38QRR Performancet Series Heat Pump with Puronr Refrigerant 1---1/2 to 5 Nominal Tons Product Data INDUSTRY LEADING FEATURES / BENEFITS Energy Efficiency S 13 -- 15.5 SEER/10.5 -- 13.5 EER/7.7 -- 9.0 HSPF Sound S Levels as low as 68 dBA Design Features S New aesthetics S Small footprint S WeatherArmort cabinet ⎯ All steel cabinet construction the environmentally sound refrigerant Carrier Heat Pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 38QRR has been designed utilizing Carrier’s Puron refrigerant. This environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. This product has been designed and manufactured to meet Energy Starr criteria for energy efficiency when matched with appropriate coil components. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory (www.ahridirectory.org) for the most up--to--date ratings information. ⎯ Baked on powder paint ⎯ Mesh coil guard Reliability, Quality and Toughness S Scroll compressor S Factory--supplied filter drier S High pressure switch S Low pressure switch S Accumulator S Line lengths up to 250’ (76.2 m) S Low ambient operation (down to --20_F/--28.9_C)) (with low ambient accessories) MODEL NUMBER NOMENCLATURE 8 9 10 11 12 13 N N A/N A/N A/N N N 1 8 A 0 0 3 0 Variations Open Open Voltage Minor Series 1 2 3 4 5 6 7 N N A A A/N N 3 8 Q R R 0 Product Series QRR = Horizontal Discharge Heat Pump Cooling Capacity 38QRR 38=AC/HP A=Standard 0=Not 0=Not Defined Defined 3=208/230 ---1 5=208/230 ---3 6=460/3 0, 1, 2... the environmentally sound refrigerant Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. This product has been designed and manufactured to meet Energy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm proper charge and air flow may reduce energy efficiency and shorten equipment life. PHYSICAL DATA UNIT 38QRR NOMINAL CAPACITY Tons (kg) OPERATING WEIGHT lb (kg) REFRIGERANT TYPE METERING DEVICE CHARGE lb (kg) COMPRESSOR Type Oil Charge (POE --- oz) Crankcase Heater (watts) OUTDOOR FAN Rpm/Cfm Diameter in. (mm) No. Blades Motor (hp) OUTDOOR COIL Face Area (sq ft) No. Rows FPI HIGH PRESSURE SWITCH Cut --- In (psig) Cutout (psig) LOW PRESSURE SWITCH Low Cutout (psig) Low Cut --- in (psig) REFRIGERANT LINES Connection Type Max. Liquid Line (in.) OD Rated Vapor Line* (in.) OD CONTROLS Fusible Plug _F (_C) Control Voltage{ System Voltage FINISH 018 1.5 (1360.8) 167 (75.75) 024 2.0 (1814.4) 176 (79.83) 030 036 2.5 (2268.0) 3.0 (2721.6) 187 (84.82) 232 (105.23) R --- 410A TXV 12.0 (5.44) 12.5 (5.67) 048 4.0 (3628.8) 278 (126.10) 060 5.0 (4536.0) 306 (138.80) 6.8 (3.08) 7.0 (3.18) 12.2 (5.53) 12.8 (5.81) 25.0 — 25.0 — 25.0 40 25.0 40 42.0 40 42.0 40 840/1720 18 (457) 3 1/8 840/1720 18 (457) 3 1/8 850/3900 24 (610) 3 1/4 850/3900 24 (610) 3 1/4 850/3900 24 (610) 3 1/4 850/3900 24 (610) 3 1/4 5.8 3 20 7.3 3 20 12.1 2 20 12.1 3 20 14.1 3 20 14.1 3 20 420 ± 25 650 ± 10 420 ± 25 650 ± 10 420 ± 25 650 ± 10 420 ± 25 650 ± 10 420 ± 25 650 ± 10 420 ± 25 650 ± 10 20 ± 5 45 ± 25 20 ± 5 45 ± 25 20 ± 5 45 ± 25 20 ± 5 45 ± 25 20 ± 5 45 ± 25 20 ± 5 45 ± 25 3/8 5/8 3/8 5/8 3/8 3/4 3/8 3/4 3/8 7/8 3/8 7/8} Scroll Sweat 208/230 v 210 (98.9) 24 vac 208/230 v 208/230 v, Single and 3 Phase, 460 v, 3 Phase Gray 208/230 v * Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. { 24 v and a minimum of 40 va is provided in the fan coil unit. } Valve connection size is 7/8 inch. Recommended line size is 1 ---1/8 inches. FPI --- Fins Per Inch POE --- Polyol Ester 2 VAPOR LINE SIZING AND COOLING CAPACITY LOSS LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is up to 250 ft. (76.2 m). The maximum Vapor Line Diameters (In.) OD Cooling Capacity Loss (%) Total Equivalent Line Length ft. (m) Standard Application 26--- 50 (7.9--- 15.2) 51--- 80 Long Line Application Requires Accessories 81--- 100 101--- 125 126--- 150 151--- 175 176--- 200 201--- 225 226--- 250 (15.5--- 24.4) (24.7--- 30.5) (30.8--- 38.1) (38.4--- 45.7) (46.0--- 50.3) (53.6--- 60.0) (61.3--- 68.6) (68.9--- 76.2) 18,000 1 ---Stage Puron HP 1/2 1 2 3 4 6 7 8 9 10 5/8 0 0 1 1 1 2 2 3 3 24,000 1 ---Stage Puron HP 5/8 0 1 1 2 3 3 4 4 5 3/4 0 0 0 0 1 1 1 1 1 5/8 1 2 3 3 4 5 6 7 8 3/4 0 0 1 1 1 2 2 2 3 7/8 0 0 0 0 1 1 1 1 1 5/8 1 2 4 5 6 7 9 10 11 3/4 0 0 1 1 2 2 3 3 4 7/8 0 0 0 0 1 1 1 1 2 3/4 0 1 2 3 4 5 5 6 7 7/8 0 0 1 1 2 2 2 3 3 3/4 1 2 4 5 6 7 9 10 11 7/8 0 1 2 2 3 4 4 5 5 30,000 1 ---Stage Puron HP 36,000 1 ---Stage Puron HP 48,000 1 ---Stage Puron HP 60,000 1 ---Stage Puron HP 3/8 1 ---1/8 0 0 0 1 1 1 1 1 1 Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines 3 38QRR Unit Nominal Size (Btuh) Maximum Liquid Line Diameters (In.) OD vertical separation is 200 ft. (60.96 m) when outdoor unit is above indoor unit, and up to 80 ft. (24.38 m) when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for the vapor tube diameters based on the total length to minimize the cooling capacity loss. ACCESSORIES KIT NUMBER KAACH1401AAA KAACS0201PTC KAAFT0101AAA KAATD0101TDR KHAIR0101AAA KSAHS1501AAA 53DS---900--- --- ---086 53DS---900--- --- ---070 53DS---900--- --- ---087 53DS---900--- --- ---071 53DS---900--- --- ---088 53DS---900--- --- ---077 53DS---900--- --- ---078 KIT NAME Crankcase Heater PTC Start Assist Evaporator Freeze Stat Time Delay Relay Isolation Relay Capacitor Relay Start Assist Low Ambient Control (Puron) Wind Baffle Wind Baffle Wind Baffle Wind Baffle Wall Mounting Kit Wall Mounting Kit 018 X X X X X X X X 024 X X X X X X X 030 036 048 060 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 38QRR X = Accessory, S = Standard ACCESSORY THERMOSTATS PART NUMBER PROGRAM GAS ELECTRIC HEAT PUMP TP--- PRH01--- A 7 ---Day √ TP--- PHP01 TP--- NRH01--- A 7 ---Day NP TP--- NHP01 TC --- PHP01 NP 5 ---2 Day TC --- NHP01 TCSNHP01 NP NP √ √ √ √ √ √ √ √ √ √ √ √ √ √ PART NUMBER SYSTXCCRRS01 TP--- EXP01--- A TSTATXXCNV10‡ TX--- LBP01 TX--- MBP01 TSTATXXSEN01--- B* √ THERMOSTAT ACCESSORIES BRIEF DESCRIPTION Indoor Remote Room Temperature Sensor ExP Computer Programming Accessory Thermostat Conversion Kit (4 to 5 wire) --- 10 pack Large Decorative Backplate Medium Decorative Backplate Outdoor Air Temperature Sensor INFINITYt* CONTROLS SYSTXCCUID01---A SYSTXCCUIZ01---A SYSTXCC4ZC01 HYBRID HEAT HEAT COOL √ 3 2 √ 3 3 2 2 3 3 2 2 3 2 2 1 THERMOSTATS USED WITH All TP--- thermostats TP---P thermostats All Carrier branded thermostats TP---Pxx, TP---Nxx, TC ---Pxx TC ---Nxx, TB---Pxx All TP--- thermostats DESCRIPTION Infinity Control Deluxe 7--- Day Programmable (Wall--- mounted system control.) Infinity Control Deluxe Zoning 7--- Day Programmable (Wall--- mounted control for a multi--- zone system.) Infinity 4--- Zone Damper Control Module (Wall--- mounted control for a 4--- zone system.) Infinity Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an individual SYSTXCCSMS01 zone.) SYSTXCCRRS01 Infinity Remote Room Sensor (Monitors temperature in an individual zone.) Infinity Network Interface Module (Connects Heat Recovery and Energy Recovery Ventilators or older SYSTXCCNIM01 two--- speed outdoor models to system.) SYSTXXXBPU01 Decorative Back Plate for Infinity Control (Decorative wall plate.) * When applied with Carrier’s IdealHumidityt series variable speed Indoor Models. 4 ACCESSORY USAGE GUIDELINE Accessory Accumulator Ball Bearing Fan Motor Compressor Start Assist Capacitor and Relay REQUIRED FOR LOW --- AMBIENT COOLING APPLICATIONS (Below 55°F / 12.8°C) Standard Yes{ REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 ft. / 24.38 m) Standard No REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles / 3.22 km) Standard No Yes Yes No Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Hard Shutoff TXV Isolation Relay Yes Yes Yes No Yes No No Yes No Liquid Line Solenoid Valve No See Long --- Line Application Guideline No Motor Master® Control or Low Ambient Switch Support Feet Yes No No Recommended No Recommended Accessory Description and Usage (Listed Alphabetically) 6. Isolation Relay An SPDT relay which switches the low--ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Usage Guideline: Required in all heat pumps where low ambient kit has been added. 7. Liquid--Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. Usage Guideline: An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline. 8. Low--Ambient Pressure Switch Kit A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low--ambient temperatures down to 0_F (--18_C) when properly installed. Usage Guideline: A Low--Ambient Pressure Switch or MotorMasterr Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). 9. MotorMasterr Low--Ambient Controller A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to --20_F (--28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ± 5.6_C). Usage Guideline: A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C). Suggested for all commercial applications. 1. Ball--Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when using MotorMasterr 2. Compressor Start Assist -- Capacitor and Relay Start capacitor and relay gives a ”hard” boost to compressor motor at each start up. Usage Guideline: Required for reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single--phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 3. Compressor Start Assist — PTC Type Solid state electrical device which gives a ”soft” boost to the compressor at each start--up. Usage Guideline: Suggested in installations with marginal power supply. 4. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 5. Evaporator Freeze Thermostat An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions. Usage Guideline: Required when low ambient kit has been added. 5 38QRR * For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. (6.09 m) vertical differential, refer to Residential Split---System Longline Application Guideline. { Additional requirement for Low---Ambient Controller (full modulation feature) MotorMasterr Control. Accessory Description and Usage (Listed Alphabetically) -- CONTINUED 38QRR 10. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Carrier thermostats listed in this publication. 11. Outdoor Thermostat An SPDT temperature--actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user--selected set point. Usage Guideline: Electric supplemental heat applications in non--variable speed indoor units when electric heat staging is desired. 12. Secondary Outdoor Thermostat An SPDT temperature--actuated switch which turns on third--stage of supplemental electric heaters when outdoor air temperature drops below the second--stage set point. Usage Guideline: Outdoor thermostat applications where electric heater is capable of 3--stage operation. 13. Snow Stand Rack Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base. Usage Guideline: Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 14. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA. Usage Guideline: Suggested when unit is installed closer than 15 ft. (4.577 m) to quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft. (3.05 m) apart. 15. Thermostatic Expansion Valve (TXV) Bi--Flow A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Usage Guideline: Accessory required to meet AHRI rating and system reliability, where indoor not equipped. Required in all heat pump applications designed with Puron refrigerant. 16. Time--Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: Accessory required to meet AHRI rating, where indoor not equipped. 