
A-7
0#/'
176.+0'
&1%7/'06
+056#..#6+10/#6'4+#.5
52#4'2#465
70+6
15'
%
+/
1/
%2
52
(58#$
36;
A-8
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%7:
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪉㪅㩿㪁㪈㪀䈱࿑ᦠ䈲䇮⧷ᢥ઀᭽䈱䉂ᔅⷐ䈪䈜䇯
㩿㪁㪈㪀㩷㪠㪪㩷㪦㪥㪣㪰㩷㪩㪜㪨㪬㪠㪩㪜㪛㩷㪝㪦㪩㩷㪜㪥㪞㪣㪠㪪㪟㩷㪪㪧㪜㪚㪠㪝㪠㪚㪘㪫㪠㪦㪥㪅
%7: &'5%4+26+10%1&'ͳ
㪈㪅䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
12'4#6145)7+&'
ᠲ૞ⷐ㗔ᦠ
+0276,1.6#)'5'66+0)
㔚Ḯ⸳ቯᦠ
+056#..#6+10/#07#.
ⵝ஻ⷐ㗔ᦠ
12'4#6145/#07#.
ขᛒ⺑᣿ᦠ
࿑ᦠ
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ
Ꮏ੐᧚ᢱ
52#4'2#465
੍஻ຠ
੍஻ຠ
64#05%'+8'470+6
ㅍฃାⵝ⟎
࡙࠾࠶࠻
(58#$
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
%122'4564#2
㨻㨺㩇᧼
%4+/210.7)
࿶⌕┵ሶ
%106#%62+0
㩄㩧㩊㩂㩎㩕㩩㩧
1100'%614
㩄㩒㩂㩊
6'4/+0#.12'0'4
ᠲ૞㩤㩔㩨㨺
%100'%614
㩄㩒㩂㩊
㧕
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
%1&'
01
9'#
%1&'
01
(8㨻㨿
%1&'
01
(
%1&'
01
(74
%1&'
01
%1&'
01
*8(
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
%2
6;2'
↪ㅜ㧛஻⠨
4'/#4-5
%7: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%7:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
(58#$
%1&'01
A-9
㩕㨷㨺㩇㩨
(75'
㩕㨷㨺㩇㩨
(75'
㩕㨷㨺㩇㩨
(75').#55
67$'6;2'
㩕㨷㨺㩇㩨
(75'
()$1#
#%8
()$#%8
#2$(
()$1#
#%8
()$8#
()$18#
2$(
()/$8#
2$(
&9)01
14
6;2'01
2'4
8'5
&9)01
2'4
5'6
914-+0)
52#4'
%6: 5'652'4
8'55'.
$1:012
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪ
ᄌࠊࠅ߹ߖࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'
722'4241&7%637#.+6;+56*'5#/'
ㅍฃାⵝ⟎↪
(1464#05%'+8'470+6
ㅍฃାⵝ⟎↪
(1464#05%'+8'470+6
ㅍฃାⵝ⟎↪
(1464#05%'+8'470+6
ㅍฃାⵝ⟎↪
(1464#05%'+8'470+6
4'/#4-5%1&'01
%6:
37#06+6;
75'
52
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕
(74701'.'%64+%%1.6&
176.+0'
52#4'2#465.+56(14
0#/'1(
2#46
/(450#/'
+6'/
01
5*+201
6;2'
%1&'01
A-10
ᢙ㊂
36;
ㅍฃାⵝ⟎㧙਄ਅⵝ⟎
↪ㅜ㧛஻⠨
4'/#4-5
%#$.'#55'/$.;
㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55'/$.;
㩃㨺㩖㩨㩣⚵ຠ
ฬ‫ޓޓ‬⒓
0#/'
+056#..#6+10/#6'4+#.5
⇟ภ
01
⇛‫ޓޓ‬࿑
176.+0'
%1&'01
5/
%1&'01
*+(885$*+(./
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%2
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
%7: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%1:
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%7:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
%1&'01 5
5
ဳฬ㧛ⷙᩰ
&'5%4+26+105
Ꮏ੐᧚ᢱ⴫
(58
6;2'
%1&'01
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
⇛‫ޓޓ‬࿑
176.+0'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
%#$.'#55;
㩃㨺㩖㩨㩣㧔⚵ຠ㧕
ฬ‫ޓޓ‬⒓
0#/'
(585
%1: A-12
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
%1&'01
6;2'
A-11
%#$.'#55'/$.;
㩃㨺㩖㩨㩣⚵ຠ
%#$.'#55'/$.;
㩃㨺㩖㩨㩣⚵ຠ
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
%1&'01
5/
%1&'01
*+(885$*+(./
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
%2
6;2'
↪ㅜ㧛஻⠨
4'/#4-5
%7: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%7:
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
(58
%1&'01
A-13
0#/'
&1%7/'06
+/
(58.6
(58.&6
52
52
(58
36;
A-14
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%7:
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㩿㪁㪈㪀䈱⃻࿾⚵ㇱຠ䈲઀᭽䈮䉋䉍ㆬᛯ㗿䈇䉁䈜䇯
㪁㪈㪑㪚㪟㪦㪦㪪㪜㩷㪦㪥㪜㩷㪘㪚㪚㪦㪩㪛㪠㪥㪞㩷㪫㪦㩷㪪㪧㪜㪚㪠㪝㪠㪚㪘㪫㪠㪦㪥㪅
%7: &'5%4+26+10%1&'ͳ
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
+056#..#6+10/#07#.
ⵝ஻ⷐ㗔ᦠ
࿑ᦠ
.1%#.#55'/$.+0)2#465%1/2.'6'
5'6
⃻࿾⚵ㇱຠ▫⹣ຠ
176.+0'
.1%#.#55'/$.+0)‫ޓ‬2#465
52#4'2#465
70+6
.1%#.#55'/$.+0)2#465%1/2.'6'
5'6
⃻࿾⚵ㇱຠ▫⹣ຠ
⃻࿾⚵ㇱຠ
52#4'2#465
੍஻ຠ
੍஻ຠ
*7..70+6
਄ਅⵝ⟎
࡙࠾࠶࠻
(586(586
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
࡙࠾࠶࠻
&1%7/'06
.1%#.#55'/$.+0)‫ޓ‬2#465
52#4'2#465
70+6
176.+0'
+/
(58.&
(58.
