PRODUCT INFORMATION OTICON RIA PRO OTICON RIA Oticon Ria is built on the new Inium platform and is our best performing hearing solution in the essential category. The audiology in Ria provides its users essential listening performance in several situations and allows to factoring in listening preferences and needs of each client. FITTING RANGE -10 0 10 20 30 40 50 60 70 80 90 100 110 120 The Ria family styles range from compact in-the-ear styles, including new Invisible-In-the-Canal (IIC) custom instruments for users looking for ultimate discretion, and ITE 100 for severe hearing losses, to a broad palette of Behind-The-Ear styles. The RITE instruments use Oticon’s miniFit receivers and the BTE instruments use the new Corda miniFit thin tubes, allowing to share the miniFit soft domes and custom ear pieces. dB HL 125 250 500 1k 2k 4k 8k Hz Ria can be fitted to users with mild to severe-to-profound hearing losses. YouMatic Essential Inium feedback shield Family Features YouMatic is a personal automatic system programmed to the client’s individual needs and sound preferences. Inium feedback shield is an effective feedback protection system implemented on the new Oticon Inium platform. Inium feedback shield is a hybrid system combining two anti-feedback principals to both prevent and suppress feedback without superimposing artefacts to the signal quality or sacrificing audibility. ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ YouMatic Essential makes it easy to adjust the instrument’s reaction and response performance to better match clients’ preferences in terms of comfort, support and clarity in sound. Free Focus Essential Free Focus Essential switches seamlessly between two modes – Optimised Omni and Split directionality – with the possibility to manually switch to Full directionality in very difficult listening situations. Optimsed omni is a new mode of directionality specifically developed to improve speech understanding by mimicking the natural front focus of the pinna to provide the desired access to the speech signal. INIUM WIRELESS Based on the environment, the system deploys the best combination of real time phase inversion and frequency shift to deliver great sound quality at all times. ❍ ❍ ❍ ❍ YouMatic Essential Binaural Synchronisation Binaural PB Coordination Fitting Bandwidth 8 kHz Inium feedback shield Free Focus Essential Artificial Intelligence Essential Memory T-coil AutoPhone Program Modulation Based Singleband Directionality NAL-NL1, NAL-NL2 and DSL v5.0a m[i/o] Flexible miniFit receiver system ConnectLine enabled DAI input and FM option In-situ audiometry (Genie) PRODUCT OVERVIEW RITE STYLES CUSTOM STYLES -10 0 10 20 30 40 50 60 70 80 90 100 110 120 dB HL 125 250 500 1k 2k 4k 8k Hz -10 0 10 20 30 40 50 60 70 80 90 100 110 120 dB HL 125 250 500 1k 2k 4k 8k Hz -10 0 10 20 30 40 50 60 70 80 90 100 110 120 dB HL 125 250 500 1k 2k 4k 8k Hz -10 0 10 20 30 40 50 60 70 80 90 100 110 120 dB HL 125 250 500 1k 2k 4k 8k Hz -10 0 10 20 30 40 50 60 70 80 90 100 110 120 dB HL 125 250 500 1k 2k 4k -10 0 10 20 30 40 50 60 70 80 90 100 110 120 8k Hz dB HL 125 250 500 1k 2k Custom mould Bass & Power dome OSPL90 (peak) Full-on gain (peak) BTE STYLES 4k -10 0 10 20 30 40 50 60 70 80 90 100 110 120 8k Hz dB HL 125 250 500 1k 2k 4k 8k Hz -10 0 10 20 30 40 50 60 70 80 90 100 110 120 dB HL 125 250 500 1k 2k 4k Open dome -10 0 10 20 30 40 50 60 70 80 90 100 110 120 8k Hz Custom mould dB HL 125 250 500 1k 2k 4k 8k Hz Corda miniFit Ear simulator 121 dB SPL 126 dB SPL 130 dB SPL 135 dB SPL 115 dB SPL 127 dB SPL 132 dB SPL 131 dB SPL 126 dB SPL 135 dB SPL 2cc coupler 109 dB SPL 117 dB SPL 121 dB SPL 127 dB SPL 105 dB SPL 118 dB SPL 124 dB SPL 121 dB SPL 117 dB SPL 126 dB SPL Ear simulator IIC 45 dB / CIC 49 dB 59 dB 64 dB 71 dB 46 dB 65 dB 66 dB 62 dB 61 dB 68 dB 2cc coupler IIC 35 dB / CIC 38 dB 50 dB 54 dB 62 dB 35 dB 55 dB 57 dB 53 dB 51 dB 60 dB IIC CIC ITC ITE - Half Shell ITE - Full Shell Battery size miniRITE RITE miniBTE BTE13 10 312 13 312 312 312 13 100 75-135 140-250 80-110 80-110 115-140 85-190 Fitting levels Battery life (h)* Wireless Directional Volume control Telecoil AutoPhone Connectline compatible FlexConnect Mini FlexConnect Mini FlexConnect Programming shoe Cable #3 directly Programming shoe Program control FM compatible Programming interface, cable #3 FlexConnect Mini Default Option CUSTOM STYLES Wax protection Receiver in all instruments ProWax Microphone in 10 battery instruments. T-Cap