CP ZM 500 short period vertical sensor

CP ZM 500 short period vertical sensor
Operating characteristics
Natural frequency :
Mechanical damping:
Inertial mass:
Transducer:
- type
- damping value
- generator constant
Signal coil:
- resistance
Calibration coil:
- resistance
- motor constant
First parasitic resonant frequency:
Power requirements:
Standard preamplifier:
- output type
- output impedance
- voltage gain
0.5 Hz correction preamplifier:
- output type
- output impedance
- voltage gain
- correction
10 Hz noise level at input:
f0 = 1 Hz, adjustable from 0.6 to 1.4 Hz
< 0.01 for f0 = 1 Hz
766 g ± 2 g
Electrodynamic (magnet and coil)
0.707
2250 V/m.s-1 ± 115 V/m.s-1
137 500 Ω ±7500Ω
950 Ω ± 115 Ω
8 N/A
> 400 Hz
Nominal ±12 V ( ± 3 V to ± 20 V), < ±1 mA
Single ended
< 10 Ω
1, 4, 8 or 32
Single ended
< 10 Ω
1, 4, 8 or 32
+ 12 dB for f < 0.5 Hz
30 pm.s-1 / √Hz
Physical characteristics
Basic dimensions :
- diameter
- height
- weight
Environmental characteristics:
- in use temperature
- waterproof case
- rugged for wet and salt saturated
Atmosphere (IP68 guaranteed)
0.30 m
0.30 m
10.5 Kg
-20 to +60 °C
Poles and zeros (response in velocity V/m.s-1 unit)
(noise spectral density for standard preamplifier)