52
(580(580
36;
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩
%7:
A-15
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍਄Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏౉䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
㪉㪅䋨㪁㪈䋩䈱⃻࿾⚵ㇱຠ䈲઀᭽䈮䉋䉍ㆬᛯ㗿䈇䉁䈜䇯
㪁㪈㪅㪚㪟㪦㪦㪪㪜㩷㪦㪥㪜㩷㪘㪚㪚㪦㪩㪛㪠㪥㪞㩷㪫㪦㩷㪪㪧㪜㪚㪠㪝㪠㪚㪘㪫㪠㪦㪥㪅
%7: &'5%4+26+10%1&'ͳ
㪈㪅䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍ⴫䍘䍎䍢䍼䉕⴫䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
+056#..#6+10/#07#.
ⵝ஻ⷐ㗔ᦠ
࿑ᦠ
.1%#.#55'/$.+0)‫ޓ‬2#465
%1/2.'6'5'6
⃻࿾⚵ㇱຠ▫⹣ຠ
.1%#.#55'/$.+0)‫ޓ‬2#465
%1/2.'6'5'6
⃻࿾⚵ㇱຠ▫⹣ຠ
⃻࿾⚵ㇱຠ
52#4'2#465
੍஻ຠ
੍஻ຠ
*7..70+6
਄ਅⵝ⟎
0#/'
(580(580
㧼㧭㧯㧷㧵㧺㧳‫ޓ‬㧸㧵㧿㨀
(75'
㩕㨷㨺㩇㩨
()/$#8
()/$8#
2$(
2'4
8'5
਄ਅⵝ⟎
೙ᓮེ↪
(14*#..70+6
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌ
ࠊࠅ߹ߖࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'
722'4241&7%637#.+6;+56*'5#/'
5'652'4
8'55'.
4'/#4-5%1&'01
%1:
52#4'
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)‫(ޓ‬144'('4'0%'10.;㧕
&9)01
2'4
5'6
914-+0)
37#06+6;
75'
52
6;2'
&9)01
14
6;2'01
(74701'.'%64+%%1.6&
176.+0'
52#4'2#465.+56(14
0#/'1(
2#46
/(450#/'
+6'/
01
5*+201
%1: $1:012
%1&'01
A-16
⇟ภ
01
%1&'01
/:575
%1&'01
/:%9/$0+
%1&'01
/:575
%1&'01
/575
%1&'01
/575
%1&'01
/575
%1&'01
(8
%1&'01
%#
%1&'01
%1&'01
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%7:
⇛‫ޓޓ‬࿑
176.+0'
6196;2'5#0&%1&'5/#;$'.+56'&6*'$1661/241&%6/#;$'5*+22'&+02.#%'1(6*'612241&7%637#.+6;
6*'5#/'
9+0)$1.6
Ⲕ㩘㩨㩣㩎‫ޓ‬㩆㨷
9#5*'4*'#&5%4'9
㩏㩗㩨㩈㩛㩇㩒㩆㩨#
*':#)10#.*'#&5%4'9
౐ⷺ㩘㩨㩣㩎‫ోޓ‬㩒㩆㩨
524+0)9#5*'4
㩔㩨㩒ᐳ㊄
(.#69#5*'4
㩚㩀㩨㩁ᐔᐳ㊄
*':076
౐ⷺ㩏㨹㩎㧝⒳
%4+/210.7)
࿶⌕┵ሶ
14+0)
1㩢㩧㩂㩨
*#0&.'(+:+0)2.#6'
㩔㩧㩎㩨㩣࿕ቯ᧼
*#0&.'(+:+0)2.#6'
㩔㩧㩎㩨㩣࿕ቯ᧼
ฬ‫ޓޓ‬⒓
0#/'
%7: %7:
⇟ภ
01
(58.6
6196;2'5#0&%1&'5/#;$'.+56'&6*'$1661/241&%6/#;$'5*+22'&+02.#%'1(6*'612241&7%637#.+6;
6*'5#/'
↪ㅜ㧛஻⠨
4'/#4-5
.1%#.#55'/$.+0)2#465
⃻࿾⚵ㇱຠ
(58.6
6;2'
%1&'01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢߤߜࠄ߆߇౉ߞߡ޿߹ߔ‫ޔ߅ߥޓޕ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
ᢙ㊂
36;
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%1&'01
40.
%1&'01
/:575
%1&'01
/:%9/$0+
%1&'01
/:575
%1&'01
/575
%1&'01
/575
%1&'01
/575
%1&'01
(8
%1&'01
%1&'01
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%7: ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢߤߜࠄ߆߇౉ߞߡ޿߹ߔ‫ޔ߅ߥޓޕ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
⇛‫ޓޓ‬࿑
176.+0'
਄ਅⵝ⟎‫ࠢࡦ࠲ޔࠅ᦭ࡓ࡯࠼ޓ‬ήߒ
(58.
6;2'
A-18
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
4#6%*'694'0%*
ਔญ㩡㩋㨴㨹㩎㩤㩧㩋
9+0)$1.6
Ⲕ㩘㩨㩣㩎‫ޓ‬㩆㨷
9#5*'4*'#&5%4'9
㩏㩗㩨㩈㩛㩇㩒㩆㩨#
*':#)10#.*'#&5%4'9
౐ⷺ㩘㩨㩣㩎‫ోޓ‬㩒㩆㩨
524+0)9#5*'4
㩔㩨㩒ᐳ㊄
(.#69#5*'4
㩚㩀㩨㩁ᐔᐳ㊄
*':076
౐ⷺ㩏㨹㩎㧝⒳
%4+/210.7)
࿶⌕┵ሶ
*#0&.'(+:+0)2.#6'
㩔㩧㩎㩨㩣࿕ቯ᧼
*#0&.'(+:+0)2.#6'
㩔㩧㩎㩨㩣࿕ቯ᧼
ฬ‫ޓޓ‬⒓
0#/'
.1%#.#55'/$.+0)2#465
⃻࿾⚵ㇱຠ
(58.
