ES-A-C400_C400N_C400Z Colt Series C400, C400N, C400Z TM Reduced Pressure Zone Assemblies Sizes: 21⁄2" – 10" (65 – 250mm) LEAD FREE* C400 OSY C400N BFG Features • Extremely Compact Design • 70% Lighter than Traditional Designs • 304 (Schedule 40) Stainless Steel Housing & Sleeve • Groove Fittings Allow Integral Pipeline Adjustment • Patented Link Check Provides Lowest Pressure Loss • Unmatched Ease of Serviceability • Available with Grooved Butterfly Valve Shutoffs • May be Used for Horizontal or N Pattern Installations • Replaceable Check Disc Rubber The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies provide protection to the potable water system from contamination in accordance with national plumbing codes. The Colt C400, C400N, C400Z are normally used in health hazard applications for protection against backsiphonage, backpressure and the fouling of either check valve. The Colt C400, C400N, C400Z features Lead Free* construction to comply with Lead Free* installation requirements. Specifications The Colt C400, C400N, C400Z Reduced Pressure Zone Assemblies shall consist of two independent Link Check modules, a differential pressure relief valve located between and below the two modules, two drip tight shutoff valves, and required test cocks. Link Check modules and relief valve shall be contained within a sleeve accessible single housing constructed from 304 (Schedule 40) stainless steel pipe with groove end connections. Link Checks shall have reversible elastomer discs and in operation produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. Lead Free* Reduced Pressure Zone Assemblies shall be constructed using Lead Free* materials. It shall comply with state codes and standards, where applicable, requiring reduced lead content. Assembly shall be Colt C400, C400N, C400Z as manufactured by the Ames Company. NOTICE *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. NOTICE Inquire with governing authorities for local installation requirements Job Name_________________________________________________ Contractor_______________________________________________ Job Location_______________________________________________ Approval________________________________________________ Engineer__________________________________________________ Contractor’s P.O. No._______________________________________ Approval__________________________________________________ Representative____________________________________________ Ames Fire & Waterworks product specifications in U.S. customary units and metric are approxim ate and are provided for reference only. For precise measurements, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. Pressure — Temperature Configurations Temperat ure Range: 33°F – 140°F (0.5°C – 60°C) Maximum Working Pressure: 175psi (12.1 bar) • Horizontal • “Z” pattern horizontal Note: When installing a drain line on Series C400 backflow preventer use 400/500 air gap. See ES-A-AG/EL/TC for additional information. • “N” pattern horizontal Materials • Housing & Sleeve: 304 (Schedule 40) Stainless Steel Available Models • Elastomers: EPDM, Silicone and Buna ‘N’ Suffix: ® • Link Checks: Noryl , Stainless Steel NRS - non-rising stem resilient seated gate valves • Check Discs: Reversible Silicone or EPDM OSY - UL/FM outside stem and yoke resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch • Test Cocks: Bronze Body Nickel Plated • Pins & Fasteners: 300 Series Stainless Steel • Springs: Stainless Steel *OSY FxG - Flanged inlet gate connection and grooved outlet gate connection Noryl® is a registered trademark of SABIC Innovative PlasticsTM. *OSY GxF - Grooved inlet gate connection and flanged outlet gate connection Approvals *OSY GxG - Grooved inlet gate connection and grooved outlet gate connection ** 1013 B64.4 Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions ** (**BFG & OSY Only) For additional approval information please contact the factory or visit our website at www.amesfirewater.com