large three-phase squirrel cage asynchronous

LARGE THREE-PHASE SQUIRREL CAGE
ASYNCHRONOUS MOTORS
AD SERIES
FRAMES 355 ÷560
400kW ÷ 1500kW (1500rpm)
FOR INVERTER DUTY
Code C-AD-355-560-E-11
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Declaration of conformity
The motors described in this catalogue satisfy the essential requisites of the following Directives:
- 72/23/EEC Low Voltage Directive
Reference has also been made to the following directives, specifically for the reasons listed as follows:
- EMC 89/336/EEC (Electromagnetic Compatibility) Directive
- 2006/42/CE Machinery Directive
The electric motors/generators are components that are incorporated into other machines, systems and plants and
therefore the resulting EMC behaviour is under the responsibility of the Manufacturer of the machine or plant
incorporating the motor/generator.
With reference to the 2006/42/EC Directive, it must be specified that the motors/generators must be installed in
compliance with the installation instructions and cannot be put into service until the machine in which they are
incorporated has been declared in compliance with the 2006/42/EC Machinery Directive.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 2 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
SICMEMOTORI, among the European leaders for variable speed applications, presents this series of large threephase heavy duty asynchronous motors, expressly designed for inverter duty.
Designing and manufacturing characteristics, together with materials utilised for the construction of these motors,
make this series one of the most advanced actually available on the market
Main technical features
Frames 355÷560
Squirrel cage rotor
Class F insulation
Class F temperature rise when inverter supplied
Class B temperature rise when grid connected
Insulation and impregnation expressly designed for inverter duty
Insulated bearing
Dimensions according to IEC 60072 Std.
Ratings and performances according to IEC 60034-1Std.
Degree of protection IP55 (IEC 60034-5 Std.)
Type of cooling IC411 and IC416 (IEC 60034-6 Std.)
Terminal box (degree of protection IP55) on top
Mounting arrangements IM1001 (B3), IM2001 (B35), IM3011(V1) and derivated (IEC 60034-7 Std.)
Half-key balancing
Metallic name plate
Low noise level (IEC 60034-9 Std.)
Constant torque speed regulation (with inverter supply) down to 25Hz for IC411 selfventilated motors
Constant torque speed regulation (with inverter supply) down to 5Hz for IC416 forced ventilated motors
Constant power speed regulation (with inverter supply) up to 75Hz (max. speed must be compatible with table at
page 11).
Final colour grey RAL7031
All motors are in conformity with European Directives and are CE marked.
Motors can run(when grid connected) with voltage variation of ± 10% and frequency variation of ± 5% with a
maximum combined variation of ± 10%, with temperature rise in compliance with IEC Standards.
Sound pressure
Motor type
3000
1500
AD 355
AD 400
AD 450
AD 500
AD 560
94
95
93
-----
87
88
93
94
97
Synchronous speed (rpm)
1000
750
Sound pressure level (dBA)
80
75
82
78
89
84
90
90
90
89
600
500
70
73
80
88
86
70
73
77
88
80
Bearings
Motor
type
AD 355
AD 400
AD 450
AD 500
AD 560
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
Mounting B3 (IM1001) – B35 (IM2001)
Non Drive End
Drive End
Non Drive End
Insulated bearing
Ball
Roller
Ball
Ball
6317 C3
--6317 C3
6317 MC3 VL0241
6322 C3
NU322
6322 C3
6322 MC3 VL0241
6317 C3
--6317 C3
6317 MC3 VL0241
6326 C3
NU326
6326 C3
6326 MC3 VL0241
6220 C3
--6220 C3
6320 MC3 VL0241
6328 C3
NU328
6328 C3
6328 MC3 VL0241
--------6330 C3
NU330
6330 C3
6330 MC3 VL0241
--------6334 C3
NU334
6330 C3
6330 MC3 VL0241
Mounting V1 (IM3011)
Drive End
Non Drive End
Ball
--6322 C3
--6326 C3
--6328 C3
--6330 C3
--6334 C3
Ball
--7322B
--7326B
--7328B
--7330B
--7330B
Transport locking: all motors with an “NU bearing” or an “Angular contact bearing” are fitted with a transport
locking device to prevent damage to the bearings due to vibrations during transport.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 3 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Frequency drive: for all motors driven by a frequency converter an insulated bearing at the NDE side is mounted.