%1&'01
A-17
⇟ภ
01
⇛‫ޓޓ‬࿑
176.+0'
%1&'01
40.
ဳฬ㧛ⷙᩰ
&'5%4+26+105
ᢙ㊂
36;
(58.6
6;2'
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
%7:
6196;2'5#0&%1&'5/#;$'.+56'&6*'$1661/241&%6/#;$'5*+22'&+02.#%'1(6*'612241&7%637#.+6;
6*'5#/'
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢߤߜࠄ߆߇౉ߞߡ޿߹ߔ‫ޔ߅ߥޓޕ‬ຠ⾰ߪᄌࠊࠅ߹ߖࠎ‫ޕ‬
↪ㅜ㧛஻⠨
4'/#4-5
%7: 㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
4#6%*'694'0%*
ਔญ㩡㩋㨴㨹㩎㩤㩧㩋
ฬ‫ޓޓ‬⒓
0#/'
.1%#.#55'/$.+0)2#465
⃻࿾⚵ㇱຠ
(58.6
%1&'01
A-19
%100'%614
54%0
㩄㩒㩂㩊
54%0
%100'%614
54%0
㩄㩒㩂㩊
54%0
%100'%614
54%0
㩄㩒㩂㩊
54%0㧕
%100'%614
54%0
㩄㩒㩂㩊
54%0㧕
%100'%614
54%0
㩄㩒㩂㩊
54%0㧕
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
%1&'
01
54%0#5
%1&'
01
54%0#2
%1&'
01
54%0#2
%1&'
01
54%0#2
%1&'
01
54%0#2
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%2
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
%1: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%1:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
+056#..#6+10/#6'4+#.5
Ꮏ੐᧚ᢱ⴫
6;2'
%1&'01
A-20
5
4
3
2
1
⇟ ภ
NO.
WASHER
ᛮߌᱛ߼㩦㨹㩆㨶
SCREW
+㩎㩡㩇㩒㩆㩨
FILTER
CRT㩖㨲㩣㩊㨺
SPACER
㩙㩁㩇㩗㩩㨺㩅㨺
HOOD RETAINER
㩖㨺㩎㩨㩕㩨㩇
ฬ‫ޓޓ‬⒓
NAME
ACCESSORIES
ઃዻຠ⴫
000-808-429
100-266-311
100-289-020
000-801-878
000-808-430
ᢙ㊂
Q'TY
⴫␜ㇱ↪‫ޓޓޓ ޓ‬
FOR MONITOR UNIT‫ޓ‬
⴫␜ㇱ↪‫ޓޓޓޓޓޓ‬
FOR MONITOR UNIT
2
10CO-X-9503
⴫␜ㇱ↪‫ޓޓޓޓޓ‬
FOR MONITOR UNIT‫ޓ‬
⴫␜ㇱ↪‫ޓޓޓޓޓޓ‬
FOR MONITOR UNIT‫ޓޓ‬
2 ‫ޓ‬
1
2
2
⴫␜ㇱ↪‫ޓޓޓޓޓޓ‬
FOR‫ޓ‬MONITOR UNIT
↪ㅜ㧛஻⠨
REMARKS
1/1
㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰.
CODE NO.
TM-147-3
CODE NO.
M5X10 C2700W
CODE NO.
10-071-1141-0
CODE NO.
5X2.5
CODE NO.
03-144-1336-1
ဳฬ㧛ⷙᩰ
DESCRIPTIONS
FP10-02202
TYPE
10CO-X-9503 -0
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫ޓޕ‬DIMENSIONS IN DRAWING FOR REFERENCE ONLY.㧕
⇛‫ޓޓ‬࿑
OUTLINE
006-924-320
CODE NO.
A-21
&756%18'4
㩊㩨㩇㩎㩀㩔㩨㨺%46
ฬ‫ޓޓ‬⒓
0#/'
⇛‫ޓޓ‬࿑
176.+0'
ဳฬ㧛ⷙᩰ
&'5%4+26+105
%1&'
01
(455$(4㨺
59&5$59/5#)&
)2(58
‫ޓޓޓޓޓ‬
ᢙ㊂
36;
↪ㅜ㧛஻⠨
4'/#4-5
(5: 㧲㨁㧾㨁㧺㧻‫ޓ‬㧱㧸㧱㧯㨀㧾㧵㧯‫ޓ‬㧯㧻‫ޓ‬㧚㧘㧸㨀㧰
㧔⇛࿑ߩኸᴺߪ‫ޔ‬ෳ⠨୯ߢߔ‫&ޓޕ‬+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
(5:
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐ว‫ޔ‬ਅᲑࠃࠅ਄Ბߦઍࠊࠆㆊᷰᦼຠߢ޽ࠅ‫ޔ߅ߥޓޕߔ߹޿ߡߞ౉߇߆ࠄߜߤޔ‬ຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎ‫ޕ‬
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
241&7%637#.+6;+56*'5#/'
⇟ภ
01
#%%'5514+'5
ઃዻຠ⴫
6;2'
%1&'01
A-22
A-23
D-1
D-2
D-3
D-4
D-5
D-6
D-7
D-8
D-9
D-10
Nov.22'06
T.Matsuguchi
D-11
Nov.22'06 T.Matsuguchi
D-12
D-13
D-16
D-14
D-15
Mar.14'07 R.Esumi
1
2
CN-C101
200-220VAC,3φ,50/60Hz
A
*3 VV-SBCJ-0.3x14P,8m,φ17
A
ミドリ GRN
(10S2078)
アカ
RED
アオ
BLU
クロ
BLK
ムラサキ PPL
シロ
WHT
チャ
BRN
TT
クロ
BLK
チャ
BRN
*1
シロ
WHT
TB-C101
TPYCY-4
U 1
アオ
BLU
V 2
シロ
WHT
W 3
キ
YEL
4
クロ
BLK
5
シロ
WHT
6
クロ
BLK
7
ムラサキ PPL
8
クロ
BLK
アカ
RED
シロ
WHT
*1
制御器
PE IV-8sq.
