Scrutiny Reports Page 1 of 3 Report Generated On: 07-10-2014 Deviation List Report Version Number: 1.0.35 www.bhopalmunicipal.com Proposal Information (Table 1) Plot Details (Table A) Project Details (Table B) Plot Number Location Name Special Location Name of Architect Name of Owner Central Area Others suchita SHILPI SISODIYA Proposal Details (Table C) Plot Abutting Details (Table D) Proposal Number Case Type Colony Name Ward Zone North South East West BMC/0655/Z02/W05/2014 NEW SAHAJ SANGAM BHOPAL Ward-5 Zone-2 -1 -1 -1 -1 - Colony data is not verified. Concerned officer to verify colony data. User Inputs (Parameters of Approved Layout / Khasara Map) (Table 2) Name Description Input Approved BUP Area 0.00 Layout FAR Factor 1.25 Ground Coverage 30.00 Recretional Ground 0.00 Area Building Height 0.00 Amenity 0.00 Area of Road 40.32 Widening Means of access width 7.50 Net Plot Area 7239.69 B/UP Area Existing 0.00 Structure Front Margin 0.00 Rear Margin 0.00 Side1 Margin 0.00 Side2 Margin 0.00 Proposal Plot Width 47.40 Details Plot Depth 18.63 Road Frontage 47.40 Sensitive Zone No Heritage Area No Building Use Residential Details Residential Sub-Use (Dwelling) LowRise Type Detached House http://61.12.126.108:5050/autodcr/Reports/NTSReports/ScrutinyReports.aspx?iProposalID... 10/7/2014 Scrutiny Reports Bed/Seat Capacity Name Plot Details PLOT Page 2 of 3 0 Description Permissible Plot Width Permissible Plot Depth Building Height BLOCK NO 3 (RESI BULDING) Height (According to Master Plan) Reqd/Perm Proposed Status 47.40 18.63 91.48 81.43 Deviation Deviation 14.50 18.00 Deviation Total Number of WCs are 60. Disclaimer: AutoDCR is an input based software tool used by Municipal Corporations but the final approval lies with concerned Officer / Authority. Rules Topic Rule Plot Level Abutting For Group Housing Required width is 24 m. {as per BVN 2012} Road Consumed Permissible FSI is 1.25 {as per BVN 2012} FAR Coverage Permissible coverage should be 33.5% of plot Area. {as per BVN 2012} Area FAR Area Permissible FSI is 1.25 {as per BVN 2012} Frontage 47.40 Road Parking For Residential, Per 100 sqm of BUA 1 Car required. Tank Tenement x 675 Building Level Building Maximum permissible building height is 14.5m {as per BVN 2012} Height Floor (1) Parapet walls on terraces shall not be less than 1.05m in height. As per[Bhumi-Vikas Niyam- regulation Height no.-66,67] (2) For Residential/Commercial/Agriculture use min required floor height is 2.60 m. As per[Bhumi-Vikas Niyam- regulation no.-66,67] (3) Minimum required floor height Basement floor is 2.40 m. As per[Bhumi-Vikas Niyam- regulation no.66,67] Inner For The whole of one side of every room excepting bath, water closet and store room and not abutting on Chowk either the front, rear or side (s) open spaces shall abut on an inner courtyard, whose minimum width shall be 3.00 m. Inner chowk shall have an area, throughout its height, of not less than square of one-fifth of the height of the highest wall abutting the courtyard. Lift Count Minimum 2 lifts required if Building Height is greater than 15m. As per [Bhumi-Vikas Niyam- Regulation C1.80] Passage No Rule applicable. (Bhumi-Vikas Niyam - Regulation 82-VIII) Sanitation (1) 1 WC required for every tenement. (2) 1 Bathroom required for every tenement. Ventilation For Height of building from 12.51 to 18.00 m Size of ventilation shaft is 4.00m and Minimum size of shaft Shaft 1.50m. As per [Bhumi-Vikas Niyam- Regulation C1.56] The above report generated is subjected to the following manual verification done by the concerned officer 1. Input details/road widening etc are checked with the sanctioned layout and verified that the same are drawn in preDCR layer. http://61.12.126.108:5050/autodcr/Reports/NTSReports/ScrutinyReports.aspx?iProposalID... 10/7/2014 Scrutiny Reports Page 3 of 3 The shape, size and dimension drawn for the plot in preDCR layers are verified with the layout plan and actual site condition. 3. The minimum plot area considered for calculation in autoDCR is verified with all the documental areas. 4. The report is checked for all failed entities by concerned of 2. http://61.12.126.108:5050/autodcr/Reports/NTSReports/ScrutinyReports.aspx?iProposalID... 10/7/2014
© Copyright 2024 ExpyDoc