For motors in V1 mounting, the insulated bearing Is mounted at the DE side, and the “angular contact bearing” at
the NDE side
All AD motors are supplied with insulated bearing as standard
Inverter duty
The AD series AC motors are designed and manufactured expressely for inverter duty, referring to the IEC
guidelines (EN60034-25).
VPI impregnation assures the maximum performances and together with the insulated materials and the upgraded
special double coated copper wire give the best possible behaviour when the motors are supplied by vector-control
inverter.
It is advisable that max dV/dt at motor terminals is 2kV/µsec (voltage 400V) or 1,5kV/µsec (690V).
Ratings and technical data
The tables of technical data are referred tocontinuous duty S1, an ambient temperature of 40°C and an altitude up
to 1000 m.a.s.l..
In different environmental conditions output ratings vary, and are obtainable by applying the factors showed in table
6, maintaining the temperature rise within the B insulation class (F insulation class when inverter supplied).
Altitude
m.a.s.l.
<= 1000
1500
2000
3000
4000
30
1.06
1.04
1
0.96
0.91
30-40
1
0.97
0.95
0.89
0.84
Ambient temperature (°C)
45
50
0.97
0.94
0.94
0.91
0.92
0.88
0.86
0.82
0.80
0.76
55
0.90
0.87
0.84
0.78
0.72
60
0.87
0.84
0.81
0.74
0.67
Rated Power
Rated current
Rated speed
Rated torque
Power factor
Efficiency
Istart/In
Tstart/Tn
Moment of inertia
Weight
:
:
:
:
:
:
:
:
:
:
Weight
η (%)
Moment of
inertia
J
Cosø
Tmax/Tn
Nm
Tstart/Tn
rpm
Istart/In
Efficiency
690V
(A)
Power
factor
400V
(A)
Rated
torque
Tn
(kW)
Rated
speed
Rated
power
AD
Rated
current
In
Motor type
Technical data tables key-words
(Kgm 2 )
(kg)
Nominal mechanical power to the motor shaft
Nominal current
Nominal speed
Nominal torque at the motor shaft
Power factor at full load
Efficiency at full load
Starting current versus Nominal current
Starting torque versus Nominal torque
Rotor inertia
Motor weight
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 4 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
LARGE 3-PHASE AC MOTORS FOR INVERTER DUTY OR GRID CONNECTED
TECHNICAL DATA
1140
1285
1445
1606
1796
2020
2277
2561
2881
0,90
0,90
0,90
0,90
0,90
0,90
0,90
0,90
0,90
95,6
95,6
95,8
95,8
95,5
95,6
95,6
95,6
96,0
7,0
7,0
7,0
7,0
7,5
7,5
7,5
7,5
7,5
1,6
1,6
1,6
1,6
1,2
1,2
1,2
0,8
0,8
2,0
2,0
2,0
2,0
2,6
2,6
2,6
2,0
2,0
Tstart/Tn
Tmax/Tn
Weight
2975
2975
2975
2975
2980
2980
2980
2985
2985
Moment of
inertia
J
η (%)
Tmax/Tn
Cosø
Tstart/Tn
Nm
Istart/In
rpm
Istart/In
355
400
450
500
560
630
710
800
900
Efficiency
XA2
XB2
XC2
XD2
XA2
XB2
XC2
XA2
XB2
690V
(A)
345
389
437
485
545
613
690
778
872
Power
factor
355
355
355
355
400
400
400
450
450
400V
(A)
596
674
756
840
944
1061
-------
Rated
torque
Tn
(kW)
Rated
speed
Rated
power
AD
Rated
current
In
Motor type
2 Poles - 50Hz - 3000rpm
(Kgm 2 )
(kg)
5,0
5,3
5,9
6,4
8,6
9,6
11,0
28,8
32,5
2100
2180
2340
2520
3200
3490
3660
5000
5200
Nm
Cosø
η (%)
1485
1485
1485
1485
1490
1490
