Medium Voltage Products Type KOKM 072 xA 10 Indoor cable current transformers KOKM 072 xA 10 – These indoor ring core current transformer types supply metering and protection devices at a maximum nominal voltage of 0.72 kV and nominal frequency of 50 or 60 Hz. The transformers can be mounted inside the RMU switchgear. Secondary circuits should be mounted using copper wires with a crosssection 4 mm2 (strand) or 6 mm2 (solid conductor). CTs with secondary current 0,075A are specially designed and applicable for self-powered relay. CT parameters for metering and protection devices (according to IEC 60044-1) Metering Protection Ratio (A) Class * Burden (VA) Ratio (A) Class * Burden (VA) Ith (kA) /sec KOKM 072 BA 100/5 0,2 S 2,5 20/3s; 25/1s KOKM 072 BA 100/5 5P10 4 20/3s; 25/1s KOKM 072 CA 200/5 0,2 S 4 KOKM 072 CA 300/5 0,2 S 4 20/3s; 25/1s KOKM 072 CA 100/5 5P10 2,5 20/3s; 25/1s 20/3s; 25/1s KOKM 072 CA 150/5 5P10 4 KOKM 072 CA 400/5 0,2 S 20/3s; 25/1s 4 20/3s; 25/1s KOKM 072 CA 200/5 5P10 4 20/3s; 25/1s KOKM 072 CA 500/5 KOKM 072 CA 600/5 0,2 S 4 20/3s; 25/1s KOKM 072 CA 300/5 5P10 4 20/3s; 25/1s 0,2 S 4 20/3s; 25/1s KOKM 072 CA 400/5 5P10 4 KOKM 072 BA 20/3s; 25/1s 100/1 0,2 S 2,5 20/3s; 25/1s KOKM 072 CA 500/5 5P10 4 20/3s; 25/1s KOKM 072 CA 200/1 0,2 S 4 20/3s; 25/1s KOKM 072 CA 600/5 5P10 4 20/3s; 25/1s KOKM 072 CA 300/1 0,2 S 4 20/3s; 25/1s KOKM 072 BA 100/1 5P10 4 20/3s; 25/1s KOKM 072 CA 400/1 0,2 S 4 20/3s; 25/1s KOKM 072 CA 100/1 5P10 2,5 20/3s; 25/1s KOKM 072 CA 500/1 0,2 S 4 20/3s; 25/1s KOKM 072 CA 150/1 5P10 4 20/3s; 25/1s KOKM 072 CA 600/1 0,2 S 4 20/3s; 25/1s KOKM 072 CA 200/1 5P10 4 20/3s; 25/1s KOKM 072 CA 100/5 0,5 S 4 20/3s; 25/1s KOKM 072 CA 300/1 5P10 4 20/3s; 25/1s KOKM 072 CA 200/5 0,5 S 4 20/3s; 25/1s KOKM 072 CA 400/1 5P10 4 20/3s; 25/1s KOKM 072 CA 300/5 0,5 S 4 20/3s; 25/1s KOKM 072 CA 500/1 5P10 4 20/3s; 25/1s KOKM 072 CA 400/5 0,5 S 4 20/3s; 25/1s KOKM 072 CA 600/1 5P10 4 20/3s; 25/1s KOKM 072 CA 500/5 0,5 S 4 20/3s; 25/1s KOKM 072 BA 600/5 0,5 S 20/3s; 25/1s 4 20/3s; 25/1s 5P10 4-7 KOKM 072 CA 100200/1* KOKM 072 CA 100/1 0,5 S 4 20/3s; 25/1s KOKM 072 CA 10P10 1,5-3-6 20/3s; 25/1s KOKM 072 CA 200/1 0,5 S 4 20/3s; 25/1s 50-100200/1* KOKM 072 CA 300/1 0,5 S 20/3s; 25/1s KOKM 072 CA 4 300600/1* 5P10 4-7 20/3s; 25/1s KOKM 072 CA 400/1 0,5 S 4 20/3s; 25/1s KOKM 072 CA KOKM 072 CA 4-7 20/3s; 25/1s 0,5 S 4 20/3s; 25/1s 400600/1* 5P10 500/1 KOKM 072 CA 600/1 0,5 S 4 20/3s; 25/1s Type * CTs with classes 0,2 S are also available with classes 0,2 or 0,5 or 1 * CTs with classes 0,5 S are also available with classes 0,5 or 1 Ith (kA) /sec Type * Special secondary reconnectible CTs CT parameters for self-powered relays Type Type KOKM 072BA