KaMo-System Indirect Hydraulic Interface Units WK-Mini / WK-Mini-Budget WK-Mini Plus TW Mini Gross price list 06/14 Schematic diagram (sample) Bleed and drain of main riser (on site) Module main riser TTV (thermostatic temperature lead module) Ball valves (on site) KaMo – TW-Mini Installation type 1 without modules Shower, wash basin, etc. Compact radiator Heat meter and water meter unit (on site) Standard radiator Differential pressure valve (0,1 bar) or dynamic volume flow limiter (on site) (to be adjusted according to water quantity for heating circuit). KaMo WK-Mini Complete equipment Installation type 2 Shower, wash basin, etc. Compact radiator Standard radiator Heat meter and water meter unit (on site) KaMo WK-Mini Complete equipment Installation type 3 Floorheating Compact radiator heating flow Cold water heating return Shower, wash basin, etc. control mixing unit Heat meter and water meter unit (on site) Shut-off of main riser with bleed and drain (on site) Distribution pipe Seite 2 Note: Hydraulic diagram is a basic scheme. All indications do not claim to be complete and are without liability. WK-Mini-Budget Indirect Hydraulic Interface Units Price valid for orders of 100 units or more. Type WK-M-B Article No. Indirect heat interface unit to produce DHW with separate heat circuit (2 pipe system) – non modular Euro 608,00 WK-M-B unit 15l/min. 22 plate heat exchanger Including the following components: NP 22-22 43000305 193,00 surplus stainless steel heat exchanger, nickel soldered, 22 plates DRG – Differential pressure valve for secondary heating circuit TWR – Thermostatic hot water temperature control Hard-foam cover – highly thermo-insulated Additional components Type WK-KAS/D6 Article No. 41000075 Euro 56,00 set of 6 ball valves (2 x blue, 2 x red, 2 x green) Note: For electronic control components please see page 6. 1 Heat exchanger WP22-22 4 distance piece for heat meter optinally 110 x ¾” or 130 x 1” 8 distance piece for cold water meter 110 x ¾” 9 Differential pressure valve 11 Thermostatic hot water temperature control 14 sensor for heat meter 60 Strainer 61 Sensor for TWR 14 B 60 61 C D 4 8 A DHW for apartment B Cold water from riser C Heating flow primary D Heating return primary E Heating flow secondary F Heating return secondary G Cold water for apartment 11 1 9 G Primary flow 70 °C 75 °C 80 °C 85 °C Primary return 30 °C 27 °C 26 °C 26 °C Heating volume flow 900 l/h 750 l/h 926 l/h 814 l/h Capacity ca. 42 kW ca. 42 kW ca. 56 kW ca. 56 kW DHW-capacity 15 l/min 15 l/min 20 l/min 20 l/h DHW-temperature 50 °C 50 °C 50 °C 50 °C DCW-temperature 10 °C 10 °C 10 °C 10 °C dp Heating ca. 220 bar ca. 0,190 bar ca. 0,220 bar ca. 0,200 bar dp Water ca.1 bar ca. 1 bar ca. 1,3 bar ca. 1,3 bar F A E Seite 3 WK-Mini Indirect Hydraulic Interface Units Type WK-M-1 Article No. 41001302 Euro 569,50 Basic unit 12l/min. 16 plate heat exchanger NP 22-16 43000373 157,00 surplus stainless steel heat exchanger, nickel soldered, 16 plates Type WK-M-2 Article No. 41001303 Indirect heat interface unit to produce DHW with seperate heat circuit (2 pipe system) Euro 657,00 Basic unit 15l/min. 22 plate heat exchanger NP 22-22 43000305 193,00 surplus stainless steel heat exchanger, nickel soldered, 22 plates Illustration shows unit with basic equipment Additional components Type WK-KAS/D6 Article No. 41000075 Euro 56,00 set of 6 ball valves (2 x blue, 2 x red, 2 x green) Type WS-TWR Article No. 41001042 Euro 104,00 thermostatic hot water control "TWR" 20-50 °C for underfloor heating Type WS-TWR Article No. 41001025 Euro 104,00 thermostatic hot water control "TWR" 40-70 °C Type WK-M-DRG Article No. 41001311 Euro 149,50 differential pressure valve (setting range 50-300 mbar) Type WK-M-RTB Article No. 41001316 Euro 67,00 