1490
1490
1490
1490
1490
1490
1490
1490
2284
2574
2896
3217
3591
4040
4553
5130
5772
6413
7182
8016
8978
9619
0,87
0,87
0,87
0,87
0,89
0,89
0,89
0,87
0,87
0,87
0,88
0,88
0,89
0,89
95,7
95,7
95,8
95,8
96,0
96,0
96,2
95,6
96,0
95,5
95,6
95,7
95,6
95,6
7,0
7,0
7,0
7,8
7,0
7,0
7,0
7,5
7,5
7,0
7,5
8,5
6,5
6,5
1,8
1,8
1,8
1,8
1,3
1,3
1,3
1,1
1,1
0,7
0,7
0,7
0,9
0,9
2,0
2,0
2,0
2,0
2,6
2,6
2,6
2,0
2,0
2,2
2,2
2,5
2,0
2,0
Weight
rpm
Moment of
inertia
J
355
400
450
500
560
630
710
800
900
1000
1120
1250
1400
1500
Efficiency
XA4
XB4
XC4
XD4
XA4
XB4
XC4
XA4
XB4
XA4
XB4
XC4
XA4
XB4
690V
(A)
357
402
452
502
548
617
694
805
902
1007
1114
1242
1377
1475
Power
factor
355
355
355
355
400
400
400
450
450
500
500
500
560
560
400V
(A)
615
696
782
869
950
1069
-----------------
Rated
torque
Tn
(kW)
Rated
speed
Rated
power
AD
Rated
current
In
Motor type
4 Poles – 50HZ - 1500rpm
(Kgm 2 )
(kg)
9,5
10,6
11,5
12,8
17,1
18,5
21,1
36,2
40,3
60,0
68,0
78,0
82,5
91,0
2200
2300
2460
2720
3360
3430
3620
5200
5500
6750
7250
7500
8570
8700
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 5 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
LARGE 3-PHASE AC MOTORS FOR INVERTER DUTY OR GRID CONNECTED
TECHNICAL DATA
3040
3426
3861
4343
4826
5405
6081
6853
7721
8687
9652
10810
12004
13445
0,85
0,85
0,85
0,86
0,86
0,86
0,83
0,83
0,83
0,84
0,84
0,84
0,85
0,85
95,2
95,3
95,3
95,6
95,7
95,7
94,8
95,2
95,5
95,6
95,6
95,7
95,7
96,0
6,5
6,5
6,5
6,8
6,8
6,8
7,0
7,0
7,0
7,0
7,5
7,5
6,5
7,0
1,8
1,8
1,8
1,3
1,3
1,3
1,1
1,1
1,1
0,8
0,8
0,8
0,8
0,8
2,0
2,0
2,0
2,6
2,6
2,6
1,8
1,8
1,8
2,2
2,2
2,2
1,8
1,8
Tstart/Tn
Tmax/Tn
Weight
990
990
990
990
990
990
990
990
990
990
990
990
995
995
Moment of
inertia
J
η (%)
Tmax/Tn
Cosø
Tstart/Tn
Nm
Istart/In
rpm
Istart/In
315
355
400
450
500
560
630
710
800
900
1000
1120
1250
1400
Efficiency
XB6
XC6
XD6
XA6
XB6
XC6
XA6
XB6
XC6
XB6
XC6
XD6
XA6
XB6
690V
(A)
326
367
413
458
508
569
670
752
845
938
1042
1166
1286
1436
Power
factor
355
355
355
400
400
400
450
450
450
500
500
500
560
560
400V
(A)
564
635
716
793
880
986
1160
---------------
Rated
torque
Tn
(kW)
Rated
speed
Rated
power
AD
Rated
current
In
Motor type
6 Poles – 50HZ - 1000rpm
(Kgm 2 )
(kg)
13,5
14,3
15,4
23,5
26,4
28,8
46,4
50,2
56,7
89,0
98,0
105,0
105,0
130,0
2310
2490
2630
3660
3750
3820
4800
5200
5600
6750
7150
7250
8200
8500
Nm
Cosø
η (%)
740
740
740
740
740
740
745
745
740
740
740
740
745
745
745
3228
3615
4067
4584
5165
5811
6413
7182
8135
9168
9684
10330
11543
12826
14365
0,77
0,77
0,77
0,83
0,83
0,83
0,76
0,76
0,81
0,81
0,81
0,81
0,81
0,81
0,81
94,8
95,0
95,0
95,0
95,0
95,2
94,0
94,5
94,5
95,5
95,5
95,6
95,5
95,7
95,7
6,5
6,5
6,5
6,0
6,0
6,0
7,0
7,0
7,0
7,0
7,0
7,0
5,5
5,5
5,5
1,6
1,8
1,8
1,2
1,2
1,2
1,1
1,1
0,8
0,8
0,8
0,8
0,8
0,8
0,8
2,0
2,0
2,0
2,4
2,4
2,4
1,8
1,8
2,2
2,2
2,2
2,2
1,8
1,8
1,8
Weight
rpm
Moment of
inertia
J
250
280
315
355
400
450
500
560
630
710
750
800
900
1000
1120
Efficiency
XB8
XC8
XD8
XA8
XB8
XC8
XA8
XB8
XA8
XB8
XC8
XD8
XA8
