Isover T-P Mineral insulation from stone wool Specification code: MW - EN 13162 - T7 - DS(T+) - DS(TH) - CS(10)40 - PL(5)400 - CP2 - SDi* - MU1 TECHNICAL SPECIFICATION Packaging, Transport, Warehousing Insulating slabs made of Isover mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction have to be protected suitably (vapour-proof foil, layers of the floor construction, etc.) Isover T-P insulation slabs are packed into the PE foil with package height up to 0.5 m. The slabs have to be transported in covered vehicles under conditions preventing their wetting or other degradation. They should be stored flat in sheltered space to maximum layer height of 2 m. Application ■ ■ ■ ■ ■ ■ ■ ■ ■ Precisely cut slabs used in light and heavy floating floors in combination with Isover N/PP insulating strips. There are high quality demands in case of underlay surface of the dry floating floors on which the precise cut slabs are laid. Thanks to its high accuracy and minimum compressibility these slabs are applicable even in the thin anhydride floors. Maximum imposed load for this insulation is 5 kN/ m2. Benefits very good thermal insulation performance fire resistance excellent acoustic properties in terms of noise absorption low vapour resistance - good water vapour penetrability environmentally friendly and hygienic completely hydrophobic long life span resistant to wood-destroying pests, rodents, and insect easy workability - can be cut, drilled into, etc. dimensions, insulation and acoustic Product Isover T-P 2,0 Isover T-P 2,5 Isover T-P 3,0 Isover T-P 4,0 Example of light floating floor assembly Thickness (mm) Dimensions (mm) Per package (m2) 1200 x 600 7.20 1200 x 600 5.76 1200 x 600 5.04 1200 x 600 4.32 Construction assembly Thickness (mm) on reinforced ceiling slab Thickness (mm) 120 mm thick Sterling OSB 22 47 Isover T-P 25 *Dynamic rigidity (MN.m-3) Declared thermal resistance R D (m2.K.W-1) 31 27 26 21 0.50 0.65 0.75 1.00 Weight (kg .m-2) Sound reduction Rw (dB) 17.6 55 20 25 30 40 Thickness tolerance classification T7 complies with allowed tolerance according to EN 13162: 0 mm and + 10%, or + 2 mm, the higher numerical value prevails in both the cases. Technical Parameters Parameter Unit Value Norm - - EN ISO 10456 Wm K 0.039 EN 13162 J kg K 800 ČSN 73 0540-3 thermal insulating properties Condition set for declared values I(10°C) and (udry) Declared value of the thermal conductivity coefficient λD (based on the set of measured values according to EN 12667) Specific capacity cd mechanical properties Compressive stress at 10% deformation (σ10) CS(10) Compressibility (c = dL - dB) CP Specific load value fire safety properties Reaction to fire class Dimensional stability at temperature (70 ± 2) °C DS (T+) Maximum temperature for use Melting temperature tt other properties Moisture resistance factor (µ) MU . . -1. -1 -1. -1 kPa ≥ 40 EN 826 mm kN.m -3 ≤2 1.48 EN 12431 EN 1991-1-1, EN 1990 % °C °C A1 ≤1 200 ≥ 1000 EN 13501-1 EN 1604 DIN 4102 part 17 - 1 EN 12086 Related Documents ■ EC compliance certificate 1390-CPR-0305/11/P ■ Declaration of Performance CZ0001-011 (www.isover.cz/DOP) 1. 7. 2014 The information is valid up to date of publishing. The manufacturer reserves right to change the data. Division Isover Saint-Gobain Construction Products CZ a.s. Počernická 272/96, 108 03 Praha 10 e-mail: [email protected], www.isover.cz The widest offer of thermal, acoustic and fire insulations
© Copyright 2024 ExpyDoc