return temperature limiter (sec.heat circuit-pre adjusted 37,5 °C) Type WK-M-SF Article No. 41001314 Type WS-TTV-S Article No. 41001317 Euro 131,50 thermostatic temperature lead module, One per riser Type WS-TTV-SK Article No. 41001319 Euro 181,00 thermostatic temperature lead module, TTV, mounted at end of riser (on site, incl. ball valve, bleed/drain valve), One per riser Euro 33,50 strainer secondary-return Note: For electronic control components please see page 6. Pumps and accessories Type WK-M-PM Article No. 41001318 Covers Euro 179,00 injection circuit (without pump and actuator) Type WK-M-F Article No. 43000144 3-point actuator Seite 4 Article No. 43000348 Euro 158,50 high efficiency pump for underfloor heating ( Laing, Auto EG) Euro 81,50 fixed command control Type WK-M-E Type WK-PL Type WK-PA Article No. 43000379 Euro on request high efficiency pump for underfloor heating (Grundfos ALPHA) Article No. 43000333 Euro 117,50 Type Article No. Euro on request WK-M-AP 41001320 cover survace mounted, Dimensions (mm): width: 375, height: 442, depth: 280 Type Article No. Euro on request WK-M-AP-S 41001312 cover surface mounted (with viewing hole 100 x 100 mm) Order example Art. No. Type Euro 43100031 room thermostat analog 230 V, 7 days program 41001302 WK-M-1 basic unit 12l/min. 16 plate heat exchanger 41001317 thermostatic temperature lead module, TTV, connected on unit 569,50 131,50 41001042 thermostatic hot water control "TWR" 20-50° C for underfloor heating 104,00 43100115 actuator 230 V, ( currentles closed ) 19,00 41001316 return temperature limiter (sec.heat circuit - pre adjusted 37,5°C) 67,00 41000075 set of 6 ball valves (2 x blue, 2 x red, 2 x green) 56,00 Basic Unit Full equipment 1 Stainless steel plate heat exchanger 2 PM – valve with priority circuit for DHW 3 Cold water limitation plate 4 Distance piece for heat meter (3/4” x 110 mm, Qn 1,5) 5 Air vent of the unit (only unit, not plant) 6 Zone valve for limitation of heating volume flow 7 Multifunctional block for the allocation of further components, immersion sleeve in flow line for heat meter sensor M10x1 16 Base plate, Dimensions (mm): width: 298, height: 440, depth: 216 26 Strainer – flow primary 27 Strainer DCW A DHW for apartment B DCW from riser C Heating water – primary flow 9 Differential pressure valve DRG in entrance of the unit 10 Thermostatic lead module TTV 11 Thermostatic hot water control TWR 12 Strainer for apartment heating circuit 20 Ball valves ¾” internal thread D Heating water – primary return E Heating – secondary flow F Heating – secondary return Capacity production of DHW WK1-Mini: Primary flow: 70 °C, 65 °C, 65 °C Primary return: 32 °C, 35 °C, 31 °C Heating volume flow: 760 l/h, 960 l/h, 925 l/h Capacity: 34kW, 34 kW, 36,5 kW DHW-capacity: 12l/min, 12 l/min, 15 l/min DHW-temperature: 50 °C, 50 °C, 45 °C DCW-temperature: 10 °C, 10 °C, 10 °C Capacity production of DHW WK2-Mini: Primary flow: 65 °C, 70 °C Primary return: 27 °C, 30 °C Heating volume flow: 828 l/h, 900 l/h Capacity: 36,5kW, 42kW DHW-capacity: 15l/min, 15l/min DHW-temperature: 45 °C, 50 °C DCW-temperature: 10 °C, 10 °C Capacity during heating operation: Primary flow: 70 °C, 65 °C Primary return: 50 °C, 45 °C Heating volume flow: 645 l/h 645 l/h Capacity: 15 kW 15 kW Seite 5 WK-Mini Plus Indirect Hydraulic Interface Units Type WK-MP-1 Article No. 41001201 Euro 511,00 Indirect heat interface unit to produce DHW with seperate heat circuit (2 pipe system) Basic unit 12l/min. 16 plate heat exchanger Type WK-MP-2 Article No. 41001202 Euro 529,50 Basic unit 15l/min. 22 plate heat exchanger Additional components Type TW-KAS/D4 Article No. 41000007 Pumps and accessories Euro 37,50 Article No. 41001042 Euro 104,00 thermostatic hot water control "TWR" 20-50 °C for underfloor heating Type WS-TWR Article No. 41001025 Euro 104,00 thermostatic hot water control "TWR" 40-70 °C Type WS-WMZ Article No. 49000014 Article No. 41001311 Euro 146,00 differential pressure valve (setting range 50-300 mbar) set of 4 ball valves (2 x blue, 2 x red) Type WS-TWR Type WK-M-DRG Type WS-TTV-S Article No. 41001317 Euro 131,50 thermostatic temperature lead module Type WS-TTV-SK Article No. 41001319 Article No. 41001205 Euro 164,00 injection circuit (without pump and actuator) Type WK-PL Article No. 43000348 Euro 158,50 high efficiency pump for underfloor heating ( Laing, Auto EG) Euro 181,00 thermostatic temperature lead module, TTV, mounted at end of riser (on site, incl. ball valve) Euro 13,50 Type WK-PA Article No. 43000379 Euro on request high efficiency pump for underfloor heating (Grundfos ALPHA) Type WK-M-F assembling heat meter Article No. 43000144 Euro 81,50 Article No. 43000333 Euro 117,50 Article No. 43100188 Euro 20,50 fixed command control Cover Type WK-M-AP Type WK-MP-PM Article No. 41001206 Type WK-M-E Euro 3-point actuator on request cover survace mounted, Dimensions (mm): width: 465, height: 342, depth: 300 „230 V“ electric control units Type WS-KTS Article No. 43100115 Euro 19,00 actuator 230 V, ( currentles closed ) Type WS-KTS-O Article No. 43100069 Article No. 43100016 Euro 23,00 Article No. 43100017 room thermostat , flush mounted, 230 V Seite 6 Article No. 43100073 Euro 30,25 Type WS-RTU-P Article No. 43100018 Euro 44,00 room thermostat flush mounted (night setback) 230 V Euro 17,00 room thermostat on-wall, 230 V Type WS-RTU Type WS-RTA-P room thermostat with night setback, on wall, 230 V actuator 230 V, ( currentles open ) Type WS-RTA „24 V“ Type WS-UTW Article No. 43100031 Euro 92,00 room thermostat analog 230 V, 7 days program Euro 39,50 Type WS-ZP-RTA Article No. 43100074 Euro 2,25 between plate for all room thermostats without analog clock Type WS-KTS-24 actuator 24 V, (currentles closed) Type WS-RTU-P-24 Article No. 43100190 Euro 34,00 actuator 24 V, (currentles open) Type WS-UTW-24 Article No. 43100189 Euro 145,00 room thermostat analog 24 V, 7 days program Type WS-Trafo transformator 230V/24 V Article No. 43100191 Euro 87,00 Order example Art. No. Type Price 41001202 WK-MP-2 Basic unit 12l/min. 22 plate heat exchanger 529,50 41001042 thermostatic hot water control "TWR" 20-50 °C for underfloor heating 104,00 41001311 differential pressure valve (setting range 50-300 mbar) 146,00 41001205 injection circuit (without pump and actuator) 164,00 Basic Unit Full equipment 1 Stainless steel plate heat exchanger 2 PM – valve with priority circuit for DHW 3 Cold water limitation plate 4 Distance piece for heat meter (3/4” x 110 mm, Qn 1,5) 5 Air vent of the unit (only unit, not plant) 16 Base plate, Dimensions (mm): width: 445, height: 225, depth: 294 27 Strainer DCW A DHW for apartment B DCW from riser C Heating water – primary flow D Heating water – primary return E Heating – secondary flow F Heating – secondary return Capacity production of DHW WK-Mini Plus: Primary flow: 70 °C, 65 °C Primary return: 32 °C, 35 °C Heating volume flow: 780 l/h, 957 l/h Capacity: 34 kW, 34 kW DHW-capacity: 12 l/min, 12 l/min DHW-temperature: 50 °C, 50 °C DCW-temperature: 10 °C, 10 °C 9 Differential pressure valve DRG in entrance of the unit 11 Thermostatic hot water control TWR 20 Ball valves ¾” internal thread 22 Not return valve in bypass 24 Control valve (Kvs 2,5) with fixed command control and STB: safety temperature limiter Capacity during heating operation: Primary flow: 70 °C, 65 °C Primary return: 50 °C, 45 °C Heating volume flow: 645 l/h, 645 l/h Capacity: 15 kW, 15 kW Technical specification: Max. working pressure heating: Max. working pressure sanitary: Max. operating