Datasheet | Omniksol 3.0k/4.0k/5.0k TL Omnik New Energy Solar inverter Omniksol 3.0k/4.0k/5.0k TL Features » Transformerless design, high efficiency (Max.97.6%,Euro. 97.0%) » Multi MPPT channels » High MPP tracking accuracy(>99.9%) » Wide DC input range(120-590 Vdc), compatible with different module technologies » Easy wiring, installating and operating » IP 65 design, suitable for indoor and outdoor installation » 5 years warranty(10~25 years as option) » SolarNRG supplies all models with Wifi Kit and integrated DC Switch +LLOIOKTI_)[X\K LUX5STOQYURQ:2 100% 98% 96% [%] 94% 92% 90% 88% 86% 84% 82% 330V 400V 450V 80% 0 5% 10% 20% 30% 50% UL6GI E NE L G uide R D1663 SolarNRG Mercuriusplein 40, 2685 LP Poeldijk, tel: 0174 - 444 171 e-mail: [email protected]. Kijk voor meer informatie op: www.solarnrg.nl 75% 100% Technical Data | Omniksol 3.0k/4.0k/5.0k TL Ty pe Omniksol-3.0k-TL Omniksol-4.0k-TL Omniksol-5.0k-TL In pu t ( D C ) Max. PV-Generator Power AWC Max. DC voltage AVC MPPT DC voltage Range AVC Turn off DC voltage AVC Max. DC Current AAC Nominal DC Current AAC 3400 4500 590 150 - 500 120 36 33 2 MC4 2 36 28 Number of DC Connection DC-Connection Number of MPP Trackers Turn on Power AWC 5000 36 33 10 O u tpu t ( A C ) Max. AC Power AVC Nominal AC Power AWC Max. AC Current AAC Nominal AC Current AAC Grid voltage Range Grid Frequency Range Power Factor THD(AC Output Current ) AC Connector P o we r C o n s u m ptio n Own Consumption in Operation AWC Power Consumption at Night AWC Power Consumption at Standby AWC 3300 4400 4800 3000 4000 4600 14.4 19.0 21.0 13 17.4 20 According to VDE 0126-1-1, RD1663,ENEL2010,C10/11,G83/1, AS4777 According to VDE 0126-1-1, RD1663, ENEL2010,C10/11,G83/1, AS4777 0.99 (>30% of Full Load) Plug-in connector 45 50 0 6 97.5% 96.6% 97.6% 97.0% 99.9% 50 E ffic ie n c y Max. Efficiency (at 360VDC) Euro. Efficiency (at 360VDC) MPPT Efficiency 97.6% 97.0% S a fe ty a n d P r o te c tio n Internal Overvoltage Protection DC Insulation Monitoring Earth Fault Protection Grid Monitoring Earth Fault Current Monitoring DC Current Monitoring Islanding Protection N o r m a tiv e R e fe r e n c e CE- Compliant According to Yes Yes Yes According to VDE 0126-1-1, RD1663, ENEL2010,C10/11,G83/1,AS4777 According to VDE 0126-1-1, RD1663, ENEL2010,C10/11,G83/1,AS4777 According to VDE 0126-1-1, RD1663, ENEL2010,C10/11,G83/1,AS4777 According to VDE 0126-1-1, RD1663, G83/1, AS4777 EN 62109, EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4 EN61000-3-2, EN61000-3-3, EN61000-3-12, EN61000-3-11 D im e n s io n s a n d W e ig h t Dimensions (WxHxD)>PP@ Weight >NJ@ 367x526x163 21 20 E n v ir o n m e n ta l L im its IP Protection Type Operating Temperature Range Relative Humidity Maximum Altitude (above sea level)>P@ Noise Level>G%$@ IP 65 according to IEC 60529 r&WRr& 0% to 98%, no condensation 2000 G e n e r a l D a ta Isolation Type Cooling Concept Housing Mounting Information Display Data Logger Data Communication Interfaces Computer Communication Standard Warranty Transformerless Natural Convection Iron housing for inside and outside installation Wall bracket 3 LED,Backlight, 16 x 2 Character LCD RS485, Optional (Wi-Fi, GPRS, Ethernet) RS232 as Option 5 Years (Optional 10~25 years) SolarNRG Mercuriusplein 40, 2685 LP Poeldijk, tel: 0174 - 444 171 e-mail: [email protected]. Kijk voor meer informatie op: www.solarnrg.nl 21
© Copyright 2024 ExpyDoc