ミドリ GRN
FSV-8420/8421 保護アース
クロ
BLK
アカ
RED
クロ
BLK
上下装置
ミドリ GRN
HULL UNIT
WHT
シロ
FSV-8431/8433
キ
YEL
FSV-8441/8443
シロ
WHT
B
FSV-8432/8442
10S2320,10m,φ10.7
距離:5m以下
DISTANCE: MAX.5m
送受波器
TRANSDUCER
FSV-8422/8423
C
*1
TTYCS-1
DATA_OUT1-5
サテライトコンパス TD-A 1
SATELLITE COMPASS TD-B 2
SC-50/110
3
4
GND 5
100/110/115/
220/230 VAC
1φ,50/60Hz
*1
DPYCY-2.5
上下装置構成
CONFIGURATION OF HULL UNIT
MOTION
TYPE
SENSOR TRAVEL TRANSDUCER
FSV-8431
国内向
800
FSV-8433
JAPAN ONLY
FSV-8422
FSV-8441
(ドーム付)
1100
FSV-8443
D
国外向
OUT OF JAPAN
FSV-8432
800
FSV-8442
1100
FSV-8423
P
P
P
P
P
P
P
P
P
P
P
P
P
P
CN-B102
J1 *3 *4
A MSRXD-H
B MSRXD-C
C MSTXD-H
D MSTXD-C
E UPLSW-H
F UPLSW-C
H DEMGUP-H
LL DEMGUP-C
J MDLSW-H
K MDLSW-C
N DNLSW-H
P DNLSW-C
R DNCMD-H
S DNCMD-C
T UPCMD-H
U UPCMD-C
V DUPLSW-H
X DUPLSW-C
W TSFLG-H
Y TSFLG-C
Z MSROLL
AA MSR_GND
BB MSPITCH
CC MSP_GND
JJ PWRHUL-H
NN PWRHUL-C
PP PWRHUL-H
TT PWRHUL-C
3
4
*3 *4
10S2075,30m,φ25
10S2074,10m,φ25
チャ 17 BRN
シロ 17 WHT
ムラ 18 PPL
シロ 18 WHT
ミドリ 19 GRN
アカ 19 RED
CN-A103(108)
CN-A101
10S1258,MAX.100m,φ18
*5 J411(421)
*4 J445
A
A TRXRXD-H
アカ 11 RED
P
B
B TRXRXD-C
チャ 11 BRN
C
C TRXTXD-H
クロ 10 BLK
P
D
D TRXTXD-C
シロ 10 WHT
E
E SIG_D0-H
ダイ 12 ORG
P
F
F SIG_D0-C
チャ 12 BRN
H
H DEMGUP-H
アカ 19 RED
P
J
LL DEMGUP-C
ダイ 19 ORG
K
J SIG_D1-H
クロ
9 BLK
P
L
K SIG_D1-C
ハイ
9 GRY
M
L SIG_D2-H
キ
13 YEL
P
N
M SIG_D2-C
チャ 13 BRN
P
N SIG_D3-H
クロ
8 BLK
P
R
P SIG_D3-C
ムラサキ
8 PPL
S
R SIG_D4-H
ダイ
4 ORG
P
T
S SIG_D4-C
クロ
4 BLK
U
T SIG_D5-H
クロ
3 BLK
P
V
U SIG_D5-C
アカ
3 RED
W
V DUPLSW-H
キ
5 YEL
P
X
X DUPLSW-C
5 BLK
クロ
Y
W AUDIO-H
チャ
2 BRN
P
Z
Y AUDIO-C
2 BLK
クロ
MM
Z +12V
ミドリ
6 GRN
P
AA GND
6 BLK
クロ
PP
BB EXTKP-C
シールド SHIELD
JJ
CC EXTKP-H
シンセン
CORE
RR
DD SIG_D6-H
ミドリ 14 GRN
P
EE SIG_D6-C
KK
チャ 14 BRN
SS
FF SIG_D7-H
クロ
7 BLK
P
NN
HH SIG_D7-C
アオ
7 BLU
TRX 10P7010x16
TT
JJ KP-H
アオ 15 BLU
P
*3
LL
KK KP-C
チャ 15 BRN
*3 *5
B201
MM FS-H CN-A102(107)
チャ 18 BRN
P
P1~P2
XM2ANN FS-C
シロ 18 WHT
J413(423)
2501
PP ENB-H
1
ムラサキ 16 PPL
P
RR EMB-C
14
チャ 16 BRN
B216
SS FSCLK-H
3
チャ 17 BRN
P
P1~P2
TT FECLK-C
6
ハイ 17 GRY
5
18
送受信装置
制御部
4
TRANSCEIVER UNIT
PROCESSOR UNIT
17
FSV-841A
FSV-8402
7
CN-B103
19
8
1 TD-H
20
2 TD-C
2
3 RD-H
23
4 RD-C
12
9
13
10
POWER
24
TB-B101
21
1 AC_IN-H
25
2 AC_IN-C
22
*5
CN-A104(109)
*3
アース銅板
J412(422) KEC-15P
COPPER STRAP
DS1V-R 1
CN-A110
WEA-1004-0
*1 NCS-253P J16
GND 6
100-115/
DPYCY-1.5
3 AC_IN-H
DS1V-G 2
220-230VAC
2 AC_IN-C
GND 7
1φ,50/60Hz
1 SHIELD
DS1V-B 3
GND 8
DS1VSY 14
GND 5
DS1HSY 13
GND 10
CN-B101
J2 *4
A
B
C
D
E
F
H
LL
J
K
L
M
N
P
R
S
T
U
V
X
W
Y
Z
AA
BB
CC
DD
EE
FF
HH
JJ
KK
MM
NN
PP
RR
SS
TT
キ
アカ
アオ
アカ
チャ
アカ
ムラサキ
アカ
キ
ミドリ
ミドリ
NOTE
*1: SHIPYARD SUPPLY.
