ACTISCREENTM XL-FDP - Sekisui Diagnostics

A C TI S C R E E N ™ XL- F DP
www.sekisuidxcoag.com
MANUAL LATEX AGGLUTINATION TEST FOR D- DI M E R / RAPID SEMI-QUANTITATIVE METHOD
FEATURES AND BENEFITS
4 Accurate, Reliable, Low Cost
ACTISCREEN XL-FDP
TM
Monoclonal antibody (MAb) based latex
agglutination test for the qualitative and
semi-quantitative measurement of cross-linked
fibrin fragments (D-dimer) in human plasma.
The MAb DD-3B6/22 is highly specific for D-dimer,
the test is sensitive to 200 ng/mL of D-dimer.
4 D-dimer evaluation in three
minutes
4 No instrumentation required
4 Perfect for emergency
departments and stat situations
where immediate D-dimer results
are needed
4 Measures only the cross linked
Fibrin Degradation Products (XL-FDP) D-dimer
4 Utilizes monoclonal antibody
DD3B6/22, highly specific for
D-dimer1,2
4 No cross-reactivity with intact
fibrinogen3
4 Over 250 published studies
referencing DD-3B6/22 make
it the ‘Gold Standard’ MAb for
In vitro quantitation of XL-FDP /
D-dimer
D IAG NOS T ICS
A C TI S C R E E N ™ XL- F DP
MA NUA L LATEX AG G L U T IN AT IO N T E S T F O R D-D I M E R IT’S AS EASY AS...
1. A DD 1 DR O P O F X L _ F DP L AT E X 2 . AD D 1 D R O P O F PATI E N T PL AS M A 3. MIX A ND I N CUBAT E 4. R E AD NEG
AT I V
E
POSIT
IVE
The most accurate and sensitive manual XL-FDP / D-dimer test.
www.sekisuidxcoag.com
RAPID SEMI-QUAN T ITAT IVE M E T HO D
1. P REPARE SERIA L DI L UT IO N S O F T HE PAT I E N T
P LASMA WITH B U F F E R
2. PL AC E O N E D R O P O F L ATE X R E AG E N T
W I TH I N A C I R C L E O N TH E TE S T CAR D
3. A DD 20μL OF E ACH DI L UT E D PAT IE N T P L A S M A
OR O NE DR O P O F CO NT R O L ( NO R M A L O R
ABNO RMA L) IN S I DE T HE CIR CL E , NE X T TO TH E
LATEX REAG E NT
4. M I X TH E S AM PL E ( O R C O N TR O L ) AN D T HE
L ATE X R E AG E N T W I TH TH E S TI R R E R PR OV I DED
NEG
5. G ENTLY R OCK T HE T E ST CA R D BACK A ND
FOR TH FO R 3 M I N U T E S T HE N E X A M IN E T H E
REAG ENT AND SA M P L E IN T HE CIR CL E
AT I V
E
POSIT
IVE
6. D E TE R M I N E X L - F D P / D - D I M E R L E V E L S BA S ED
U PO N AG G L U TI N ATI O N PATTE R N
S E E I N S T R UCT I O N S F O R U S E F O R F U L L PR O C E D U R E S MATERIALS SUPPLIED
ACTISCREEN ™ XL-FDP 800DB CONTAINS:
• Latex reagent – 1 x 2,0 mL dropper bottle, white cap
• Positive control – 1 x 0,6 mL dropper bottle, yellow cap
• Negative control – 1 x 0,6 mL dropper bottle, black cap
• Buffer solution – 1 x 20 mL bottle
• Test cards – 10 each with 8 test circles
• Plastic stirrers – 60 for mixing
• Instructions for Use with qualitative and quantitative methods
ORDERING INFORMATION:
ActiScreen™ XL-FDP, Latex kit (60 tests) (Part No. 800DB) IVD
ActiScreen™ XL-FDP, Latex vial (60 tests) (Part No. 800DB-LX) IVD
MANUFACTURED IN THE USA BY:
Sekisui Diagnostics, LLC
500 West Avenue
Stamford, CT 06902
Phone: Sales Technical Service 203 602 7777
Phone: Orders/Customer Service 800 332 1042
Fax: Orders/Customer Service 800 762 6311
Fax: Sales/Technical Service 203 602 2221
E-mail: [email protected]
www.sekisuidxcoag.com
REFERENCES:
1. Rylatt, D.B., et al, An Immunoassay for Human D-dimer using Monoclonal Antibodies, Thromb. Res., 31(6):767-788; 1983
2. Bick, R.L., Disseminated Intravascular Coagulation: Objective Criteria for Clinical and Laboratory Diagnosis and Assessment of
Therapeutic Response, Seminars in Thrombosis & Hemostasis, 22(1):69-88; 1996
3. Greenberg, C.S., et al, Measurement of Plasma Fibrin D-dimer levels with the Use of a Monoclonal Antibody Coupled to Latex Beads,
Am. J. Clin. Pathol., 87(1):94-100; 1987
©2013 Sekisui Diagnostics, LLC – All rights reserved
ActiScreen™ XL-FDP is a registered trademark of Sekisui Diagnostics, LLC
ISO 13485:2003 Registered
80-7987-00-00 04/13