XB8
XC8
690V
(A)
287
320
360
377
424
477
586
652
681
768
811
864
974
1079
1209
Power
factor
355
355
355
400
400
400
450
450
500
500
500
500
560
560
560
400V
(A)
496
555
624
652
735
825
1014
1130
---------------
Rated
torque
Tn
(kW)
Rated
speed
Rated
power
AD
Rated
current
In
Motor type
8 Poles – 50HZ - 750rpm
(Kgm 2 )
(kg)
14,3
15,0
15,9
24,2
26,0
29,0
48,5
52,1
88,0
92,0
92,0
105,0
135,0
160,0
160,0
2410
2600
2750
3350
3430
3760
4900
5300
6750
7000
7100
7250
8000
8500
8650
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 6 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
LARGE 3-PHASE AC MOTORS FOR INVERTER DUTY OR GRID CONNECTED
TECHNICAL DATA
2589
2915
3240
3644
4049
3641
4046
4535
5102
5701
6424
7227
8098
9069
10203
11402
12847
14453
0,75
0,75
0,75
0,75
0,75
0,80
0,80
0,80
0,80
0.75
0,75
0,75
0,80
0,80
0,80
0,81
0,81
0,81
94,5
94,5
94,7
94,7
95,0
94,5
95,0
95,0
95,0
93,8
94,2
94,5
95,4
95,4
95,5
96,0
96,2
96,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
6,5
6,5
6,5
7,0
7,0
7,0
5,0
5,0
5,0
1,2
1,2
1,2
1,2
1,2
1,0
1,0
1,0
1,0
0,9
0,9
0,9
1,0
1,0
1,0
0,9
0,9
0,9
1,8
1,8
1,8
1,8
1,8
2,3
2,3
2,3
2,3
1,8
1,8
1,8
2,2
2,2
2,2
1,8
1,8
1,8
Tstart/Tn
Tmax/Tn
Weight
590
590
590
590
590
590
590
590
590
595
595
595
590
590
590
595
595
595
Moment of
inertia
J
η (%)
Tmax/Tn
Cosø
Tstart/Tn
Nm
Istart/In
rpm
Istart/In
160
180
200
225
250
225
250
280
315
355
400
450
500
560
630
710
800
900
Efficiency
XA10
XB10
XC10
XD10
XE10
XA10
XB10
XC10
XD10
XA10
XB10
XC10
XA10
XB10
XC10
XA10
XB10
XC10
690V
(A)
189
213
236
265
294
249
276
308
347
422
474
531
548
614
690
764
859
963
Power
factor
355
355
355
355
355
400
400
400
400
450
450
450
500
500
500
560
560
560
400V
(A)
326
368
408
459
509
430
476
534
601
731
821
920
-------------
Rated
torque
Tn
(kW)
Rated
speed
Rated
power
AD
Rated
current
In
Motor type
10 Poles – 50HZ - 600rpm
(Kgm 2 )
(kg)
13,2
15,6
17,8
19,4
21,3
19,5
25,6
25,6
26,9
42,5
46,2
50,2
98,0
110,0
125,0
136,0
154,1
175,2
2050
2150
2230
2410
2600
3020
3220
3220
3450
5100
5400
5700
6650
6850
7000
6880
7080
7350
Nm
Cosø
η (%)
490
490
490
490
490
495
495
495
490
490
490
495
495
495
2574
3120
3510
3900
4388
4826
5405
6081
6923
7800
8775
9652
10810
12161
0,71
0,71
0,71
0,74
0,74
0,73
0,73
0,73
0,76
0,76
0,76
0,77
0,77
0,77
93,0
93,0
93,0
94,0
94,2
93,6
94,0
94,3
95,1
95,2
95,3
95,0
95,0
95,3
5,0
5,0
5,0
5,5
5,5
6,0
6,0
6,0
6,0
6,0
6,0
6,5
6,5
6,5
1,0
1,0
1,0
1,0
1,0
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
0,8
1,8
1,8
1,8
2,0
2,0
1,8
1,8
1,8
1,8
1,8
1,8
1,8
1,8
1,8
Weight
rpm
Moment of
inertia
J
132
160
180
200
225
250
280
315
355
400
450
500
560
630
Efficiency
XA12
XB12
XC12
XA12
XB12
XA12
XB12
XC12
XA12
XB12
XC12
XA12
XB12
XC12
690V
(A)
167
203
228
241
270
306
341
383
411
463
520
572
641
718
Power
factor
355
355
355
400
400
450
450
450
500
500
500
560
560
560
400V
(A)
290
351
395
417
468
530
591
663
712
801
900
987
1105
1239
Rated
torque
Tn
(kW)
Rated
speed
Rated
power
AD
Rated
current
In
