Static-Tribo-Electricity of Powder 2014/12/20 Anatomy of Toner Adhesion with SPM Measurement and Electrostatic Simulation Imaging Society of Japan Technical Committee on Simulation Technology Technical Committee on Toner Technology Masami KADONAGA(Ricoh co.) Jun HIRABAYASHI(Canon Inc.) -ColaboratorsExperiment and Discussion 2 T.Tanaka( Canon ) SPM Measurement and Discussion ISJ:Technical Committee on Toner Technology T. TADA ( Canon )、 T. UEHARA ( TREK )、 H. OHTA ( KYOCERA )、 M. KIMURA ( Fuji Xerox )、 T. KUBO ( Kao )、 H. KOBAYASHI ( Powdertech )、 N. SAWAYAMA ( RICOH )、 C. SUZUKI( Fuji Xerox )、 D. HARADA ( CLARIANT )、 K. HOSHINO ( CHIBA Univ. )、 Y. HOSHINO (TOKYO DENKI Univ. ) Estimation of Charge, Simulation and Discussion ISJ:Technical Committee on Simulation Technology J. HIRABAYASHI( Canon ) 、H. KAWAMOTO( Waseda Univ. )、 N. NAKAYAMA ( Fuji Xerox ) 、 M. NAKANO ( Canon ) 、 T. KAGAWA ( KONICA MINOLTA )、 T. ITOH ( Fuji Xerox ) 、 M. MAEDA ( brother)、 S. HASEBE ( Fuji Xerox ) 、 J. MURAKOSO ( FUJITSU ) Agenda 1 1. Introduction 2. Objective 3. Estimation of Charge Distribution with SPM Measurement 4. Estimation of Adhesion with Charge Distribution obtained from SPM Measurement 5. Analysis of Toner Adhesion with Simulation 6. Conclusion Electrostatic Adhesion 2 Measurement 1 nN ~ 50nN ~100nN Theory(Mirror Force) ~ 2nN ~ Theory(Mirror Force) Measurement +q Freq. D -q Average:30nN Metal(Grounded) Fe = 0.1nN -10 1nN -9 10nN 100nN -8 -7 -6 Log10F q2 4 πε 0 D 2 (ex) Q=2.51fC D=6μm⇒1.55nN Measurements indicate forces on the order of 10x larger than what would be predicted from the mirror force theory. Big Picture of Adhesion Analysis 3 SPM potential SPM Adhesion f orce of par t ly charged t oner s Our Study Potential T. Tada (2013) Measurement > T. Tanaka (2013) Adhesion Measurement Estimation of Adhesion (Simulation) M. Kadonaga (2014) Estimation of Charge Charge Distribution on a Toner J. Hirabayashi (2014) Objective 4 To investigate adhesion mechanism with SPM and simulation Step1 :Estimation of charge distribution with SPM measurement Step2: Estimation of adhesion with the charge distribution Step 3: Analysis of adhesion with simulation 5 Step1:Estimation of charge distribution with SPM measurement Jun HIRABAYASHI(Canon Inc.) Sample Toner Charging 6 Model Toner ISJ standard carrier polystyrene particle + + Additive Fumed Silica (Negative) 5µm Mixing and Charging Toner Carrier Carrier Toner Toner Charging 6 Sample + + 5µm ISJ standard carrier N-02 (T/D:5%) Carrier Toner AEROSIL Fumed Silica (Nega) RY 200 (0.5部) Soken chemical & Engineering SX500H ( polystyrene particle) Measurement with SPM Sample 6 ISJ Standard Carrier Mixed and toner is charged. Toner Q=2~3 fC D=6μm Polystyrene + Additive(Silica) Surface form and Potential 40 nm Toner 2.5 μm Grounded Metal SPM(2013:Canon Tada) 2.5 μm We should estimate a charge distribution from the potential distribution. Charge Estimation using de-Convolution 7 with System Response System Response Point Charge × Potential = System response: Relation between charge and potential Estimated Charge Inverse of System Response Measured Potential = × Theoretically speaking, we can estimate charge distribution with a system response. -1 Estimation of System Response 8 Electrostatic simulation of SPM is