6 ELECTRICAL DATA 38QRR UNIT SIZE V--- PH --- Hz VOLTAGE RANGE* OUTDOOR FAN MOTOR COMPRESSOR Min Ma x RLA LRA WIRE GUAGE 60_C/75_C WIRE LENGTH 60_C/75_C MIN CKT AMPS FUSE/HACR CKT AMPS 0.09 0.09 0.19 0.19 14/14 14/14 14/14 12/12 61/62 41/39 44/42 60/57 12.1 18.8 17.5 20.9 20 30 30 30 FLA NEC Hp kw Out 0.80 0.80 1.5 1.5 0.125 0.125 0.25 0.25 018 024 030 208/230 ---1 ---60 208/230 ---1 ---60 208/230 ---1 ---60 208/230 ---1 ---60 187 187 187 187 253 253 253 253 9.0 14.4 12.8 15.5 48.0 58.3 64.0 77.0 036 208/230 ---3 ---60 187 253 10.1 71.0 1.5 0.25 0.19 14/14 53/50 14.1 20 460 ---3 ---60 414 506 5.6 38.0 0.80 0.25 0.19 14/14 98/94 7.9 10 208/230 ---1 ---60 187 253 26.5 117.0 1.5 0.25 0.19 8/10 89/54 34.6 50 208/230 ---3 ---60 187 253 16.7 83.1 1.5 0.25 0.19 12/12 55/52 22.4 30 460 ---3 ---60 414 506 7.3 41.0 0.80 0.25 0.19 14/14 79/75 10.0 15 208/230 ---1 ---60 187 253 26.4 134.0 1.5 0.25 0.19 8/10 89/54 34.5 60 208/230 ---3 ---60 187 253 17.7 110.0 1.5 0.25 0.19 12/12 52/50 23.6 40 460 ---3 ---60 414 506 7.8 52.0 .80 0.25 0.19 14/14 72/68 10.6 15 048 060 LEGEND: 38QRR FLA --- Full Load Amps HACR --- Heating, Air Conditininng, Refrigeration LRA --- Locked Rotor Amps NEC --- National Electrical Code RLA --- Rated Load Amps (compressor) * Permissible limits of the voltage range at which the unit will operate satisfactorily NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. A--WEIGHTED SOUND POWER (dBA) Unit Size 018 024 030 036 048 060 Standard Rating (dBA) 68 69 71 72 71 72 Typical Octave Band Spectrum (dBA, without tone adjustment) 125 250 500 1000 2000 4000 8000 54.0 54.0 57.6 61.0 61.1 63.8 56.5 58.0 61.0 60.3 61.6 62.6 61.5 62.5 64.5 63.3 64.0 64.7 63.0 63.5 64.3 64.3 64.8 65.2 59.5 60.0 63.1 63.0 62.9 63.3 56.0 57.5 62.1 64.1 60.0 59.0 45.0 45.5 54.9 56.7 53.3 51.3 CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE) UNIT SIZE 018 024 030 036 048 060 REQUIRED SUBCOOLING _F (_C) 12 (6.7) 13 (7.2) 7 OUTDOOR HEATING PISTON # EA52PJ040 EA52PJ049 EA52PJ055 EA52PJ063 EA52PJ073 EA52PJ080 8 A 38QRR018 38QRR024 38QRR030 38QRR036 38QRR048 38QRR060 F 0 0 0 0 0 0 D B O O O X X X O O O X X X 11/16" X X X X X X 208-230-1-60 C O O O O O O 230-1-60 ELECTRICAL CHARACTERISTICS 208/230-3-60 UNIT SERIES E X = YES O = NO 25 1/8" 31 1/8" 37 3/16" 37 3/16" 43 3/16" 43 3/16" A AIR 7 1/2" AIR 36 15/16" 36 15/16" 44 9/16" 44 9/16" 44 9/16" 44 9/16" B DIMENSIONS -- ENGLISH 460-3-60 14 9/16" 14 9/16" 17 1/16" 17 1/16" 17 1/16" 17 1/16" C J N M 4 3/16" 2 1/2" VAPOR LINE CONN. K F 17 1/8" 23 1/8" 29 3/16" 29 3/16" 35 3/16" 35 3/16" G H 22" 28" 34 1/16" 34 1/16" 40 1/16" 40 1/16" FIELD CONTROL SUPPLY WIRE ENTRY 7/8" HOLE W/GROMMET 17 3/16" 17 3/16" 19 5/8" 19 5/8" 19 5/8" 19 5/8" FEMALE SWEAT CONN. P 23 7/16" 23 7/16" 30 1/2" 30 1/2" 30 1/2" 30 1/2" E 3/8" LIQUID LINE MALE FLARE CONN. 16" 16" 18 7/16" 18 7/16" 18 7/16" 18 7/16" D L 1" 13" 14" 13 11/16" 13 11/16" 14 1/2" 14 1/2" J 6 5/8" 6 3/4" 8 1/8" 8 1/8" 8 1/2" 8 1/2" K 11 1/4" 11 5/8" 15 7/8" 15 7/8" 18 7/8" 18 7/8" L 8" 4 1/2" 1 1/2" 6" 6" 6 1/2" 6 1/2" 6 1/2" 6 1/2" P 167 176 187 232 278 306 183 194 210 255 303 331 42 9/10" X 18" X 28 1/10" 42 9/10" X 18" X 34 1/10" 50 1/2" X 20 1/2" X 40 2/10" 50 1/2" X 20 1/2" X 40 2/10" 50 1/2" X 20 1/2" X 46 2/10" 50 1/2" X 20 1/2" X 46 2/10" OPERATING SHIPPING SHIPPING WEIGHT(lbs) WEIGHT(lbs) DIMENSIONS (L x W x H) 30,36,48,60 18,24 UNIT SIZE G H 1 7/16" 24" X 50" 23" X 42" MINIMUM MOUNTING PAD DIMENSIONS 5. ALL DIMENSIONS ARE IN "INCHES" UNLESS NOTED. 4. CENTER OF GRAVITY 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING F, MAX. 125 F. MODE IS 55 FIELD POWER SUPPLY CONN. HOLE SIZES PROVIDED: 7/8"-1/2"TRADE 1 3/16"-3/4"TRADE 1 3/8"-1"TRADE 1. REQUIRED CLEARANCES: WITH COIL FACING WALL; ALLOW 6" MIN CLEARANCE ON COIL SIDE AND COIL END AND 36" MIN CLEARANCE ON COMPRESSOR END AND FAN SIDE. WITH FAN FACING WALL; ALLOW 8" MIN CLEARANCE ON FAN SIDE AND COIL END AND 36" MIN CLEARANCE ON COMPRESSOR END AND COIL SIDE. WITH MULTI UNIT APPLICATION; ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER. 2 15/16" 2 15/16" 3 7/16" 3 7/16" 3 7/16" 3 7/16" N JUNCTION BOX FOR POWER SUPLLY AND CONTROL CONNECTIONS 5/8" 5/8" 3/4" 3/4" 7/8" 7/8" M 38QRR 9 38QRR018 38QRR024 38QRR030 38QRR036 38QRR048 38QRR060 A F 0 0 0 0 0 0 D 17.5 X X X X X X 208-230-1-60 C O O O O O O 230-1-60 O O O X X X O O O X X X ELECTRICAL CHARACTERISTICS 208/230-3-60 UNIT SERIES DIMENSIONS -- SI 460-3-60 B E AIR 190.5 AIR 938.2 938.2 1131.9 1131.9 1131.9 1131.9 638.2 790.6 944.6 944.6 1097.0 1097.0 X = YES O = NO B A 369.9 369.9 433.4 433.4 433.4 433.4 C J N 406.4 406.4 468.3 468.3 468.3 468.3 D VAPOR LINE CONN. 106.4 435.0 587.4 741.4 741.4 893.8 893.8 G H L 558.8 711.2 865.2 865.2 1017.6 1017.6 FIELD CONTROL SUPPLY WIRE ENTRY 22.22 HOLE W/GROMMET 436.6 436.6 498.5 498.5 498.5 498.5 F FEMALE SWEAT CONN. M K 63.5 9.53 LIQUID LINE MALE FLARE CONN. P 595.3 595.3 774.7 774.7 774.7 774.7 E 25.4 330.2 355.6 347.7 347.7 368.3 368.3 J 168.3 171.5 206.4 206.4 215.9 215.9 K 285.8 295.3 403.2 403.2 479.4 479.4 L 203.2 114.3 38.1 152.4 152.4 165.1 165.1 165.1 165.1 P 75.9 80.0 85.0 105.4 126.4 139.0 83.2 88.2 95.4 115.9 137.7 150.4 1090.2 X 457.7 X 714.3 1090.2 X 457.7 X 866.7 1282.7 X 520.7 X 1020.7 1282.7 X 520.7 X 1020.7 1282.7 X 520.7 X 1173.1 1282.7 X 520.7 X 1173.1 OPERATING SHIPPING SHIPPING WEIGHT(KG) WEIGHT(KG) DIMENSIONS (L x W x H) 30,36,48,60 18,24 UNIT SIZE 38QRR G H 36.5 609.6 X 1270.0 584.2 X 1066.8 MINIMUM MOUNTING PAD DIMENSIONS 5. ALL DIMENSIONS ARE IN "MM" UNLESS NOTED. 4. CENTER OF GRAVITY 3. SERIES DESIGNATION IS THE 13TH POSITION OF THE UNIT MODEL NUMBER. 