San Telequip (P) Ltd., 4 Crystal House, 235, Navi Peth Off LBS Road, Pune 411 030, India Phone : 91-20- 24320023, 24334423, 65001587 email : [email protected] Connecting. Converting. Leading ! . BMS Automation Protocol Converter BMS Converter is an external Building and Industrial Automation multi-protocol device server for OEMs wanting to provide protocol translation between Serial-Serial, Serial- Ethernet and Ethernet-Ethernet devices using LonWorks®, BACnet, Metasys N2, Modbus and more. The extensive driver library, coupled with our experience in protocol translation gateways provides the OEM customer with confidence that their products will meet the foreign networks requirements for interfacing. The Converter includes all the hardware and software to enable the customer’s products to interface to various networks. Each Bacnet Converter is provided with the necessary protocol drivers. Multiple drivers can be installed on a single Converter. We can provide custom driver support when needed. Features/Benefits √ √ √ √ √ √ The most flexible and versatile multi-protocol Device Server on the market. Supports virtual nodes allowing multiple OEM controllers to connect to a single converter and seen as separate controllers on the various field networks. TRUE protocol translation and not Protocol packet Encapsulation. Interfaces to over 85 Building and Industrial Automation Protocols. Multi-Client and Multi-Server support ensures interoperability between any Industrial and or Building Automation protocols. Flash upgradeable. Specifications SERIAL PORT : 1 RS-485, 2 Wire, 2 Pin Screw type terminal. SERIAL PORT : 2 ( Optional depending on the second Protocol selected ) RS-485, 2 Wire, 2 or 3 Pin Screw type terminal. 1 Ethernet : 10/100 Ethernet port Connector : RJ45 Indications : LED’s for Tx, Rx, Power Operating Power Requirements Connector : 24V DC, Range 18 to 30 VDC : 2 Pin Screw type Environmental Operating Temp. Relative Humidity : -40°C to 85°C : 5-90% RH, non-condensing Enclosure Dimensions(Lx W x H) : 10.0 x 7.0 x 4.2 cm (GW BMS01 ,GW BMS 02 & GW BMS 05) : 9 . 5 x 10.0 x 4.2 cm (GW BMS 03) : 9.7 x 8.1 x 4.2 cm (GW BMS 04 & GW BMS 02-02) Mounting : DIN Rail Approvals BACnet Testing Labs (BTL) pending San Telequip (P) Ltd., 4 Crystal House, 235, Navi Peth Off LBS Road, Pune 411 030, India Phone : 91-20- 24320023, 24334423, 65001587 email : [email protected] Supported Host Side Protocols RS-485 Modbus RTU Allen Bradley DF1 BACnet MS/TP Metasys N2 LON Ethernet (10/100Base-T) to the OEM’s device: Allen Bradley EtherNet/IP BACnet IP BACnet Ethernet Modbus TCP/IP Supported field protocols: Automation Protocols RS-485 Allen Bradley DF1 DNP 3.0 TL1 Telnet Ethernet (10/100BaseT) Allen Bradley CSP GE-EGD GE-SRTP OPC, SNMP Connecting. Converting. Leading ! . San Telequip (P) Ltd., 4 Crystal House, 235, Navi Peth Off LBS Road, Pune 411 030, India Phone : 91-20- 24320023, 24334423, 65001587 email : [email protected] Connecting. Converting. Leading ! . Ordering Information : Model Protocols handled GW BMS 01 Mobus RTU BACnet IP GW BMS 02 GW BMS 02-02 BACnet MSTP BACnet MSTP (2 RS485 ports) Modbus RTU (2 RS485 ports) Metasys N2 (2 RS485 ports) Metasys N2 & BACnet MSTP(1 & 2 RS485 ports Resp.) (At One time 3 Protocol Supports) BACnet IP BACnet IP BACnet IP BACnet IP BACnet IP GW BMS 03 A GW BMS 03 B GW BMS 03 B BACnet IP Modbus RTU BACnet MSTP Lonworks Lonworks Lonworks GW BMS 04-A GW BMS 04-B GW BMS 04-C GW BMS 04-D Modbus RTU BACnet IP BACnet MSTP BACnet MSTP Metasys N2 Metasys N2 Metasys N2 Mobus RTU GW BMS 05-A GW BMS 05-B GW BMS 05-C BACnet IP SNMP SNMP Modbus TCP BACnet IP Modbus TCP NOTE : 1. 31 devices can be multidropped on the Modbus RTU / BACnet MSTP / N2 side. 2. Depending on site conditions this figure may increase or decrease. 3. 485 Repeater may have to used in between the 485 chain to meet basic 485 critera’s. 4. Max 1500 points can be mapped from Modbus RTU to BACnet IP & vica versa. 5. 750 SNVT’s can be mapped on LON Gateway.
© Copyright 2024 ExpyDoc