ISSUE 9 2014 Design Manual For Engineers The details and information in this book are for guidance of the erection of panels and flooring only. They are not site specific. Refer to the relevant panel drawings for the site, which should be read in conjunction with the approved Building Regulation drawings and must be adhered to and take priority over standard details. For sundry items refer to Sips Eco Panels manual Sips Eco Panels Design Manual For Engineers CONTENTS DM111 SOLEPLATE FIXING DETAILS DM211 SIPS TO SIPS FIXING DM215 EXTERNAL WALL CONNECTION DETAIL DM311 FIRST FLOOR SOLEPLATE FIXING DETAIL DM510 ROOF PANEL FIXING DM511 EAVES DETAIL DM512 RIDGE DETAILS 2014 ISSUE 9 THIS MANUAL IS FOR GUIDANCE ONLY. IT IS NOT SITE SPECIFIC. YOU MUST REFER TO THE DRAWINGS PROVIDED WITH EACH KIT FOR DETAILS RELEVANT TO THE SITE YOU ARE WORKING ON. SHOULD A DETAIL DIFFER TO SITE DRAWINGS - SITE DRAWINGS WOULD USUALLY TAKE PREFERENCE. IF YOU HAVE ANY QUESTIONS PLEASE CONTACT OUR CONTRACTS MANAGER IN THE FIRST INSTANCE ON 01787 377 388 OR THE PROJECT MANAGER. CONTENTS M10 M8 M10 Nylon frame fixings x 100mm at 440mm c/c for fixing 45mm soleplate to concrete slab. M8 Nylon frame fixings x 60mm at 440mm c/c for fixing 20mm soleplate to concrete slab. EXTERNAL WALL UPSTAND 7N/mm2 Dense Concrete Blocks, Density 1950kg/m3 x width of panel over, on 15mm Mortar bedding forming upstand. Concrete upstand can also be used with a GEN1 mix. THIS DRAWING IS NOT SITE SPECIFIC. REFER TO RELEVANT DRAWINGS PERTAINING TO THE PROJECT YOU ARE WORKING ON. INTERNAL UPSTAND 7N/mm2 Dense Concrete Blocks, Density 1950kg/m3 x width of panel over, on 15mm Mortar bedding forming upstand. Concrete upstand can also be used with a GEN1 mix.' Sips Eco Panel D.P.C. TREATED SOLEPLATE 20mm x 95mm TREATED SOLEPLATE MIN.150 F.F.L. GROUND LEVEL INTERNAL PARTITION F.F.L. SCREED/FLOORING SCREED/FLOORING INSULATION INSULATION CONCRETE SLAB DPM DPM CONCRETE SLAB D.P.C. D.P.C. HOLDING DOWN STRAPS FIXING OF SOLEPLATES Austenitic stainless steel holding down straps attached to SIP panels by 6 no. 3.35mm x 50mm stainless steel annular ring shank nails at corners, sides of openings and at 1200mm max. c/c and set into lean mix concrete where possible. Where practical, straps to be fixed to studs. Similar approved by supplier may be used. 20mm x SIP wall thickness or 95mm fixed with nylon frame fixings M8 x 60 at 440mm centres 45mm x 95mm base rail from panel is then located centrally on soleplates and nailed with 65mm galvanised nails at 600mm centres. Rebated panel is seated over 45mm insert timber and screwed through OSB from both faces horizontally into 45mm insert timber with 3.5mm x 35mm screws at 200mm centres SCREW 41 PAS 90 90mm Paslode nails used to fix internal studs to internal studs and 45mm baserail to soleplates at 600mm c/c. 3.5mm x 35mm grey phosphate at 200mm c/c and 50mm in from end. 2014 ISSUE 9 This drawing is not site specific. Work to written dimensions only. DO NOT SCALE. If in doubt ask. DM111 D.P.C. SOLEPLATE FIXINGS SPLINES AND RAILS FITTED INTO 45mm DEEP REBATES AROUND