LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AD SERIES FRAMES 355 ÷560 400kW ÷ 1500kW (1500rpm) FOR INVERTER DUTY Code C-AD-355-560-E-11 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Declaration of conformity The motors described in this catalogue satisfy the essential requisites of the following Directives: - 72/23/EEC Low Voltage Directive Reference has also been made to the following directives, specifically for the reasons listed as follows: - EMC 89/336/EEC (Electromagnetic Compatibility) Directive - 2006/42/CE Machinery Directive The electric motors/generators are components that are incorporated into other machines, systems and plants and therefore the resulting EMC behaviour is under the responsibility of the Manufacturer of the machine or plant incorporating the motor/generator. With reference to the 2006/42/EC Directive, it must be specified that the motors/generators must be installed in compliance with the installation instructions and cannot be put into service until the machine in which they are incorporated has been declared in compliance with the 2006/42/EC Machinery Directive. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 2 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty SICMEMOTORI, among the European leaders for variable speed applications, presents this series of large threephase heavy duty asynchronous motors, expressly designed for inverter duty. Designing and manufacturing characteristics, together with materials utilised for the construction of these motors, make this series one of the most advanced actually available on the market Main technical features Frames 355÷560 Squirrel cage rotor Class F insulation Class F temperature rise when inverter supplied Class B temperature rise when grid connected Insulation and impregnation expressly designed for inverter duty Insulated bearing Dimensions according to IEC 60072 Std. Ratings and performances according to IEC 60034-1Std. Degree of protection IP55 (IEC 60034-5 Std.) Type of cooling IC411 and IC416 (IEC 60034-6 Std.) Terminal box (degree of protection IP55) on top Mounting arrangements IM1001 (B3), IM2001 (B35), IM3011(V1) and derivated (IEC 60034-7 Std.) Half-key balancing Metallic name plate Low noise level (IEC 60034-9 Std.) Constant torque speed regulation (with inverter supply) down to 25Hz for IC411 selfventilated motors Constant torque speed regulation (with inverter supply) down to 5Hz for IC416 forced ventilated motors Constant power speed regulation (with inverter supply) up to 75Hz (max. speed must be compatible with table at page 11). Final colour grey RAL7031 All motors are in conformity with European Directives and are CE marked. Motors can run(when grid connected) with voltage variation of ± 10% and frequency variation of ± 5% with a maximum combined variation of ± 10%, with temperature rise in compliance with IEC Standards. Sound pressure Motor type 3000 1500 AD 355 AD 400 AD 450 AD 500 AD 560 94 95 93 ----- 87 88 93 94 97 Synchronous speed (rpm) 1000 750 Sound pressure level (dBA) 80 75 82 78 89 84 90 90 90 89 600 500 70 73 80 88 86 70 73 77 88 80 Bearings Motor type AD 355 AD 400 AD 450 AD 500 AD 560 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 Mounting B3 (IM1001) – B35 (IM2001) Non Drive End Drive End Non Drive End Insulated bearing Ball Roller Ball Ball 6317 C3 --6317 C3 6317 MC3 VL0241 6322 C3 NU322 6322 C3 6322 MC3 VL0241 6317 C3 --6317 C3 6317 MC3 VL0241 6326 C3 NU326 