Microphone in 312 and 13 battery instruments. O-Cap Instruments with 312 battery may be produced with horizontal battery drawer depending on ear geometry. Oticon optimises fitting level and venting by default according to hearing loss, requested instrument style, and ear geometry. * Real usage battery life is shown as an estimated interval based on measurements with variable amplification settings and variable input levels. GENERAL INFO BTE/RITE STYLES Tamper resistant battery drawer Available in 7 colours for all BTE and RITE styles. DAI adaptor AP900 (available for BTE13 and RITE styles). Dedicated FM receiver Amigo R12 (available for BTE13 and RITE styles). FM adaptor FM 9 (available for BTE13 styles) Compatible with Amigo R1, R2 and other universal receivers (not recommended for instruments using 312 batteries). FITTING LEVELS Custom RITE BTE 70 dB 90 dB 110 dB 2 3 PRODUCT OVERVIEW GENERAL FITTING F I T T I N G TA R G E T S Oticon Ria instruments are programmed using the Genie 2014.1 fitting software or higher compatible with NOAH 3 or higher. They can be programmed using either programming cables #3 or cordlessly using nEARcom (TM#1). From Genie 2014.1 we have changed the way we show the target for NAL-NL1, NAL-NL2 and DSL v5a Adult and DSL v5a Pediatric to be aligned with the target as provided by The National Acoustic Laboratories (NAL) & Western University. This is to ensure better Real Ear Measurement (REM) transparency. Cordless fitting - nEARcom nEARcom provides a cordless link between NOAHlink and one or two wireless enabled hearing instruments. In addition nEARcom provides a pass-through connection to accommodate programming cables and replaces the existing NOAHlink neck loop (not availble with IIC and CIC instruments). The target calculation in Genie is no longer taking the acoustics and hardware characteristics of the hearing instrument into account. Therefore minor differences between the target curves and the simulated curves will appear. The new target depiction is closer to the target calculated by the prescription. There is no change to the actual performance and the actual fitting of the hearing instrument. RITE STYLES Receiver unit Must use miniFit receivers. Select between three receiver types with different output performance, labeled according to fitting capabilities; 60, 85 and 100. 60 and 85 available in lengths from size 0–5. 100 available in lengths from size 1–5. Receiver wire Separate wires connect Power Flex moulds (100) to RITE instruments, available in lengths from size 1–5. Receiver connector Type C1 (marked on packaging). to instrument Ear Pieces Must use miniFit ear pieces. Open domes in size 6, 8 and 10 mm. Bass domes, single vent in size 6, 8, 10 and 12 mm. Bass domes, double vent in size 6, 8, 10 and 12 mm. Power domes in size 6, 8, 10 and 12 mm. Custom ear pieces are available as LiteTip and Micro mould (requires taking an impression). Wax protection ‘ProWax miniFit’ in all miniFit receivers. ‘ProWax’ in Power Flex mould, LiteTip and Micro mould. BTE STYLES 4 Sound hook Interchangeable standard and child hook Damper Damping plug available for BTE13 85 Thin tubes Corda miniFit (0.9 mm tubes) for miniBTE 85 and BTE13 85. Corda miniFit Power (1.3 mm tubes) for BTE13 100. Thin tubes are available in lengths from size -1 to 4. Style specific adapters must be used when connecting thin tubes. Ear pieces Must use miniFit ear pieces. Open domes in size 6, 8 and 10 mm. Bass domes, single vent in size 6, 8, 10 and 12 mm. Bass domes, double vent in size 6, 8, 10 and 12 mm. Power domes in size 6, 8, 10 and 12 mm. Custom ear pieces are available as LiteTip and Micro mould (requires taking an impression). Wax Protection ‘ProWax’ in LiteTip and Micro mould. MODEL FEATURES Oticon Ria Pro Oticon Ria Fitting formulas NAL, DSL NAL, DSL YouMatic Essential Essential Binaural Synchronisation (automatics) Yes No Binaural Coordination (PB operations) Yes Yes Fitting Bandwidth* Free Focus 8 kHz 8 kHz Essential Essential Inium feedback shield Yes Yes Artificial Intelligence Essential Essential Fitting Bands 6 4 Frequency channels 16 16 * Bandwidth accessible for gain adjustments during fitting CO LO U R S E L EC T I O N RITE & BTE STYLES 90 Chroma Beige 94 Terracotta 93 44 91 03 04 05 Chestnut Brown Silver Silver Grey 92 Steel Grey 63 Diamond Black CUSTOM STYLES 01 Beige 02 Light Brown Medium Brown Dark Brown Black IIC only POWER FLEX MOULDS 01 Beige 02 Light Brown 03 Medium Brown 04 Dark Brown 