EDGE OF PANELS AND SCREWED AT 200mm c/c TOP PLATE SHOULD LAPS BE NECESSARY UPPER LAYERS SHOULD BE LAPPED HORIZONTALLY OVER LOWER LAYERS BY AT LEAST 100mm AND STAGGERED. THE SHEETS SHOULD BE LAPPED AT LEAST 150mm VERTICALLY. SCREW 41 3.5mm x 35mm grey phosphate at 200mm c/c and 50mm in from end. BOTTOM PLATE SIP PANEL SIP PANEL SIP PANEL INSULATED SPLINE SIP PANEL FIXING PROCEDURE GLIDEVALE PROTECT TF200 OR SIMILAR REFLECTIVE BREATHER MEMBRANE IS FITTED TO ALL WALLS AND RUBEROID - PRO BREATHER MEMBRANE TO ROOFS ON COMPLETION OF THE FRAME ERECTION. IT SHOULD BE FITTED STRICTLY IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. BELOW IS A BRIEF INSTALLATION GUIDE. THE REFLECTIVE MEMBRANE SHOULD BE FITTED WITH THE SILVER SIDE FACING OUT AND IN SUCH A WAY AS TO SHED WATER AWAY FROM THE SHEATHING AND BELOW THE LOWEST TIMBER. UPPER LAYERS SHOULD BE LAPPED HORIZONTALLY OVER LOWER LAYERS BY AT LEAST 100mm AND STAGGERED. THE SHEETS SHOULD BE LAPPED AT LEAST 150mm VERTICALLY. NAILS SHOULD BE GALVANISED, SHERADIZES OR AUSTENITIC STAINLESS STEEL, PHOSPHOR BRONZE OR SILICON BRONZE AND STAPLES SHOULD BE OF AUSTENITIC STAINLESS STEEL. TO PREVENT DAMAGE BY WIND, FIXINGS SHOULD BE AT REGULAR INTERVALS OF NO MORE THAN 500mm c/c. IT IS ESSENTIAL THAT THE LOWEST TIMBERS IN THE WALL ARE PROTECTED BY THE BREATHABLE MEMBRANE. IF GAPS ARE EVIDENT IN ROOF PANELS THESE SHOULD BE FILLED WITH INTUMESCENT FOAM PROVIDED. 2014 ISSUE 9 DM211 This drawing is not site specific. Work to written dimensions only. DO NOT SCALE. If in doubt ask. SIPS TO SIPS PANEL FIXING BRICKWORK SCREW 150 150 HeadLok screws used for fixing SIPs wall panels to SIPs wall panels at 400mm c/c and 100mm in from end. OR Simpson Strong Tie washer head screw Code: ESCR8.0x160 SIP PANEL BRICKWORK EXTERNAL CORNER SIP PANEL INTERNAL PARTITION T JUNCTION SIP / INTERNAL PARTITION 2014 ISSUE 9 DM215 This drawing is not site specific. Work to written dimensions only. DO NOT SCALE. If in doubt ask. EXTERNAL WALL DETAILS SCREW 51 PAS 90 @ 300mm c/c INTO RIM BEAM 3.9mm x 65mm grey phosphate at 300mm c/c for fixing flooring to joists all around the perimeter. FIRST FLOOR SIP PANELS SIT ONTO FLOORING 22 1ST FLOOR JOIST SCREW 41 AT 200mm c/c SCREW 41 3.5mm x 35mm grey phosphate at 200mm c/c and 50mm in from end. PAS 90 90mm Paslode nails used to SIPs panel base rail to floor deck at 600mm c/c PAS 51 51mm Paslode nails used to fix internal soleplates to floor deck at 600mm c/c FIRST FLOOR LOAD BEARING INT PANELS SIT ONTO 20mm x 95mm PLATE ON FLOORING FIRST FLOOR NON LOAD BEARING INT PANELS SIT ONTO 20mm x 95mm PLATE ON FLOORING 51mm nails at 600mm centres 50 90mm nails at 600mm centres 95mm x 38 min noggin Double joist at 600mm centres FLOOR ZONE Headbinders nailed to panels at 300mm centres Double joist or nogging nailed to headbinder at 600mm centres 2014 ISSUE 9 DM311 This drawing is not site specific. Work to written dimensions only. DO NOT SCALE. If in doubt ask. FIRST FLOOR SOLEPLATE DETAIL T ROOF PANEL FIXED DOWN WITH HEADLOK SCREW 250 AT 400mm c/c PAS 51 51mm Paslode nails at 600mm c/c used to