Nature 466 , 647Ğ651 (29 July 2010)
Alexandros Pertsinidis, Yunxiang Zhang & Steven Chu
Miysaka Lab.
Keisuke Yamada
Contents
I. Introduction
II. Experiment
Sample & Setup
III. Results & Discussion
The separation between differently coloured fluorescent molecules
IV. Coclusion
Optical detection
Optical microscope
A type of microscope which uses visible light
and a system of lenses to magnify images of small samples
・ Advantage
nondestructive,
noncontact
observe inside of a sample
・ Disadvantage
diffraction-limited optics (回折限界)
limiting the resolution of the microscopy
(~200 nm)
 : resolution
0.61 

NA
NA : numerical aperture
λ : Wavelength
QuickTimeý Dz
TIFFÅiîÒà•
èkÅ j êLí£Év ÉçÉOÉâÉÄ
ǙDZÇÃÉsÉN É`ÉÉÇ ¾å©ÇÈǞǽDžÇÕïKóvÇ ­Ç•
ÅB
Super-Resolving Microscopy
The resolution power is higer than the optical microscope (≦100 nm)
Example of the method
・ STimulated Emission Depletion (STED) Microscopy
・ Scanning Near Field Optical Microscopy (SNOM)
・ Photoactivated Localization Microscopy (PALM)
・ STochastic Optical Reconstruction Microscopy(STORM)
・ To identify the structure of a biological molecule
・ Nanoscale property in materials can be evaluated.
STED
DM
DM
detector
Excitation laser
STED laser
+
=
Excitation spot
STED spot
The diameter fluorescence spot is decreased
and get better resolution power
SNOM
~100 nm
SNOM is a kind of Scanning Probe Microscope
using optical fiber as probe.
PALM/STORM
生物物理50(4),174-179 藤田克昌
Super-resolution with wide-field microscope
Motivation
To know about the structure of multisubunit biological complexes
in biologically relevant environment
The spatial resolution is limited
by noise and systematic effects that include drift and vibration of
the measurement apparatus
To improve the spatial resolution
utilizing closed-loop feedback system
Sample
PEG
silan
glass
silan
glass
glass
silanize
100 m
BSA
coated glass
biotin
PEG
silan
glass
coated with PEG
coated with biotin
Streptavidin biotin-PEG beads
DNA
Setup
Closed-Loop feedback
system
Result
320 nm
3.2 nm
The feedback systems controll the position
・ By locking the pinhole position in each image, they avoid the effect of the apparatus’ drift
・ By locking a Cy3 molecule and kept same the position, they demonstrate 0.7 nm
molecule to molecule reproducibitliy
Sample
Polystyrene bead
measurement
Locked by feedback system
Laser Optical Tweezers
Measuring the position of the Alexa 647
and using the mapping calibration
a
Result
c
b
0.77 nm spatial resolution
is achieved
Conclusion
・ The Closed-roop feedback system could avoid vibration of the
measurement apparatus and the combined effects of the relay imaging
optics and CCD array.
・ The spatial resolution of 0.77 nm is attained for the optical microscope.
・ The closed-loop control and registration could become
essential concepts in design of future sub-10-nm optical lithography tools