Dimensions — Weights C (open) J M I D H A P G C400, C400N, C400Z Size (DN)dimensions weight A C (OSY) C (NRS) D G H I J M P C400 NRS OSY C400N NRS OSY in. mmin.mmin. mmin.mmin. mmin. mmin.mmin. mmin.mmin. mmin. mm lbs. kgs. lbs. kgs. lbs. kgs. lbs. kgs. 21⁄265303⁄4781 163⁄8416 93⁄8 238 61⁄2165 291⁄16738 3 80 313⁄4806 187⁄8479 101⁄4260 611⁄16170 301⁄4768 4 100333⁄4857 223⁄4578 123⁄16310 7 178 33838 6 150431⁄21105 301⁄8 765 16 406 81⁄2216 443⁄41137 8 200493⁄41264 373⁄4959 1915⁄16506 911⁄16246 541⁄81375 10 250 573⁄41467 453⁄41162 2313⁄16 605113⁄16285 661676 211⁄2546 151⁄2393 813⁄16223211⁄4540 93⁄16 23411854 128 58 12657 221⁄4565 171⁄8435 93⁄16 233 23 584101⁄226713461 148 67 14767 231⁄2597 181⁄2470 915⁄16252261⁄4667113⁄1628416474 164 74 187 85 351⁄4895233⁄16 589131⁄16332341⁄4870 15 381276125 298 135 317144 401⁄81019277⁄166971511⁄16399 367⁄8937173⁄16437441200 483 219 516234 491⁄21257 321⁄2826175⁄16440441⁄2 1124 20 508 723328 783 355 893405 136 62 161 73 187 85 339154 558253 950431 Dimensions — Weights M J I H G P C400NBFG/C400ZBFG Size (DN)dimensionsWEIGHT G H I J M P C400N, C400Z in. mmin. mmin.mmin.mmin.mmin.mmin.mm lbs. kgs. 21⁄265 23 584 23 584151⁄239491⁄2241193⁄4 5021113⁄16300 6730 3 80 24 610 24 610165⁄16 414101⁄16256 211⁄4540121⁄83087032 4100251⁄2 648251⁄2648 173⁄16 4371015⁄16279 231⁄2597125⁄83218739 6150351⁄4 895351⁄4895 201⁄2 521131⁄2343 271⁄4692 15 38216073 C D 6" Colt BFG " C400BFG PSID 16 14 12 10 8 A 6 P 4 C400 BFG 2 Size (DN)dimensionsWEIGHT 0 CD P A in. mmin. mmin.mmin.mmin.mmlbs.kgs. 0 200 400 600 800 1000 1200 1400 1600 Flow (GPM) 4 100 29 73773⁄4197 63⁄8 16291⁄2241 66 30 6 150361⁄2 927911⁄16246 77⁄16 189141⁄4362 122 55 Capacity - C400 BFG 4" (100 mm) 6" (150 mm) 4" Colt BFGs psi 25 Service Flow Rated Flow *UL Flow PSID USC 6"Rated C400BFG 25 psi 16 14 12 10 8 6 4 2 0 6" Colt BFG Service Flow Rated Flow *UL Rated Flow 16 14 20 PSI DROP (*FRICTION LOSS) 20 PSI DROP (*FRICTION LOSS) USC 4" C400BFG PSID 15 15 10 10 5 5 12 10 8 6 4 2 0 0 0 0 100200300400500600700800 gpm 0 380 760 1140 1520 1900 2280 2680 3040lpm 7.513 fps 0 100 200 300 400 500 600 700 800 0 200 400 600 800 1000 1200 1400 1600gpm 0 760 1520228030403800456053006060 lpm 7.512 fps 0 200 400 600 800 Flow (GPM) 1000 1200 1400 1600 Capacity Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. • Rated Flow identifies maximum continuous duty performance determined by AWWA. • UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. • AWWA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than 10fps. UL/FM Certified Flow Characteristics N&Z Flow characteristics collected using butterfly shutoff valves. Horizontal Z - Pattern 21⁄2" (65mm) Service Flow Rated Flow 6" (150mm) psi 18 16 14 12 10 8 6 *UL Rated Flow Z N PSI DROP (*FRICTION LOSS) psi 18 16 14 12 10 8 6 N - Pattern H Service Flow 3" (80mm) Rated Flow 14 Z N H psi 18 16 14 12 10 8 6 Service Flow 8 6 0 100200 300400 500 gpm 0 380 760 1140 1520 1900lpm 7.515 fps 0 0 4" (100mm) PSI DROP (*FRICTION LOSS) 22 Rated Flow *UL Rated Flow Z N H 500 1900 1000 1500 2000 2500gpm 3800 5700 7600 9500lpm 7.5 10fps 10" (250mm) *UL Rated Flow Z N H psi 16 14 12 10 8 6 4 Service Flow Rated Flow *UL Rated Flow PSI DROP (*FRICTION LOSS) Service Flow Rated Flow PSI DROP (*FRICTION LOSS) PSI DROP (*FRICTION LOSS) 10 psi 26 *UL Rated Flow 8" (200mm) *UL Rated Flow N Z H 12 Rated Flow 0 3006009001200 1500 gpm 0 1140228034204560 5700 lpm 7.512 fps 0 50 100 150 200 250 300 350gpm 0 190 380 570 760 950 1140 1330lpm 15 fps psi 16 Service Flow PSI DROP (*FRICTION LOSS) 18 14 10 6 0 100 200 300 400 500 600 700 800gpm 0 380 760 1140 1520 1900 2280 2660 3040lpm 7.513 fps Z N H 0 500 1000150020002500 3000 3500 gpm 0 190038005700760095001140013300lpm 7.510 fps NOTICE Inquire with governing authorities for local installation requirements A Watts Water Technologies Company USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com ES-A-C400_C400N_C400Z 1417 © 2014 Ames Fire & Waterworks
© Copyright 2024 ExpyDoc