2. MINIMUM OUTDOOR OPERATING AMBIENT IN COOLING MODE IS 12.8 C, MAX. 51.7 C. FIELD POWER SUPPLY CONN. HOLE SIZES PROVIDED: 22.22 - 12.70 TRADE 30.16 - 19.05 TRADE 34.92 - 25.40 TRADE 1. REQUIRED CLEARANCES: WITH COIL FACING WALL; ALLOW 152.4 MIN CLEARANCE ON COIL SIDE AND COIL END AND 914.4 MIN CLEARANCE ON COMPRESSOR END AND FAN SIDE. WITH FAN FACING WALL; ALLOW 203.2 MIN CLEARANCE ON FAN SIDE AND COIL END AND 914.4 MIN CLEARANCE ON COMPRESSOR END AND COIL SIDE. WITH MULTI UNIT APPLICATION; ARRANGE UNITS SO DISCHARGE OF ONE DOES NOT ENTER INLET OF ANOTHER. 74.6 74.6 87.3 87.3 87.3 87.3 N JUNCTION BOX FOR POWER SUPLLY AND CONTROL CONNECTIONS 15.9 15.9 19.0 19.0 22.2 22.2 M 10 BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH -10 (-23) 0.00 0 (17.78) 20 10 (-12.22) (-6.67) 30 (-1.11) 40 (4.44) OUTDOOR TEMPERATURE, ºF (ºC) 50 (10) 60 (15.56) 70 (21.11) 80 (26.67) 0.0 2.9 BASED ON INDOOR ENT. AIR AT 70ºF (21ºC) AND AT RATED CFM 10.00 8.8 11.7 5.9 38QRR018 FX4CNF018 38QRR024 FY4ANF030 38QRR030 FY4ANF030 20.00 30.00 40.00 14.6 38QRR036 FY4ANF036 50.00 20.5 23.4 17.6 38QRR048 FY4ANF048 38QRR060 FY4ANB060 60.00 70.00 80.00 38QRR BALANCE POINT WORKSHEET 38QRR kW TESTED AHRI COMBINATION RATINGS* Model Number Coil Model Number 38QRR018--- --- ---3 38QRR024--- --- ---3 38QRR030--- --- ---3 38QRR036--- --- ---3 38QRR036--- --- ---5 38QRR036--- --- ---6 38QRR048--- --- ---3 38QRR048--- --- ---5 38QRR048--- --- ---6 38QRR060--- --- ---3 38QRR060--- --- ---5 38QRR060--- --- ---6 FB4CNF018+TXV FY5BNF024+TXV FB4CNF030+TXV FY5BNF036+TXV FY5BNF036+TXV FY5BNF036+TXV FY5BNF048+TXV FY5BNF048+TXV FY5BNF048+TXV FY5BNB060 FY5BNB060 FY5BNB060 Furnace Model Number Cooling Capacity EER SEER 17,600 23,000 27,600 34,000 34,000 34,000 48,000 48,000 48,000 56,000 56,000 56,000 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 11.0 10.5 10.5 10.5 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 13.0 High Temp E E COP Capacity 18,000 3.60 23,800 3.86 28,400 3.92 34,000 3.72 34,000 3.72 34,000 3.72 47,000 3.78 47,000 3.78 47,000 3.78 57,000 3.58 57,000 3.58 57,000 3.58 HSPF 7.8 8.0 7.8 7.8 7.8 7.8 7.8 7.8 7.8 8.5 8.5 8.5 Low Temp H H COP Capacity 10,100 2.34 14,300 2.52 16,900 2.42 19,800 2.34 19,800 2.34 19,800 2.34 28,200 2.46 28,200 2.46 28,200 2.46 35,600 2.50 35,600 2.50 35,600 2.50 EER — Energy Efficiency Ratio SEER — Seasonal Energy Efficiency Ratio TXV — Thermostatic Expansion Valve NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included. 2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures. 3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature. 4. Do not apply with capillary tube coils as performance and reliability are significantly affected. 11 38QRR NOTE: Ratings contained in this document are subject to change at any time. For AHRI ratings certificates, please refer to the AHRI directory www.ahridirectory.org Additional ratings and system combinations can be accessed via the Carrier database at: http://cactaxcredits.info/carrier-ratings/ac_ratings_srch.php Equipment performance Calculator can be accessed at: http://rpmob.wrightsoft.com/ 12 19.83 21.81 18.14 18.44 20.24 22.25 18.75 18.82 20.55 22.58 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 22.45 23.21 25.40 27.81 23.31 23.67 25.84 28.28 24.01 24.08 26.17 28.64 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) Total 57 (13.9) See notes on pg. 14 900 800 700 CFM 75 (23.9) 11.55 14.63 18.64 18.75 11.07 13.84 16.55 18.14 10.56 13.02 15.46 17.41 Sens‡ 14.99 19.17 23.91 24.01 14.40 18.17 21.86 23.31 13.77 17.12 20.45 22.45 Sens‡ Capacity MBtuh† 18.03 62 (16.7) Total 17.41 EWB _F (_C) 75 (23.9) Capacity MBtuh† 57 (13.9) Evaporator Air 675 600 525 CFM EWB _F (_C) Evaporator Air 1.75 1.75 1.75 1.75 1.71 1.71 1.72 1.72 1.68 1.68 1.68 1.68 Total System KW** 1.24 1.27 1.28 1.28 1.23 1.25 1.27 1.27 1.21 1.23 1.25 1.26 Total System KW** 85 (29.4) 11.12 14.18 17.90 17.90 10.64 13.40 16.06 17.33 10.15 12.59 15.01 16.66 Sens‡ 27.08 24.75 22.93 22.93 26.78 24.47 22.45 22.28 26.37 24.08 22.01 21.50 Total 14.43 18.60 22.93 22.93 13.85 17.61 21.23 22.28 13.23 16.57 19.87 21.50 Sens‡ Capacity MBtuh† 21.34 19.41 17.90 17.90 21.05 19.14 17.47 17.33 20.67 18.78 17.08 16.66 Total Capacity MBtuh† 85 (29.4) DETAILED COOLING CAPACITIES 1.98 1.98 1.98 1.98 1.94 1.94 1.94 1.94 1.90 1.90 1.90 1.90 Total System KW** 1.43 1.45 1.46 1.46 1.41 1.43 1.45 1.45 1.40 1.42 1.43 1.44 Total System KW** 10.67 13.73 17.01 17.01 10.20 12.96 16.50 16.49 9.71 12.16 14.55 15.87 1.63 1.65 1.67 1.67 1.62 1.64 1.65 1.65 1.60 1.62 1.64 1.64 18.71 17.01 16.07 16.07 18.50 16.82 15.60 15.60 18.22 16.55 15.10 15.04 10.21 13.25 16.07 16.07 9.75 12.50 15.60 15.60 9.27 11.71 14.04 15.04 1.86 1.88 1.89 1.89 1.84 1.86 1.87 1.87 1.82 1.84 1.86 1.86 25.41 23.23 21.77 21.77 25.15 23.00 21.19 21.19 24.81 22.68 20.75 20.47 13.84 18.00 21.77 21.77 13.26 17.02 21.19 21.19 12.65 15.99 19.26 20.47 2.23 2.23 2.23 2.23 2.19 2.19 2.19 2.19 2.15 2.15 2.15 2.15 23.67 21.64 20.53 20.54 23.48 21.45 20.01 20.02 23.19 21.18 19.45 19.37 13.23 17.37 20.53 20.54 12.66 16.40 20.01 20.02 12.07 15.39 18.58 19.37 38QRR024 Outdoor Section With FY4ANF024 Indoor Section 2.50 2.50 2.50 2.50 2.46 2.46 2.46 2.46 2.42 2.43 2.43 2.43 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 20.05 18.23 17.01 17.01 19.80 18.00 16.50 16.49 19.47 17.69 16.10 15.87 38QRR018 Outdoor Section With FX4CNF018 Indoor Section CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 115 (46.1) 115 (46.1) 9.74 12.76 15.07 15.07 9.28 12.02 14.66 14.66 8.81 11.24 14.15 14.15 Sens‡ 21.81 19.95 19.18 19.19 21.66 19.80 18.73 18.74 21.44 19.59 18.17 18.17 Total 12.59 16.69 19.18 19.19 12.03 15.75 18.73 18.74 11.44 14.75 18.17 18.17 Sens‡ Capacity MBtuh† 17.30 15.74 15.07 15.07 17.13 15.57 14.66 14.66 16.90 15.35 14.15 14.15 Total Capacity MBtuh† 38QRR 2.79 2.79 2.80 2.80 2.76 2.76 2.76 2.76 2.72 2.72 2.72 2.72 Total System KW** 2.10 2.12 2.13 2.13 2.09 2.10 2.11 2.11 2.07 2.09 2.10 2.10 Total System KW** 125 (51.7) 125 (51.7) 9.23 12.23 13.97 13.97 8.78 