Force Measuring and Weighing Technology Force Transducer KAM Special Features 500N to 200kN Small dimensions Made of stainless steel Hermetically sealed (IP 67) Option: integrated amplifier Dimensions Wiring code H Cable length 1,5 m (+EX) brown black green I yellow white (+EX) brown black green white yellow With integrated amplifier Rated load A B C D F G H I Weight KAM 0,5 kN – 10kN ∅11-0,1 R50 25 M4 ∅30 ∅40 4 10 0,25kg KAM 20kN/50 kN ∅24-0,1 R100 48 M10 ∅70 ∅90 12,5 12 1,80kg KAM 100 kN/200kN ∅32-0,1 R160 60 M12 ∅90 ∅115 12,5 12 3,20kg Specifications Accuracy class 0,5 Rated load (=FN) KN Safe overload Ultimate overload Safe side load Reference temperature Compensated temperature range Storage temperature range Environmental protection (EN 60529) %FN %FN %FN °C °C °C Sensitivity (=S) Zero balance Max. excitation voltage Input resistance Output resistance Insulation resistance mV/V %S V Ω Ω Ω Nonlinearity according to VDI / VDE 2638 Hysteresis according to VDI / VDE 2638 Temperature effect on zero/10K Temperature effect on output/10K Temperature coefficient of output signal under load/10K Creep in 30 minutes tolerance of output signal tolerance of zero signal Excitation voltage Input current Output signal for compressive force(0..FN) alternatively: - Voltage output (max. load 5mA) - Current output 0,2 0,1 0,5/1/2/5/10 0,5/1/2/5/10 20/50/100/200 20/50/100/200 150 >500 20 %S %S %S %S %S 150 >500 20 23 -20 . . . .+60 -30 . . . . +70 IP 67 0,2 with integrated amplifier 20/50/100/200 0,5/1/2/5/10/20/50/100/200 150 >500 20 1,000± 0,005 ≤3 10 380 ± 30 352 ± 1,5 >5⋅ 109 ≤0,5 ≤0,5 ≤0,5 ≤0,5 ≤0,2 ≤0,2 ≤0,2 ≤0,2 1,000± 0,005 ≤3 20 760 ± 60 706 ± 6 9 >5⋅ 10 0,1 0,1 0,1 0,1 ≤0,5 ≤0,2 0,1 150 >500 20 23 -20 . . . .+60 -30 . . . . +70 IP 67 0,2 0,2 0,2 % % 0,2 0,2 ≤3 VD mA 19 ... 28 35 (at 24V) V mA 11 ... 15 20 (at 12V) 0 ... 10 0 ... 5 0 (4) ... 20 0 (4) ... 20 (max. burden 300 Ω) (max. burden 100 Ω) O Appliances for Installation and Mounting P top plate L N K L M N O P S M Rated load KAM 20kN/50 kN S KAM 0,5 kN – 10kN ∅40-0,1 55 67 ∅6,6 50 37,5 37 ∅90-0,1 78 103 ∅13,5 100 76 73 KAM 100kN/200kN ∅115-0,1 90 120 ∅13,5 100 76 90 base plate K Type code / Order example KAM/5kN/0,5 KAM-E/1kN/0,2/24V/0...10V (with integrated amplifier) Accessories / Options Top plate Base plate Plug and cable Type code XKM 072 XKM 070 XKM 071 XKM 096 XKM 094 XKM 095 XKC 041 XKC 044.01 XKC 046.03 Description Top plate for KAM 0,5 kN to 10 kN Top plate for KAM 20 kN and 50 kN Top plate for KAM 100 kN / 200 kN Base plate for KAM 0,5 to 10kN Base plate for KAM 20/50 kN Base plate for KAM 100 kN / 200 kN 6 pin plug connected to sensor cable Connector male, mounted to sensor body, 5 pin Connecting cable 5m for XKC 044.01 Data sheet KAM Promess Gesellschaft für Montage- und Prüfsysteme mbH To avoid side load introduction and forming due to high surface pressure To avoid hysteresis effects at not screwed-on transducers For connection with display units (AE 702, KMG) Enables releasable cable connections (IP 68) at force transducer Subject to technical changes Tel +49 (0) 30 / 62 88 72 0 05/2006 www.promess.net
© Copyright 2024 ExpyDoc