05 Black 06 Transparent 5 miniRITE 60 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 90 80 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 90 80 100 Hz 500 1000 2000 Hz 5000 10000 60 100 Equivalent input noise level (A) Battery consumption Battery life, calculated, hours* Full-on Gain 10 100 200 Hz 500 1000 2000 Hz 5000 200 Hz 500 1000 2000 Hz 5000 10000 80 70 60 100 200 Hz 500 1000 2000 Hz Peak 115 dB SPL 1600 Hz 110 dB SPL 101 dB SPL Average 108 dB SPL 103 dB SPL 5000 105 dB SPL Peak 46 dB 35 dB 1600 Hz 37 dB 29 dB Average 34 dB 30 dB 30 dB 26 dB 100-7200 Hz 100-7000 Hz 1 mA/m field - - 10 mA/m field - - SPLITS L/R - - 500 Hz <2 % <2 % 800 Hz <2 % <2 % 1600 Hz <2 % <2 % Omni 21 dB SPL 16 dB SPL Dir 29 dB SPL 24 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.1 mA 1.3 mA 130 Size 312 (IEC PR41) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 43/26/<18 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 6 10000 Frequency Response dB SPL Nera_mRiteS_RTG_711 − 13−03−2013 − str_lo − 16:07:29 70 Frequency range 10000 90 80 Reference test gain 5000 20 90 (Input 70 dB SPL) 2000 Hz 30 Frequency Response dB SPL Total harmonic distortion 1000 Nera_mRiteS_FOG_2cc − 13−03−2013 − str_lo − 16:03:35 200 Nera_mRiteS_FOG_711 − 13−03−2013 − str_lo − 16:04:04 30 100 Telecoil output (1600 Hz) 500 40 10 Full-on gain Hz dB 40 20 OSPL90 200 10000 Nera_mRiteS_RTG_2cc − 13−03−2013 − str_lo − 16:07:05 Technical information Omnidirectional mode is used unless otherwise stated. 200 100 Nera_mRiteS_MPO_2cc − 13−03−2013 − str_lo − 16:05:13 110 100 Nera_mRiteS_MPO_711 − 13−03−2013 − str_lo − 16:05:49 110 Scale 1:1 OSPL90 dB SPL miniRITE 85 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 100 90 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 100 90 100 Hz 500 1000 2000 Hz 5000 10000 80 100 Equivalent input noise level (A) Battery consumption Battery life, calculated, hours* Full-on Gain 30 100 200 Hz 500 1000 2000 Hz 5000 10000 Frequency Response dB SPL 200 Hz 500 1000 2000 Hz 5000 10000 Nera_mRiteM_RTG_711 − 13−03−2013 − str_lo − 15:57:11 90 100 90 80 100 200 Hz 500 1000 2000 Hz Peak 127 dB SPL 118 dB SPL 1600 Hz 123 dB SPL 114 dB SPL Average 119 dB SPL 114 dB SPL Peak 65 dB 55 dB 1600 Hz 51 dB 43 dB Average 52 dB 47 dB Frequency range 10000 110 100 Reference test gain 5000 40 110 (Input 70 dB SPL) 2000 Hz 50 Frequency Response dB SPL Total harmonic distortion 1000 Nera_mRiteM_FOG_2cc − 13−03−2013 − str_lo − 15:53:15 200 Nera_mRiteM_FOG_711 − 13−03−2013 − str_lo − 15:53:39 50 100 Telecoil output (1600 Hz) 500 60 30 Full-on gain Hz dB 60 40 OSPL90 200 44 dB 38 dB 100-7500 Hz 100-7200 Hz 1 mA/m field - - 10 mA/m field - - SPLITS L/R - - 500 Hz <2 % <2 % 800 Hz 2.4 % <2 % 1600 Hz <2 % <2 % Omni 25 dB SPL 18 dB SPL Dir 33 dB SPL 25 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.1 mA 1.2 mA 5000 10000 Nera_mRiteM_RTG_2cc − 13−03−2013 − str_lo − 15:56:39 Technical information Omnidirectional mode is used unless otherwise stated. 200 110 Nera_mRiteM_MPO_2cc − 13−03−2013 − str_lo − 15:54:26 120 110 Nera_mRiteM_MPO_711 − 13−03−2013 − str_lo − 15:54:47 120 Scale 1:1 OSPL90 dB SPL 130 Size 312 (IEC PR41) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 45/30/25 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 7 miniRITE 100 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 110 100 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 200 Hz 500 1000 2000 Hz 5000 10000 5000 30 100 200 Hz 500 1000 2000 Hz 5000 Hz 500 1000 2000 Hz 5000 10000 Nera_mRiteP_RTG_711 − 13−03−2013 − str_lo − 16:01:57 200 100 90 80 100 200 Hz 500 1000 2000 Hz Peak 132 dB SPL 124 dB SPL 131 dB SPL 124 dB SPL Average 126 dB SPL 121 dB SPL Peak 66 dB 57 dB 1600 Hz 56 dB 49 dB Average 58 dB 52 dB 50 dB 44 dB 100-7500 Hz 100-7200 Hz 1 mA/m field - - 10 mA/m field - - SPLITS L/R - - 500 Hz 2.5 % <2 % 800 Hz <2 % <2 % 1600 Hz <2 % <2 % Omni 22 dB SPL 16 dB SPL Dir 30 dB SPL 25 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.1 mA 1.3 mA 5000 130 800/1400/2000 MHz: 46/28/23 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 8 10000 Frequency Response dB SPL Size 312 (IEC PR41) IRIL (IEC 60118-13-2011) 10000 Full-on Gain 1600 Hz Frequency range Battery life, calculated, hours* 2000 Hz 110 100 Reference test gain Battery consumption 1000 40 110 100 Equivalent input noise level (A) 500 50 Frequency Response dB SPL 80 (Input 70 dB SPL) Hz Nera_mRiteP_FOG_2cc − 13−03−2013 − str_lo − 15:58:28 100 90 Total harmonic distortion 200 dB Nera_mRiteP_FOG_711 − 13−03−2013 − str_lo − 15:59:00 50 Warning to the instrument dispenser The maximum output capability of the hearing instrument may exceed 132 dB SPL (IEC 711). Special care should be exercised in selecting and fitting the instrument as there may be risk of impairing the remaining hearing of the hearing instrument user. Telecoil output (1600 Hz) 100 60 30 Full-on gain 100 60 40 OSPL90 110 10000 Nera_mRiteP_RTG_2cc − 13−03−2013 − str_lo − 16:01:07 Technical information Omnidirectional mode is used unless otherwise stated. 