Motor type
12 Poles – 50HZ - 500rpm
(Kgm 2 )
(kg)
13,5
15,8
18,5
24,8
25,6
48,3
53,2
59,4
100,0
112,0
126,0
135,0
152,0
172,0
2145
2210
2410
3220
3450
5400
5800
6200
6500
6750
6950
6900
7100
7500
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 7 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Mounting arrangement IM1001 (B3) – IC411
Frame
size
355
400
450
500
560
Frame
size
355
400
450
500
560
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
4 ÷ 12
4 ÷ 12
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
4 ÷ 12
4 ÷ 12
A
630
630
686/710
686/710
800
800
900
1000
AB
760
760
870
870
980
980
1080
1170
B1
630
630
710
710
900
900
1250
1400
AC
790
790
864
864
1035
1035
1095
1195
B2
710
710
800
800
1000
1000
-----
B3
800
800
900
900
1120
1120
-----
HD
1020
1020
1100
1100
1290
1290
1365
1480
BB
1140
1140
1120
1120
1495
1495
1600
1680
Mounting dimensions (mm)
B4
C
D
E
--254
75
140
--254
95
170
--280
80
170
--280
110
210
1250
280
95
170
1250
280
120
210
--315
140
250
--355
160
300
Overall dimensions (mm)
LD
HA
AA
368
52
135
368
52
135
362
45
160
362
45
160
400
45
225
400
45
225
412
65
180
410
76
210
F
20
25
22
28
25
32
36
40
X
430
430
430
430
560
560
560
560
G
67,5
86
71
100
86
109
128
147
Y
545
545
545
545
615
615
615
615
H
355
355
400
400
450
450
500
560
Z
250
250
246
246
300
300
300
300
K
35
35
35x47
35x47
35
35
42x60
42x52
L
1870
1900
1980
2025
2360
2400
2550
2610
Cable glands : 7 – M63 x 1,5
Mounting arrangement IM1001 (B3) – IC416
When independent axial forced ventilation is required, dimension “L” changes as indicated in the table below:
Frame size
355
400
450
500
560
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
4 ÷ 12
4 ÷ 12
L
2050
2080
2230
2255
2660
2700
2850
2910
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 8 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Mounting arrangement IM2001 (B35) – IC411
Frame
size
355
400
450
500
560
Frame
size
355
400
450
500
560
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
4 ÷ 12
4 ÷ 12
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
4 ÷ 12
4 ÷ 12
A
B1
B2
B3
B4
C
630
630
686/710
686/710
800
800
900
1000
630
630
710
710
900
900
1250
1400
710
710
800
800
1000
1000
-----
800
800
900
900
1120
1120
-----
--------1250
1250
-----
254
254
280
280
280
280
315
355
AB
760
760
870
870
980
980
1080
1170
AC
790
790
864
864
1035
1035
1095
1195
HD
1020
1020
1100
1100
1290
1290
1365
1480
BB
1140
1140
1120
1120
1495
1495
1600
1680
Mounting dimensions (mm)
D
E
F
G
H
75
95
80
110
95
120
140
160
140
170
170
210
170
210
250
300
20
25
22
28
25
32
36
40
67,5
86
71
100
86
109
128
147
Overall dimensions (mm)
LD
HA
AA
368
52
135
368
52
135
362
45
160
362
45
160
400
45
225
400
45
225
412
65
180
410
76
210
355
355
400
400
450
450
500
560
K
M
N
P
S
T
35
35
35x47
35x47
35
35
42x60
42x52
740
740
940
940
1120
1120
1080
1180
680
680
880
880
1180
1180
1000
1120
800
800
1000
1000
1250
1250
1150
1250
8-24
8-24
8-28
8-28
8-28
8-28
8-28
8-28
6
6
6
6
7
7
6
7
X
430
