GW System, 4 Branches Series EX500

GW System, 4 Branches
Series EX500
®
Valve manifold and input unit manifold can be connected around the GW unit.
Compatible with various protocols by replacing the GW unit.
Compatible with 64-digital-outputs (16 points x 4 branches) and 64-digital-inputs (16 points x 4 branches).
GW unit, Input unit manifold: IP65
Valve manifold including SI unit: IP67
GW unit
Input unit
SI unit
EX12
VQC1000
2000
4000
SI unit
EX140
EX180
EX260
EX250
EX600
EX500
Input unit
EX510
SV1000/2000/3000/4000
PCA
EX
2111
GW System, 4 Branches
Series EX500
®
How to Order GW Unit
GW Unit
EX500 G DN1
Communication protocol
DN1
PR1A
EN1
DeviceNet™
PROFIBUS DP
EtherNet/IP™
GW Unit Specifications
EX500-GDN1
EX500-GPR1A
EX500-GEN1
Protocol
DeviceNet™
PROFIBUS DP
Version Note 1)
Release 2.0
DP-V0
EtherNet/IP™
Release 1.0
Communication speed
125 k/250 k/500 kbps
9.6 k/19.2 k/45.45 k/
93.75 k/187.5 k/500 k/
1.5 M/3 M/6 M/12 Mbps
10 M/100 Mbps
Configuration file Note 2)
EDS file
GSD file
EDS file
Model
Communication
Applicable
system
Power
supply
voltage
I/O occupation area
(Inputs/Outputs)
64/64
64/64
128/128
Terminating resistor
Not provided
Built into the unit
(Switch setting)
Not provided
For unit
For sensors
11 to 25 VDC
(Supplied by DeviceNet™
circuit, 50 mA or less)
For valve
Internal current consumption (Unit)
24 VDC±10%/–5%
200 mA or less (GW unit)
Input
Number of inputs
Connection input device
64 inputs (16 inputs x 4 branches)
The EX500 series input unit manifold (connection from communication port A to D)
Supply voltage
24 VDC
Supply current
Max. 2.8 A (Max. 0.7 A per branch)
Output
Number of outputs
Connection output device
64 outputs (16 outputs x 4 branches)
The EX500 series SI unit manifold (connection from communication port A to D)
Supply voltage
24 VDC
Supply current
Max. 3.0 A (Max. 0.75 A per branch)
Branch cable length
Enclosure
Environment
24 VDC±10%
24 VDC±10%
Operating temperature range
Operating humidity range
Withstand voltage
Insulation resistance
5 m or less between connected devices (total extension 10 m or less)
IP65
Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation)
Operating, Stored: 35 to 85%RH (with no condensation)
1000 VAC for 1 minute between terminals and housing
2 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Standards
CE marking, UL (CSA)
Weight
Accessory: Waterproof cap (for M12 connector socket)
EX9-AWTS (4 pcs.)
470 g
EX9-AWTS (5 pcs.)
EX9-AWTS (5 pcs.)
Note 1) Please note that the version is subject to change.
Note 2) Each file can be downloaded from SMC website (http://www.smcworld.com).
Note 3) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).