200 120 Nera_mRiteP_MPO_2cc − 13−03−2013 − str_lo − 15:59:53 130 120 Nera_mRiteP_MPO_711 − 13−03−2013 − str_lo − 16:00:15 130 Scale 1:1 OSPL90 dB SPL RITE 60 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 90 80 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB Hz 500 1000 2000 Hz 5000 10000 100 Hz 500 1000 2000 Hz 5000 10000 Nera_RiteS_MT_711 − 13−03−2013 − str_lo − 16:13:52 80 200 200 Hz 500 1000 2000 Hz 10000 60 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 115 dB SPL 110 dB SPL 101 dB SPL Average 108 dB SPL 103 dB SPL 10000 105 dB SPL Peak 46 dB 35 dB 1600 Hz 37 dB 29 dB Average 34 dB 30 dB 30 dB 26 dB 100-7200 Hz 100-7000 Hz 1 mA/m field 65 dB SPL - 10 mA/m field 85 dB SPL - - 82/82 dB SPL 500 Hz <2 % <2 % 800 Hz <2 % <2 % 1600 Hz <2 % <2 % Omni 21 dB SPL 16 dB SPL Dir SPLITS L/R 5000 70 Peak Frequency range 10000 Frequency Response 1600 Hz Reference test gain 5000 Full-on Gain dB SPL 90 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m Battery life, calculated, hours* 2000 Hz 10 80 100 Battery consumption 1000 20 90 60 Equivalent input noise level (A) 500 30 Frequency Response 70 (Input 70 dB SPL) Hz Nera_mRiteS_FOG_2cc − 13−03−2013 − str_lo − 16:03:35 200 dB SPL Total harmonic distortion 200 dB Nera_mRiteS_FOG_711 − 13−03−2013 − str_lo − 16:04:04 30 100 Telecoil output (1600 Hz) 100 40 10 Full-on gain 80 40 20 OSPL90 90 Nera_RiteS_MT_2cc − 13−03−2013 − str_lo − 16:13:19 Technical information Omnidirectional mode is used unless otherwise stated. 200 100 Nera_mRiteS_MPO_2cc − 13−03−2013 − str_lo − 16:05:13 110 100 Nera_mRiteS_MPO_711 − 13−03−2013 − str_lo − 16:05:49 110 Scale 1:1 OSPL90 dB SPL 29 dB SPL 24 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.1 mA 1.3 mA 130 Size 312 (IEC PR41) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 27/46/51 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 9 RITE 85 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 100 90 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB Hz 500 1000 2000 Hz 5000 10000 100 Hz 500 1000 2000 Hz 5000 10000 Nera_RiteM_MT_711 − 13−03−2013 − str_lo − 16:10:25 100 200 200 Hz 500 1000 2000 Hz 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 127 dB SPL 118 dB SPL 114 dB SPL Average 119 dB SPL 114 dB SPL Peak 65 dB 55 dB 1600 Hz 51 dB 43 dB Average 52 dB 47 dB 44 dB 38 dB 100-7500 Hz 100-7200 Hz 1 mA/m field 79 dB SPL - 10 mA/m field 99 dB SPL - - 95/95 dB SPL 500 Hz <2 % <2 % 800 Hz 2.4 % <2 % 1600 Hz <2 % <2 % Omni 25 dB SPL 18 dB SPL Dir 33 dB SPL 25 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.1 mA 1.2 mA 130 Size 312 (IEC PR41) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 19/41/36 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 10 10000 80 123 dB SPL SPLITS L/R 5000 90 Peak Frequency range 10000 Frequency Response 1600 Hz Reference test gain 5000 Full-on Gain dB SPL 110 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m Battery life, calculated, hours* 2000 Hz 30 100 100 Battery consumption 1000 40 110 80 Equivalent input noise level (A) 500 50 Frequency Response 90 (Input 70 dB SPL) Hz Nera_mRiteM_FOG_2cc − 13−03−2013 − str_lo − 15:53:15 200 dB SPL Total harmonic distortion 200 dB Nera_mRiteM_FOG_711 − 13−03−2013 − str_lo − 15:53:39 50 100 Telecoil output (1600 Hz) 100 60 30 Full-on gain 90 60 40 OSPL90 100 10000 Nera_RiteM_MT_2cc − 13−03−2013 − str_lo − 16:09:52 Technical information Omnidirectional mode is used unless otherwise stated. 