430
430
430
560
560
560
560
Y
545
545
545
545
615
615
615
615
Z
250
250
246
246
300
300
300
300
L
1870
1900
1980
2025
2360
2400
2550
2610
Cable glands : 7 – M63 x 1,5
Mounting arrangement IM2001 (B35) – IC416
When independent axial forced ventilation is required, dimension “L” changes as indicated in the table below:
Frame size
355
400
450
500
560
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
4 ÷ 12
4 ÷ 12
L
2050
2080
2230
2255
2660
2700
2850
2910
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice.
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 9 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Mounting arrangement IM3011 (V1) – IC411
Frame
size
355
400
450
500
560
Poles
4 ÷ 12
4 ÷ 12
4 ÷ 12
4 ÷ 12
4 ÷ 12
D
95
110
120
140
160
E
170
210
210
250
300
F
25
28
32
36
40
Mounting dimensions (mm)
G
M
N
P
86
740
680
800
100
940
880
1000
109
1120
1180
1250
128
1080
1000
1150
147
1180
1120
1250
S
8-24
8-28
8-28
8-28
8-28
T
6
6
6
6
7
AC
790
864
1035
1095
1195
Overall dimensions (mm)
HD
X
Y
Z
1190
430
545
250
1270
430
545
246
1520
560
615
300
1576
560
615
300
1681
560
615
300
L
2290
2125
2600
2700
2960
Cable glands : 7 – M63 x 1,5
Note: protective roof is standard mounted for V1 motors.
Mounting arrangement IM3011 (V1) – IC416
When independent axial forced ventilation is required, dimension “L” changes as indicated in the table below:
Frame size
355
400
450
500
560
Poles
2
4 ÷ 12
2
4 ÷ 12
2
4 ÷ 12
4 ÷ 12
4 ÷ 12
L
2050
2080
2230
2255
2660
2700
2850
2910
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 10 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Motors with independent axial ventilation IC 416
When wide constant torque speed regulation is required, an independent axial fan can be assembled, with
separate supply, to guarantee an efficient motor cooling at low speed.
The assembling of a hollow shaft pulse generator can also be done.
The degree of protection of the whole motor is still IP55.
The fan cover is in steel, the fan blades are as indicated in tables of main constructive figures.
Power
W
650
650
650
1100
1100
Frame
355
400
450
500
560
Auxiliary blowers data – Cast iron body
Current
Speed
Noise level
A max
rpm
dBA
0.91
1500/1800
75
0.91
1500/1800
76
0.91
1500/1800
76
1.9
1050
77
1.9
1050
77
Weight
kg
30
40
48
55
65
Pulse generator
A hollow shaft (15 mm diameter) pulse generator can be assembled to control the motor speed; usually, pulse
generator terminals are loose. SICMEMOTORI can supply the following pulse generators:
Pulses per rev.
1024*
1024*
Electronic
HTL
TTL
Supply
4,5÷32Vdc
4,5÷32Vdc
Signals voltage
11-30Vdc
5Vdc
Type
VFS60
VFS60
*Pulses per revolutions can be programmed in the range 526÷4096ppr
Other pulse generators, with same fixing dimensions, can be assembled by the customer itself.
Pulse generator can not be mounted for motors with second power shaft end.
Maximum speed
When used with an inverter, motors can be asked to work at speed higher than the nominal one.