6326 C3 6326 MC3 VL0241 6220 C3 --6220 C3 6320 MC3 VL0241 6328 C3 NU328 6328 C3 6328 MC3 VL0241 --------6330 C3 NU330 6330 C3 6330 MC3 VL0241 --------6334 C3 NU334 6330 C3 6330 MC3 VL0241 Mounting V1 (IM3011) Drive End Non Drive End Ball --6322 C3 --6326 C3 --6328 C3 --6330 C3 --6334 C3 Ball --7322B --7326B --7328B --7330B --7330B Transport locking: all motors with an “NU bearing” or an “Angular contact bearing” are fitted with a transport locking device to prevent damage to the bearings due to vibrations during transport. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 3 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Frequency drive: for all motors driven by a frequency converter an insulated bearing at the NDE side is mounted. For motors in V1 mounting, the insulated bearing Is mounted at the DE side, and the “angular contact bearing” at the NDE side All AD motors are supplied with insulated bearing as standard Inverter duty The AD series AC motors are designed and manufactured expressely for inverter duty, referring to the IEC guidelines (EN60034-25). VPI impregnation assures the maximum performances and together with the insulated materials and the upgraded special double coated copper wire give the best possible behaviour when the motors are supplied by vector-control inverter. It is advisable that max dV/dt at motor terminals is 2kV/µsec (voltage 400V) or 1,5kV/µsec (690V). Ratings and technical data The tables of technical data are referred tocontinuous duty S1, an ambient temperature of 40°C and an altitude up to 1000 m.a.s.l.. In different environmental conditions output ratings vary, and are obtainable by applying the factors showed in table 6, maintaining the temperature rise within the B insulation class (F insulation class when inverter supplied). Altitude m.a.s.l. <= 1000 1500 2000 3000 4000 30 1.06 1.04 1 0.96 0.91 30-40 1 0.97 0.95 0.89 0.84 Ambient temperature (°C) 45 50 0.97 0.94 0.94 0.91 0.92 0.88 0.86 0.82 0.80 0.76 55 0.90 0.87 0.84 0.78 0.72 60 0.87 0.84 0.81 0.74 0.67 Rated Power Rated current Rated speed Rated torque Power factor Efficiency Istart/In Tstart/Tn Moment of inertia Weight : : : : : : : : : : Weight η (%) Moment of inertia J Cosø Tmax/Tn Nm Tstart/Tn rpm Istart/In Efficiency 690V (A) Power factor 400V (A) Rated torque Tn (kW) Rated speed Rated power AD Rated current In Motor type Technical data tables key-words (Kgm 2 ) (kg) Nominal mechanical power to the motor shaft Nominal current Nominal speed Nominal torque at the motor shaft Power factor at full load Efficiency at full load Starting current versus Nominal current Starting torque versus Nominal torque Rotor inertia Motor weight Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 4 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty LARGE 3-PHASE AC MOTORS FOR INVERTER DUTY OR GRID CONNECTED TECHNICAL DATA 1140 1285 1445 1606 1796 2020 2277 2561 2881 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 0,90 95,6 95,6 95,8 95,8 95,5 95,6 95,6 95,6 96,0 7,0 7,0 7,0 7,0 7,5 7,5 7,5 7,5 7,5 1,6 1,6 1,6 1,6 1,2 1,2 1,2 0,8 0,8 2,0 2,0 2,0 2,0 2,6 2,6 2,6 2,0 2,0 Tstart/Tn Tmax/Tn Weight 2975 2975 2975 2975 2980 2980 2980 2985 2985 Moment of inertia J η (%) Tmax/Tn Cosø Tstart/Tn Nm Istart/In rpm Istart/In 355 400 450 500 560 630 710 800 900 Efficiency XA2 XB2 XC2 XD2 XA2 XB2 XC2 XA2 XB2 690V (A) 345 389 437 485 545 613 690 778 872 Power factor 355 355 355 355 400 400 400 450 450 400V (A) 596 674 756 840 