*2: OPTION.
*3: CONNECTOR PLUGS FITTED AT FACTORY.
*4: 00-8016-038-313761HVF
*5: ( ): FOR SUB MONITOR UNIT.
20
20
21
21
22
22
23
23
24
24
25
YEL
RED
BLU
RED
BRN
RED
PPL
RED
YEL
GRN
GRN
P
P
P
P
P
P
P
アオ 25 BLU
チャ 26 BRN
ミドリ 26 GRN
ムラサキ
ミドリ
アオ
キ
チャ
キ
ムラサキ
キ
27
27
28
28
29
29
30
30
PPL
GRN
BLU
YEL
BRN
YEL
PPL
YEL
ムラサキ
クロ
アカ
シロ
チャ
クロ
アオ
クロ
ミドリ
シロ
キ
シロ
アオ
シロ
キ
クロ
ミドリ
クロ
アカ
クロ
シロ
クロ
12
12
13
13
11
11
10
10
14
14
15
15
16
16
8
8
6
6
4
4
2
2
PPL
BLK
RED
WHT
BRN
BLK
BLU
BLK
GRN
WHT
YEL
WHT
BLU
WHT
YEL
BLK
GRN
BLK
RED
BLK
WHT
BLK
P
P
P
P
XM2A2501
1
14
3
6
5
18
4
17
7
19
8
20
2
23
12
9
13
10
24
21
25
22
P
P
P
P
P
P
P
P
P
P
P
ドウジク① COAX.
ドウジク② COAX.
ドウジク③ COAX.
ドウジク④ COAX.
ドウジク⑤ COAX.
DRAWN
Mar. 20 '07
CHECKED
Mar. 20 '07
APPROVED
+12V
GND
+12V
GND
+12V
GND
+12V
GND
PP
JJ
RR
KK
SS
NN
TT
LL
P
BNC-P
1
2
BNC-P
1
2
BNC-P
1
2
BNC-P
1
2
BNC-P
1
2
T.YAMASAKI
CN-A302
J513
DS1SPK-H
GND
DS1DVS-N
GND
-12V
-12V
+12V
+12V
DS1HALLX
GND
DS1HALLY
GND
DS1DGN-N
NC
+140V
GND
+140V
GND
+140V
GND
+140V
GND
J521
DS1V-R
GND
J522
DS1V-G
GND
J523
DS1V-B
GND
J524
DS1VSY
GND
J525
DS1HSY
GND
6
CN-A301
J531 *3 *4
CN1RXD-H A
CN1RXD-C B
CN1TXD-H C
CN1TXD-C D
CN1TXA-H E
CN1TXA-C F
CN1TXB-H J
CN1TXB-C K
CN1TYA-H L
CN1TYA-C M
CN1TYB-H N
CN1TYB-C P
GND JJ
GND KK
GND LL
CN-A303
J511 *4
CN1RXD-H
CN1RXD-C
CN1TXD-H
CN1TXD-C
CN1TXA-H
CN1TXA-C
NC
CN1TXB-H
CN1TXB-C
CN1TYA-H
CN1TYA-C
CN1TYB-H
CN1TYB-C
CN1PON-H
CN1PON-C
CN1POF-H
CN1POF-C
CN1AUDV1
NC
CV1AUDV2
NC
CN1AUDV3
GND
A
B
C
D
E
F
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
MM
P
P
PE
*1
IV-8sq.
保護アース
注記
*1)造船所手配。
*2)オプション。
*3)コネクタは工場にて取付済み。
*4)00-8016-038-313761HVF
*5)( ):副表示部用。
5
CN1PON-H
CN1PON-C
CN1POF-H
CN1POF-C
CN1AUDV1
CN1AUDV2
CV1AUDV3
CN1BRLV1
CN1BRLV2
CN1BRLV3
+12V
GND
+12V
GND
NC
NC
R
S
T
U
V
X
Z
W
Y
CC
PP
MM
RR
NN
SS
TT
10S2076,5m
P
P
P
P
P
P
P
P
P
P
P
P
P
P
MONITOR UNIT
FSV-2400
CN-A304
CN-A305
CN-A306
CN-A307
CN-A308
*1
IV-8sq.
TITLE
Mar.28'07 R.Esumi
SCALE
MASS
kg
DWG No.
C1329-C01- D
CN-A201
*3
J1(XH15P)
3 CN1RXD-H 操作部
4 CN1RXD-C CONTROL UNIT
1 CN1TXD-H FSV-8401
2 CN1TXD-C
5 CN1TXA-H
6 CN1TXA-C
7 CN1TXB-H
8 CN1TXB-C
9 CN1TYA-H
10 CN1TYA-C
11 CN1TYB-H
12 CN1TYB-C
13 GND
14 GND
15 GND
CN-A202
*3
J2(XH14P)
1 CN1PON-H
2 CN1PON-C
3 CN1POF-H
4 CN1POF-C
5 CN1AUDV1
6 CN1AUDV2
7 CN1AUDV3
8 CN1BRLV1
9 CN1BRLV2
10 CN1BRLV3
11 +12V
13 GND
12 +12V
14 GND
表示部
名称
T.TAKENO
S-1
NAME
FSV-84
カラースキャニングソナー
相互結線図
COLOR SCANNING SONAR
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
1
(10/20m *2)
VV-SBCJ-0.3x14P,8m,φ17
A
ミドリ GRN
(10S2078)
アカ
RED
アオ
BLU
クロ
BLK
ムラサキ PPL
シロ
WHT
チャ
BRN
TT
クロ
BLK
チャ
BRN
*1
シロ
WHT
TB-C101
TPYCY-4
U 1
アオ
BLU
V 2
シロ
WHT
W 3
キ
YEL
4
クロ
BLK
5
シロ
WHT
6
クロ
BLK
7
ムラサキ PPL
8
クロ
BLK
アカ
RED
シロ
WHT
*1
制御器
PE IV-8sq.