temperature heating: Max. differential pressure heating: Min. primary pressure sanitary: Dimensions of base plate w/h/d: Material fittings: PN 10 PN 10 85 °C 2,5 bar 2,0 bar 445 x 225 x 294 mm CW 617 N Seite 7 TW-Mini Indirect Hydraulic Interface Units Type TW-M-1 Article No. 41001301 Euro 512,00 Basic unit 12l/min. 16 plate heat exchanger NP 22-16 43000373 157,00 surplus stainless steel heat exchanger, nickel soldered, 16 plates Type TW-M-2 Article No. 41001304 Indirect heat interface unit to produce DHW (2 pipe system) Euro 551,00 Basic unit 15l/min. 22 plate heat exchanger NP 22-22 43000305 193,00 surplus stainless steel heat exchanger, nickel soldered, 22 plates Illustration shows unit with basic equipment Additional components Type TW-KAS/D4 Article No. 41000007 Euro 37,50 set of 4 ball valve ( 1 x blue, 1 x red, 2 x green) Type TW-M-DRG Article No. 41001321 Euro 166,50 differential pressure valve (setting range 50-300 mbar) Type TW-M-TWR Article No. 41001313 Euro 133,50 thermostatic hot water control "TWR" 40-70 °C Cover Type TW-M-AP Article No. 41001325 Euro on request cover surface mounted, Dimensions (mm): width: 310, height: 500, depth: 190 Seite 8 Type WS-TTV-S Article No. 41001317 Euro 131,50 thermostatic temperature lead module, TTV, mounted at end of riser (on site) Type WS-TTV-SK Article No. 41001319 Euro 181,00 thermostatic temperature lead module, TTV, mounted at end of riser (on site, incl. ball valve) Type TW-M-TTV Article No. 41001322 Euro 73,00 thermostatic temperature lead module, connected on unit Type TW-M-SF Article No. 41001323 Euro 21,00 Article No. 41001324 Euro 76,00 strainer primary flow Type TW-M-WMZ distance piece mounted in the unit Type WS-WMZ assembling heat meter Article No. 49000014 Euro 13,50 Order example Art. No. Type Price 41001301 TW-M-1 Basic unit 12l/min. 16 plate heat exchanger 497,00 41001321 differential pressure valve (setting range 50-300 mbar) 166,50 41000007 set of 4 ball valves (1 x blue, 1 x red, 2 x green) 37,50 Basic Unit Full equipment 1 Stainless steel plate heat exchanger 2 PM – valve with priority circuit for DHW 3 Cold water limitation plate 4 Distance piece for heat meter (3/4” x 110 mm, Qn 1,5) 5 Air vent of the unit (only unit, not plant) 7 Multifunctional block for the allocation of further components 16 Base plate, Dimensions (mm): width: 298, height: 410, depth: 155 26 Strainer – flow primary 27 Strainer DCW A DHW for apartment B DCW from riser 9 Differential pressure valve DRG in entrance of unit 10 Thermostatic lead module TTV 11 Thermostatic hot water control TWR 13 Bleed-drain valve 20 Ball valves ¾” internal thread C Heating water – primary flow D Heating water – primary return Capacity production of DHW TW1-Mini: Primary flow: 70°C, 65°C, 65°C Primary return: 32°C, 35°C, 31°C Heating volume flow: 760l/h, 960l/h, 925l/h Capacity: 34kW, 34kW, 36,5kW DHW-capacity: 12l/min, 12l/min, 15l/min DHW-temperature: 50°C, 50°C, 45°C DCW-temperature: 10°C, 10°C, 10°C Capacity production of DHW TW2-Mini: Primary flow: 65°C, 70°C Primary return: 31°C, 30°C Heating volume flow: 925 /h, 900l/h Capacity: 36,5kW, 42kW DHW-capacity: 15l/min, 15l/min DHW-temperature: 45°C, 50°C DCW-temperature: 10°C, 10°C Technical specification: Max. working pressure heating: Max. working pressure sanitary: Max. operating temperature heating: Max. differential pressure heating: Min. primary pressure sanitary: Dimensions of base plate w/h/d: Material fittings: PN 10 PN 10 85 °C 2,5 bar 2,0 bar 298 x 420 x 216 mm CW 617 N Seite 9 Heat Exchanger: Nickel-soldered stainless steel plate heat exchanger ( SVGW approved ) Max. working pressure, heating: PN16 Max. working pressure, DHW: PN16 Max. operating temperature: 90°C Ball Valves Ball Valves for Heating and DHW Technical