fix plasterboard wedges. SCREW 250 PAS 90 90mm Paslode nails 250mm x 6mm HeadLok screws used for fixing roof panels to wall panels. Fixed at 400mm c/c and 100mm in from end. OR Simpson Strong Tie washer head screw Code: ESCR8.0x260 2014 ISSUE 9 DM510 This drawing is not site specific. Work to written dimensions only. DO NOT SCALE. If in doubt ask. ROOF PANEL FIXING TF1960 TF1930 ROOF PANEL FIXED DOWN WITH HEADLOK SCREW 250 AT 400mm c/c TIMBER WEDGE FIXED WITH HEADLOK SCREWS 100 AT 400mm c/c 20mm HEADBINDER FIXED HEADLOK SCREWS 100 AT 400mm c/c SIP PANEL TYPICAL EAVES (NO CEILING) ROOF PANEL FIXED DOWN WITH HEADLOK SCREW 250 AT 400mm c/c els to 00c/c IF PARTITION IS FITTED WITH FRAME BY ERECTORS A 400mm STRIP OF VCL MUST BE FITTED BEFORE THE PARTITION IS CONNECTED. TIMBER WEDGE FIXED WITH HEADLOK SCREWS 100 AT 400mm c/c ROOF PANEL FIXED DOWN WITH HEADLOK SCREW 250 AT 400mm c/c 20mm x 95mm HEADBINDER FIXED HEADLOK SCREWS 100 AT 400mm c/c 45mm x 95mm PARTITION TIMBER WEDGE FIXED WITH HEADLOK SCREWS 100 AT 400mm c/c TYPICAL EAVES (ATTIC ROOM) SCREW 250 PAS 51 PAS 90 51mm Paslode nails used to fix top plates to top rails at 600mm c/c. 90mm Paslode nails 2014 ISSUE 9 DM511 This drawing is not site specific. Work to written dimensions only. DO NOT SCALE. If in doubt ask. EAVES DETAILS 250 x 6mm HeadLok screws used for fixing roof panels to wall panels. Fixed at 400mm c/c and 100mm in from end. OR Simpson Strong Tie washer head screw Code: ESCR8.0x260 TIMBER WEDGE FIXED WITH HEADLOK SCREW 250 AT 400mm c/c ALTERNATELY AND IN PAIRS AT EACH BUTT JOINT ROOF PANEL FIXED DOWN WITH HEADLOK SCREW 250 AT 400mm c/c TIMBER WEDGE FIXED WITH HEADLOK SCREW 100 AT 400mm c/c 45mm x 120mm CEILING JOISTS ON MIDI HANGERS ONTO WEDGE TIMBER WEDGE SECURED WITH HEADLOK SCREW 250 AT 400mm c/c IF PARTITION IS FITTED WITH FRAME BY ERECTORS A 400mm STRIP OF VCL MUST BE FITTED BEFORE THE PARTITION IS CONNECTED . RIDGE BEAM FIXED CENTRALLY WITH HEADLOK SCREWS 150 AT 600mm c/c FIXED FROM ALTERNATE SIDES FIXING OF RIDGE BEAM & LOOSE CEILING ROOF PANEL FIXED DOWN WITH HEADLOK SCREW 250 AT 400mm c/c ROOF PANEL FIXED DOWN WITH HEADLOK SCREW 100 AT 400mm c/c RIDGE BEAM FIXED CENTRALLY WITH HEADLOK SCREWS 150 AT 600mm c/c FIXED FROM ALTERNATE SIDES RIDGE DETAIL- 45 DEG ROOF PITCH ALL HOLES FILLED WITH SQUARE TWIST NAILS SCREW 250 SCREW 95 SCREW 150 TWISTNAIL 35 250 x 6mm HeadLok screws used for fixing roof panels to wall panels. Fixed at 400mm c/c and 100mm in from end. OR 95 HeadLok screws used for fixing roof timber to ply splines together at 600mm c/c OR 150 HeadLok screws used for fixing SIPs wall panels to SIPs wall panels at 400mm c/c and 100mm in from end. OR 35mm x 4mm Square twist nails are used to fix joist hangers or truss clips. All holes to be filled. Simpson Strong Tie washer head screw Code: ESCR8.0x260 Simpson Strong Tie washer head screw Code: ESCR8.0x80 Simpson Strong Tie washer head screw Code: ESCR8.0x160 2014 ISSUE 9 DM512 This drawing is not site specific. Work to written dimensions only. DO NOT SCALE. If in doubt ask. RIDGE DETAILS
© Copyright 2024 ExpyDoc