11.51 13.61 13.62 8.32 10.74 13.17 13.18 Sens‡ 19.76 18.09 17.67 17.67 19.66 17.99 17.30 17.30 19.50 17.84 16.82 16.82 Total 11.89 15.95 17.67 17.67 11.33 15.03 17.30 17.30 10.76 14.06 16.82 16.82 Sens‡ Capacity MBtuh† 15.78 14.37 13.97 13.97 15.65 14.24 13.61 13.62 15.48 14.06 13.17 13.18 Total Capacity MBtuh† 3.11 3.11 3.11 3.11 3.07 3.07 3.08 3.08 3.03 3.04 3.04 3.04 Total System KW** 2.37 2.39 2.39 2.39 2.35 2.37 2.38 2.38 2.33 2.35 2.36 2.36 Total System KW** 13 30.16 33.26 27.74 27.99 30.68 33.84 28.58 28.60 31.08 34.29 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 32.85 33.74 37.12 40.95 34.07 34.43 37.75 41.65 35.07 35.09 38.24 42.20 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) Total 57 (13.9) See notes on pg. 14 1350 1200 1050 CFM 75 (23.9) 17.38 22.24 28.58 28.58 16.67 21.05 25.24 27.74 15.93 19.83 23.68 26.74 Sens‡ 22.28 28.52 35.09 35.07 21.38 27.01 32.41 34.07 20.46 25.47 30.42 32.85 Sens‡ Capacity MBtuh† 27.42 62 (16.7) Total 26.74 EWB _F (_C) 75 (23.9) Capacity MBtuh† 57 (13.9) Evaporator Air 1125 1000 875 CFM EWB _F (_C) Evaporator Air 2.54 2.54 2.54 2.54 2.48 2.48 2.48 2.48 2.41 2.41 2.42 2.42 Total System KW** 2.05 2.06 2.07 2.06 2.01 2.01 2.02 2.02 1.96 1.97 1.97 1.97 Total System KW** 85 (29.4) 16.80 21.64 27.39 27.40 16.10 20.47 26.64 26.61 15.37 19.26 23.06 25.68 Sens‡ 40.15 36.34 33.63 33.64 39.67 35.92 32.82 32.70 39.05 35.36 32.15 31.56 Total 21.54 27.76 33.63 33.64 20.66 26.27 32.51 32.70 19.75 24.74 29.63 31.56 Sens‡ Capacity MBtuh† 32.62 29.53 27.39 27.40 32.22 29.17 26.64 26.61 31.70 28.71 26.11 25.68 Total Capacity MBtuh† 85 (29.4) 2.83 2.83 2.83 2.83 2.77 2.77 2.77 2.77 2.70 2.70 2.71 2.71 Total System KW** 2.29 2.29 2.30 2.30 2.24 2.25 2.25 2.25 2.20 2.20 2.21 2.21 Total System KW** DETAILED COOLING CAPACITIES(CONT.) 16.21 21.03 26.15 26.15 15.52 19.87 25.42 25.43 14.80 18.67 22.39 24.55 2.55 2.55 2.56 2.56 2.50 2.51 2.51 2.51 2.46 2.46 2.47 2.47 29.02 26.21 24.82 24.82 28.73 25.94 24.16 24.16 28.33 25.59 23.37 23.36 15.59 20.38 24.82 24.82 14.91 19.24 24.16 24.16 14.20 18.05 23.37 23.36 2.84 2.84 2.85 2.85 2.79 2.80 2.80 2.80 2.75 2.75 2.76 2.76 38.01 34.37 32.12 32.12 37.60 34.00 31.25 31.25 37.05 33.51 30.50 30.20 20.79 26.97 32.12 32.12 19.91 25.50 31.25 31.25 19.01 23.98 28.77 30.20 3.15 3.15 3.16 3.16 3.09 3.09 3.09 3.09 3.02 3.03 3.03 3.03 35.76 32.29 30.50 30.51 35.41 31.98 29.71 29.71 34.93 31.56 28.76 28.74 38QRR036 Outdoor Section With FY4ANF036 Indoor Section 20.00 26.14 30.50 30.51 19.13 24.69 29.71 29.71 18.24 23.19 28.76 28.74 115 (46.1) 115 (46.1) 14.95 19.68 23.39 23.39 14.27 18.57 22.80 22.80 13.57 17.40 22.07 22.07 Sens‡ 33.34 30.07 28.76 28.76 33.06 29.81 28.04 28.05 32.66 29.46 27.16 27.17 Total 19.16 25.24 28.76 28.76 18.31 23.83 28.04 28.05 17.42 22.35 27.16 27.17 Sens‡ Capacity MBtuh† 27.04 24.39 23.39 23.40 26.80 24.17 22.80 22.80 26.47 23.87 22.07 22.07 Total Capacity MBtuh† 38QRR 3.51 3.51 3.51 3.51 3.45 3.45 3.45 3.45 3.38 3.38 3.39 3.39 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 30.87 27.91 26.15 26.15 30.52 27.60 25.42 25.43 30.06 27.19 24.75 24.55 38QRR030 Outdoor Section With FY4ANF030 Indoor Section CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 3.90 3.90 3.90 3.90 3.84 3.84 3.84 3.84 3.77 3.78 3.78 3.78 Total System KW** 3.16 3.16 3.16 3.16 3.11 3.12 3.12 3.12 3.07 3.07 3.07 3.07 Total System KW** 125 (51.7) 125 (51.7) 14.25 18.91 21.82 21.82 13.58 17.84 21.29 21.29 12.88 16.69 20.64 20.64 Sens‡ 30.71 27.67 26.84 26.84 30.49 27.46 26.20 26.21 30.18 27.18 25.42 25.42 Total 18.25 24.25 26.84 26.84 17.41 22.89 26.20 26.21 16.54 21.44 25.42 25.42 Sens‡ Capacity MBtuh† 24.89 22.43 21.82 21.82 24.70 22.25 21.29 21.29 24.44 22.01 20.64 20.64 Total Capacity MBtuh† 4.33 4.33 4.33 4.33 4.27 4.27 4.27 4.27 4.20 4.20 4.20 4.20 Total System KW** 3.50 3.51 3.51 3.51 3.46 3.46 3.47 3.47 3.41 3.42 3.42 3.42 Total System KW** 14 52.47 57.60 48.01 48.76 53.40 58.60 49.48 49.61 54.07 59.33 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 55.23 56.78 62.09 67.81 57.21 57.83 63.02 68.76 58.83 58.83 63.66 69.43 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 67 (19.4) 72 (22.2) Total 36.04 46.64 58.83 58.83 34.66 44.22 53.47 57.21 33.20 41.69 50.07 55.23 Sens‡ 4.33 4.30 4.27 4.27 4.21 4.18 4.15 4.15 4.09 4.06 4.03 4.02 Total System KW** 3.51 3.53 3.54 3.54 3.43 3.44 3.45 3.46 3.34 3.35 3.37 3.37 Total System KW** 85 (29.4) 29.62 38.18 47.44 47.44 28.43 36.15 43.60 46.08 27.18 34.03 40.81 44.43 Sens‡ 65.50 60.14 56.15 56.16 64.97 59.62 54.88 54.70 64.18 58.84 53.89 52.89 Total 34.67 45.25 56.15 56.16 33.31 42.87 54.40 54.70 31.87 40.36 48.69 52.89 Sens‡ Capacity MBtuh† 56.36 51.36 47.44 47.44 55.73 50.78 46.44 46.08 54.86 49.98 45.53 44.43 Total Capacity MBtuh† 85 (29.4) 4.76 4.73 4.71 4.71 4.64 4.61 4.59 4.59 4.52 4.49 4.47 4.46 Total System KW** 3.95 3.96 3.98 3.98 3.86 3.88 3.89 3.89 3.78 3.79 3.81 3.81 Total System KW** 28.50 37.05 45.25 45.26 27.33 35.04 44.03 44.02 26.10 32.94 39.65 42.50 4.43 4.45 4.46 4.46 4.35 4.36 4.38 4.38 4.26 4.28 4.29 4.29 49.76 45.40 42.88 42.88 49.35 45.01 41.77 41.77 48.75 44.44 40.62 40.40 27.31 35.84 42.88 42.88 26.16 33.86 41.77 41.77 24.95 31.78 38.37 40.40 4.96 4.98 4.99 4.99 4.88 4.90 4.91 4.91 4.79 4.81 4.82 4.83 61.30 56.40 53.29 53.29 60.91 56.00 52.00 52.01 60.30 55.38 50.86 50.39 33.21 43.79 53.29 53.29 31.87 41.44 52.00 52.01 30.47 38.97 47.21 50.39 5.23 5.21 5.19 5.19 5.11 5.09 5.07 5.07 5.00 4.97 4.95 4.94 56.88 52.44 50.18 50.18 56.61 52.16 49.08 49.09 56.16 51.69 47.70 47.68 38QRR060 Outdoor Section With FY4ANF060 Indoor Section 31.70 42.24 50.18 50.18 30.37 39.93 49.08 49.09 28.99 37.50 47.70 47.68 5.75 5.73 5.72 5.72 5.63 5.61 5.60 5.60 5.52 5.50 5.48 5.48 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 