A
2112
Series EX500
GW System, 4 Branches
GW Unit Dimensions/Parts Description
GATEWAY UNIT
PE
EX500 SERIES
BUS
MS
NS
COM A
COM B
COM C
Branch connector Note 2)
Marker: BN-WH
(Made by PHOENIX CONTACT)
160
GATEWAY UNIT
EX500 SERIES
IN
RUN
SOL
BUS
BF
DIA
OUT
24VDC
COM A
COM B
COM C
Branch connector Note 2)
COM D
Marker: BN-WH
(Made by PHOENIX CONTACT)
160
136
EX500-GEN1(EtherNet/IP™)
10
46
48.8
10
136
Communication
connector
(M12, 4 pins,
socket type D)
Communication
connector
(M12, 5 pins,
socket reverse key)
Power supply
connector Note 1)
COM D
M3
Ground terminal
Position indicator LED
Switch protective
cover
148
4 x M5 (mounting hole)
M3
Ground terminal
Position indicator LED
46
24VDC
88
12
68
SOL
4 x M5 (mounting hole)
148
49.9
Power supply
connector Note 1)
Communication
connector
(M12, 5 pins, plug
reverse key)
68
M3
Ground terminal
Position indicator LED
Switch protective
cover
EX500-GPR1A(PROFIBUS DP)
88
148
PE
Communication
connector
(M12, 5 pins, plug)
12
Switch protective
cover
4 x M5 (mounting hole)
EX500-GDN1(DeviceNet™)
Note 1) Power supply connector specification
(M12, 5 pins, plug)
Note 2) Branch connector specification
(M12, 8 pins, socket)
EX12
GATEWAY UNIT
PE
EX500 SERIES
LAN
EX140
100
Power supply
connector Note 1)
COM A
Branch connector Note 2)
COM B
COM C
EX180
COM D
EX260
Marker: BN-WH
(Made by PHOENIX CONTACT)
EX250
EX600
160
136
EX510
48.8
46
EX500
10
24VDC
88
12
NS
68
MS
PCA
EX
2113
A
Series EX500
How to Order Input Manifold
Input Unit Manifold
EEX500 IB1
How to Order Input Block
E 8
EX500 IE 1
Block type
Connector type
E
T
M
M8 connector
M12 connector
M8, M12 mixed
M8 connector, 2 inputs, PNP specifications
1
M8 connector, 2 inputs, NPN specifications
2
M12 connector, 2 inputs, PNP specifications
3
M12 connector, 2 inputs, NPN specifications
4
5 M8 connector, 8 points integrated type, PNP specifications
6 M8 connector, 8 points integrated type, NPN specifications
Stations
1
1 station
8
8 stations
For options, refer to pages 2120 to 2122.
Input unit
Input block (M8 connector)
Input block (M12 connector)
End block
DIN rail
8 points integrated type input block (M8 connector)
How to Order Input Unit Manifold [Ordering Example]
When ordering an input unit manifold, enter the Input manifold part no. + Input block part no. .
The Input unit , End block and DIN rail are included in the input manifold. Refer to the indications below.
Block part no.
entry
Input unit side
Example 1) M8 input block only
End block side
Example 2) M12 input block only
Input manifold
EEX500-IB1-E8 (1 set)
Input unit side
Input unit side
Input block
EX500-IE5 (2 sets)
EX
50
0-IB
1
EX
50
Input manifold
EEX500-IB1-T4 (1 set)
Input block
EX500-IE4 (4 sets)
EX
50
0-IB
1
0-IE
5 (P
NP
)
EX
50
0-IE
5 (P
NP
)
EEX500-IB1-E8 ...... 1 set
∗ EX500-IE5 ........... 2 sets
EEX500-IB1-T4 ...... 1 set
∗ EX500-IE4 ........... 4 sets
End block side
Input unit side
Input manifold
EEX500-IB1-E8 (1 set)
Input block
EX500-IE1 (8 sets)
EX
50
0-IB
1
End block side
Example 3) M8, M12 mixed
Input unit side
EEX500-IB1-E8 ...... 1 set
∗ EX500-IE1 ........... 8 sets
EX
50
0-IB
End block side
Input manifold
EEX500-IB1-E6 (1 set)
Input block
EX500-IE5 (1 set)
Input block
EX500-IE1 (2 sets)
Input unit side
EX
50
0-IB
1
TY
PE
1
EX
50
0-IE
5 (P
NP)
TY
PE
1
EEX500-IB1-E6 ...... 1 set
∗ EX500-IE5 ........... 1 set
∗ EX500-IE1 ........... 2 sets
End block side
2114
1
Input manifold
EEX500-IB1-M6 (1 set)
Input block
EX500-IE1 (4 sets)
Input block
EX500-IE3 (2 sets)
EEX500-IB1-M6 ...... 1 set
∗ EX500-IE1 ........... 4 sets
∗ EX500-IE3 ........... 2 sets
End block side
Note) • Since the 8 points integrated type input block is
equivalent to the length of four stations on an M8 input
block, pay attention to the number of stations on an
input manifold.
