STRAIGHT THERMOCOUPLE
PtRh10-Pt(S), PtRh30-PtRh6(B)
Type TER-P-44
Straight thermocouple PtRh10-Pt(S), PtRh30-PtRh6(B)
type TER-P-44 has been designed for high temperature
measurement up to +1600°C mainly in iron blast furnaces, in fire
boxes of heat treatment heaters and for other high temperature
applications.
Where feasible the thermocouple can be equipped with
short protection tube to be used for fixing of ceramic protection
tube. This additional protection tube may be applied along the
whole ceramic tube when special mechanical protection is
required. However, operating temperature is limited to +1400°C
then.
The thermocouples are made in basic or intrinsic save
execution.
THERMOCOUPLE SPECIFICATION
Thermocouple
Max. operating temp.
+1150°C
short time work
+1300°C
permanent work
+11150°C
short time work
+1300°C
Diameter d
Length L1
Max. operating temp.
Ø 22, Ø 30, Ø 33,7
as per client request
Ø 19.1, Ø 22
as per client request
PtRh30-PtRh6 (B)
Characteristic
acc. PN-EN 60584-1
permanent work
PtRh10-Pt (S)
Junction
ungrounded
Protection tube
Ceramic protection tube
Length L
as per client request
Connection head
Type
DA, DAN
Max. operating temp.
+1700°C
Max. operating temp.
+100°C
Material acc.
WNr / DIN
Material acc.
ASTM / AISI
+1150°C
1.4841
314
+1700°C
Kanthal AF
-
Material
Ker 799 (gas leakage proof)
Material
Transmitter
Al
on request
NOTE: Non-standard models available
ALF-SENSOR – manufacturing plant
32-080 ZABIERZÓW, ul. Krakowska 294
ALF-SENSOR – seat
31-342 KRAKÓW, ul. Narcyzowa 3
tel. office (+4812) 258 08 40
tel. commercial dep. (+4812) 258 08 74
fax (+ 4812) 258 08 48
[email protected]
www.alf-sensor.com
Ordering Information
TER-P-44 - A - B - C - D - E - F - G - H -
A. Execution
I
A
Basic
Intrinsic safe
/Exi
1xPtRh-Pt10
2xPtRh-Pt10
1xPtRh30-PtRh6
2xPtRh30-PtRh6
1xS
2xS
1xB
2xB
Ø 19.1
Ø 22
Ø 30
Ø 33,7
19.1
22
30
33,7
B. Type of thermocouple
B
C. Protection tube diameter d
C
D. Protection tube material
D
1.4841
Kanthal AF
E. Protection tube length L1
1.4841
Kanthal AF
E
L1
F. Ceramic protection tube material
specify in mm
F
Ker 799
G. Length L
799
G
L
H. Connection head
specify in mm
H
DA
DAN
I. Transmitter
DA
DAN
I
specify type and range
in °C
Ordering Example
TER-P-44/Exi-1xB-22-1.4841-200-799-400-DA
stands for:
Straight thermocouple in intrinsic save execution with thermoelement 1xPtRh30-PtRh6 and
protection tube diameter Ø22 mm, material 1.4841, length L 1=200mm, ceramic protection tube Ker