Technical data sheet · LÜTZE SUPERFLEX N (C) PVC UL For high

Technical data sheet · LÜTZE SUPERFLEX® N (C) PVC UL
For high requirements
PVC control cables · C-track
compatible · shielded
Subject to technical modification A1391404
Identification
Use/Area of application
Application
Properties
Technical data
UL approval
Type
Part-No.
(4G2,5)
A1391404
• Shielded cable suitable for control, monitoring and measurement with continuous
flexing cycles
• As well as tools, industrial robots, conveyor belts and other continuous moving devices in the industrial environment
• For bending equipment like C-tracks or other linear-flexible applications
• Compatible with all common C-track versions
• Very small cable diameters due to special TPE conductor insulation (HGI) according
to UL standard
• Reduced friction due to very smooth conductor insulation (HGI) for high mechanical
loads
• Low capacitance, very good electrical properties
• Especially developed PVC jacket according to UL class 43
• Filler without wick effect
• Low adhesion, Abrasion-resistant, Tear resistant
• Hydrolysis-resistant, microbe-resistant, and rot-resistant
• Use in dry or damp environment
• Silicone free
• RoHS-compliant
AWM 2570
09.08.2014 – Subject to technical modification
Part-No. A1391404
USA: LUTZE INC.
13330 South Ridge Drive • Charlotte, NC 28273, USA
Tel. +1 (704) 504-0222 • Fax +1 (704) 504-0223
www.lutze.com • [email protected]
United Kingdom: LÜTZE Ltd.
Unit 3, Sandy Hill Park
Sandy Way, Amington • GB-Tamworth, Staffs B77 4DU
Tel. +44 (0)1827 31333-0 • Fax +44 (0)1827 31333-2
www.lutze.com • [email protected]
page 1 of 3
Technical data sheet · LÜTZE SUPERFLEX® N (C) PVC UL
For high requirements
Nominal voltage
Test voltage
Insulation resistance
Temperature range
Minimum bending radius
Jacket material
Burning behavor
Approvals
Outer-∅
Weight
Cu-Index
Design
Number of conductors/cross-section
Conductor structure
600 V 80 °C
3000 V
min. 100 MΩ × km
moving
-5 °C to +80 °C
fixed
-40 °C to +80 °C
moving
D × 10
fixed
D×6
PVC
Flame-retardant according to UL VW-1; DIN EN 50265-2-1, FT1
cURus AWM Style 2570
CSA AWM I/II A/B 80 °C
600 V FT1, CE
UL Oil res 80 °C
DIN EN 60811-2-1
11.0 approx. mm
23.1 kg/100 m
13.4 kg/100 m
Jacket colour
(4G2.5)
Bare copper wire, finest multi-strand according to DIN VDE 0295 class 6, IEC 60228
class 6
Special TPE/HGI conductor insulation, UL certified
Conductors black with white number print according to DIN EN 50334
green/yellow according to DIN EN 50334
Conductors twisted without mechanical stress, pitch layer optimised
Non-woven material over the stranded cable
PVC
Braid from tinned copper wire,
optical covering ≥ 85 %
Oil-resistant PVC jacket with high load capacity according to UL class 43/VDE 0207
TM5
grey RAL 7001
General
Note
CE These products are in conformity with the EU Low Voltage Directive 2006/95/EC
Conductor insulation
Conductor labelling
Ground conductor
Stranding
Banding
Inside jacket
Overall shield
Outer jacket
Logo
09.08.2014 – Subject to technical modification
Part-No. A1391404
USA: LUTZE INC.
13330 South Ridge Drive • Charlotte, NC 28273, USA
Tel. +1 (704) 504-0222 • Fax +1 (704) 504-0223
www.lutze.com • [email protected]
United Kingdom: LÜTZE Ltd.
Unit 3, Sandy Hill Park
Sandy Way, Amington • GB-Tamworth, Staffs B77 4DU
Tel. +44 (0)1827 31333-0 • Fax +44 (0)1827 31333-2
www.lutze.com • [email protected]
page 2 of 3
Technical data sheet · LÜTZE SUPERFLEX® N (C) PVC UL
For high requirements
09.08.2014 – Subject to technical modification
Part-No. A1391404
USA: LUTZE INC.
13330 South Ridge Drive • Charlotte, NC 28273, USA
Tel. +1 (704) 504-0222 • Fax +1 (704) 504-0223
www.lutze.com • [email protected]
United Kingdom: LÜTZE Ltd.
Unit 3, Sandy Hill Park
Sandy Way, Amington • GB-Tamworth, Staffs B77 4DU
Tel. +44 (0)1827 31333-0 • Fax +44 (0)1827 31333-2
www.lutze.com • [email protected]
page 3 of 3