Available Interfaces to B-CON integration know-how integration without operating expense directlink to automation device via Ethernet connection via open standard system serial device driver other server OPC name manufacturer supported systems State: April 2015 ICONAG ICONAGSystempartner open bussystems / open standards BACnet CAN-OPEN KNX/EIB Interbus LON M-Bus Mod-Bus/ModBus+ autonomous autonomous autonomous Phoenix u.a. autonomous autonomous autonomous Profibus R6911 Profinet Frako Energiebus autonomous Siemens u.a. autonomous FRAKO Ethernet several Twisted Pair Ethernet, RS485 FTT10, EN 1434 RTU, ASCII DP, FMS, Industrial Ethernet, ISO-TCP/IP autonomous Profinet CBA X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X automation systems / subsection: electricity Beckhoff TWIN-CAD Ethernet I/O Gossen Metrawatt Janitza LCN Merlin Gerin Moeller SuCOnet SAIA S-Bus TWIN-CAD Schneider Electric Siemens S5 Siemens S7 Beckhoff Wiesemann und Theis Gossen Janitza Issendorf Schneider Electric Moeller SAIA Merlin Gerin, Telemecanique, Modicon Siemens u.a. Siemens u.a. Telemecanique Schneider Electric Wago Wago X BACnet X X X X X X X X X Mod-Bus RTU, ASCII S5 S7 X X ModBus Profibus Profibus X X X X X X X X Mod-Bus RTU, ASCII X ModBus X X X LON, KNX, ModBus TCP, ModBus RTU, BACnet X X X X X A2000 UMG metering LCN Mod-Bus RTU, ASCII PS4, SuCOM A S-Bus, PCD 1 bis 4 WAGO-I/O-SYSTEM ModBus X ModBus X X X X X X DDC-systems / subsection: measurement and control ABB Andover ABB Andover Controls Daikin Klimatechnik Danfoss Kältetechnik Elesta RCO Honeywell Excel JCI Metasys JCI-Erweiterungsbus Daikin Danfoss Elesta Honeywell Johnson Controls Johnson Controls Kieback & Peter Landis & Staefa Linde Kältetechnik SAIA S-Bus Samsomatic Sauter TAC Vista Kieback & Peter Siemens Linde SAIA Samson Sauter Cumulus TAC Trend Caradon Trend Wago ICONAG-Leittechnik GmbH Wago X X LON VRV-/SkyAir-/ Split-Inverter RCO, REN Excel 500, Excel 5000 JCI N1-Bus DX90xx, TC, Xt DDC 3000, MRP, LRP, HRP Desigo Insight, Simatic VS2000 S-Bus, PCD 1 bis 4 X X X X X X X X X X X BACnet BACnet, LON X Pro Open Vista X X X X all systems X WAGO-I/O-SYSTEM LON X LON X BACnet LON BACnet LON X Interfaces LON, BACnet LON, BACnet X X LON X LON, KNX, ModBus TCP, ModBus RTU, BACnet X X X X X X X X X X X X X X X X X X X X X 1 of 3 integration know-how integration without operating expense directlink to automation device via Ethernet connection via open standard system serial device driver OPC other server State: April 2015 supported systems name manufacturer Available Interfaces to B-CON ICONAG ICONAGSystempartner security (abstract) American Dynamics DBM ESMI OY Notifier Novar Honeywell American Dynamics DB Lexel AS Notifier Novar Honeywell video-cross bar Bitbus (BMA) ESMI-Bus (BMA) BMA Winmag (BMA/EMA) Winmag (BMA/EMA) X X X X X X X X X X X X X X X media and communication technology AMX DMX gesamte Medientechnik Multitone Pagersysteme Protel AMX DMX Ozzelot Multitone autonomous autonomous AMX-Bus DMX-Bus infrarot (remote control) ESPA 4.4.4 X X X X X X X X X X X X X X automation systems (abstract) ABB ADACS ADAM Allen Bradley Analog Devices Andover Aromat Bailey Bentley Bosch Rexroth Bristol Babcock CAL Controls Citect Contrex Controlnet Cutler-Hammer DataLink DDE DeviceNET Endress & Hauser Ethway Ethernet I/O ETM Eurotherm FieldBUS Fieldpoint Fisher & Porter Fisher-Rosemount Fuji Electric ICONAG-Leittechnik GmbH ABB ADACS ADAM Allen Bradley Analog Devices Andover Aromat Bailey Bentley Bosch Rexroth Bristol Babcock CAL Controls Citect Contrex Controlnet Kepware DataLink DDE DeviceNET Endress & Hauser Ethway Wiesemann und Theis ETM Eurotherm FieldBUS National Instruments Fisher & Porter ProcessX Fuji Electric AC 800M/C ADACS ADAM Allen Bradley Analog Devices Andover Aromat Bailey Bentley Bosch Rexroth Bristol Babcock CAL Controls Citect M Series, CX 1000 Controlnet D50/D300 DataLink DDE DeviceNET Endress & Hauser Ethway Ethernet I/O ETM Eurotherm 800 FieldBUS Fieldpoint Fisher & Porter Fisher-Rosemount Fuji Electric X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Interfaces X X X X X X X X X X X 2 of 3 integration know-how integration without operating expense directlink to automation device via Ethernet connection via open standard system serial device driver other server OPC State: April 2015 supported systems manufacturer name Available Interfaces to B-CON ICONAG X ICONAGSystempartner GE Fanuc GE GE Fanuc 90 CCM/SNPX X Genesis OPC Genesis Genesis X Hilscher CIF Hilscher Hilscher X HIMA Paul Hildebrandt HIMA Paul Hildebrandt HIMA Paul Hildebrandt X ICONICS ICONICS ICONICS X X Idec Idec Idec X INOSOFT INOSOFT INOSOFT X Intellution Intellution Fix X X Intouch Invensys Intouch X X Kessler-Ellis Products Kepware Universal Protocol Koyo Koyo Koyo X Lecom Lecom Lecom X Matsushita Matsushita Matsushita X X Mitsubishi Mitsubishi A/FX X X Modicon/AEG Schneider Electric Mod-Bus RTU, ASCII X ModBus X National Instruments National Instruments Fieldpoint X X OMRON OMRON OMRON X X OPTO Eldridge OPTO 22 X X PPI/PPI+ Applicom PPI/PPI+ X Rockwell Rockwell RS Linx X X Square D Schneider Electric ModBus X X Sysmac-way Applicom Sysmac-way X Telelift Swisslog Telelift X X Texas Instruments Texas Instruments Process X X X Toshiba Toshiba G3 X Triconex ProcessX Triconex X Voith Paper Automation Voith Paper Automation X West ProcessX West Series 3010 X WinCC Siemens WinCC X X Wonderware Invensys Intouch X X Yokogawa Yokogawa Centum/Darwin/Green X Notice: Furthermore, B-CON supports the possibility to integrate simple communication interfaces directly by using the serial interface (RS232/485). The serial system either can be connected to the B-CON server directly or by using an Ethernet adapter used in a TCP/IP network. ICONAG-Leittechnik GmbH Interfaces X 3 of 3
© Copyright 2024 ExpyDoc