BA1010_CT1 _CT1 KOKM 072 KOKM072 072CA CA 10 10 _CT2 _CT2 KOKM KOKM 072 072 CA CA 10 KOKM 10 _CT3 _CT3) 0.72/3/0.72/3/- 0.72/3/0.72/3/- 0.72/3/0.72/3/- 0.72/3/0.72/3/- 0.72/3/0.72/3/- 7,2 A 7,2 A 14.4 A 14.4 A 28.8 A 28.8 A 57.6 A 57.6 A 115.2 A 115.2 A 0.075 A 0.075 A 0.288 A 0.288 A 5P80 5P80 0.1 VA 0.1 VA 20 3s KA 20 kA/ 0.075 A 0.075 A 0.288 A 0.288 A 10P80 10P80 0.1 VA 0.1 VA 20 K3s A 20 kA/ 0.075 A 0.075 A 0.288 A 0.288 A 5P80 5P80 0.1 VA 0.1 VA 2020 kA/KA 3s 0.075 A 0.075 A 0.288 A 0.288 A 5P80 5P80 0.1 VA 0.1 VA KA 2020 kA/ 3s 0.075 A 0.075 A 0.288 A 0.288 A 5P80 5P80 0.1 VA 0.1 VA 20kA/ KA 20 3s 25 kA/ 1s 62.5 KA 50/62.5 KA 25 kA/ 1s 62.5 K A 50/62.5 KA 25 kA/ 1s 62.5 KA 50/62.5 KA 25 kA/ 1s 62.5 KA 50/62.5 KA 25 kA/ 1s 62.5 KA 50/62.5 KA E E IP 20 IP 20 E E IP 20 IP 20 E E IP 20 IP 20 E IP 20 IP 20 E IP 20 IP 20 -25 ... +70°C -25 ... +70°C -25 ... +70°C -25 ... +70°C -25 ... +70°C -25 ... +70°C -25 ... +70°C -25 ... +70°C -25 ... +70°C -25 ... +70°C Rated level Rated insulation insulation level Rated primary current Ipn Rated primary current Ipnsecondary Rated current Isn Rated secondary current Isn Test winding Test winding Accuracy class with Accuracy class with relay relay Rated burden Rated burden Rated short-time Rated short-time thermal current Ith 1 s thermal current Ith Rated dynamic Rated dynamic curcurrent Idyn rent Idyn Insulation class Insulation class Protection Protection Working Working temperature temperature range range KOKM 072 CACA 1010 _CT5 KOKM072 072CA CA1010_CT4 _CT4 KOKM KOKM 072 _CT5 E E Note: Another CT parameters (according to customer´s requirement) are available after agreement with manufacturer. Note: Another CT parameters (according to customer´s requirement) are available after agreement with manufacturer. CT dimensions KOKM 072 BA10, CA 10 A P Weight [kg] 1VL4600393R0101 KOKM 072 CA 10 50 2 1,9 1VL4600393R0102 KOKM 072 BA 10 42 3 3,3 1VL4600393R0103 KOKM 072 CA 10 50 3 2,8 ABB s.r.o. ABB s.r.o. PPMV Brno PPMV Brno Videnska Videnska 117 117, 619 00 Brno 619 00 Republic Brno, Czech Republic Czech Tel.: +420 +420547 547152 152602 021 Tel.: +420547 547152 152614 614 +420 Fax: +420 547 152 626 Fax: +420 547 152 626 E-mail:[email protected] E-mail: [email protected] www.abb.com www.abb.com 1VLC000600 Rev.1,en 2014.11.13 Type The data and illustrations in this catalogue are not binding. Thereserve data and this catalogue are notinbinding. We reserve the We theillustrations right to makeinchanges of the content, the course right to make changes of the content, in the courseof technical developof technical development of the product. ment of the product. 1VLC000600-rev.1,en 2012.06.05 Drawing
© Copyright 2025 ExpyDoc