第57回年日本物理学会年次大会 2002年 3月27日 立命館大学 びわこ・くさつキャンパス 1. HERMES Experiment 2. Gain Monitoring System (GMS) Hardware Components 3. Gain Evaluation 4. Summary Contents 東京工業大学 基礎物理学専攻 柴田研究室 他 HERMES Collaborations 田中 秀和, 大須賀 弘, 宮地義之, 柴田利明, HERMES実験のための レーザーに基づく ゲインモニタリングシステム The HERMES Experiment DESY, Hamburg, Germany HERMES Detectors HERMES HERA Storage Ring The aim : Investigation of the nucleon spin structure with deep inelastic scattering (DIS) using - Polarized electron (positron) beam (27.5 GeV) - Polarized internal gas target (H, D, 3He) The Gain Monitoring System PMTs of the detectors monitored by GMS ・ Calorimeter …………………… 840 ・ Hodoscopes …………………… 88 ・ Luminosity Monitor ……… 24 The gain and its linearity for those PMTs can be monitored during data taking. Overview of GMS Components 1. Generate light pulses of 6 type intensities N2 Laser Light filtering system Reference detectors 2. Distribute the light pulses Detectors monitored by GMS Light Filtering System Light filtering system consists of motor, filter wheel and 5 attenuation filters. Motorized Filter Wheel motor The Laser trigger is synchronized with HERA beam bunches and filter wheel. Detector Gain and Linearity ADC histogram of a detector. ADC histogram of reference detector Detector gain ≡slope Detector To evaluate the detector gain, GMS defines the relative gain using reference detector. ADC value pedestal Reference detector ADC value Online Monitoring The Pink Window G (t ) : Evaluated Gain G(ti ) Normalized Gain G(t t0 ) The evaluated and normalized gain of the detectors is visualized on the GMS Pink Window. (updated per minute) Summary ・ HERMES experiment investigates the nucleon spin structure with DIS. ・ HERMES GMS monitors the gain and its linearity for 956 PMTs. ・ The gain evaluated by GMS is used for - data quality parameter (for physics data) - calorimeter correction factor Contents 1. HERMES Experiment 2. Gain Monitoring System (GMS) Hardware Components 3. Gain Evaluation 4. Summary Gain Linearity PMT is saturated. Non-linear response Reference Detector Detector ADC value pedestal Reference detector ADC value ADC histogram of reference detector, accumulated in a run. Typical correlation betw detector and reference de for event by event. Reference Detector pedestal Detector ADC value Histogram of reference detector ADC value, accumulated in a run. Reference detector ADC value Typical scatter plot of detector ADC value vs reference detector for event by event. Detector Response ADC histogram of the detector. The 6 peaks generated by the light filtering system TRD Calorimeter Preshower counter Electron-hadron separation : Preshower counter, Calorimeter, TRD Efficiency in the electron identification : > 97 % Contamination of hadrons to electrons : < 1 % Generation of Light Pulses The Laser trigger is synchronized with HERA beam bunch and filter wheel. Therefore GMS does not interfere the physics data taking. The Laser fires at about 3 Hz. (1) (2) (3) Nitrogen Laser Dye Light filtering system Wave length 337.1 nm 500 nm Energy/Pulse 250 μJ ≦ 100 μJ Pulse width : 5 sn The HERMES DESY, Hamburg, Germany HERMES HERA Storage Ring Attenuation Filter Table : Filter attenuation Filter Number 0 1 2 3 4 5 6 7 Attenuation (%) 50.1 20 No Attenuation No Attenuation 39.8 No Attenuation 31.62 10 The Gain Monitoring System 1. GMS sends the light of 6 different intensities to the PMT of the detectors. during data taking. 