carried out. Relation between the position of a charge and induced potential of the probe is obtained. SPM model SPM system response System Response Toner: Flat plane with 6µm thick(ε=3) 80 µm System response is estimated from a 3D3D-electrostatic simulation of SPM. Estimation of Charge Distribution Inverse of System Response Potential -1 9 Estimated Charge = × Estimated Charge Potential from SPM -1 × = Charge distribution on a small area is obtained. Estimation of Charge on the Whole Surface of a Toner Charge on a small area Copy Projection to Sphere 10 Expand to Cube Sphere Mapping Charge distribution on the whole surface of a toner is obtained. Estimation of Charge on the whole surface of a Toner Q=2.5fC Step1:Estimation of charge distribution with SPM measurement shows non-uniform charging! 11 12 Step2: Estimation of adhesion with the charge distribution Masami KADONAGA(Ricoh) Simulation Model (FDM) ①Mesh Making/Setting Toner ③Electrostatic Calculation ②Setting Charge 13 ④Estimation of Adhesion to a Grounded Plane with Maxwell Stress Tensor Adhesion with Charge Distribution Estimated from SPM Measurement 14 Charge Distribution Estimated from Step1 Deposit on the grounded plane Result Electrostatic Simulation Estimation of Adhesion Q=2.5fC Adhesion:135nN (Mirror Force:1.6nN) Appropriate adhesion is obtained with the charge distribution obtained from Step1. Step1. Adhesion with Rotated Charge Distribution Rotated Toner(N=100) 15 Average:68nN (N=100) Appropriate distribution of adhesion is obtained. 16 Step2: Estimation of adhesion with charge distribution offers an appropriate adhesion value! 17 Step 3: Analysis of adhesion with simulation Masami KADONAGA(Ricoh) Anatomy of Adhesion 18 SPM measurements and estimations of charge are laborious work・・・・ Artificial charge-distributions are made by random number. Calculate adhesion Estimated Adhesion of Artificial Toner 19 N=1000 q=3.4fC With Charge Patch on the South Pole Average Adhesion 27nN(N=1000) Appropriate adhesion is obtained with artificial toners. 23 Effect of Location of Charge Patch FE(Whole Toner) 21 3.4fC F= 27nN FEN(Northern Hemisphere) 1.7fC F= 0.89nN FES(Southern Hemisphere) 1.7fC F= 22nN FEN(Northern Hemisphere) << FES(Southern Hemisphere) Charge of Southern Hemisphere is dominant. Num.of Charge Patch/Size v.s. Adhesion 22 Patch Radius:0.4μm Q=3.4fC Patch Radius:0.5μm Q=3.4fC Patch Radius:1.5μm Q=3.4fC Patch Radius:1μm Q=3.4fC Q=3.4fC, N=100 Num.of Charge Patch/Size v.s. Adhesion 23 Average Adhesion[nN] With South-Pole Charge Q=3.4fC, N=100 Non-Uniform Charging Uniform Charging Num.of Charge Patch(Average) NonNon-uniform charging enhances adhesion. 26 Conclusion 24 Step1:Estimation of charge distribution with SPM measurement shows non-uniform charging! Step2: Estimation of adhesion with the charge distribution offers an appropriate adhesion value! Step 3: Anatomy of adhesion with simulation Charge of Southern Hemisphere is dominant. Big Picture of Adhesion Analysis 3 SPM potential SPM Adhesion f orce of par t ly charged t oner s Our Study Potential T. Tada (2013) Measurement > T. Tanaka (2013) Adhesion Measurement Estimation of Adhesion (Simulation) M. Kadonaga (2014) Estimation of Charge Charge Distribution on a Toner J. Hirabayashi (2014)
© Copyright 2025 ExpyDoc