944 1061 ------- Rated torque Tn (kW) Rated speed Rated power AD Rated current In Motor type 2 Poles - 50Hz - 3000rpm (Kgm 2 ) (kg) 5,0 5,3 5,9 6,4 8,6 9,6 11,0 28,8 32,5 2100 2180 2340 2520 3200 3490 3660 5000 5200 Nm Cosø η (%) 1485 1485 1485 1485 1490 1490 1490 1490 1490 1490 1490 1490 1490 1490 2284 2574 2896 3217 3591 4040 4553 5130 5772 6413 7182 8016 8978 9619 0,87 0,87 0,87 0,87 0,89 0,89 0,89 0,87 0,87 0,87 0,88 0,88 0,89 0,89 95,7 95,7 95,8 95,8 96,0 96,0 96,2 95,6 96,0 95,5 95,6 95,7 95,6 95,6 7,0 7,0 7,0 7,8 7,0 7,0 7,0 7,5 7,5 7,0 7,5 8,5 6,5 6,5 1,8 1,8 1,8 1,8 1,3 1,3 1,3 1,1 1,1 0,7 0,7 0,7 0,9 0,9 2,0 2,0 2,0 2,0 2,6 2,6 2,6 2,0 2,0 2,2 2,2 2,5 2,0 2,0 Weight rpm Moment of inertia J 355 400 450 500 560 630 710 800 900 1000 1120 1250 1400 1500 Efficiency XA4 XB4 XC4 XD4 XA4 XB4 XC4 XA4 XB4 XA4 XB4 XC4 XA4 XB4 690V (A) 357 402 452 502 548 617 694 805 902 1007 1114 1242 1377 1475 Power factor 355 355 355 355 400 400 400 450 450 500 500 500 560 560 400V (A) 615 696 782 869 950 1069 ----------------- Rated torque Tn (kW) Rated speed Rated power AD Rated current In Motor type 4 Poles – 50HZ - 1500rpm (Kgm 2 ) (kg) 9,5 10,6 11,5 12,8 17,1 18,5 21,1 36,2 40,3 60,0 68,0 78,0 82,5 91,0 2200 2300 2460 2720 3360 3430 3620 5200 5500 6750 7250 7500 8570 8700 Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 5 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty LARGE 3-PHASE AC MOTORS FOR INVERTER DUTY OR GRID CONNECTED TECHNICAL DATA 3040 3426 3861 4343 4826 5405 6081 6853 7721 8687 9652 10810 12004 13445 0,85 0,85 0,85 0,86 0,86 0,86 0,83 0,83 0,83 0,84 0,84 0,84 0,85 0,85 95,2 95,3 95,3 95,6 95,7 95,7 94,8 95,2 95,5 95,6 95,6 95,7 95,7 96,0 6,5 6,5 6,5 6,8 6,8 6,8 7,0 7,0 7,0 7,0 7,5 7,5 6,5 7,0 1,8 1,8 1,8 1,3 1,3 1,3 1,1 1,1 1,1 0,8 0,8 0,8 0,8 0,8 2,0 2,0 2,0 2,6 2,6 2,6 1,8 1,8 1,8 2,2 2,2 2,2 1,8 1,8 Tstart/Tn Tmax/Tn Weight 990 990 990 990 990 990 990 990 990 990 990 990 995 995 Moment of inertia J η (%) Tmax/Tn Cosø Tstart/Tn Nm Istart/In rpm Istart/In 315 355 400 450 500 560 630 710 800 900 1000 1120 1250 1400 Efficiency XB6 XC6 XD6 XA6 XB6 XC6 XA6 XB6 XC6 XB6 XC6 XD6 XA6 XB6 690V (A) 326 367 413 458 508 569 670 752 845 938 1042 1166 1286 1436 Power factor 355 355 355 400 400 400 450 450 450 500 500 500 560 560 400V (A) 564 635 716 793 880 986 1160 --------------- Rated torque Tn (kW) Rated speed Rated power AD Rated current In Motor type 6 Poles – 50HZ - 1000rpm (Kgm 2 ) (kg) 13,5 14,3 15,4 23,5 26,4 28,8 46,4 50,2 56,7 89,0 98,0 105,0 105,0 130,0 2310 2490 2630 3660 3750 3820 4800 5200 5600 6750 7150 7250 8200 8500 Nm Cosø η (%) 740 740 740 740 740 740 745 745 740 740 740 740 745 745 745 3228 3615 4067 4584 5165 5811 6413 7182 8135 9168 9684 10330 11543 12826 14365 0,77 0,77 0,77 0,83 0,83 0,83 0,76 0,76 0,81 0,81 0,81 0,81 0,81 0,81 0,81 94,8 95,0 95,0 95,0 95,0 95,2 94,0 94,5 94,5 95,5 95,5 95,6 95,5 95,7 95,7 6,5 6,5 6,5 6,0 6,0 6,0 7,0 7,0 7,0 7,0 7,0 7,0 5,5 5,5 5,5 1,6 1,8 1,8 1,2 1,2 1,2 1,1 1,1 0,8 0,8 0,8 0,8 0,8 0,8 0,8 2,0 2,0 2,0 2,4 2,4 2,4 1,8 1,8 2,2 2,2 2,2 2,2 1,8 1,8 1,8 Weight rpm Moment of inertia J 250 280 315 355 400 450 500 560 630 710 750 800 900 1000 1120 Efficiency XB8 XC8 XD8 XA8 XB8 XC8 XA8 XB8 XA8 XB8 XC8 XD8 XA8 XB8 XC8 690V (A) 287 320 360 377 424 477 586 652 681 768 811 864 974 1079 1209 Power factor 355 355 355 400 400 400 450 450 500 500 500 500 560 560 560 400V (A) 496 555 624 652 735 825 1014 1130 --------------- Rated torque Tn (kW) Rated speed