The following table gives the max mechanical speed for the motors of this catalogue.
Frame
size
AD 355
AD 400
AD 450
AD 500
AD 560
Pole Nr.
Max speed (rpm)
2
4
6
8
2
4-6-8
2
4
6-8
4
6
8
4
6
8
3800
3100
3100
3100
3500
2500
3200
2100
1900
1900
1800
1700
1800
1800
1800
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 11 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Terminal box and cable glands
Terminal box has IP55 degree of protection (provided that supply cable connection is properly made).
The terminal board is normally equipped with 6 terminals, and it is made with non hygroscopic and anti-mold
material.
A second terminal box is provided for accessories.
Tolerances
Operating characteristics are guaranteed with the tolerances defined by IEC 60031-1 Standards, as showed in the
following table.
Characteristics
Efficiency
Power factor
Tolerances
Motor power ≤ 50 kW:
-15% of (1 - η)
Motor power > 50 kW:
-10% of (1 - η)
+1/6 (1- cosϕ)
Min 0.02 Max 0.07
Locked rotor current
+20% of guaranteed value
Locked rotor torque
-15% + 25% of guaranteed value
Pull out torque
-20% of guaranteed value
Slip
Power motor < 1 kW:
± 30% of guaranteed value
Power motor ≥ 1 kW:
± 20% of guaranteed value
Accessories included as standard
All motors of the AD series are standard equipped with:
•
•
•
•
•
3 x Pt100 sensors for temperature control of the stator windings
1 x PTC 150°C on the stator windings
2 x Pt100 sensors for temperature control of the bearings
220V-50Hz single phase AC-heater
Insulated bearing
Heaters
All motors of the AD series are standard equipped with 4 pcs 99Watt 230V 50Hz.
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 12 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Available options and accessories (with overprice)
Option
IC416 kit with encoder provision
YES
Encoder (hollow shaft)
YES
Terminal box right, left, DE view
YES
2nd power shat end
YES
NDE insulated bearing
Standard
1xPTC (150 °C)
Standard
Extra PTC (150°C) as back-up
YES
Extra PTC (130°C) for warning
YES
3xPt100 in windings
Standard
Additional 3xPt100 in winding as back-up
DE roller bearing
YES
YES
2xPt100 in bearings
Standard
Special balancing (R, S degree)
YES
Other supply voltage/frequency
YES
Other mounting arrangements (B35-V1)
YES
Anticondensation heaters
Standard
Special painting for saline environment
YES
Main constructive figures
Casing
Stator
End shields
Flanges
Bearings
Terminal box
Fan blades
Fan cover
Name plate
Stator winding
Rotor
Cage
Shaft
Cooling IC416 *
Insulated NDE bearing
Frame
Material
Material
Feet
Material
Material
DE
NDE
Lubrication
Material
Material
Material
Material
Material
Material
Material
Material
355
400
450
500
560
Cast iron
Lamination
Fixed
Cast iron
Cast iron
Ball or roller bearings
Ball bearings
Grease
Cast iron
Plastic
Aluminium
Steel
Steel
Copper round wire with special insulation for inverter duty
Lamination
Lamination + Copper bars
Die-casted Al
Steel
Steel (on request)
Compulsory for inverter duty motors
* on request (with mounting kit)
Informations given in tables are indicative, certified values are available on request.
SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 13 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Permissible radial loads for horizontal and vertical motors (FR)
The following table gives the permissible radial force in N, assuming zero axial force ** and standard ball bearings.
In case of higher radial force than given in the table an enforced bearing must be used. The values are based on
normal conditions at 50Hz and calculated for 20.000 working hours for 2 pole motors and 40.000 hours for 4, 6 and
8 pole motors. For 60Hz, the values must be reduced by 10%.