53.17 48.49 45.25 45.26 52.66 48.00 44.03 44.02 51.92 47.31 43.15 42.50 38QRR048 Outdoor Section With FY4ANF048 Indoor Section CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.6) Total Total Capacity MBtuh† Capacity MBtuh† System System Total Sens‡ Total Sens‡ KW** KW** 115 (46.1) 115 (46.1) 26.03 34.53 40.27 40.27 24.90 32.59 39.30 39.30 23.71 30.54 38.09 38.09 Sens‡ 52.11 48.21 46.76 46.77 52.03 48.03 45.87 45.87 51.73 47.71 44.70 44.70 Total 30.08 40.58 46.76 46.77 28.80 38.33 45.87 45.87 27.44 35.94 44.70 44.70 Sens‡ Capacity MBtuh† 46.04 42.07 40.27 40.27 45.75 41.77 39.30 39.30 45.28 41.33 38.09 38.09 Total Capacity MBtuh† 6.31 6.30 6.30 6.30 6.20 6.19 6.18 6.18 6.09 6.07 6.06 6.06 Total System KW** 5.54 5.56 5.57 5.57 5.46 5.48 5.49 5.49 5.37 5.39 5.41 5.41 Total System KW** 125 (51.7) 125 (51.7) 24.62 33.06 37.29 37.29 23.51 31.18 36.49 36.49 22.34 29.17 35.46 35.46 Sens‡ 46.77 43.52 42.85 42.85 46.83 43.46 42.20 42.20 46.71 43.29 41.27 41.27 Total 28.31 38.70 42.85 42.85 27.04 36.54 42.19 42.20 25.71 34.22 41.27 41.27 Sens‡ Capacity MBtuh† 41.89 38.37 37.29 37.29 41.71 38.17 36.49 36.49 41.40 37.84 35.46 35.46 Total Capacity MBtuh† 6.92 6.92 6.92 6.92 6.81 6.81 6.81 6.81 6.70 6.69 6.69 6.69 Total System KW** 6.16 6.19 6.20 6.20 6.08 6.10 6.11 6.11 5.99 6.02 6.03 6.03 Total System KW** * Tested combination. { Total and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80_F (27_C) entering air at the indoor coil. For sensible capacities at other than 80_F (27_C), deduct 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F (27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F (27_C). ** System kw is total of indoor and outdoor unit kilowatts. EWB — Entering Wet Bulb NOTES: 1. Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per AHRI standard 210/240 ---2008. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur. 2. When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. 2250 2000 1750 CFM 75 (23.9) 30.67 39.26 49.28 49.48 29.47 37.21 44.78 48.01 28.20 35.06 41.89 46.23 Sens‡ Capacity MBtuh† 47.80 62 (16.7) Total 46.23 EWB _F (_C) 75 (23.9) Capacity MBtuh† 57 (13.9) Evaporator Air 1800 1600 1400 CFM EWB _F (_C) Evaporator Air DETAILED COOLING CAPACITIES (CONT.) 38QRR 15 6.35 6.45 5.94 6.06 6.16 5.63 5.75 5.85 600 675 525 600 675 525 600 675 9.57 9.77 9.95 9.18 9.40 9.58 8.77 8.97 9.16 800 900 700 800 900 700 800 900 Total 700 CFM -- 3 ( -- 19.4) 5.39 5.29 5.18 5.67 5.57 5.47 5.94 5.84 5.73 Integ* 8.42 8.25 8.07 8.81 8.64 8.44 9.16 8.99 8.81 Integ* Capacity MBtuh 6.23 Total See notes on pg. 17 75 (23.4) 70 (21.1) 65 (18.3) EDB _F (_C) -- 3 ( -- 19.4) Capacity MBtuh 525 CFM INDOOR AIR 75 (23.4) 70 (21.1) 65 (18.3) EDB _F (_C) INDOOR AIR 1.80 1.77 1.75 1.72 1.69 1.67 1.64 1.61 1.60 Total Sys. KW† 1.25 1.24 1.23 1.19 1.18 1.18 1.14 1.13 1.13 Total Sys. KW† 7 ( -- 13.9) 7.22 7.11 6.99 7.47 7.36 7.24 7.71 7.61 7.49 Integ* 11.79 11.59 11.37 12.15 11.96 11.73 12.48 12.29 12.07 Total 10.84 10.65 10.45 11.17 10.99 10.78 11.47 11.29 11.10 Integ* Capacity MBtuh 7.86 7.74 7.61 8.12 8.01 7.88 8.38 8.28 8.15 Total Capacity MBtuh 7 ( -- 13.9) 1.84 1.82 1.81 1.75 1.73 1.72 1.66 1.65 1.64 Total Sys. KW† 1.30 1.29 1.29 1.24 1.23 1.23 1.18 1.17 1.17 Total Sys. KW† 17 ( -- 8.3) 9.09 8.97 8.84 9.33 9.21 9.08 9.57 9.44 9.30 Integ* 14.50 14.26 14.02 14.81 14.60 14.38 15.13 14.92 14.70 Total 13.22 13.00 12.79 13.50 13.31 13.11 13.79 13.60 13.41 Integ* Capacity MBtuh 9.97 9.84 9.69 10.23 10.10 9.95 10.50 10.36 10.20 Total Capacity MBtuh 17 ( -- 8.3) HEAT PUMP HEATING PERFORMANCE 27 ( -- 2.8) Total Integ* Capacity MBtuh Total Sys. KW† 37 (2.8) Total Integ* Capacity MBtuh 1.87 1.86 1.86 1.78 1.77 1.76 1.68 1.67 1.67 Total Sys. KW† 1.34 1.34 1.35 1.27 1.28 1.28 1.21 1.21 1.22 10.92 10.77 10.60 11.19 11.04 10.87 11.45 11.31 11.14 1.39 1.39 1.41 1.32 1.32 1.34 1.25 1.25 1.27 14.95 14.77 14.55 15.26 15.08 14.86 15.59 15.39 15.17 13.60 13.44 13.24 13.89 13.72 13.52 14.18 14.01 13.81 1.45 1.46 1.48 1.37 1.39 1.41 1.30 1.31 1.33 Total Sys. KW† 37 (2.8) 17.35 17.10 16.84 17.65 17.43 17.18 17.94 17.73 17.48 15.41 15.19 14.96 15.68 15.48 15.26 15.94 15.75 15.53 1.90 1.90 1.91 1.80 1.80 1.81 1.71 1.71 1.71 20.37 20.23 19.84 20.75 20.48 20.17 21.14 20.86 20.55 18.54 18.41 18.06 18.89 18.64 18.35 19.23 18.99 18.70 1.94 1.95 1.97 1.84 1.85 1.86 1.74 1.75 1.77 Total Total Capacity MBtuh Sys. Sys. Total Integ* Total Integ* KW† KW† 38QRR024 Outdoor Section With FY4ANF024 Indoor Section Capacity MBtuh 27 ( -- 2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 12.29 12.13 11.94 12.59 12.43 12.24 12.89 12.73 12.54 38QRR018 Outdoor Section With FX4CNF018 Indoor Section Total Sys. KW† OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 47 (8.3) 47 (8.3) 17.86 17.65 17.39 18.19 18.00 17.74 18.56 18.35 18.09 Integ* 23.89 23.59 23.24 24.31 24.00 23.64 24.73 24.42 24.05 Integ* 38QRR 23.89 23.59 23.24 24.31 24.00 23.64 24.73 24.42 24.05 Total Capacity MBtuh 17.86 17.65 17.39 18.19 18.00 17.74 18.56 18.35 18.09 Total Capacity MBtuh 2.00 2.01 2.04 1.90 1.91 1.94 1.80 1.81 1.84 Total Sys. KW† 1.52 1.54 1.57 1.45 1.46 1.49 1.38 1.39 1.42 Total Sys. KW† 57 (13.9) 57 (13.9) 21.06 20.85 20.54 21.41 21.23 20.95 21.73 21.60 21.35 Integ* 27.88 27.51 27.07 28.37 28.00 27.55 28.85 28.50 28.04 Total 27.88 27.51 27.07 28.37 28.00 27.55 28.85 28.50 28.04 Integ* Capacity MBtuh 21.06 20.85 20.54 21.41 21.23 20.95 21.73 21.60 21.35 Total Capacity MBtuh 2.08 2.10 2.14 1.97 1.99 2.03 1.87 1.89 1.93 Total Sys. KW† 1.61 1.65 1.68 1.52 1.55 1.60 1.45 1.47 1.52 Total Sys. KW† 67 (19.4) 67 (19.4) 24.58 24.44 24.18 24.89 24.80 24.58 25.15 25.12 24.96 Integ* 32.37 32.01 31.49 32.79 32.52 32.04 33.18 32.95 32.57 Total 32.37 32.01 31.49 32.79 32.52 32.04 33.18 32.95 32.57 Integ* Capacity MBtuh 24.58 