Rated power AD Rated current In Motor type 8 Poles – 50HZ - 750rpm (Kgm 2 ) (kg) 14,3 15,0 15,9 24,2 26,0 29,0 48,5 52,1 88,0 92,0 92,0 105,0 135,0 160,0 160,0 2410 2600 2750 3350 3430 3760 4900 5300 6750 7000 7100 7250 8000 8500 8650 Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 6 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty LARGE 3-PHASE AC MOTORS FOR INVERTER DUTY OR GRID CONNECTED TECHNICAL DATA 2589 2915 3240 3644 4049 3641 4046 4535 5102 5701 6424 7227 8098 9069 10203 11402 12847 14453 0,75 0,75 0,75 0,75 0,75 0,80 0,80 0,80 0,80 0.75 0,75 0,75 0,80 0,80 0,80 0,81 0,81 0,81 94,5 94,5 94,7 94,7 95,0 94,5 95,0 95,0 95,0 93,8 94,2 94,5 95,4 95,4 95,5 96,0 96,2 96,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 5,5 6,5 6,5 6,5 7,0 7,0 7,0 5,0 5,0 5,0 1,2 1,2 1,2 1,2 1,2 1,0 1,0 1,0 1,0 0,9 0,9 0,9 1,0 1,0 1,0 0,9 0,9 0,9 1,8 1,8 1,8 1,8 1,8 2,3 2,3 2,3 2,3 1,8 1,8 1,8 2,2 2,2 2,2 1,8 1,8 1,8 Tstart/Tn Tmax/Tn Weight 590 590 590 590 590 590 590 590 590 595 595 595 590 590 590 595 595 595 Moment of inertia J η (%) Tmax/Tn Cosø Tstart/Tn Nm Istart/In rpm Istart/In 160 180 200 225 250 225 250 280 315 355 400 450 500 560 630 710 800 900 Efficiency XA10 XB10 XC10 XD10 XE10 XA10 XB10 XC10 XD10 XA10 XB10 XC10 XA10 XB10 XC10 XA10 XB10 XC10 690V (A) 189 213 236 265 294 249 276 308 347 422 474 531 548 614 690 764 859 963 Power factor 355 355 355 355 355 400 400 400 400 450 450 450 500 500 500 560 560 560 400V (A) 326 368 408 459 509 430 476 534 601 731 821 920 ------------- Rated torque Tn (kW) Rated speed Rated power AD Rated current In Motor type 10 Poles – 50HZ - 600rpm (Kgm 2 ) (kg) 13,2 15,6 17,8 19,4 21,3 19,5 25,6 25,6 26,9 42,5 46,2 50,2 98,0 110,0 125,0 136,0 154,1 175,2 2050 2150 2230 2410 2600 3020 3220 3220 3450 5100 5400 5700 6650 6850 7000 6880 7080 7350 Nm Cosø η (%) 490 490 490 490 490 495 495 495 490 490 490 495 495 495 2574 3120 3510 3900 4388 4826 5405 6081 6923 7800 8775 9652 10810 12161 0,71 0,71 0,71 0,74 0,74 0,73 0,73 0,73 0,76 0,76 0,76 0,77 0,77 0,77 93,0 93,0 93,0 94,0 94,2 93,6 94,0 94,3 95,1 95,2 95,3 95,0 95,0 95,3 5,0 5,0 5,0 5,5 5,5 6,0 6,0 6,0 6,0 6,0 6,0 6,5 6,5 6,5 1,0 1,0 1,0 1,0 1,0 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 1,8 1,8 1,8 2,0 2,0 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 1,8 Weight rpm Moment of inertia J 132 160 180 200 225 250 280 315 355 400 450 500 560 630 Efficiency XA12 XB12 XC12 XA12 XB12 XA12 XB12 XC12 XA12 XB12 XC12 XA12 XB12 XC12 690V (A) 167 203 228 241 270 306 341 383 411 463 520 572 641 718 Power factor 355 355 355 400 400 450 450 450 500 500 500 560 560 560 400V (A) 290 351 395 417 468 530 591 663 712 801 900 987 1105 1239 Rated torque Tn (kW) Rated speed Rated power AD Rated current In Motor type 12 Poles – 50HZ - 500rpm (Kgm 2 ) (kg) 13,5 15,8 18,5 24,8 25,6 48,3 53,2 59,4 100,0 112,0 126,0 135,0 152,0 172,0 2145 2210 2410 3220 3450 5400 5800 6200 6500 6750 6950 6900 7100 7500 Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 7 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Mounting arrangement IM1001 (B3) – IC411 Frame size 355 400 450 500 560 Frame size 355 400 450 500 560 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 4 ÷ 12 4 ÷ 12 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 4 ÷ 12 4 ÷ 12 A 630 630 686/710 686/710 800 800 900 1000 AB 760 760 870 870 980 980 1080 1170 B1 630 630 710 710 900 900 1250 1400 AC 790 790 864 864 1035 1035 1095 1195 B2 710 710 800 800 1000 1000 ----- B3 800 800 900 900 1120 1120 ----- HD 1020 1020 1100 1100 1290 1290 1365 1480 BB 1140 1140 1120 1120 1495 1495 1600 1680 Mounting dimensions (mm) B4 C D E --254 75 140 --254 95 170 --280 80 170 --280 110 210 1250 280 95 170 1250 280 120 210 --315 140 250 --355 160 300 Overall dimensions (mm) LD HA AA 368 52 135 368 52 135 362 45 160 362 45 160 400 45 225 400 45 225 412 65 180 410 76 210 F 20 25 22 28 25 32 36 40 X 430 430 430 430 560 560 560 560 G 67,5 86 71 100 86 109 128 147 Y 545 545 545 545 615 615 615 615 H 355 355 400 400 450 450 500 560 Z 250 250 246 246 300 300 300 300 K 35 35 35x47 35x47 35 35 42x60 42x52 L 1870 1900 1980 2025 2360 2400 2550 2610 Cable glands : 7 – M63 x 1,5 Mounting arrangement IM1001 (B3) – IC416 When independent axial forced ventilation is required, dimension “L” changes as indicated in the table below: Frame size 355 400 450 500 560 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 4 ÷ 12 4 ÷ 12 L 2050 2080 2230 2255 2660 2700 2850 2910 Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 8 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Mounting arrangement IM2001 (B35) – IC411 Frame size 355 400 450 500 560 Frame size 355 400 450 500 560 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 4 ÷ 12 4 ÷ 12 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 4 ÷ 12 4 ÷ 12 A B1 B2 B3 B4 C 630 630 686/710 686/710 800 800 900 1000 630 630 710 710 900 900 1250 1400 710 710 800 800 1000 1000 ----- 800 800 900 900 1120 1120 ----- --------1250 1250 ----- 254 254 280 280 280 280 315 355 AB 760 760 870 870 980 980 1080 1170 AC 790 790 864 864 1035 1035 1095 1195 HD 1020 1020 1100 1100 1290 1290 1365 1480 BB 1140 1140 1120 1120 1495 1495 1600 1680 Mounting dimensions (mm) D E F G H 75 95 80 110 95 120 140 160 140 170 170 210 170 210 250 300 20 25 22 28 25 32 36 40 67,5 86 71 100 86 109 128 147 Overall dimensions (mm) LD HA AA 368 52 135 368 52 135 362 45 160 362 45 160 400 45 225 400 45 225 412 65 180 410 76 210 355 355 400 400 450 450 500 560 K M N P S T 35 35 35x47 35x47 35 35 42x60 42x52 740 740 940 940 1120 1120 1080 1180 680 680 880 880 1180 1180 1000 1120 800 800 1000 1000 1250 1250 1150 1250 8-24 8-24 8-28 8-28 8-28 8-28 8-28 8-28 6 6 6 6 7 7 6 7 X 430 430 430 430 560 560 560 560 Y 545 545 545 545 615 615 615 615 Z 250 250 246 246 300 300 300 300 L 1870 1900 1980 2025 2360 2400 2550 2610 Cable glands : 7 – M63 x 1,5 Mounting arrangement IM2001 (B35) – IC416 When independent axial forced ventilation is required, dimension “L” changes as indicated in the table below: Frame size 355 400 450 500 560 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 4 ÷ 12 4 ÷ 12 L 2050 2080 2230 2255 2660 2700 2850 2910 Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice. Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 9 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Mounting arrangement IM3011 (V1) – IC411 Frame size 355 400 450 500 560 Poles 4 ÷ 12 4 ÷ 12 4 ÷ 12 4 ÷ 12 4 ÷ 12 D 95 110 120 140 160 E 170 210 210 250 300 F 25 28 32 36 40 Mounting dimensions (mm) G M N P 86 740 680 800 100 940 880 1000 109 1120 1180 1250 128 1080 1000 1150 147 1180 1120 1250 S 8-24 8-28 8-28 8-28 8-28 T 6 6 6 6 7 AC 790 864 1035 1095 1195 Overall dimensions (mm) HD X Y Z 1190 430 545 250 1270 430 545 246 1520 560 615 300 1576 560 615 300 1681 560 615 300 L 2290 2125 2600 2700 2960 Cable glands : 7 – M63 x 1,5 Note: protective roof is standard mounted for V1 motors. Mounting