200 110 Nera_mRiteM_MPO_2cc − 13−03−2013 − str_lo − 15:54:26 120 110 Nera_mRiteM_MPO_711 − 13−03−2013 − str_lo − 15:54:47 120 Scale 1:1 OSPL90 dB SPL RITE 100 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 110 100 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 200 Hz 500 1000 2000 Hz 5000 10000 100 500 1000 2000 Hz 5000 10000 Nera_RiteP_MT_711 − 13−03−2013 − str_lo − 16:12:11 100 Hz Hz 500 1000 2000 Hz 5000 10000 90 80 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 132 dB SPL 124 dB SPL 131 dB SPL 124 dB SPL Average 126 dB SPL 121 dB SPL Peak 66 dB 57 dB 1600 Hz 56 dB 49 dB Average 58 dB 52 dB 50 dB 44 dB 100-7500 Hz 100-7200 Hz 1 mA/m field 85 dB SPL - 10 mA/m field 105 dB SPL - - 101/101 dB SPL 500 Hz 2.5 % <2 % 800 Hz <2 % <2 % 1600 Hz <2 % <2 % Omni 22 dB SPL 16 dB SPL Dir SPLITS L/R 10000 Frequency Response dB SPL 110 200 200 Peak Frequency range 5000 Full-on Gain 1600 Hz Reference test gain Battery life, calculated, hours* 2000 Hz 30 100 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m Battery consumption 1000 40 110 100 Equivalent input noise level (A) 500 50 Frequency Response dB SPL 80 (Input 70 dB SPL) Hz Nera_mRiteP_FOG_2cc − 13−03−2013 − str_lo − 15:58:28 100 90 Total harmonic distortion 200 dB Nera_mRiteP_FOG_711 − 13−03−2013 − str_lo − 15:59:00 50 Warning to the instrument dispenser The maximum output capability of the hearing instrument may exceed 132 dB SPL (IEC 711). Special care should be exercised in selecting and fitting the instrument as there may be risk of impairing the remaining hearing of the hearing instrument user. Telecoil output (1600 Hz) 100 60 30 Full-on gain 100 60 40 OSPL90 110 30 dB SPL 25 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.1 mA 1.3 mA 10000 Nera_RiteP_MT_2cc − 13−03−2013 − str_lo − 16:11:39 Technical information Omnidirectional mode is used unless otherwise stated. 200 120 Nera_mRiteP_MPO_2cc − 13−03−2013 − str_lo − 15:59:53 130 120 Nera_mRiteP_MPO_711 − 13−03−2013 − str_lo − 16:00:15 130 Scale 1:1 OSPL90 dB SPL 130 Size 312 (IEC PR41) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: <17/49/39 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 11 miniBTE 85 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). 100 100 Technical information Omnidirectional mode is used unless otherwise stated. 200 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 60 50 40 30 100 200 Hz 500 1000 2000 Hz 5000 10000 Standard tube Thin tube (size 1/0.9) 80 Full-on gain (Input 70 dB SPL) Equivalent input noise level (A) Battery consumption Battery life, calculated, hours** Hz 500 1000 2000 Hz 5000 10000 Hz 500 1000 2000 Hz 5000 60 50 40 30 100 200 Hz 500 1000 2000 Hz 5000 Frequency Response dB SPL Std. tube 100 90 80 100 200 Hz 500 1000 2000 Hz 131 (122*) dB SPL 121 (117*) dB SPL 126 (114*) dB SPL 120 (105*) dB SPL Average 119 (116*) dB SPL 118 (109*) dB SPL Peak 62 (61*) dB 53 (57*) dB 1600 Hz 50 (39*) dB 44 (30*) dB Average 50 (52*) dB 46 (40*) dB 43 dB 41 dB 100-7200 Hz 100-6200 Hz 1 mA/m field - - 10 mA/m field - - SPLITS L/R - - 500 Hz <2 % <2 % 800 Hz <2 % <2 % 1600 Hz <2 % <2 % Omni 22 dB SPL 17 dB SPL Dir 29 dB SPL 25 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.1 mA 1.2 mA 5000 130 800/1400/2000 MHz: <18/24/36 dB SPL * For instruments fitted with Corda miniFit ** Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 12 10000 Standard tube Thin tube (size 1/0.9) Size 312 (IEC PR41) IRIL (IEC 60118-13-2011) 10000 Full-on Gain dB Peak Frequency range Total harmonic distortion 200 200 1600 Hz Reference test gain Telecoil output (1600 Hz) 100 110 90 OSPL90 100 Std. tube 100 100 110 Frequency Response dB SPL 110 120 Nera_711_frq_response − 13−03−2013 − str_lo − 15:42:51 Scale 1:1 130 Nera_mBTE_2cc_MPO_update_01−12−11 − 13−03−2013 − str_lo − 15:45:27 110 Nera_mBTE_711_MPO_update_01−12−11 − 13−03−2013 − str_lo − 15:44:48 120 Nera_mBTE_711_gain_update_01−12−11 − 13−03−2013 − str_lo − 15:47:00 130 OSPL90 dB SPL Nera_mBTE_2cc_gain_update_01−12−11 − 13−03−2013 − str_lo − 15:47:45 OSPL90 dB SPL 10000 Nera_2cc_frq_response − 13−03−2013 − str_lo − 15:42:24 Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. BTE13 85 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 100 90 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB Hz 500 1000 2000 Hz 5000 10000 80 100 200 Hz 500 1000 2000 Hz Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 5000 10000 200 Hz 500 1000 2000 Hz 10000 Std. tube 100 90 80 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 126 (126*) dB SPL 117 (123*) dB SPL 121 (108*) dB SPL 114 (100*) dB SPL Average 116 (116*) dB SPL 113 (106*) dB SPL Peak 61 (63*) dB 51 (59*) dB 1600 Hz 50 (36*) dB 43 (28*) dB Average 49 (52*) dB 44 (41*) dB 43 dB 36 dB 100-7200 Hz 100-7000 Hz 1 mA/m field 79 dB SPL - 10 mA/m field 99 dB SPL - - 94/94 dB SPL 500 Hz <2 % <2 % 800 Hz <2 % <2 % 1600 Hz <2 % <2 % Omni 23 dB SPL 18 dB SPL Dir SPLITS L/R 5000 Frequency Response dB SPL Peak Frequency range 10000 