ミドリ GRN
FSV-8420/8421 保護アース
クロ
BLK
アカ
RED
クロ
BLK
上下装置
ミドリ GRN
HULL UNIT
WHT
シロ
FSV-8431/8433
キ
YEL
FSV-8441/8443
シロ
WHT
CN-C101
*3
200-220VAC,3φ,50/60Hz
A
2
B
P
P
P
P
P
P
P
P
P
P
P
P
P
P
FSV-8432/8442
送受波器
TRANSDUCER
FSV-8422/8423
C
*3
B201
B101
B216
B116
(J1-16) (J1-16)
接続箱 FSV-845
JUNCTION BOX *2
アース銅板
COPPER STRAP
距離:5m標準(FSV-84)
DISTANCE: MAX.5m FOR FSV-84
(延長キット使用で最大20m)
(FSV-84Lのみ)
*1
TTYCS-1
DATA_OUT1-5
サテライトコンパス TD-A 1
SATELLITE COMPASS TD-B 2
3
SC-50/110
4
GND 5
*1
DPYCY-2.5
上下装置構成
CONFIGURATION OF HULL UNIT
MOTION
TYPE
SENSOR TRAVEL TRANSDUCER
FSV-8431
国内向
800
FSV-8433
JAPAN ONLY
FSV-8422
FSV-8441
(ドーム付)
1100
FSV-8443
国外向
OUT OF JAPAN
CN-B101
J2 *4
A
B
C
D
E
F
H
LL
J
K
L
M
N
P
R
S
T
U
V
X
W
Y
Z
AA
BB
CC
DD
EE
FF
HH
TRX 10P7010x16
JJ
*3
KK
B201
MM
P1~P2
NN
PP
RR
B216
SS
P1~P2
TT
振動子ケーブル延長キット
TRANSDUCER CABLE EXTENSION KIT
100/110/115/
220/230 VAC
1φ,50/60Hz
D
HIF/VVS66/HIF
-L5/15M,5/15m,φ10
10S2320,10m,φ10.7
*3
CN-B102
J1 *3 *4
A MSRXD-H
B MSRXD-C
C MSTXD-H
D MSTXD-C
E UPLSW-H
F UPLSW-C
H DEMGUP-H
LL DEMGUP-C
J MDLSW-H
K MDLSW-C
N DNLSW-H
P DNLSW-C
R DNCMD-H
S DNCMD-C
T UPCMD-H
U UPCMD-C
V DUPLSW-H
X DUPLSW-C
W TSFLG-H
Y TSFLG-C
Z MSROLL
AA MSR_GND
BB MSPITCH
CC MSP_GND
JJ PWRHUL-H
NN PWRHUL-C
PP PWRHUL-H
TT PWRHUL-C
FSV-8432
800
FSV-8442
1100
注記
*1)造船所手配。
*2)オプション。
*3)コネクタは工場にて取付済み。
*4)00-8016-038-313761HVF
*5)( ):副表示部用。
3
10S1258,MAX.100m,φ18
アカ 11 RED
チャ 11 BRN
クロ 10 BLK
シロ 10 WHT
ダイ 12 ORG
チャ 12 BRN
アカ 19 RED
ダイ 19 ORG
クロ
9 BLK
ハイ
9 GRY
キ
13 YEL
チャ 13 BRN
クロ
8 BLK
ムラサキ
8 PPL
ダイ
4 ORG
クロ
4 BLK
クロ
3 BLK
アカ
3 RED
キ
5 YEL
5 BLK
クロ
チャ
2 BRN
2 BLK
クロ
ミドリ
6 GRN
6 BLK
クロ
シールド SHIELD
シンセン
CORE
ミドリ 14 GRN
チャ 14 BRN
クロ
7 BLK
アオ
7 BLU
アオ 15 BLU
チャ 15 BRN
チャ 18 BRN
シロ 18 WHT
ムラサキ 16 PPL
チャ 16 BRN
チャ 17 BRN
ハイ 17 GRY
4
CN-A101
*4 J445
A TRXRXD-H
B TRXRXD-C
C TRXTXD-H
D TRXTXD-C
E SIG_D0-H
F SIG_D0-C
H DEMGUP-H
LL DEMGUP-C
J SIG_D1-H
K SIG_D1-C
L SIG_D2-H
M SIG_D2-C
N SIG_D3-H
P SIG_D3-C
R SIG_D4-H
S SIG_D4-C
T SIG_D5-H
U SIG_D5-C
V DUPLSW-H
X DUPLSW-C
W AUDIO-H
Y AUDIO-C
Z +12V
AA GND
BB EXTKP-C
CC EXTKP-H
DD SIG_D6-H
EE SIG_D6-C
FF SIG_D7-H
HH SIG_D7-C
JJ KP-H
KK KP-C
MM FS-H
NN FS-C
PP ENB-H
RR EMB-C
SS FSCLK-H
TT FECLK-C
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
送受信装置
制御部
TRANSCEIVER UNIT
FSV-841A(FSV-84)
FSV-841B(FSV-84L)
1
2
3
4
PROCESSOR UNIT
FSV-8402
CN-B103
TD-H
TD-C
RD-H
RD-C
POWER
TB-B101
1 AC_IN-H
2 AC_IN-C
*1 NCS-253P
100-115/ DPYCY-1.5
220-230VAC
1φ,50/60Hz
アース銅板
COPPER STRAP
WEA-1004-0
3
2
1
CN-A103(108)
*5 J411(421)
CN1RXD-H A
CN1RXD-C B
CN1TXD-H C
CN1TXD-C D
CN1TXA-H E
CN1TXA-C F
CN1TXB-H J
CN1TXB-C K
CN1TYA-H L
CN1TYA-C M
CN1TYB-H N
CN1TYB-C P
GND JJ
GND KK
GND LL
CN1PON-H
CN1PON-C
CN1POF-H
CN1POF-C
CN1AUDV1
CN1AUDV2
CV1AUDV3
CN1BRLV1
CN1BRLV2
CN1BRLV3
+12V
GND
+12V
GND
NC
NC
5
P
P
P
P
P
P
P
P
P
P
P
P
P
P
*5
CN-A104(109)
J412(422) KEC-15P
DS1V-R 1
GND 6
DS1V-G 2
GND 7
DS1V-B 3
GND 8
DS1VSY 14
GND 5
DS1HSY 13
GND 10
VGA CABLE
S-2
CN-A201
*3
J1(XH15P)
3 CN1RXD-H
操作部
4 CN1RXD-C
CONTROL UNIT
1 CN1TXD-H
FSV-8401
2 CN1TXD-C
5 CN1TXA-H
6 CN1TXA-C
7 CN1TXB-H
8 CN1TXB-C
9 CN1TYA-H
10 CN1TYA-C
11 CN1TYB-H
12 CN1TYB-C
13 GND
14 GND
15 GND
CN-A202
*3
J2(XH14P)
1 CN1PON-H
2 CN1PON-C
3 CN1POF-H
4 CN1POF-C
5 CN1AUDV1
6 CN1AUDV2
7 CN1AUDV3
8 CN1BRLV1
9 CN1BRLV2
10 CN1BRLV3
11 +12V
13 GND
12 +12V
14 GND
10S2076,5m
R
S
T
U
V
X
Z
W
Y
CC
PP
MM
RR
NN
SS
TT
6
*1
*1
外部モニター
EXT. MONITOR
CN-A110
J16
AC_IN-H
AC_IN-C
SHIELD
PE
*1
IV-8sq.