Type
Pole
2
4
6
8
2
4
6
8
2
4
6
8
AD 355
AD 400*
AD 450
AD 500
AD 560
Maximum radial force (FR)
N
Xc
X1/2
XMax
mm
16330
15390
8730
28300
25860
14290
32400
29600
16350
35660
32580
18000
33730
38610
42500
31140
35650
39240
19280
22070
24290
Please ask SICMEMOTORI
*Standard motors
** In case FA and FR apply both please contact SICMEMOTORI
The radial loads acting on the shaft is computable using the following formula:
6
Fr= 19.5 x 10 x (Pn) / (D x nn) ± Pp
D
Pn
nn
k
Fr
: diameter of the pulley (mm)
: nominal power of the motor (kW)
: nominal speed or the motor (rpm)
: belt tension factor : 1,25 for toothed belts, 2,35 for trapezoidal belts
: radial load
In case of higher radial force than given in the table an enforced bearing must be used. The values are based on
normal conditions at 50Hz and calculated for 20.000 working hours for 2 pole motors and 40.000 hours for 4, 6 and
8 pole motors. For 60Hz, the values must be reduced by 10%.
Permissible axial loads for horizontal and vertical motors (FA)
The following table gives the permissible axial force in N, assuming zero radial force **. In this case motors must be
ordered with standard bearings. In case of higher axial force than given in the table an angular contact bearing
must be used. The values are based on normal conditions at 50Hz and calculated for 20.000 working hours for 2
pole motors and 40.000 hours for 4, 6 and 8 pole motors. For 60Hz, the values must be reduced by 10%.
Fpressure is calculated fora fixed bearing at the DE.
Type
Pole
B3
FPressure
6100
9800
10500
12500
Maximum axial force (FA)
N
B3
V1
Fpull
FPressure
1850
14000
3900
18300
4700
20700
6000
21500
2
4
6
8
2
4
11200
3900
18500
AD 400
6
12500
4800
19500
8
12800
4950
21500
2
AD 450
4
AD 500
Please ask SICMEMOTORI
6
AD 560
8
*data calculated on 20.000 working hours
** In case FA and FR apply both please contact SICMEMOTORI
AD 355
V1
Fpull
800
2500*
3500*
3600*
1600*
2200*
2900*
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 14 of 16
AD SERIES – 355÷560
Large three-phase ac motors for inverter duty
Motor spare parts list / Sectional drawing
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
DE shield
Bolt
Washer
Washer
Shaft sleeve
Key
DE bearing assembly
Pt100 for DE bearing
DE SPM nipple
Rotor
Stator
NDE bearing assembly
PT100 for NDE bearing
NDE shield
NDE SPM nipple
Plug through-hole
Rotation label
Rivet
Fan cover
Small terminal box
Connection diagram
Bolt
Washer
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
Cover plate
Rubber seal
Fan
Circlip
Key
Bolt
Washer
Washer
Screw
Shaft protector
Nut
Bolt
Washer
Plug
Condense hole plug
Joint part
Terminal box
Connection diagram
Clamp
Bolt
Sticker
Nameplate
Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy
C-AD-355-560-E-11
Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected]
Page 15 of 16
Products listed in this catalogue are exclusively designed and built for industrial purposes.
For particular cases in NON-industrial environments, or where other types of protection must be provided (for
example against contact with children fingers, etc.), these guards or additional protections must be realized by the
Customer.
Any non-observance of the rules for installation, use and maintenance or any modification/tampering with the motor
makes the guarantee rights invalid and exempts SICMEMOTORI from any responsibility
All data and indications shown in this catalogue have to be considered only as a guideline.
Any use of the motor differently from the specifications indicated in this catalogue does not involve any liability for
SICMEMOTORI as manufacturer
SICMEMOTORI reserves the right to modify at any time and without notice the data, the technical
characteristics, the dimensions, the weights and the illustrations.
SICMEMOTORI refuses all responsibility for direct or indirect damages caused by possible errors and/or omissions
in the present catalogue
The reproduction, even in part, of the present catalogue must be authorized in writing by SICME MOTORI srl.
SICME MOTORI srl. All rights reserved
WARNING
The motors and the electrical devices feeding them are electrical components installed on machines and
industrial systems subject to high voltage. During operation, these components can be dangerous since
they are live, they can have non-insulated and rotating parts and they can reach high temperatures.
Therefore, they can be extremely harmful to personnel and objects if the instructions for the installation,
the use and the maintenance are not respected.
The motors are always supplied complete with the installation, use and maintenance instruction manual. It
is necessary to read and understand all the information contained before proceeding to connect and to
start up the installation. If the abovementioned documentation is lacking, please ask a copy to
SICMEMOTORI.