Datasheet ES 962A 1 2 IP-Sub Stations Series ES 962A The IP flushmount sub stations ES 962A and ES 962AM are designed especially for mounting in American “2-Gang“ boxes. The technology allows excellent speech quality and comprehensibility independent of background noise. The stations are prepared for future download of new functions (updates to new versions) and can utilize the OpenDuplex ® capability of Intercom Servers. 1. ES 962A Tamper resistant IP-sub station with programmable call button, electret microphone, 8 Ohm loudspeaker and input for floating contacts. 2. ES 962AM Same as ES 962A but with red mushroom button. Datasheet Version 1.0/0214 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. www.commend.com P1|4 datasheet ES 962A Technical Data – Benefits Technical data Benefits Buttons: • Excellent 16 kHz speech quality, even from a distance (up to 7 m /23 ft) ES 962A: flat button stainless steel ES 962AM: red mushroom button Front panel: Stainless steel, thickness: 3 mm (0.21“) Microphone: Omnidirectional electret microphone for max. 7 m (23 ft) speaking distance Loudspeaker: Special membrane type for optimal sound quality, sound pressure: 85 dB/1 W/1 m (3.28 ft), 8 Ohm Amplifier: built-in amplifier 2.5 W; output power with built-in loudspeaker: 1.5 W Input: 1 input for floating contacts, max. 1 kOhm (detection of 5 input states) Output: 1 relay output 30 V / 1 A Call indication: multifunction LED (colours: red, green, blue) Frequency range: 200 – 16.000 Hz Operating temperature range: –20° C to +70° C (–4°F to 158°F) Storage temperature range: –20° C to +70° C (–4°F to 158°F) Relative humidity: Connection: Power supply: up to 95 % - pluggable screw terminals - expansion plug for e.g. EB2E2AHE PoE (Power over Ethernet): IEEE 802.3af standard Power consumption of the terminal device: Class 1 (< 4 W) Cabling: • IP-technology, prepared for software download of future functions • Audio Monitoring, adjustable integration time and noise level • Microphone-Loudspeaker Monitoring • Built-in loudspeaker and microphone • Integrated amplifier with 2.5 W output • Multifunction LED for indication of status • Output contact for direct connection of e.g. doors or gates • Expansion via optional expansion boards (e.g. EB2E2A) Extent of Supply 1 IP-sub station including short reference Line length in LAN The maximum line length of Cat. 5 cabling in a LAN is 100 m (328 ft) – e.g. from switch to Intercom station. min. Cat. 5 Protocol: IoIP-Protocol based on UDP/IP Data rate: 10/100 MBit/s (Full/Half Duplex) Measurements: Front panel: 115 x 115 mm (4.53 x 4.53 in), mounting depth: 45 mm (1.8 in) without ethernet cable 60 mm (2.4 in) with standard ethernet cable Weight incl. package: 560 g (1.2 lbs) System Requirements • GE 800 (min. PRO 800 3.1) with G8-IP (min. G3-8-IP 5.3) • GE 300 (min. PRO 800 3.1) with G3-IP (min. G3-8-IP 5.3) • Configuration software min. CCT 800 3.1 • Configuration software IPStationConfig (included in setup of CCT 800 3.1) Datasheet Version 1.0/0214 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. www.commend.com P2|4 datasheet ES 962A Installation Mounting Instructions Precautions • • ESD precautions must be observed. • • Do not expose the station to extreme temperature (below –20°C or above +70°C / –4°F to 158°F). The stations are designed especially for building into American “2-Gang“ boxes. Box and mounting screws are not included in the extent of supply. For stations to be mounted in outdoor areas, the screws must be closed with a sealing compound. • The stations may be installed by authorised service engineers only. Measurements Measurements in mm (inch), not scale! 115 (4.53) 23 (0.91) 23 (0.91) Connection Diagram 41.5 (1.64) OUT factory adjusted as “make” contact. With the jumper JP1 it can be converted into a “open” contact. PoE (“Power over Ethernet”): IEEE 802.3af standard, Power consumption of the terminal device: Class 1 View from rear of faceplate R/G/B +5V 470 Ω internal series R 470 Ω G 150 Ω resistors B 115 (4.53) +5V IP Uplink Expansion plug (e.g. for EB2E2AHE) (8–50 Ω) LS– LS+ MIC– MIC+ R3 R2 R1 C3 C2 C1 GND IN1 OUT1 41.5 (1.64) JST plug for external LEDs N/ O mounting holes (4x) ø 5 (0.2) JP1 Front panel thickness: 3 mm (0.12 “) Cleaning Instructions The station may only be cleaned with cleaning agents for stainless steel – in NO case with cleaning agents containing chlorine! Datasheet Version 1.0/0214 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. www.commend.com P3|4 datasheet ES 962A COMMEND A Strong Network | Worldwide Europe SWITZERLAND LIECHTENSTEIN FRANCE SPAIN PORTUGAL ITALY NETHERLANDS BELGIUM LUXEMBURG AUSTRIA SLOVENIA RUSSIA America Commend AG Tel. +41-44-955 02 22 www.commend.ch USA CANADA LATIN AMERICA Commend France S.A.S. Tel. +33-149 18 16 40 www.commend.fr Commend Ibérica S.L. Tel. +34-91-395 24 98 www.commend.es Commend Italia S.R.L. Tel. +39-035-95 39 63 www.commend.it Commend Benelux B.V. Tel. +31-76-200 01 00 www.commend.nl Commend Österreich GmbH Tel. +43-1-715 30 79 www.commend.at Asia-Pacific AUSTRALIA NEW ZEALAND CHINA SINGAPORE HUNGARY CROATIA SERBIA BOSNIA-HERZEGOVINA Commend Inc. Tel. +1-201-529-2425 www.commendusa.com Commend Adria d.o.o. Tel. +385-1-369 11 23 www.commend.hr ISRAEL MONTENEGRO MACEDONIA Commend Australia Tel. +61-3-9729-3700 (Melbourne) Tel. +61-2-4655-5738 (Sydney) www.commend.com.au Commend Business Hub China Tel. +86-21-52 13 19 28 www.commend.cn Commend Business Hub Asia Isolectra Far East Pte. Ltd Tel. +65-6272-2371 www.commend.com.sg Sberlophone Ltd Tel. + 972-4-834 10 32 www.sberlophone.co.il KOSOVO ALBANIA SLOVAKIA CZECH REPUBLIC UNITED KINGDOM IRELAND SWEDEN NORWAY FINLAND DENMARK Commend Slovakia spol. s r.o. Tel. +421-2-58 10 10 40 www.commend.sk Commend UK Ltd Tel. +44-1279-87 20 20 www.commend.co.uk Commend Business Hub Nordic JNT Sound System AB Tel. +46-8-99 30 60 www.jnt.se ICELAND POLAND Africa SOUTH AFRICA ALGERIA TUNISIA MOROCCO Commend Business Hub South Africa Evolving Management Solutions (Pty) Ltd Tel. +27-11-274 6665 www.commend.co.za Commend France S.A.S. Tel. +33-149 18 16 40 www.commend.fr C&C Partners Telecom Sp.z o.o. Tel. +48-65-525 55 55 www.ccpartners.pl Other countries GERMANY Schneider Intercom GmbH Tel. +49-211-88285-333 www.schneider-intercom.de Commend International GmbH Tel. +43-662-85 62 25 www.commend.com Datasheet Version 1.0/0214 | Errors and omissions excepted | Products may change in the interest of technical improvements without notice. www.commend.com P4|4
© Copyright 2024 ExpyDoc