• When an input block layout becomes complicated,
indicate in the input unit manifold specifications sheet.
GW System, 4 Branches
Series EX500
Input Unit Specifications
EX500-IB1
Model
100 mA or less
Internal current consumption
Input
Number of inputs
16 inputs
Connection block
The EX500 series input block (mixed combination is possible)
Connection block
stations
2-input, input block: Max. 8 stations
8-input, input block: Max. 2 stations
Enclosure
IP65
Operating temperature range
Environment
Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (with no condensation)
Withstand voltage
1000 VAC for 1 minute between whole live part and enclosure
2 MΩ or more (500 VDC mega meter) between whole live part and enclosure
Insulation resistance
Standards
CE marking, UL (CSA)
Weight
100 g (Input unit + End block)
Input Block Specifications
Model
Input type
EX500-IE1
EX500-IE2
24 VDC
Input device supply current
Max. 480 mA/Input unit manifold
Rated input current
Approx. 5 mA
Connector on the
input device side
EX500-IE5
EX500-IE6
8 inputs
Input device supply voltage
EX12
EX140
Green LED (Lights up when power is turned ON.)
Display
M8 connector (3 pins, plug)
M12 connector (4 pins, plug)
M8 connector (3 pins, plug)
IP65
Enclosure
Environment
EX500-IE4
2 inputs
Number of inputs
Input
EX500-IE3
PNP sensor input NPN sensor input PNP sensor input NPN sensor input PNP sensor input NPN sensor input
Operating temperature range
Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (with no condensation)
Withstand voltage
1000 VAC for 1 minute between terminals and housing
Insulation resistance
Weight
(for M8 connector socket)
Accessory:
Waterproof cap (for M12 connector socket)
EX260
EX250
EX600
2 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Standards
CE marking, UL (CSA)
40 g
55 g
EX9-AWES (2 pcs.)
—
EX9-AWES (8 pcs.)
—
EX9-AWTS (2 pcs.)
—
20 g
EX180
EX500
EX510
PCA
EX
Note) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).
2115
Series EX500
Input Unit Manifold Dimensions/Parts Description
Input block (M8) only
Connector for input device connection
(M8, 3 pins, socket)
47
(Pitch)
P = 12
31
8
21
DIN rail
49
35
5.5
Branch connector
(M12, 8 pins, plug)
(L4)
L3
L2
Position indicator LED
5
(Rail mounting pitch: 12.5)
C
US
TYPE 1
C
TYPE1
US
MADE IN JAPAN
MADE IN JAPAN
EX500-IE1
(PNP)
C
EX500-IE1
(PNP)
TYPE 1
US
MADE IN JAPAN
TYPE 1
C
US
MADE IN JAPAN
EX500-IE1
(PNP)
EX500-IE1
(PNP)
TYPE 1
C
US
MADE IN JAPAN
C
EX500-IE1
(PNP)
TYPE 1
US
MADE IN JAPAN
EX500-IE1
(PNP)
TYPE 1
C
US
MADE IN JAPAN
EX500-IE1
(PNP)
TYPE 1
C
US
C
MADE IN JAPAN
TYPE 1
US
39.7
24VDC/650mA
16
IP65
32.2
EX500-IE1
(PNP)
EX500-IB1
VOLTAGE
INPUT
IP CODE
SERIAL NO.
Marker: BN-WH
(Made by PHOENIX CONTACT)
(7.5)
44.2
L1
MADE IN JAPAN
(mm)
1
Stations
Rail length L1
2
3
98
110.5 123
100
4
5
6
135.5 148
Mounting pitch L2
87.5
Manifold length L3
74
86
98
L4
12
12
12.5
112.5 125
110
7
8
160.5 173
185.5
137.5 150
162.5 175
122
134
146
13
13
12.5
158
13.5
13.5
Input block (M12) only
Branch connector
(M12, 8 pins, plug)
DIN rail
25
(L4)
5
EX500-IB1
VOLTAGE
INPUT
IP CODE
EX500-IE3
EX500-IE3
24VDC/650mA
16
IP65
C
US
TYPE1
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
SERIAL NO.