Standard tube Thin tube (size 1/0.9) 1600 Hz Reference test gain 5000 Full-on Gain 100 110 90 Battery life, calculated, hours** 2000 Hz 30 Std. tube 100 Battery consumption 1000 40 Nera_BTE13_MT_711 − 13−03−2013 − str_lo − 15:29:49 110 Equivalent input noise level (A) 500 50 Frequency Response dB SPL (Input 70 dB SPL) Hz Nera_BTE13_gain_2cc − 13−03−2013 − str_lo − 15:23:53 200 Standard tube Thin tube (size 1/0.9) Total harmonic distortion 200 dB Nera_BTE13_gain_711 − 13−03−2013 − str_lo − 15:24:21 50 100 Telecoil output (1600 Hz) 100 60 30 Full-on gain 90 60 40 OSPL90 100 32 dB SPL 27 dB SPL Quiescent 1.1 mA 1.1 mA Typical 1.1 mA 1.1 mA 10000 Nera_BTE13_MT_2cc − 13−03−2013 − str_lo − 15:28:48 Technical information Omnidirectional mode is used unless otherwise stated. 200 110 Nera_BTE13_MPO_2cc − 13−03−2013 − str_lo − 15:22:49 120 110 Nera_BTE13_MPO_711 − 13−03−2013 − str_lo − 15:26:14 120 Scale 1:1 OSPL90 dB SPL 240 Size 13 (IEC PR48) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 24/48/45 dB SPL * For instruments fitted with Corda miniFit ** Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 13 BTE13 100 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 60 50 40 30 Warning to the instrument dispenser The maximum output capability of the hearing instrument may exceed 132 dB SPL (IEC 711). Special care should be exercised in selecting and fitting the instrument as there may be risk of impairing the remaining hearing of the hearing instrument user. 100 200 Hz 500 1000 2000 Hz 5000 10000 Standard tube Thin tube (size 1/1.3) 90 100 200 Hz 500 1000 2000 Hz Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m OSPL90 Full-on gain Equivalent input noise level (A) Battery consumption Battery life, calculated, hours** 5000 40 30 100 200 Hz 500 1000 2000 Hz 5000 Frequency Response dB SPL Std. tube 110 100 90 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 135 (132*) dB SPL 126 (128*) dB SPL 120 (108*) dB SPL Average 122 (121*) dB SPL 120 (115*) dB SPL Peak 68 (66*) dB 60 (62*) dB 1600 Hz 60 (44*) dB 52 (36*) dB Average 57 (56*) dB 53 (49*) dB 53 dB 43 dB 100-7200 Hz 100-6000 Hz 1 mA/m field 89 dB SPL - 10 mA/m field 109 dB SPL - - 100/100 dB SPL 500 Hz <2 % <2 % 800 Hz <2 % <2 % 1600 Hz <2 % <2 % Omni 19 dB SPL 16 dB SPL Dir 29 dB SPL 26 dB SPL Quiescent 1.1 mA 1.1 mA Typical 1.1 mA 1.1 mA 240 800/1400/2000 MHz: 24/48/45 dB SPL * For instruments fitted with Corda miniFit Power ** Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment 14 10000 Standard tube Thin tube (size 1/1.3) Size 13 (IEC PR48) IRIL (IEC 60118-13-2011) 10000 Full-on Gain 128 (116*) dB SPL SPLITS L/R (Input 70 dB SPL) 2000 Hz Peak Frequency range Total harmonic distortion 10000 1000 1600 Hz Reference test gain Telecoil output (1600 Hz) 5000 500 50 120 100 Hz 60 Std. tube 110 200 dB Frequency Response dB SPL 120 100 Nera_BTE13P_MT_711 − 13−03−2013 − str_lo − 15:34:09 Technical information Omnidirectional mode is used unless otherwise stated. 200 100 Nera_BTEP_gain_updateCorda_2cc − 13−03−2013 − str_lo − 15:35:54 100 110 10000 Nera_BTE13P_MT_2cc − 13−03−2013 − str_lo − 15:34:48 100 120 Nera_BTEP_gain_updateCorda_711 − 13−03−2013 − str_lo − 15:36:39 110 Nera_BTE13P_MPO_2cc − 13−03−2013 − str_lo − 15:31:55 130 120 Nera_BTE13P_MPO_711 − 13−03−2013 − str_lo − 15:32:34 130 Scale 1:1 OSPL90 dB SPL CUSTOM 75 (IIC ONLY) OTICON RIA PRO E A R S I M U L AT O R 2CC COUPLER Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 90 Technical information All measurements are made on instruments with ProWax receiver and T-Cap microphone protection. 200 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 40 30 20 10 100 200 Hz 500 1000 2000 Hz 5000 10000 100 90 80 70 200 Hz 500 1000 2000 Hz Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m OSPL90 Full-on gain (Input 70 dB SPL) Equivalent input noise level (A) Battery life, calculated, hours* 10000 Hz 500 1000 2000 Hz 10000 40 30 20 10 100 200 Hz 500 1000 2000 Hz 5000 10000 Frequency Response dB SPL 100 90 80 70 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 109 dB SPL 111 dB SPL 103 dB SPL Average 109 dB SPL 103 dB SPL Peak 45 dB 35 dB 1600 Hz 41 dB 33 dB Average 40 dB 34 dB - - 100-7300 Hz 100-7200 Hz 1 mA/m field - - 10 mA/m field - - SPLITS L/R - - 500 Hz <2 % 2% 800 Hz <2 % <2 % 1600 Hz <2 % <2 % 21 dB SPL 18 dB SPL Omni 5000 Full-on Gain dB 121 dB SPL Dir Battery consumption 5000 200 Peak Frequency range Total harmonic distortion 100 1600 Hz Reference test gain Telecoil output (1600 Hz) 90 Frequency Response dB SPL 100 100 Nera−Ria_Pro_IIC_Freq60db_711_S − 14−10−2013 − kbn_tjn − 16:31:18 100 Scale 1:1 110 P084_Intiga−i_8_2cc_FOG − 02−01−2012 − str_lo − 11:01:35 100 120 - - Quiescent 0.7 mA 0.7 mA Typical 0.7 mA 0.7 mA 10000 P084_Intiga−i_8_2cc_FRESP − 02−01−2012 − str_lo − 11:04:22 110 P084_Intiga−i_8_711_OSPL90 − 21−11−2011 − str_lo − 13:25:13 120 OSPL90 dB SPL Nera−Ria_Pro_IIC_FOG_711_S − 14−10−2013 − kbn_tjn − 16:29:51 dB SPL P084_Intiga−i_8_2cc_OSPL90 − 21−11−2011 − str_lo − 13:24:55 Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. 