John Menatti, Utah Department of Environmental Quality

Electrical Resistance Heating
&
Soil Vapor Extraction
John Menatti
Manager
Petroleum Storage Tank Trust Fund
Utah Department of Environmental Quality
ASTSWMO LUST & State Fund Workshop
Tampa, Florida
May 20, 2014
Jeff Kuhn
McMillan-McGee
Electro-Thermal Dynamic
Stripping Process
Electrical Resistivity Heating/Soil Vapor
Extraction Remediation Project
Former Gas Station
1310 East 3300 South, Salt Lake City, Utah
Facility ID 4001145, Release MKK
For questions, please call:
John Menatti (DEQ) at (801) 554-6560
Kevin Beery (DEQ) at (801) 536-4214
Antea Group at (800) 651-3117
Former UST Basin
Former
Former
Electrode
Ground
Surface
SVE Wells
Silt & Clay
15 ft bgs
Sandy Gravel
30 ft bgs
35 ft bgs
37 ft bgs
Silt & Clay
with several
thin, interbedded
sand & gravel
layers
50 ft bgs
60 ft bgs
47 ft bgs
57 ft bgs
LNAPL Smear Zone and GW Depth (47-53 ft bgs)
Sonic Drilling Rig
LNAPL (gasoline) at 50 feet bgs
in clay
Electrodes
Installing ERH Electrodes using Sonic Drill Rig
Calgary, Alberta, Canada
Thermal Oxidizer
&
Explosion-Proof Blower
Piping
Headers
Vapor Extraction Wells
Testing For Stray
Current
No Stray Current
Detected
January 7, 2014
46.5 feet bgs
November 18, 2013
49.5 feet bgs
37.5 feet bgs
January 6, 2014
49.5 feet bgs
58.5 feet bgs
40.5 feet bgs
46.5 feet bgs
February 5, 2014
52.5 feet bgs
Vapor Temp = 136 degrees F
Vacuum = 8 inches Hg
Flow = 216 cfm
“The Beast”
Thermal Oxidizer
Oct. 28, 2013
ERH-SVE system
startup.
March 1, 2014
1 ton (333 gallons) of
TPH-Gasoline removed
from the subsurface
clayey soil in about 4
months.
Electrical Resistivity Heating/Soil Vapor
Extraction Remediation Project
Former Gas Station
1310 East 3300 South, Salt Lake City, Utah
Facility ID 4001145, Release MKK
For questions, please call:
John Menatti (DEQ) at (801) 554-6560
Kevin Beery (DEQ) at (801) 536-4214
Antea Group at (800) 651-3117