US
TYPE1
EX500-IE3
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
US
TYPE1
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
US
TYPE1
EX500-IE3
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
US
TYPE1
EX500-IE3
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
US
TYPE1
EX500-IE3
EX500-IE3
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
US
EX500-IE3
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
TYPE1
US
(PNP)
VOLTAGE 24VDC/60mA
IP CODE
IP65
C
TYPE1
US
TYPE1
MADE IN JAPAN
(mm)
Stations
Rail length L1
1
2
3
4
110.5 123
148
173
5
6
7
8
185.5 210.5 223
248
Mounting pitch L2
100
112.5 137.5 162.5 175
200
212.5 237.5
Manifold length L3
82
102
162
182
202
L4
12
12
13
13
2116
122
12.5
142
12.5
13.5
222
13.5
(7.5)
44.2
L1
46.9
Marker: BN-WH
(Made by PHOENIX CONTACT)
(Rail mounting pitch: 12.5)
32.2
L3
L2
Position
indicator LED
60
35
31
5.5
8
(Pitch)
P = 20
Connector for input
device connection
(M12, 4 pins, socket)
47
31
GW System, 4 Branches
Series EX500
Input Unit Manifold Exploded View
w
a
e
q
r
a
t
EX12
y
EX140
Parts List
No.
Part no.
For standard
Description
EX180
Note
1
Input unit
EX500-IB1
2
Input block (M8 connector)
EX500-IE
3
Input block (M12 connector)
EX500-IE
PNP specifications ... : 1, NPN specifications ... : 2
PNP specifications ... : 3, NPN specifications ... : 4
4
Input block (M8 connector) 8 points integrated type
EX500-IE
PNP specifications ... : 5, NPN specifications ... : 6
5
End block
6
DIN rail
EX260
EX250
EX600
EX500-EB1
VZ1000-11-1-
: No. based on L dimension (Refer to the table below.)
EX500
How to add input block stations
z Loosen the screws
EX510
(2 places) that hold the end block.
PCA
EX
x Separate the blocks at the locations where stations are to be added.
c Attach the additional blocks to the DIN rail, and connect the blocks so that they fit together securely.
v While holding the blocks together so that there are no gaps between them, secure them to the DIN rail by tightening the screws
Note: Be sure to tighten the round head combination screw with the prescribed tightening torque. (0.6 N·m)
.
DIN Rail L Dimension [mm]
Stations
M8 input block (m)
0
M12 input block (n)
0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
1
1
2
3
4
5
6
7
2
2
3
4
5
6
7
8
3
4
5
6
7
8
9
4
6
7
8
9
10
5
7
8
9
10
6
9
10
11
7
10
11
8
12
Connector type
For M (m + n = 2 to 8)
Connector type
For E (m = 1 to 8)
L dimension
No. L dimension No. L dimension
0
98
7
185.5
1
110.5
8
198
2
123
9
210.5
3
135.5
10
223
4
148
11
235.5
5
160.5
12
248
6
173
Connector type
For T (n = 1 to 8)
2117
Series EX500
How to Order SI Unit
SI Unit
EX500
SV1000/2000/3000/4000
S001
Applicable solenoid valve: Series SV
M
R
For options, refer to pages 2120 to 2122.
CO
PW
D
D
D
D
D
D
SI Unit Specifications (EX500-S001)
EX500-S001
Model
Internal current consumption
100 mA or less
Number of outputs
16 outputs
Output type
Output
Sink/NPN (Positive common)
Positive common compatible
Solenoid valve (single, double)
Relay output module (1 ouput, 2 outputs)
Connection block
Double solenoid valve, relay output module (2 outputs): Max. 8 stations
Single solenoid valve, relay output module (1 output): Max. 16 stations
Connection block stations
Connection block supply current
Max. 0.65 A
Enclosure
IP67
Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation)
Operating temperature range
Environment
Operating humidity range
Operating, Stored: 35 to 85%RH (with no condensation)
Withstand voltage
1000 VAC for 1 minute between terminals and housing
2 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Insulation resistance
Standards
CE marking, UL (CSA)
Weight
115 g
Accessory: Waterproof cap (for M12 connector socket)
EX9-AWTS (1 pc.)
