TANA SP 007

TANA SP 007
Linear
24V DC
≤39
lm/W
10.83
W/m
IP20
E356145
PRODUCT SPECIFICATION
Size : H15.8/W16/L51.67-2010mm
Chip :
Toyoda Gosei
Beam angle : Diffused
Colours : White: 2300K/2500K/2700K/3000K/3200K/3800K/5000K
Single colours: Red/Green/Blue/Orange/Amber
Bin/Step :
2 Step MacAdam ellipse
CRI :
≥ 90
Lifetime : 50,000 hours @ 25°C
150°
180°
150°
Operating temp :Ta = -25°C to 60°C (Tc max = 77.3°C)
IP rating :IP20
Finish : Silver anodised
Cover/lens : Diffused
Mounting : Surface mounted concealed clips
120°
120°
90°
90°
100
Connection :Hardwire tails
Control :
1-10V/DMX/DALI (see visDIM range)
200
60°
60°
300
30°
C0/C180
PERFORMANCE DATA for 1000mm @ 3200K
Power consumption
10.83W
Supply voltage
24V DC
Supply current
0.4512A
Luminous flux
422.4lm
0°
cd/klm
30°
C90/C270
Data derived from independent UKAS / IESNA LM-79-08 accredited testing of production samples.
See KKDC website for product document updates.
www.kkdc.co.uk
TANASP007S-05EN-20140425
TANA SP 007
Photometric Test Report
PRODUCT DETAILS
Product name :
TANA SP 007
Stated output :
422lm per metre
Description :
Linear LED shelf light, 3200K, 24V, 10.83W per metre
Quantity/length of product tested :
1 x 100mm
Bin tolerance/#. MacAdams ellipse of chip :
2 Step MacAdam Ellipse (+/- 96K)
ELECTRICAL CHARACTERISTICS
TEST DETAILS
Input Voltage (V DC) :
Input power (W DC) :
Input Current (mA DC) :
Test Standards
20.01
0.89
37
Data from independent UKAS
accredited IESNA
LM-79-08 testing
of production
samples.
Number of hours operated prior to 24
test measurement :
Stabilisation time (minutes) :
90
LIGHT OUTPUT
Total light output (Lumens) :
35
Luminaire efficacy (lm/W) :
39.01
Beam angle :
58°
COLOUR CHARACTERISTICS
Correlated colour temperature (CCT) :
3044K
Colour rendering index (CRI Ra) :
92
Chromaticity coordinates
(CIE 1931 - x,y) :
Duv of test sample :
0.4342, 0.4039
Orientation/burning position :
Base Down
Ambient test temperature :
25.2°C
Data measured at luminaire :
V,W,mA,lm/W
0.0003
COLOUR RENDERING INDEX (CRI)
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
93.2
94.6
92.9
92.9
91.2
92.1
93.2
82.2
56.5
83.9
92.4
69.3
93.8
94.7
POLAR CURVE SPECTRAL RADIANT FLUX
VERSUS WAVELENGTH
150°
180°
150°
120°
120°
8.00E-04
0.415
3000K
3500K
y
0.405
ian
Planck
0.395
0.42
locus
s-line
e-line
90°
90°
100
200
60°
0.425
0.43
x
0.435
60°
Special Radiant Flux (W / nm)
KKDC BIN DETAILS (CIE 1931)
7.00E-04
6.00E-04
5.00E-04
4.00E-04
3.00E-04
2.00E-04
1.00E-04
0.00E+00
350
400
450
300
0.44
30°
C0/C180
0°
cd/klm
30°
500
550 600
650
Wavelength (nm)
700
750
800
C90/C270
TEST SPECIFICATIONS
Test Lab :
LUX-TSI Ltd, Pencoed Technology Park, CF35 5HZ, UK
Test equipment :
40-inch (1metre) Integrating Sphere Spectroradiometer System.
Fluke 289 True RMS Multimeter. Yokogawa TY720 Digital Multimeter.
Total Luminous Flux +/-5.6%, CCT +/-100K, CRI +/-2
Measurement uncertainty :
See KKDC website for product document updates.
www.kkdc.co.uk
TANASP007PR-01EN-20141203