Switch-Disconnector Switch-Disconnector Mounting instruction Application: ZH series of cam switch can be widely applied in different fields as main circuit and auxiliary circuit and has many ways of changing. When used as a motor controller, it starts, breaks and stops running single phase or three phase motor; also it can be used as delt-star switch, changeover switch and pole changing switch. When in auxiliary circuit, according to the actual function, it can be used as control, signal and test switch. Main body The main innovation of ZH series multi-function cam switch is the module structure design. That is to say, each floor is an independent module, with characteristic of convenient assembly and tight structure. This series of cam switch mainly has specifications, 16A 20A 25A 32A 40A 63A 80A also has four switching angles, 30 , 45 , 60 an 90 , This cam switch has 12 positions at most, it has floor from 1 to 12,with each floor two Modular construction , maximum 12floors Din-Rail Mounting plate pairs of contacts, and the maximum is 24 pair s. The electric functions including single throw, double throw, momentary, normal open, normal close and connecting in advance etc, The module could b e variably combined acc ording to customers requirement. It has multiple assembly specification, mainly with panel assembly and assembly from bottom. The protection degree could reach to IP54 when with enclosure. Structure: The cam switch is consisting of contact box with cam, which is used to control. Each contact box has 2 bi-direction breaking contact, whi ch are connected by the slide bar to force the mobile contact. The contact will break by the force. Switch-Disconnector Switch-Disconnector Type index: AC switch application: ZH-16 Switch load Category Typical applications Normal operation ON Connect /disconnect resistive load, including proper overload Start / break of wound rotor type motor Connect / disconnect resistive load and inductive load including proper overload Start of squirrel cage motor, and breaking in running Connect / disconnect load of motor(main switch)or other high inductive load ( ) Control of AC electromagnetic load Switch Type ZH-16 CSA of single or multicove cable mm2 Fine wire with cable connector mm2 Connecting screw Rated insulative voltage Ui V~ Rated impulsive stand voltage Uimp. kV ZH-20 OFF abnormal operation ON OFF Ie Ie 1.5Ie 1.5Ie 0.95 2Ie 2Ie 4Ie 4Ie 0.65 Ie Ie 3Ie 3Ie 0.8 0.65 2Ie 2Ie 10Ie 8Ie 0.35 0.45 Ie Ie 10Ie 8Ie 0.35 0.45 10Ie Ie 10Ie 10Ie 0.3 ZH-32 ZH-25 ZH-40 ZH-63 ZH-80 0.75-4 1-6 2.5-10 4-16 0.75-2.5 1-4 1.5-6 1.5-10 M3 M4 M5 M5 690 6 3 001 1 1 3 001 1 1 Switch-Disconnector Switch-Disconnector Switch size: ZH-16 ZH-20 Ith=16A Utilization category AC-3 AC-23A/B AC-21A/B Rated operational current and voltage 12A 220-240VAC/2kW 12A 380-440VAC/3.7kW 8A 16A 16A 380-440VAC/5.5kW 12A 600-690VAC/5.5kW 16A 220-240VAC 16A 380-440VAC 16A 600-690VAC 6A 220-240VAC 220-240VAC/2.2kW 16A 380-440VAC/5kW 600-690VAC/3.7kW 10A 220-240VAC/3kW 22A 22A 380-440VAC/7.5kW 15A 600-690VAC/7.5kW 20A 220-240VAC 20A 380-440VAC 20A 600-690VAC 8A 220-240VAC AC-21A/B AC-3 AC-23A/B AC-21A/B 5A ZH-32 Rated operational current and voltage 16A 220-240VAC/3.7kW 19A 380-440VAC/7.5kW 10A 600-690VAC/5.5kW 20A 220-240VAC/5.5kW 25A 380-440VAC/11kW 16A 600-690VAC/11kW 25A 220-240VAC 25A 380-440VAC 25A 600-690VAC 10A 220-240VAC AC-15 AC-23A/B AC-21A/B 380-440VAC Rated operational current and voltage 220-240VAC/4.5kW 27A 380-440VAC/7.5kW 600-690VAC/5kW 16A 600-690VAC/7.5kW 220-240VAC/4kW 45A 220-240VAC/7.5kW 45A 380-440VAC/15kW 28A 600-690VAC/15kW 40A 220-240VAC 40A 380-440VAC 40A 600-690VAC 16A 220-240VAC 8A 380-440VAC AC-3 AC-23A/B AC-21A/B 380-440VAC ZH-63 Rated operational current and voltage 19A 220-240VAC/3.7kW 22A 380-440VAC/7.5kW 12A 600-690VAC/5.5kW 29A 220-240VAC/5.5kW 32A 380-440VAC/11kW 22A 600-690VAC/11kW 32A 220-240VAC 32A 380-440VAC 32A 600-690VAC 14A 220-240VAC 6A 380-440VAC AC-15 5A Utilization category 27A Ith=32A Utilization category AC-3 Ith=45A AC-15 380-440VAC Ith=25A Utilization category AC-23A/B Rated operational current and voltage AC-15 4A AC-3 Utilization category 16A AC-15 ZH-25 ZH-40 Ith=25A Utilization category AC-3 AC-23A/B AC-21A/B ZH-80 Ith=63A Rated operational current and voltage 32A 220-240VAC/5.5kW 36A 380-440VAC/11kW 25A 600-690VAC/11kW 45A 220-240VAC/11kW 50A 380-440VAC/22kW 32A 600-690VAC/22kW 63A 220-240VAC 63A 380-440VAC 63A 600-690VAC Ith=80A Utilization category AC-3 AC-23A/B AC-21A/B Rated operational current and voltage 44A 220-240VAC/7.5kW 44A 380-440VAC/13kW 28A 600-690VAC/13kW 60A 220-240VAC/15kW 60A 380-440VAC/25kW 37A 600-690VAC/25kW 80A 220-240VAC 80A 380-440VAC 80A 600-690VAC Switch-Disconnector Switch-Disconnector Assembly type: Knob options: 1 2 Type Code Type Code 40 36 30 31 40 18 48 65 ZH-16,ZH-20 ZH-25,ZH-32 4.2 50 1 ZH-16,ZH-20 30 48 4 41.5 48 36 23 65 48 40 72 ZH-16,ZH-20 ZH-25,ZH-32 4.2 50 59 2 ZH-25,ZH-32 40 4 65 55 24.3 3 60 48 36 60 50 72 ZH-25,ZH-32 ZH-40 ZH-63,ZH-80 47 85.5 40 71 11.7 4 65 5 67 65 72 4.2 60 70 30 47 ZH-25,ZH-32 ZH-40 ZH-63,ZH-80 4
© Copyright 2024 ExpyDoc