Note) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).
SI Unit Dimensions/Parts Description
EX500-S001
Position indicator LED
79.4
28.6
15.5
2118
Branch connector
(M12, 8 pins, socket)
Branch connector
(M12, 8 pins, plug)
39
54.5
68.5
GW System, 4 Branches
Series EX500
How to Order SI Unit
SI Unit
SY3000/5000
VQC1000/2000/4000
EX500
S0700
Q001
Applicable solenoid valve:
Series SY/VQC/S0700
Output specifications
0
1
NPN (Positive common)
PNP (Negative common)
SI unit type
1
2
Note) SY3000/5000, VQC1000/2000/4000, S0700 are not yet UL-compatible.
For without EX9 output block
For EX9 output block mounting
For options, refer to pages 2120 to 2122.
SI Unit Specifications (EX500-Q0)
EX500-Q001
Model
Internal current consumption
EX500-Q002
Output type
16 points
Sink/NPN (Positive common) Source/PNP (Negative common) Sink/NPN (Positive common) Source/PNP (Negative common)
Connection block
Positive common compatible Negative common compatible
Solenoid valve (single, double) Solenoid valve (single, double)
Connection block
stations
Double solenoid valve: Max. 8 stations
Single solenoid valve: Max. 16 stations
Positive common compatible Note) Negative common compatible Note 1)
Output block, power block
Output block, power block
Solenoid valve (single, double) Solenoid valve (single, double)
Double solenoid valve, output block: Max. 8 stations
Single solenoid valve: Max. 16 stations
∗ Power block is not included.
Connection block supply current
Max. 0.75 A
Enclosure
Environment
EX500-Q102
100 mA or less
Number of outputs
Output
specifications
EX500-Q101
EX140
IP67
Operating temperature range
Operating: 5 to 45°C Stored: –25 to 70°C (with no freezing and condensation)
Operating humidity range
Operating, Stored: 35 to 85%RH (with no condensation)
Withstand voltage
1000 VAC for 1 minute between terminals and housing
EX180
EX260
2 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
Insulation resistance
Standards
CE marking, UL (CSA)
Weight
EX250
105 g
Accessory: Waterproof cap (for M12 connector socket)
EX12
EX9-AWTS (1 pc.)
EX600
Note 1) For details of output block and power block, refer to page 2120.
Note 2) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).
EX500
SI Unit Dimensions/Parts Description
EX500-Q01
EX510
PCA
EX
EX500-Q02
Position indicator LED
series
EX500
COM
PWR
SI UNIT
COM
2 x M4 (mounting hole)
66
80.3
80.3
28
36
64.4
0
Branch connector
(M12, 8 pins, socket)
0
Branch connector
(M12, 8 pins, socket)
1
Branch connector
(M12, 8 pins, plug)
1
Branch connector
(M12, 8 pins, plug)
60
64.4
60
PWR
Position indicator LED
85.7
44
2119
Series EX500
Options
 Output block/ Power block
Features: • Possible to retrofit to the valve manifold, using the unused points.
• 2-output/1-output block (M12 connector)
• Positive/Negative common available as standard.
• Possible to drive by up to 0.5 A per a point. (EX9-OEP)
Output block
How to Order Output Block
EX9
How to Order Power Block
OE T 1
EX9
Output specifications
1
2
P
Description
Internal power supply method
(for low-wattage load)
Integrated power supply method
(for high-wattage load) Note)
Output
Source/PNP (Negative common)
Sink/NPN (Positive common)
Refer to page 2169.
When ordering separately: 10 pcs.
Power cable with
connector
EX9-AC-1
Refer to page 2168.