保護アース
FSV-8423
NOTE
*1: SHIPYARD SUPPLY.
*2: OPTION.
*3: CONNECTOR PLUGS FITTED AT FACTORY.
*4: 00-8016-038-313761HVF
*5: ( ): FOR SUB MONITOR UNIT.
DRAWN
Mar. 20 '07
CHECKED
Mar. 20 '07
APPROVED
T.YAMASAKI
TITLE
名称
T.TAKENO
Mar.28'07 R.Esumi
SCALE
MASS
kg
DWG No.
C1329-C04- D
NAME
FSV-84/84L(BB)
カラースキャニングソナー(BBタイプ)
相互結線図
COLOR SCANNING SONAR (BB TYPE)
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
C
B
A
BRN
RED
ORG
YEL
GRN
BLU
PPL
GRY
WHT
BLK
チャ
アカ
ダイ
キ
ミドリ
アオ
ムラサキ
ハイ
シロ
クロ
リミット
スイッチ
LIMIT
SWITCH
TB-D102
TB-D101
制御器延長キット
CONTROL BOX
EXTENSION KIT *2
FSV-846
注記
*1)造船所手配。
*2)オプション。
*3)コネクタは工場にて取付済み。
*4)00-8016-038-313761HVF
NOTE
*1: SHIPYARD SUPPLY.
*2: OPTION.
*3: CONNECTOR PLUGS FITTED AT FACTORY.
*4: 00-8016-038-313761HVF
FSV-8432/8442
FSV-8431/8433
FSV-8441/8443
上下装置 HULL UNIT
YEL
GRN
RED
WHT
BLK
キ
ミドリ
アカ
シロ
クロ
モーター
ブレーキ
MOTOR
BRAKE
上下動部
RAISE/LOWER UNIT
FSV-8430/8440
1
1
2
3
4
5
6
7
8
9
10
4
5
6
7
8
DWG No.
SCALE
APPROVED
T.TAKENO
C1329-C02- D
MASS
kg
FSV-84/84L
TB-C101
U
V
W
BRAKE
BRAKE
MOTOR U
MOTOR V
MOTOR W
送受信装置
INTERCONNECTION DIAGRAM
CONTROL BOX EXTENSION KIT
相互結線図
制御器延長キット
FSV-846
*3 *4
TRANSCEIVER UNIT
J1 CN-B102
A
MSRXD-H FSV-841A(FSV-84)
B
MSRXD-C FSV-841B(FSV-84L)
C
MSTXD-H
D
MSTXD-C
E
UPLSW-H
F
UPLSW-C
H
DEMGUP-H
LL DEMGUP-C
J
MDLSW-H
K
MDLSW-C
N
DNLSW-H
P
DNLSW-C
R
DNCMD-H
S
DNCMD-C
T
UPCMD-H
U
UPCMD-C
V
DUPLSW-H
X
DUPLSW-C
W
TSFLG-H
Y
TSFLG-C
Z
MSROLL
AA MSR_GND
BB MSPITCH
CC MSP_GND
JJ PWRHUL-H
NN PWRHUL-C
PP PWRHUL-H
TT PWRHUL-C
4
FURUNO ELECTRIC CO., LTD.
NAME
名称
TITLE
10S2078 (10/20m: FSV-84L)
J1 *3 *4 VV-SBCJ-0.3x14P,8m,φ17
A
1
ミドリ GRN
P
2
アカ
RED
3
アオ
BLU
P
4
BLK
クロ
5
ムラサキ PPL
P
6
シロ
WHT
7
チャ
BRN
P
8
クロ
BLK
TT
チャ
BRN
P
TB-1
シロ
WHT
アオ
BLU
1 UP-LMT-SW1-H
P
シロ
WHT
2 UP-LMT-SW1-C
YEL
キ
3 UP-LMT-SW2-H
P
クロ
BLK
4 UP-LMT-SW2-C
シロ
WHT
5 MD-LMT-SW-H
P
クロ
BLK
6 MD-LMT-SW-C
ムラサキ PPL
7 DN-LMT-SW2-H
P
クロ
BLK
8 DN-LMT-SW2-C
アカ
RED
9 DN-LMT-SW1-H
P
WHT
シロ
10 DN-LMT-SW1-C
ミドリ GRN
P
クロ
BLK
PE
*1
RED
アカ
P
IV-8sq.