24.44 24.18 24.89 24.80 24.58 25.15 25.12 24.96 Total Capacity MBtuh 2.14 2.18 2.26 2.03 2.07 2.13 1.93 1.96 2.01 Total Sys. KW† 1.71 1.74 1.79 1.63 1.65 1.70 1.55 1.57 1.61 Total Sys. KW† 16 11.60 11.83 10.86 11.11 11.35 10.33 10.58 10.82 1000 1125 875 1000 1125 875 1000 1125 12.91 13.20 13.45 12.29 12.61 12.90 11.65 11.98 12.27 1200 1350 1050 1200 1350 1050 1200 1350 2.32 2.29 2.26 2.23 2.20 2.17 2.14 2.11 2.08 11.29 11.02 10.72 11.87 11.60 11.30 12.37 12.14 11.88 Integ* 2.67 2.63 2.59 2.56 2.52 2.48 2.45 2.41 2.38 Total Sys. KW† Total Sys. KW† -- 3 ( -- 19.4) 9.96 9.74 9.51 10.44 10.22 9.99 10.89 10.68 10.44 Integ* Capacity MBtuh 1050 CFM Total 11.35 Total See notes on pg. 17 75 (23.4) 70 (21.1) 65 (18.3) EDB _F (_C) -- 3 ( -- 19.4) Capacity MBtuh 875 CFM INDOOR AIR 75 (23.4) 70 (21.1) 65 (18.3) EDB _F (_C) INDOOR AIR 7 ( -- 13.9) 12.82 12.59 12.34 13.26 13.04 12.78 13.67 13.44 13.20 Integ* 15.99 15.67 15.30 16.70 16.34 15.93 17.12 16.82 16.52 Total 14.69 14.40 14.06 15.34 15.01 14.64 15.73 15.45 15.18 Integ* Capacity MBtuh 13.95 13.71 13.43 14.43 14.19 13.91 14.87 14.63 14.36 Total Capacity MBtuh 7 ( -- 13.9) 2.72 2.69 2.66 2.61 2.57 2.54 2.49 2.45 2.43 Total Sys. KW† 2.32 2.30 2.28 2.22 2.20 2.18 2.13 2.10 2.09 Total Sys. KW† 17 ( -- 8.3) 15.69 15.46 15.18 16.09 15.86 15.59 16.48 16.25 15.97 Integ* 19.98 19.63 19.23 20.55 20.20 19.80 21.09 20.74 20.35 Total 18.22 17.89 17.53 18.74 18.42 18.05 19.22 18.91 18.56 Integ* Capacity MBtuh 17.21 16.96 16.65 17.65 17.40 17.10 18.08 17.82 17.52 Total Capacity MBtuh 17 ( -- 8.3) 2.77 2.74 2.73 2.64 2.62 2.60 2.52 2.50 2.48 Total Sys. KW† 2.32 2.30 2.29 2.21 2.20 2.19 2.11 2.10 2.09 Total Sys. KW† 27 ( -- 2.8) Integ* 37 (2.8) Total Integ* Capacity MBtuh 2.31 2.30 2.31 2.20 2.20 2.20 2.10 2.09 2.10 24.31 23.99 23.64 24.77 24.44 24.07 25.25 24.90 24.53 22.12 21.83 21.51 22.54 22.24 21.90 22.98 22.66 22.32 2.31 2.31 2.33 2.20 2.20 2.22 2.10 2.10 2.11 Total Sys. KW† 37 (2.8) 24.33 23.95 23.51 24.89 24.51 24.08 25.41 25.03 24.61 21.61 21.27 20.88 22.10 21.76 21.39 22.57 22.23 21.86 2.81 2.80 2.80 2.68 2.67 2.67 2.56 2.54 2.54 29.05 28.63 28.15 29.60 29.19 28.71 30.14 29.72 29.25 26.44 26.06 25.62 26.93 26.56 26.13 27.42 27.05 26.61 2.87 2.86 2.88 2.73 2.73 2.74 2.60 2.60 2.61 Total Total Capacity MBtuh Sys. Sys. Total Integ* Total Integ* KW† KW† 38QRR036 Outdoor Section With FY4ANF036 Indoor Section 27 ( -- 2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 18.37 18.09 17.81 18.73 18.49 18.20 19.09 18.84 18.57 Capacity MBtuh 20.68 20.37 20.05 21.08 20.82 20.49 21.49 21.21 20.91 38QRR030 Outdoor Section With FY4ANF030 Indoor Section Total Total Sys. KW† OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) Capacity MBtuh HEAT PUMP HEATING PERFORMANCE (CONT.) 47 (8.3) 28.47 28.10 27.58 28.97 28.60 28.17 29.48 29.11 28.67 Integ* 34.24 33.74 33.19 34.90 34.40 33.81 35.63 35.14 34.46 Total 34.24 33.74 33.19 34.90 34.40 33.81 35.63 35.14 34.46 Integ* Capacity MBtuh 28.47 28.10 27.58 28.97 28.60 28.17 29.48 29.11 28.67 Total Capacity MBtuh 47 (8.3) 38QRR 2.93 2.94 2.96 2.79 2.80 2.82 2.67 2.67 2.69 Total Sys. KW† 2.33 2.34 2.36 2.22 2.23 2.25 2.12 2.12 2.15 Total Sys. KW† 57 (13.9) 57 (13.9) 32.94 32.51 31.99 33.50 33.08 32.56 34.09 33.65 33.12 Integ* 40.25 39.69 39.02 40.96 40.39 39.71 41.66 41.10 40.41 Total 40.25 39.69 39.02 40.96 40.39 39.71 41.66 41.10 40.41 Integ* Capacity MBtuh 32.94 32.51 31.99 33.50 33.08 32.56 34.09 33.65 33.12 Total Capacity MBtuh 3.02 3.04 3.08 2.88 2.90 2.94 2.75 2.76 2.80 Total Sys. KW† 2.35 2.37 2.40 2.25 2.26 2.29 2.15 2.16 2.19 Total Sys. KW† 67 (19.4) 67 (19.4) 37.88 37.38 36.77 38.53 38.03 37.41 39.18 38.68 38.07 Integ* 46.83 46.17 45.37 47.62 46.97 46.15 48.48 47.76 46.94 Total 46.83 46.17 45.37 47.62 46.97 46.15 48.48 47.76 46.94 Integ* Capacity MBtuh 37.88 37.38 36.77 38.53 38.03 37.41 39.18 38.68 38.07 Total Capacity MBtuh 3.13 3.16 3.22 2.98 3.01 3.07 2.85 2.88 2.93 Total Sys. KW† 2.39 2.42 2.46 2.29 2.31 2.35 2.19 2.21 2.25 Total Sys. KW† 17 19.41 17.79 18.24 18.65 16.95 17.40 17.81 1800 1400 1600 1800 1400 1600 1800 -- 3 ( -- 19.4) 16.39 16.01 15.59 17.16 16.78 16.36 17.86 17.46 17.06 Integ* 23.58 24.18 24.74 22.60 23.20 23.76 21.54 22.14 22.69 1750 2000 2250 1750 2000 2250 1750 2000 2250 Total 20.88 20.37 19.81 21.86 21.34 20.79 22.76 22.24 21.70 Integ* Capacity MBtuh 18.98 1600 CFM 18.54 Total Capacity MBtuh 1400 CFM 3.55 3.49 3.44 3.41 3.35 3.30 3.26 3.20 3.16 Total Sys. KW† 4.13 4.04 3.96 3.98 3.89 3.81 3.82 3.73 3.66 Total Sys. KW† -- 3 ( -- 19.4) 7 ( -- 13.9) 21.16 20.76 20.31 21.84 21.45 21.00 22.47 22.06 21.63 Integ* 28.93 28.35 27.71 29.82 29.26 28.66 30.70 30.13 29.51 Total 26.58 26.05 25.47 27.41 26.89 26.33 28.21 27.69 27.12 Integ* Capacity MBtuh 23.03 22.59 22.10 23.77 23.34 22.85 24.45 24.01 23.54 Total Capacity MBtuh 7 ( -- 13.9) 4.28 4.21 4.14 4.11 4.03 3.97 3.94 3.86 3.80 Total Sys. KW† 3.66 3.61 3.58 3.50 3.45 3.42 3.33 3.29 3.26 Total Sys. KW† 17 ( -- 8.3) 26.05 25.64 25.15 26.68 26.26 25.79 27.24 26.83 26.37 Integ* 35.36 34.75 34.08 36.20 35.60 34.94 37.00 36.40 35.74 Total 32.24 31.69 31.07 33.01 32.46 31.85 33.73 33.19 32.59 Integ* Capacity MBtuh 28.57 28.12 27.58 29.26 28.80 28.29 29.87 29.43 28.92 Total Capacity MBtuh 17 ( -- 8.3) 4.42 4.36 4.32 4.23 4.17 4.12 4.05 3.99 3.94 Total Sys. KW† 3.75 3.72 3.71 3.57 3.54 3.53 3.40 3.37 3.36 Total Sys. KW† Integ* Total Sys. KW† 37 (2.8) Total Integ* Capacity MBtuh 30.69 30.25 29.75 31.24 30.82 30.33 31.76 31.34 30.86 3.85 3.83 3.84 3.66 3.64 3.65 3.47 3.46 3.46 40.95 40.43 39.82 41.56 41.04 40.45 42.14 41.63 41.04 37.27 36.79 36.24 37.82 37.35 36.81 38.35 37.88 37.35 3.95 3.95 3.98 3.74 3.75 3.77 3.55 3.55 3.57 Total Sys. KW† 37 (2.8) 42.10 41.46 40.75 42.87 42.25 41.55 43.61 42.98 42.30 37.39 36.82 36.19 