2. The lights are also sent to reference detectors. 3. Compare the responses of the PMTs to the light with reference detector. The light of 6 different intensities are used to check the gain linearity. Reference Detector Reference detector is a silicon PIN photo-diode. The reference detector is named “PIN”. Relative Gain Definition Gaindet N GMS i N GMS i ( ADCidet ) corr ( ADCiPIN )corr The relative gain is evaluated every “run” for offline monitoring. ( ADCidet ) corr : pedestal subtracted detector ADC value ( ADCiPIN ) corr : pedestal subtracted PIN ADC value This Gaindet corresponds to the slope of the detector ADC vs PIN ADC. Detector Gain Evaluation (run, fill level) The year 2000 data (run2300-30530) Luminosity monitor Calorimeter Detector Gain Evaluation (run, fill level) fill Preshower counter The detector gain fluctuates less than 4%, in a fill. (fill : beam injection to beam dump, ~8 hours) Detector Gain Evaluation (7 months) Gain change for about 7 months (all year 2000 data). A part of detectors gain decreases about 2% Summary and Outlook - The gain of some detectors decrease about 2% for 7 months. ・ To evaluate the non-linear response of the detector, it is necessary that a few optical filters are added to light filtering system. Laser Monitoring Small PMT The Laser intensity fluctuates about 5%. HERMES Physics Motivation DIS e (Deep Inelastic Scattering) e Target fragments Current fragments < sz > = 1/2 = 1/2 (Δu+Δd+Δs ) +ΔG+Lq+LG ΔΣ Quark spin contribution to the nucleon spin (ΔΣ ) is found to be small in polarized DIS experiments. ΔΣ ~ 0.2 ~ 0.3 Relative Gain Definition det X Gain N GMS i N GMS i ( ADCidet X ) NGMS Ped det X ( ADCidet PIN ) NGMS Ped det PIN ADCidet X : Detector ADC value ADCidetPIN : PIN ADC value Ped det X , PIN : Averaged Pedestal ADC value N GMS : Number of GMS events det X Gain This corresponds to the slope of the detector ADC vs PIN ADC. Gain Definition 2 Ped det X , PIN j N ped 1 X , PIN ADCdet j N ped Ped det X , PIN : Averaged pedestal value ADCidet X ADCidetPIN : detector X, and PIN pedestal value N ped : Number of pedestal events Calorimeter Specification Attenuation of lead glass Quantum efficiency of PMT Table 1 : Laser specification Product Name Spectral Output (nm) Pulse Width (ns) Energy/Pulse (μJ ) LN300C 337.1 5 250 Table 2 : Dye specification Product Name Wave Length (nm) Output Energy (μJ ) Coumarin 500 (7A500) Peak 500 Range 473 ~ 547 ≦ 100 Light Distribution System Main splitter Sub-splitter Table : PIN Photo-diode specification Type S119 Operating Tenparature (℃) -40~+100 Photo Sensitive Surface Size Effective Area Range Peak Wave (mm) (mm2) (nm) Length(nm) 1.1×1.1 1.2 320-1100 960 GMS Fiber Network E.T (Electronics Trailer) Light source D.A (Detector Area) Calo TOP Calo BOTTOM Main splitter Sub-splitter Detector Saturation Laser Trigger Total number of bunches : 220 bunch PIN Sensitivity (1) The light intensity (measured with Laser monitoring system) (2) PIN ADC value (for the no attenuation light) (3) = (2)/(1) PIN Sensitivity 2 Light Intensity PIN