ENERGY-EFFICIENT. STRONG. HEALTHY. RESPONSIBLE. QUIET. GacoCLOSED183M-CAN CELL FOAM CONTRACTOR / APPLICATOR BENEFITS Exceptional Sprayability. Superior formulation provides consistent, forgiving, user friendly foam with predictable yields and less gun clogging. Winter and Summer Formulations. Sprays in any climate; expands your spray window in colder temperatures. Less Viscous. Reduces wear and tear on equipment. Lower Odor. Improves work environment. Excellent Adhesion. Ideal for use on all types of substrates. OWNER / SPECIFIER BENEFITS Energy-Efficient. Seamless air barrier reduces uncontrolled air leakage, lowering energy costs for building owner and homeowner. Strong. Improves overall structural strength of wall and roof systems. Healthy. Reduces condensation, moisture and mold, improving occupant comfort, health and safety. Responsible. Higher aged R-values than conventional insulation. Reduces energy consumption, and contains no ozone-depleting chemicals. Quiet. Acts as a sound barrier to help block airborne noise. CCMC #13644-L Gaco 183M-CAN Closed Cell Foam Product Data Sheet Gaco 183M-CAN is a two component HFC-blown (zero ozone-depleting) liquid spray system that cures to a medium-density rigid cellular polyurethane insulation material. Gaco 183M-CAN contains polyols derived from naturally renewable oils, post-consumer recycled plastics, and pre-consumer recycled materials. This closed cell foam is designed to provide: excellent thermal performance; air impermeable insulation; and, an integral part of an air barrier assembly. The finished material meets or exceeds the requirements of CAN/ULC-705.1. The cured material is pewter in colour. TECHNICAL INFORMATION PROPERTY TEST VALUE UNIT Core Density Aged Thermal Resistance (R-Value) (180 days at 23°C; 50 mm thick specimens) Long Term Thermal Resistance ASTM D1622 ASTM C518 CAN/ULC-S770 Kg/m3 (lbs/ft3) m2·K/W m2·K/W Compressive Strength Tensile Strength Dimensional Stability (7 Days) ASTM D1621 ASTM D1623 ASTM D2126 Open Cell Content Surface Burning Characteristics: Flame Spread Rating Smoke Development Classification Water Absorption Water Vapor Permeance (50 mm thick specimen) Air Permeance @ 75Pa (Infiltration/Exfiltration) Air Barrier Assembly Testing Crack Bridging Pull Adhesion: Concrete Masonry Unit Gypsum Sheathing (Dens Glass) Oriented Strand Board (OSB) Fungi Resistance Volatile Organic Compounds Time to Occupancy ASTM D2856 CAN/ULC-S127 CAN/ULC-S102 ASTM D2842 ASTM E96 – Method A ASTM E2178 ASTM E2357 ASTM C1305 32.2 (2.02) 2.30 3.88 @ 100 mm, 2.79 @ 75 mm, 1.80 @ 50 mm (Type 1), 0.89 @ 25 mm 181 269 -0.1 @ -20°C, 0.5 @ 80°C 6.4 @ 70°C, 97 ± 3% RH 2.6 255 330 0.71 36 0.0013 0.0027 Pass @ -26°C (-15°F) 237 162 210 Pass Pass 1 ASTM C1338 Can/ULC-S774 kPa kPa % volume change % by volume % by volume Ng/Pa·s·m2 L/s·m2 L/s·m2 Pass kPa no growth hour TYPICAL LIQUID CHEMICAL PROPERTIES “A” Component contains polymeric isocyanate. “B” Component contains polyols, catalysts, fire retardants, surfactants and blowing agents. PROPERTY TEST TEMPERATURE TEST VALUE UNIT Viscosity – “A” Component Viscosity – “B” Component Lbs/gal and S.G. – “A” Component Lbs/gal and S.G. – “B” Component Mixing Ratio – “A” & “B” Component Stability When Stored at 10°C to 21°C (50°F to 70°F) 25°C (77°F) ASTM D2196 cps 25°C (77°F) ASTM D1638 180 ± 20 750 ± 50 10.2 / 1.22 10 / 1.20 1:1 “A” Component: 12 months “B” Component: 6 months By volume Months 25°C (77°F) lbs/gal and S.G. APPLICATION To ensure optimum performance, a minimum pass thickness of 1.9 cm (3/4”) is recommended with the maximum not to exceed 5.1 cm (2”) per pass. To obtain optimum results substrate temperature should be within the ranges as stated below. All substrates must be dry at the time of application. Do not apply to wood surfaces with a moisture content of above 18%. Material Substrate Temperature Gaco 183M-CAN 4.4°C - 48.9°C (40°F - 120°F) Gaco 183M-CANW -1.1°C - 37.8°C (30°F - 100°F) EQUIPMENT SETTINGS VALUE PRODUCT CHARACTERISTICS VALUE Pre-Heat Iso (A) Pre-Heat Poly (B) Hose Heat Recommended Spray Pressure 41°C - 54°C (105°F - 130°F) 41°C - 54°C (105°F - 130°F) 41°C - 54°C (105°F - 130°F) 1,200 - 1,400 psi (dynamic) Cream Time Rise Time Tack Free Time Cure Time 0 - 1 sec 3 - 5 sec 3 - 5 sec 4 hours Contact us today for solutions to your building project needs. CANADA | gaco.com | 877 699 4226 The information herein is believed to be reliable but unknown risks may be present. ALL WARRANTIES OF ANY KIND, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND THAT GOODS ARE OF MERCHANTABLE QUALITY, ARE SPECIFICALLY DISCLAIMED. See Gaco Western for information concerning its limited warranty and its availability. For specific Safety and Health information please refer to Material Safety Data Sheet. MKWF1014 0814
© Copyright 2024 ExpyDoc