Order separately.
Applicable model
EX9-OET2, EX9-OEP2
EX9-OET1, EX9-OEP1
Option/Part No.
Description
Waterproof cap
Part no.
EX9-AWTS
Cable with connector
EX9-AC-7
for output entry
Power block
2120
EX9-PE1
Applicable model
OET
OEP




—

Note
EX9-AWTS
SI Unit Part No.
SI unit part no.
Part no.
Waterproof cap
Note) Required to connect with a power block.
EX500-Q002
EX500-Q102
PE1
Option/Part No.
Source/PNP (Negative common)
Sink/NPN (Positive common)
Power supply type
T
Power block
Note
Refer to page 2169.
Order separately: 10 pcs.
Refer to page 2169.
Order separately.
Refer to the right page.
Order separately.
GW System, 4 Branches
Series EX500
Output Block Specifications
EX9-OET1
Model
EX9-OET2
Output connector
Internal current consumption
Output type
Power supply method
Sink/NPN (Positive common)
Display
Source/PNP (Negative common)
Sink/NPN (Positive common)
2 outputs
Internal power supply method
Integrated power supply method (Power block: supplied from EX9-PE1)
Output device supply voltage
Output device supply current
24 VDC
Max. 42 mA/point (1.0 W/point) Note)
Max. 0.5 A/point (12 W/point)
Yellow LED (Lights up when power is turned ON.)
Connector on the
output device side
M12 connector (5 pins, plug)
Enclosure
IP67
Operating temperature range
Environment
EX9-OEP2
40 mA or less
Source/PNP (Negative common)
Number of outputs
Output
EX9-OEP1
M12 connector (5 pins)
Operating humidity range
Withstand voltage
Insulation resistance
Standards
–10 to 50°C
35 to 85%RH (with no condensation)
1500 VAC for 1 min. between whole external terminal and FG
10 MΩ or more (500 VDC) between whole external terminal and FG
CE marking, UL (CSA)
Weight
120 g
Note) The rated load current varies due to the output capability of the SI unit when connected to EX500.
Power Block Specifications
Model
Connection block stations
Output block: Max. 8 stations
Power supply voltage
22.8 to 26.4 VDC
Internal power consumption
20 mA or less
Supply current
EX180
Max. 3.1 A (When using with 3.0 to 3.1 A, the ambient temperature should not exceed 40°C, and do not bundle the cable.)
Enclosure
Environment
EX140
Output block (for high-wattage load)
Connection block
Power supply for
output and internal
control
EX12
EX9-PE1
IP67
Operating temperature range
–10 to 50°C
Operating humidity range
35 to 85%RH (with no condensation)
Withstand voltage
Insulation resistance
Standards
Weight
Accessory: Waterproof cap (for M12 connector socket)
EX260
EX250
EX600
EX500
1500 VAC for 1 min. between whole external terminal and FG
10 MΩ or more (500 VDC) between whole external terminal and FG
EX510
CE marking, UL (CSA)
PCA
EX
120 g
EX9-AWTS (1 pc.)
Note) For detailed specifications other than the above, refer to the operation manual that can be downloaded from SMC website (http://www.smcworld.com).
2121
Series EX500
Options
Output Block Dimensions
Power Block Dimensions
Position indicator LED
80.3
72.6
Position indicator LED
PWR
59.8
59.8
22.2
43.2
(M12, 5 pins, socket)
43.2
Power supply connecor
(unused)
21.2
Power supply input connector
(M12, 5 pins, plug,
reverse keyway)
22.2
Connector for
output device connection
21.2
21
21
26.7
26.7
We sell this product individually. Please place an order separately.
You are requested to connect it to an SI unit and a valve manifold.
When using the output block only (valve manifold is unused.), place an order for an end plate (EX9-EA03) separately for connection.
Refer to the operation manual for connection, wiring, installation, option and cable, etc.
 End plate
EA03
2 x M4 (mounting hole)
12.5
EX9
66
13.2
60
10
75
2122
6
18