38.08 37.52 36.90 38.73 38.18 37.57 4.57 4.52 4.49 4.37 4.32 4.29 4.18 4.13 4.10 49.15 48.46 47.94 49.96 49.28 48.50 50.76 50.08 49.30 44.73 44.10 43.63 45.47 44.84 44.13 46.19 45.57 44.86 4.73 4.70 4.70 4.52 4.48 4.47 4.31 4.28 4.27 Total Total Capacity MBtuh Sys. Sys. Total Integ* Total Integ* KW† KW† 38QRR060 Outdoor Section With FY4ANF060 Indoor Section Capacity MBtuh 27 ( -- 2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 34.55 34.06 33.49 35.18 34.70 34.15 35.76 35.28 34.75 38QRR048 Outdoor Section With FY4ANF048 Indoor Section Total Capacity MBtuh 27 ( -- 2.8) OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 47 (8.3) 47 (8.3) 47.90 47.31 46.65 48.64 48.00 47.29 49.54 48.90 48.01 Integ* 56.90 56.15 55.26 57.78 57.00 56.14 58.77 57.95 57.00 Total 56.90 56.15 55.26 57.78 57.00 56.14 58.77 57.95 57.00 Integ* Capacity MBtuh 47.90 47.31 46.65 48.64 48.00 47.29 49.54 48.90 48.01 Total Capacity MBtuh 4.90 4.89 4.91 4.68 4.66 4.68 4.47 4.45 4.46 Total Sys. KW† 4.05 4.07 4.13 3.85 3.86 3.91 3.65 3.67 3.71 Total Sys. KW† 57 (13.9) 57 (13.9) 56.36 55.58 54.69 57.27 56.49 55.57 58.20 57.41 56.46 Integ* 66.07 65.15 64.10 67.18 66.23 65.14 68.32 67.33 66.22 Total 66.07 65.15 64.10 67.18 66.23 65.14 68.32 67.33 66.22 Integ* Capacity MBtuh 56.36 55.58 54.69 57.27 56.49 55.57 58.20 57.41 56.46 Total Capacity MBtuh 5.13 5.14 5.18 4.90 4.90 4.94 4.69 4.68 4.71 Total Sys. KW† 4.21 4.25 4.32 3.99 4.03 4.10 3.79 3.82 3.89 Total Sys. KW† 67 (19.4) 67 (19.4) 66.14 65.19 64.05 67.24 66.28 65.13 68.36 67.39 66.21 Integ* 76.45 75.54 74.23 77.49 76.69 75.49 78.45 77.76 76.76 Total 76.45 75.54 74.23 77.49 76.69 75.49 78.45 77.76 76.76 Integ* Capacity MBtuh 66.14 65.19 64.05 67.24 66.28 65.13 68.36 67.39 66.21 Total Capacity MBtuh 5.33 5.38 5.47 5.09 5.12 5.21 4.86 4.88 4.96 Total Sys. KW† 4.40 4.46 4.56 4.18 4.23 4.33 3.97 4.02 4.11 Total Sys. KW† 38QRR { The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts. }The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity. NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice. EDB — Entering Dry Bulb 75 (23.4) 70 (21.1) 65 (18.3) EDB _F (_C) INDOOR AIR 75 (23.4) 70 (21.1) 65 (18.3) EDB _F (_C) INDOOR AIR HEAT PUMP HEATING PERFORMANCE (CONT.) 38QRR GUIDE SPECIFICATIONS GENERAL System Description Outdoor--mounted, air--cooled, split--system heat pump unit suitable for ground or rooftop installation. Unit consists of a scroll--type hermetic compressor, an air--cooled coil, propeller--type condenser fan, and a control box. Unit will discharge supply air horizontally as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or furnace. Quality Assurance — Unit will be rated in accordance with the latest edition of AHRI Standard 210. — Unit will be certified for capacity and efficiency, and listed in the latest AHRI directory. — Unit construction will comply with latest edition of ANSI/ ASHRAE and with NEC. — Unit will be constructed in accordance with UL standards and will carry the UL label of approval. Unit will have c--UL approval. — Unit cabinet will be capable of withstanding Federal Test Method Standard No. 141 (Method 6061) 500--hr salt spray test. — Air--cooled condenser coils will be leak tested and pressure tested — Unit constructed in ISO9001 approved facility. Delivery, Storage, and Handling — Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations. Warranty (for inclusion by specifying engineer) — U.S. and Canada only. PRODUCTS Equipment — Factory assembled, single piece, air--cooled heat pump unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R--410A), and special features required prior to field start--up. Unit Cabinet — Unit cabinet will be constructed of galvanized steel, bonderized, and coated with a powder coat paint. Fans — Condenser fan will be direct--drive propeller type, discharging air horizontally. Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 AIR--COOLED, SPLIT--SYSTEM HEAT PUMP 38QRR 1--1/2 TO 5 NOMINAL TONS — Condenser fan motors will be totally enclosed, 1--phase type with class B insulation and permanently lubricated bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated steel wire safety guards. Compressor — Compressor will be a scroll--type, hermetically sealed. — Compressor will be mounted on rubber vibration isolators. Condenser Coil — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed. Refrigeration Components — Refrigeration circuit components will include liquid--line front--seating shutoff valve with sweat connections, vapor--line front--seating shutoff valve with sweat connections, system charge of Puronr (R--410A) refrigerant, and compressor oil. — Unit will be equipped with high--pressure switch, low pressure switch and filter drier for Puron refrigerant. Operating Characteristics — The capacity of the unit will meet or exceed _____ Btuh at a suction temperature of _____ _F/_C. The power consumption at full load will not exceed _____ kW. — Combination of the unit and the evaporator or fan coil unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F/_C wet bulb and _____ _F/_C dry bulb, and air entering the unit at _____ _F/_C. — The system will have a SEER of _____ Btuh/watt or greater at DOE conditions. Electrical Requirements — Nominal unit electrical characteristics will be _____ v, single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Nominal unit electrical characteristics will be _____ v, three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v. Special Features — Refer to section of this literature identifying accessories and descriptions for specific features and available enhancements. Edition Date: 09/12 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 18 Catalog No: 38QRR ---7PD Replaces: 38QRR--- 6PD
© Copyright 2025 ExpyDoc