クロ
BLK
保護アース
ミドリ GRN
P
WHT
シロ
キ
YEL
P
シロ
WHT
FSV-8420/8421 CN-C101
T.YAMASAKI
P
P
P
P
P
3
制御器 CONTROL BOX
Mar.28'07 R.Esumi
Mar. 20 '07
Mar. 20 '07
10S2336,5m *2
クロ
BLK
キ
YEL
シロ
WHT
キ
YEL
アカ
RED
キ
YEL
アオ
BLU
キ
YEL
ミドリ GRN
キ
YEL
CHECKED
DRAWN
*1
TPYCY-4
10S2337,5m *2
アカ/チャ RED/BRN
シロ/クロ WHT/BLK
アカ(太) RED (B)
シロ(太) WHT (B)
クロ(太) BLK (B)
200-230VAC
1φ,50/60Hz
2
S-3
1
2
PCS-E68PM
データ収録装置
DATA RECORDER
メンテナンス専用
FOR MAINTENANCE
魚探 I/F
ES I/F
VI-1100A
J14 PC IF
1
*4
A
*2
SRCN6A16-10P
02S8040,6m
68
1
2
3
4
5
6
7
8
9
10
*4
*2
*2 SRCN6A21-10S
外部KP CO-0.2x5P
1
EXTERNAL KP
2
3
4
5
6
7
8
9
10
*4
B
外部スピーカ
EXTERNAL SPEAKER
SEM-21Q
1
2
3
4
5
6
7
8
2.8m
1
2
NJC-203PM
CS-120A
1
2
3
C
SRCN2A21-16S
注記
*1)造船所手配
*2)オプション。
*3)コネクタは工場にて取付済み。
*4)コネクタクランプでアースに落とす。
*5)IFES基板S2 #8にて選択。
工場出荷時はCIF(OFF)。
D
NOTE
*1: SHIPYARD SUPPLY.
*2: OPTION.
*3: CONNECTOR PLAG FITTED AT FACTORY.
*4: GROUND THRU CONNECTOR CLAMP.
*5: SELECT CIF OR NMEA AT S2 #8 ON
IFES BOARD. DEFAULT IS CIF (OFF).
DRAWN
Dec. 26 '06
CHECKED
APPROVED
SCALE
DWG.No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
16
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
TITLE
名称
TAKAHASHI. T
kg
C1318-C03- N
FSV-2402/2402S/3002/3002S/8402
制御部外部信号接続
相互結線図
FSV-24/24S/30/30S/84/84L
MASS
S-4
MONITOR J1
KEC-15P
外部モニター
MD-R 1
EXTERNAL MONITOR
制御部
GND 6
2
MD-G
PROCESSOR UNIT
GND 7
FSV-2402/2402S
MD-B 3
FSV-3002/3002S
GND 8
FSV-8402
MD-V-SYNC 14
GND 5
J12 ES2/NET
MD-H-SYNC 13
ES2-SIG-IN
GND 10
GND
*4
KP-DN-IN
*3
*2
NC
NMEA1 J3
MJ-A6SPF
MJ-A6SPF0011/0012 航法装置
NMEA1-TXD-H 1
ES2-WL-IN
5/10m,φ6
NAVIGATOR
NMEA1-TXD-C 2
GND
GND
NMEA1-RXD-H 3
KP-UP-IN
NMEA1-RXD-C 4
*4
NC
SHIELD 6
GND
*3
*2
NMEA2/CIF2 J4
MJ-A6SPF
MJ-A6SPF0011/0012 航法装置
*5
NMEA2-TXD-H 1
J13 EXT-KP
5/10m,φ6
NAVIGATOR
INTKP1
NMEA2-TXD-C 2
NMEA2-RXD-H 3
GND
NMEA2-RXD-C 4
INTKP2
SHIELD 6
GND
*4
INTKP3
*2
SRCN6A13-5P
GND
CIF1 J5
CO-0.2x2P
GND
CIF-TXD-H 1
潮流計
P
EXT-KP-IN-H
CIF-TXD-C 2
CURRENT INDICATOR
EXT-KP-IN-C
CIF-RXD-H 3
P
EXT-12VKP-IN
CIF-RXD-C 4
SHIELD 5
*4
J15 CN-A105
AUX J6
17JE-13260-02(D1)
パソコン
NC 1
PC
AUX-TXD 2
メンテナンス専用
AUX-RXD 3
FOR MAINTENANCE
GND 7
NC 25
*4
*2
*2
SRCN6A16-10P
GYRO J7
CO-0.2x2P ADコンバータ
CN-A106
AD-DATA-H 2
AD CONVERTER
P
SP-AUDIO
AD-DATA-C 3
AD-100
GND
AD-CLK-H 6
P
AD-CLK-C 7
SHIELD 10
J17 CS-120A
*4
+24VDC
*2
*1
0V
LOG J8 SRCN6A13-3P
DPYC-1.5
スピードログ
LOG 1
SHIELD
SPEED LOG
GND 2
3
NC
*4
J11 FNZ-AUX
SONDE_3 予備
*2
*2
SRCN6A16-7P
GND
ES1 J9
RESERVE
02S8040,6m 魚探I/F
SONDE_4
ES1-SIG-IN 1
ES I/F
GND
GND 2
VI-1100A
SONDE_5
ES1-KP-IN 3
GND
NC 4
SONDE_6
ES1-WL-IN 5
GND
SHIELD 6
SONDE_7
GND 7
*4
GND
*2
*1
SRCN6A21-10P
SONDE_8
FNZ J10
CO-0.2x5P ネットゾンデ
GND
SONDE_0 1
NET SONDE
SONDE_9
GND 2
GND
SONDE_1 3
GND
GND 4
SONDE_2 5
GND 6
SONDE_KP 7
GND 8
SONDE_WL 9
GND 10
*4
E.MIYOSI
Y. Hatai
3
NAME
PROCESSOR UNIT EXTERNAL INTERFACE
INTERCONNECTION DIAGRAM