arrangement IM3011 (V1) – IC416 When independent axial forced ventilation is required, dimension “L” changes as indicated in the table below: Frame size 355 400 450 500 560 Poles 2 4 ÷ 12 2 4 ÷ 12 2 4 ÷ 12 4 ÷ 12 4 ÷ 12 L 2050 2080 2230 2255 2660 2700 2850 2910 Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 10 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Motors with independent axial ventilation IC 416 When wide constant torque speed regulation is required, an independent axial fan can be assembled, with separate supply, to guarantee an efficient motor cooling at low speed. The assembling of a hollow shaft pulse generator can also be done. The degree of protection of the whole motor is still IP55. The fan cover is in steel, the fan blades are as indicated in tables of main constructive figures. Power W 650 650 650 1100 1100 Frame 355 400 450 500 560 Auxiliary blowers data – Cast iron body Current Speed Noise level A max rpm dBA 0.91 1500/1800 75 0.91 1500/1800 76 0.91 1500/1800 76 1.9 1050 77 1.9 1050 77 Weight kg 30 40 48 55 65 Pulse generator A hollow shaft (15 mm diameter) pulse generator can be assembled to control the motor speed; usually, pulse generator terminals are loose. SICMEMOTORI can supply the following pulse generators: Pulses per rev. 1024* 1024* Electronic HTL TTL Supply 4,5÷32Vdc 4,5÷32Vdc Signals voltage 11-30Vdc 5Vdc Type VFS60 VFS60 *Pulses per revolutions can be programmed in the range 526÷4096ppr Other pulse generators, with same fixing dimensions, can be assembled by the customer itself. Pulse generator can not be mounted for motors with second power shaft end. Maximum speed When used with an inverter, motors can be asked to work at speed higher than the nominal one. The following table gives the max mechanical speed for the motors of this catalogue. Frame size AD 355 AD 400 AD 450 AD 500 AD 560 Pole Nr. Max speed (rpm) 2 4 6 8 2 4-6-8 2 4 6-8 4 6 8 4 6 8 3800 3100 3100 3100 3500 2500 3200 2100 1900 1900 1800 1700 1800 1800 1800 Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 11 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Terminal box and cable glands Terminal box has IP55 degree of protection (provided that supply cable connection is properly made). The terminal board is normally equipped with 6 terminals, and it is made with non hygroscopic and anti-mold material. A second terminal box is provided for accessories. Tolerances Operating characteristics are guaranteed with the tolerances defined by IEC 60031-1 Standards, as showed in the following table. Characteristics Efficiency Power factor Tolerances Motor power ≤ 50 kW: -15% of (1 - η) Motor power > 50 kW: -10% of (1 - η) +1/6 (1- cosϕ) Min 0.02 Max 0.07 Locked rotor current +20% of guaranteed value Locked rotor torque -15% + 25% of guaranteed value Pull out torque -20% of guaranteed value Slip Power motor < 1 kW: ± 30% of guaranteed value Power motor ≥ 1 kW: ± 20% of guaranteed value Accessories included as standard All motors of the AD series are standard equipped with: • • • • • 3 x Pt100 sensors for temperature control of the stator windings 1 x PTC 150°C on the stator windings 2 x Pt100 sensors for temperature control of the bearings 220V-50Hz single phase AC-heater Insulated bearing Heaters All motors of the AD series are standard equipped with 4 pcs 99Watt 230V 50Hz. Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 12 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Available options and accessories (with overprice) Option IC416 kit with encoder provision YES Encoder (hollow shaft) YES Terminal box right, left, DE view YES 2nd power shat end YES NDE insulated bearing Standard 1xPTC (150 °C) Standard Extra PTC (150°C) as back-up YES Extra PTC (130°C) for warning YES 3xPt100 in windings Standard Additional 3xPt100 in winding as back-up DE roller bearing YES YES 2xPt100 in bearings Standard Special balancing (R, S degree) YES Other supply voltage/frequency YES Other mounting arrangements (B35-V1) YES Anticondensation heaters Standard Special painting for saline environment YES Main constructive figures Casing Stator End shields Flanges Bearings Terminal box Fan blades Fan cover Name plate Stator winding Rotor Cage Shaft Cooling IC416 * Insulated NDE bearing Frame Material Material Feet Material Material DE NDE Lubrication Material Material Material Material Material Material Material Material 355 400 450 500 560 Cast iron Lamination Fixed Cast iron Cast iron Ball or roller bearings Ball bearings Grease Cast iron Plastic Aluminium Steel Steel Copper round wire with special insulation for inverter duty Lamination Lamination + Copper bars Die-casted Al Steel Steel (on request) Compulsory for inverter duty motors * on request (with mounting kit) Informations given in tables are indicative, certified values are available on request. SICMEMOTORI reserves the right to modify designing, technical features and dimensions without prior notice Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 13 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Permissible radial loads for horizontal and vertical motors (FR) The following table gives the permissible radial force in N, assuming zero axial force ** and standard ball bearings. In case of higher radial force than given in the table an enforced bearing must be used. The values are based on normal conditions at 50Hz and calculated for 20.000 working hours for 2 pole motors and 40.000 hours for 4, 6 and 8 pole motors. For 60Hz, the values must be reduced by 10%. Type Pole 2 4 6 8 2 4 6 8 2 4 6 8 AD 355 AD 400* AD 450 AD 500 AD 560 Maximum radial force (FR) N Xc X1/2 XMax mm 16330 15390 8730 28300 25860 14290 32400 29600 16350 35660 32580 18000 33730 38610 42500 31140 35650 39240 19280 22070 24290 Please ask SICMEMOTORI *Standard motors ** In case FA and FR apply both please contact SICMEMOTORI The radial loads acting on the shaft is computable using the following formula: 6 Fr= 19.5 x 10 x (Pn) / (D x nn) ± Pp D Pn nn k Fr : diameter of the pulley (mm) : nominal power of the motor (kW) : nominal speed or the motor (rpm) : belt tension factor : 1,25 for toothed belts, 2,35 for trapezoidal belts : radial load In case of higher radial force than given in the table an enforced bearing must be used. The values are based on normal conditions at 50Hz and calculated for 20.000 working hours for 2 pole motors and 40.000 hours for 4, 6 and 8 pole motors. For 60Hz, the values must be reduced by 10%. Permissible axial loads for horizontal and vertical motors (FA) The following table gives the permissible axial force in N, assuming zero radial force **. In this case motors must be ordered with standard bearings. In case of higher axial force than given in the table an angular contact bearing must be used. The values are based on normal conditions at 50Hz and calculated for 20.000 working hours for 2 pole motors and 40.000 hours for 4, 6 and 8 pole motors. For 60Hz, the