specification Ball Valves for heating: ¾” female thread handle (50 mm) red/blue overall length 68 mm internal diameter 16 mm material: CW617N min. wall thickness 2 mm min. max. operating temperature -10°C - +120°C max. working pressure PN40 Differential pressure valve „DRG“ – primary heating input: Curing diaphragm in a red brass body Setting range 50-300 mbar M30 x 1,5 connection Pre adjusted on 250 mbar Diaphragm module fixed on primary heating return Capillary pipe fixed on primary flow Seite 10 Technical specification Ball Valves for DHW: ¾” female thread handle (50 mm) green overall length 68 mm internal diameter 16 mm material: CW602N DVGW-approved min. wall thickness 2 mm min. max. operating temperature -10°C - +120°C max. working pressure PN40 Technical specification: Max. working pressure heating PN10 Max. operating temperature heating 90°C Max. primary differential pressure heating 2,5 bar Thermostatic hot water control set “TWR” Valve with pressure relieved insert,.application up to 4 bar primary differential pressure Control range 20-50°C / 40-70°C, adjustment terminable and lockable Reaction time: +/- 3K Technical specification: Max. working pressure PN10 Max. operating temperature 90°C Max. primary differential pressure 4 bar Return flow temperature limiter RTB: Assures a specific return temperature of the heating circuit. For example 60/40°C. Valve with adjusting scale, directly immerged sensor cartridge, for fast reaction time, pre adjustment lockable Setting range 0-45°C Hysteresis +/-2-3 K Assembling secondary heating return Connection ¾” male, conical Pipe section stainless steel 1.4401 or 1.4521, 18x1 mm Technical specification: Max. working pressure PN10 Max. operating temperature 90°C Max. primary differential pressure heating 2,3 bar Pre adjusted 37,5°C Kvs value 1,55 Strainer secondary return: Buckler with internal Allen key 5 mm. Pipe section stainless steel 1.4401 or 1.4521, 18x1 mm. Strainer insert 0,5 mm. Technical specification: Max. working pressure PN10 Max. operating temperature 90°C Connection 2 x ¾” male, flat sealed Material: CW617N Mesh: stainless steel Shutoff valve in primary return, without actuator Multifunctional base part, with pressure relieved insert, connection for actuatorM30 x 1,5 incl. pipe section. Technical specification: Max. working pressure heating PN10 Max. operating temperature heating 90°C distance piece made of stainless steel 1.4401 or 1.14521 Max. primary differential pressure 4 bar, Kvs 3,5 Distance piece for shutoff valve , primary return Transition piece for ball valve (length 59 mm), adapter elbow 1” F x 1” M Transition piece for ball valve (length 76,5 mm), adapter elbow ¾” F x ¾” F Technical specification: Max. working pressure PN10 Max. operating temperature 90°C distance piece made of stainless stell 1.4401 or 1.14521 Kvs 6 Distance piece made of stainless steel For replacement of the standard distance piece made of plastic Injection circuit with outlet for static heat circuit „PM“, without pump and actuator Pipe section made of stainless steel 1.4401 or 1.4521, for direct connection to the heatboard. Transition piece made of brass, valve with kvs value 0,06-0,9. Pre-adjusted kvs value 0,5, adapter for actuator M30 x 1,5. Non-return valve in bypass, distance piece for external pump ¾” x 1” Thermally decoupled. Technical specification: Max. working pressure heating PN10 Max. operating temperature 90°C Pipes made of stainless steel 1.4401 or 1.14521 Max. primary differential pressure, heating 2 bar Max. primary volume flow for heating 645 l/h Max. performance data according below example: Primary heating flow temp. 65 °C Secondary flow temp. underfloor heating 45 °C (outside temp. -15 °C) Secondary return temp. underfoor heating 35 °C (outside temp. -15 °C) Primary heating return temp. 35 °C Performance date for static heat circuit: Primary/secondary heating flow temperature 65 °C Secondary heating return temperature 45°C Volume flow: 365 l/h Heat capacity up to 8,5 KW Zone valve for static heat circuit provided by customer Heat capacity up to 10 KW (underfloor heating) Primary heating volume flow 280 l/h Secondary heating volume flow 840 l/h Bypass volume flow 560 l/h High efficiency pumps on request: Laing Auto E6 or Wilo Stratos Pico 25/1-6 130 Thermostatic temperature lead module TTV, mounting on heat board. To maintain the heating flow temperature on the primary flow/return on the heat board, if there is no heating operation or DHW production. The temperature adjustment is lockable by sealing wax. Ball valves have to be installed on site, Adjustment range 35-60 °C, Hysteresis +/- 2-3 K Mounting on heat board Technical specification: Max. working pressure heating PN10 Max. operating temperature 90 °C Max primary differential pressure, heating 2,0 bar Pre adjusted on 45 °C Thermostatic temperature lead module „TTV“, mounting on main riser To maintain the heating flow temperature on the main riser, if there is no heating operation or DHW production. The temperature adjustment is lockable by sealing wax. Ball valves have to be installed on site, Adjustment range 35-60 °C, Hysteresis +/- 2-3 K Mounting on the end of main riser 1 x Ball valve with red handle 1 x Ball valve with blue handle 2 x drain/bleed valve Technical specification: Max. working pressure PN10 Max. operating temperature 90°C Max. primary differential pressure, heating 2,0 bar Pre adjusted 45°C Thermostatic temperature lead module „TTV“, mounting on heat board To maintain the heating flow temperature on the primary flow/return on the heat board, if there is no heating operation or DHW production. The temperature adjustment is lockable by sealing wax. Ball valves have to be installed on site, Adjustment range 35-60 °C, Hysteresis +/- 2-3 K Mounting on heat board Technical specification: Max. working pressure heating PN10 Max. operating temperature 90 °C Max primary differential pressure, heating 2,0 bar Pre adjusted on 45 °C Seite 11 Cover surface mounted Hanging on the wall surface, galvanized, zinc-coated steel, white powder-coated Design to avoid condensation or retained warmth Technical specification: Colour: RAL 9016 Material thickness 1,5 mm Actuator 230 V for heating zone valve, electroless-closed, protection class IP54, operating display, first open function, lower connection size M30 x 1,5 mm click connection Actuator 24 V technical specification: max. operating temp. 90°C cable connection 1 m with end sleeve electrical connection 230 V function: electroless closed NC technical specification: electrical connection 24 V Room temperature control 230 V analogue clock, 230 V, and switch pin adjustable week/day program, with function off/day/night/automatic mounting on wall Room temperature control 24 V analogue clock, 24 V. Room thermostat without time control / in-wall or on-wall Control dial with temperature scale 5-30°C Protection class IP30 Electrical connection 230 V Breaking capacity 10A Color white Room thermostat / in-wall or on-wall Control dial with temperature scale 5-30°C Switch heating/night setback, Mode switch day/night/AUTO Protection class IP30 Electrical connection 230 V Breaking capacity 10A Color white KaMo Frischwarmwassersysteme GmbH Max-Planck-Straße 11 89584 Ehingen Telefon: Fax: 0 73 91 / 70 07-0 0 73 91 / 5 43 15 E-Mail: Internet: [email protected] www.kamo.de 43100102 / 1. Auflage 06/14 Transformator 230 V / 24 V Protection class IP67 Capacity 0,7 Ampere Color white With connection box For mounting on base plate
© Copyright 2025 ExpyDoc