Response PIN Response/Light Intensity Average (ADC) 4253 461 0.1 1σ 222 30.4 0.001 Relative Error (%) 5.22 6.59 8.01 PIN reflects the light intensity fluctuation with 8%. Gain Definition Rdet Gdet N photon Rref Gref N photon Gdet Rdet Gref ( ) Rref Gdet Rdet Gref ( ) Rref Rdet : Response of detector Rref : Response of PIN Gdet : Gain of detector Gref : Gain of PIN : Number of photons N photon Detector Saturation Light Source Nitrogen/dye Laser Light filtering system HERMES Time Scale GMS Event Rate GMS event rate depends on the motor rotating speed. The below figure shows motor voltage dependence GMS event rate. The Polarized beam at HERA • Self-polarization by emission of synchrotron radiation • Average beam polarization <pb> ~ 55 % Detector Gain Evaluation (1) (2) (3) Gain change for about 7 months (all year 2000 data). (1) + (2) + (3) A part of detectors gain decreases about 2% Generation of Light Pulses process (1) process (2) process (3) Nitrogen Laser Dye Light filtering system Laser Monitoring System GMS components in E.T PIN Linearity The Gain Gap Polarized target • 40 cm long open-ended storage cell • Undiluted internal targets : – H,D,3He longitudinally polarized atoms • Laser driven polarized 3He (1995) : – PT=46 %, =1015 N/cm2, Δtflip ~ 10 min 質問集1 Q1.GMSが6つの強度の光を選んだ理由 A1. 必ずしも6つである必要はないが、PMTの linearity を評価するのには異なる強度の光を PMT に送る必要がある。 Q2.波長を500nmにする理由(GMSが送っている光の波長に ついて) A2. 窒素レーザーのdefault 出力は337.1nm で、Dyeを用いることで波長を変換している (500nm)。 Q3.GMSのevent rate A3. GMSのevent rateはモーターの回転周波数 に依存している。通常は約3Hzていどに設定され ている。 Q4. reference detector と detector でのGMS event の同期のさせ方 A4. 光ファイバーの長さおよびsignal delayを用 いて調整し、同期できるように設計してある。 Q5.10% attenuation filter の光を840個(calo)に分けても ちゃんとPMTは反応するのか A5. Calo のレスポンスをみるとちゃんと6つの ピークが見えているので問題ない。 Q6.なぜGMSの定義するgainの評価の方法でPMTの増幅率 が分かるのか A6. 厳密には検出器のゲインは分からないが、 reference detectorにたいしての相対的なゲイン については評価することができる。 Q7.どのようにGMS event かどうか判別するのか A7. GMS event は GMS trigger を 用いて識別されている。 Q8.Laser の出力は なぜ 変動するのか A8. ???? Q9.Laser の出力についてはもにたーしているの か A9. Laser の出力をモニターするシス テムがある。 Q10.各検出器にはどれだけのphotonが送られて いるのか。 A10. Laserの出力時には約100μJ であるとすれば、この時点では10^20 個程度のphotonが作られている。 Q11.ADCのHistogramで、それぞれのピークが 広がっているのはなぜか A11. 主な原因はLaserの出力の変動 およびファイバーなどのGMSの hardwareに起因したものによる。 Q12.鉛ガラス、PMTの劣化などをモニターするこ とは可能か。 A12. Calo については、HERAのビー ムによるradiation damage が考えら れるが、これについては、それのモニ ターを目的としたreference detector がinstall されている。 質問集2 Q16.Gainの不確定性さはどれくらいか Q13. 検出器のGMSに対する requirement は何か。 A16. 直線フィットした場合のゲインの不確 また、GMSはそれに対してどれだけその要求を満たし 定さは2%以下。 ているのか。 Q17.本当にgainの定義は(scatter plotの傾き)は A14. caloのエネルギーレゾリュウションが 検出器のゲインを反映しているのか。 最高で約5%程度である。その一方で、GM A17. あくまでGMSが評価できるのは相対 Sのcaloに対するゲインの不確定性は2% ゲインである。が、それを用いることで検出 以下であることから十分にcaloのE-resolution 器のゲインの変動をモニターすることができ よりも良くゲインのモニターを出来ている。 る。 また、CaloはADC値からその粒子のエネル ギーを算出する際、(ほぼ線形な)4次の関数 を使っている。この4次曲線をGMSがちゃんと みることが出来ているかは現在検討中。 Q14.GMSはいつdetectorに光を送っているのか (Laser trigger) A13. HERAのビームバンチの中の positronがfillされていないところが HERMES検出器の場所にきたときに 光を出すように設計されている。 Q15.PINのGainの安定性はどうなっているのか A15. Reference detector同士で それぞれの相対ゲインを評価しているため PINのゲインが変化した場合にはそれを 加味しなければならない。 GMS Performance To evaluate the detector gain, the PIN has to satisfy following points : 1. The PIN is sensitive to the Laser output changes 2. The gain of the PIN is stable
© Copyright 2026 ExpyDoc