values must be reduced by 10%. Fpressure is calculated fora fixed bearing at the DE. Type Pole B3 FPressure 6100 9800 10500 12500 Maximum axial force (FA) N B3 V1 Fpull FPressure 1850 14000 3900 18300 4700 20700 6000 21500 2 4 6 8 2 4 11200 3900 18500 AD 400 6 12500 4800 19500 8 12800 4950 21500 2 AD 450 4 AD 500 Please ask SICMEMOTORI 6 AD 560 8 *data calculated on 20.000 working hours ** In case FA and FR apply both please contact SICMEMOTORI AD 355 V1 Fpull 800 2500* 3500* 3600* 1600* 2200* 2900* Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 14 of 16 AD SERIES – 355÷560 Large three-phase ac motors for inverter duty Motor spare parts list / Sectional drawing 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 DE shield Bolt Washer Washer Shaft sleeve Key DE bearing assembly Pt100 for DE bearing DE SPM nipple Rotor Stator NDE bearing assembly PT100 for NDE bearing NDE shield NDE SPM nipple Plug through-hole Rotation label Rivet Fan cover Small terminal box Connection diagram Bolt Washer 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Cover plate Rubber seal Fan Circlip Key Bolt Washer Washer Screw Shaft protector Nut Bolt Washer Plug Condense hole plug Joint part Terminal box Connection diagram Clamp Bolt Sticker Nameplate Sicme Motori – Strada del Francese 130 – 10156 Torino – Italy C-AD-355-560-E-11 Tel. +39-011-4076311 – Fax +39-011-4500047 – www.sicmemotori.com - [email protected] Page 15 of 16 Products listed in this catalogue are exclusively designed and built for industrial purposes. For particular cases in NON-industrial environments, or where other types of protection must be provided (for example against contact with children fingers, etc.), these guards or additional protections must be realized by the Customer. Any non-observance of the rules for installation, use and maintenance or any modification/tampering with the motor makes the guarantee rights invalid and exempts SICMEMOTORI from any responsibility All data and indications shown in this catalogue have to be considered only as a guideline. Any use of the motor differently from the specifications indicated in this catalogue does not involve any liability for SICMEMOTORI as manufacturer SICMEMOTORI reserves the right to modify at any time and without notice the data, the technical characteristics, the dimensions, the weights and the illustrations. SICMEMOTORI refuses all responsibility for direct or indirect damages caused by possible errors and/or omissions in the present catalogue The reproduction, even in part, of the present catalogue must be authorized in writing by SICME MOTORI srl. SICME MOTORI srl. All rights reserved WARNING The motors and the electrical devices feeding them are electrical components installed on machines and industrial systems subject to high voltage. During operation, these components can be dangerous since they are live, they can have non-insulated and rotating parts and they can reach high temperatures. Therefore, they can be extremely harmful to personnel and objects if the instructions for the installation, the use and the maintenance are not respected. The motors are always supplied complete with the installation, use and maintenance instruction manual. It is necessary to read and understand all the information contained before proceeding to connect and to start up the installation. If the abovementioned documentation is lacking, please ask a copy to SICMEMOTORI.
© Copyright 2024 ExpyDoc