135 (Size 10, IEC PR70) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 14/19/<10 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: For custom instruments, the maximum gain is customised for optimal size and performance. 15 CUSTOM 75 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 30 30 20 200 Hz 500 1000 2000 Hz 5000 10000 90 200 Hz 500 1000 2000 Hz Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 200 Hz 500 1000 2000 Hz 5000 70 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 109 dB SPL Average 110 dB SPL 105 dB SPL Peak 49 dB 38 dB 1600 Hz 43 dB 35 dB Average 41 dB 35 dB 36 dB 27 dB 100-7200 Hz 100-7100 Hz 1 mA/m field 73 dB SPL - 10 mA/m field 93 dB SPL - - 82/82 dB SPL 2.0 % <2 % 800 Hz 2.0 % <2 % 1600 Hz 3.0 % 2.0 % Omni 22 dB SPL 20 dB SPL Dir 31 dB SPL 29 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.0 mA 1.0 mA 135/140/260 Size: 10 (IEC PR70) / 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 28/44/37 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: For custom instruments, the maximum gain is customised for optimal size and performance. 16 10000 80 104 dB SPL Battery life, calculated, hours* 10000 Frequency Response 112 dB SPL 500 Hz 5000 Full-on Gain 121 dB SPL SPLITS L/R Battery consumption 2000 Hz Peak Frequency range Equivalent input noise level (A) 10000 1000 1600 Hz Reference test gain (Input 70 dB SPL) 5000 500 dB SPL 100 100 Total harmonic distortion 100 90 70 Hz 10 100 80 200 20 Frequency Response dB SPL Telecoil output (1600 Hz) Nera ITC75_FOG_711 − 15−03−2013 − str_lo − 15:14:22 40 100 Full-on gain 100 40 10 OSPL90 80 dB Nera ITC75_MT_711 − 15−03−2013 − str_lo − 15:17:38 Technical information All measurements are made on instruments with ProWax and T-Cap or O-Cap protection. Omnidirectional mode is used unless otherwise stated. 200 90 Nera ITC75_FOG_2cc − 15−03−2013 − str_lo − 15:13:11 80 100 10000 Nera ITC75_MT_2cc − 15−03−2013 − str_lo − 15:16:45 90 Nera ITC75_MPO_2cc − 15−03−2013 − str_lo − 15:15:18 110 100 Nera ITC75_MPO_711 − 15−03−2013 − str_lo − 15:15:41 110 Scale 1:1 OSPL90 dB SPL CUSTOM 85 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 40 40 30 200 Hz 500 1000 2000 Hz 5000 10000 100 200 Hz 500 1000 2000 Hz Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 200 Hz 500 1000 2000 Hz 5000 10000 90 80 100 200 Hz 500 1000 2000 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 111 dB SPL Average 117 dB SPL 113 dB SPL 10000 117 dB SPL Peak 59 dB 50 dB 1600 Hz 51 dB 43 dB Average 50 dB 45 dB 44 dB 37 dB 100-7260 Hz 100-7050 Hz 1 mA/m field 81 dB SPL - 10 mA/m field 101 dB SPL - - 90/90 dB SPL 2.0 % <2 % 800 Hz 2.0 % <2 % 1600 Hz 3.0 % 2.0 % Omni 22 dB SPL 19 dB SPL Dir 32 dB SPL 29 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.0 mA 1.0 mA Battery life, calculated, hours* 10000 Frequency Response 119 dB SPL 500 Hz 5000 Full-on Gain 126 dB SPL SPLITS L / R Battery consumption 2000 Hz Peak Frequency range Equivalent input noise level (A) 10000 1000 1600 Hz Reference test gain (Input 70 dB SPL) 5000 500 dB SPL 110 100 Total harmonic distortion 100 100 80 Hz 20 110 90 200 30 Frequency Response dB SPL Telecoil output (1600 Hz) Nera ITC85_FOG_711 − 15−03−2013 − str_lo − 15:20:34 50 100 Full-on gain 100 50 20 OSPL90 90 dB Nera ITC85_MT_711 − 15−03−2013 − str_lo − 15:23:59 Technical information All measurements are made on instruments with ProWax and T-Cap or O-Cap protection. Omnidirectional mode is used unless otherwise stated. 200 100 Nera ITC85_FOG_2cc − 15−03−2013 − str_lo − 15:19:41 90 110 Nera ITC85_MT_2cc − 15−03−2013 − str_lo − 15:23:28 100 Nera ITC85_MPO_2cc − 15−03−2013 − str_lo − 15:22:00 120 110 Nera ITC85_MPO_711 − 15−03−2013 − str_lo − 15:22:36 120 Scale 1:1 OSPL90 dB SPL 125/140/260 Size: 10 (IEC PR70) / 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 21/39/<14 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: For custom instruments, the maximum gain is customised for optimal size and performance. 17 CUSTOM 90 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 dB SPL 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 50 50 40 200 Hz 500 1000 2000 Hz 5000 10000 100 110 100 90 80 Hz 500 1000 2000 Hz Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 5000 500 1000 2000 Hz 10000 200 Hz 500 1000 2000 Hz 100 200 Hz 500 1000 2000 Hz 123 dB SPL 115 dB SPL Average 121 dB SPL 116 dB SPL 121 dB SPL 54 dB Peak 64 dB 1600 Hz 56 dB 47 dB Average 54 dB 49 dB 48 dB 40 dB 100-6980 Hz 1 mA/m field 85 dB SPL - 10 mA/m field 105 dB SPL - - 93/93 dB SPL <2 % <2 % (Input 70 dB SPL) Equivalent input noise level (A) Battery consumption Battery life, calculated, hours* 500 Hz 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 100-7180 Hz Total harmonic distortion 800 Hz <2 % <2 % 1600 Hz 3.0 % 2.0 % Omni 23 dB SPL 19 dB SPL Dir 34 dB SPL 29 dB SPL Quiescent 1.0 mA 1.0 mA Typical 1.0 mA 1.0 mA 140/260 Size: 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 26/55/41 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: For custom instruments, the maximum gain is customised for optimal size and performance. 18 10000 80 130 dB SPL SPLITS L/R 5000 90 Peak Frequency range 10000 Frequency Response 1600 Hz Reference test gain 5000 Full-on Gain dB SPL 100 200 Hz 30 110 100 200 40 Frequency Response dB SPL Telecoil output (1600 Hz) Nera ITC90_FOG_711 − 15−03−2013 − str_lo − 15:26:14 60 100 Full-on gain 100 60 30 OSPL90 100 dB Nera ITC90_MT_711 − 15−03−2013 − str_lo − 15:28:49 Technical information All measurements are made on instruments with ProWax and O-Cap protection. Omnidirectional mode is used unless otherwise stated. 200 110 Nera ITC90_FOG_2cc − 15−03−2013 − str_lo − 15:25:50 100 120 10000 Nera ITC90_MT_2cc − 15−03−2013 − str_lo − 15:28:19 110 Nera ITC90_MPO_2cc − 15−03−2013 − str_lo − 15:27:10 130 120 Nera ITC90_MPO_711 − 15−03−2013 − str_lo − 15:27:34 130 Scale 1:1 OSPL90 dB SPL CUSTOM 100 OTICON RIA PRO OTICON RIA E A R S I M U L AT O R 2CC COUPLER Measured according to ANSI S3.22 (2003) and S3.7 (1995), IEC 60118-7 (2005) and IEC 60318-5 (2006). OSPL90 130 120 110 100 Hz 500 1000 2000 Hz 5000 10000 Full-on Gain dB 60 50 40 200 Hz 500 1000 2000 Hz 5000 10000 90 200 Hz 500 1000 2000 Hz Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 5000 10000 Nera_Ria_ITE100_MT_711 − 03−09−2013 − kbn_tjn − 13:36:32 100 500 1000 2000 Hz 60 50 40 100 200 Hz 500 1000 2000 Hz 100 90 100 200 Hz 500 1000 2000 Hz 127 dB SPL Average 130 dB SPL 123 dB SPL 62 dB Peak 71 dB 1600 Hz 67 dB 59 dB Average 65 dB 58 dB 48 dB 100-6896 Hz 1 mA/m field 95 dB SPL - 10 mA/m field 115 dB SPL - - 105/105 dB SPL <2 % <2 % 800 Hz <2 % <2 % 1600 Hz 2.0 % <2 % Omni 17 dB SPL 15 dB SPL Dir Equivalent input noise level (A) Battery consumption Battery life, calculated, hours* 10000 127 dB SPL 60 dB (Input 70 dB SPL) 5000 Acoustic input: 60 dB SPL Magnetic input: 31.6 mA/m 135 dB SPL 500 Hz 10000 110 100-7029 Hz Total harmonic distortion 5000 Frequency Response 135 dB SPL SPLITS L / R 10000 70 Peak Frequency range 5000 Full-on Gain 1600 Hz Reference test gain Telecoil output (1600 Hz) Hz 120 110 Full-on gain 200 dB SPL 120 OSPL90 100 Frequency Response dB SPL 100 100 dB 70 100 110 Nera_Ria_ITE 100_MT 2cc − 03−09−2013 − kbn_tjn − 13:37:16 Technical information All measurements are made on instruments with ProWax and O-Cap protection. Omnidirectional mode is used unless otherwise stated. 200 120 Nera_Ria_ITE_100_FOG_711 − 04−09−2013 − kbn_tjn − 14:08:50 100 Nera_Ria_ITE100_MPO 711 − 03−09−2013 − kbn_tjn − 13:33:27 130 Scale 1:1 OSPL90 dB SPL Nera_Ria_ITE 100 FOG_2cc − 03−09−2013 − kbn_tjn − 13:21:47 dB SPL Nera_Ria_ITE 100_MPO_2cc − 03−09−2013 − kbn_tjn − 13:34:15 Measured according to IEC 60118-0 (1983) and 60711 (1981) and DIN 45605. 27 dB SPL 26 dB SPL Quiescent 0.9 mA 0.9 mA Typical 0.9 mA 0.9 mA 155/290 Size: 312 (IEC PR41) / 13 (IEC PR48) IRIL (IEC 60118-13-2011) 800/1400/2000 MHz: 15/45/28 dB SPL * Based on the standardised battery consumption measurement (IIC 60118-0.) The actual battery life depends on battery quality, use pattern, active feature set, hearing loss and sound environment Note: For custom instruments, the maximum gain is customised for optimal size and performance. 19 People First is our promise to empower people to communicate freely, interact naturally and participate actively 137552UK / 10.13 Printed on 100% recycled paper People First www.oticon.com
© Copyright 2024 ExpyDoc