Technical Specification of CDT-A Series Air cooled Dryer AIR FLOW MODEL CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT CDT (m3 / min) 0.9 1.4 1.8 2.7 4.3 5.5 6.8 8.1 11 15 18 23 28 30 36 43 48 8A 10A 15A 20A 30A 40A 50A 60A 75A 100A 125A 150A 175A 200A 250A 300A 350A (CFM) 32 50 64 95 152 194 240 286 389 530 636 813 990 1060 1272 1519 1696 POWER SUPPLY NOMINAL POWER CONNECTION V / Ph / hz 220 / 1 / 50 220 / 1 / 50 220 / 1 / 50 220 / 1 / 50 220 / 1 / 50 220 / 1 / 50 220 / 1 / 50 220 / 1 / 50 220 / 1 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 380 / 3 / 50 kW 0.31 0.51 0.54 0.96 1.12 1.23 1.57 1.83 2.66 3.28 3.68 4.63 5.03 5.92 6.53 9.11 10.56 inch 1" PT 1" PT 1" PT 1" PT 1 1/2" PT 1 1/2" PT 1 1/2" PT 2" PT 2" PT 2 1/2" PT 2 1/2" PT 2 1/2" PT 2 1/2" PT 3" PT 3" PT 4" FL 4" FL WEIGHT DIMENSION L. 718 718 718 718 868 868 868 1200 1200 1200 1200 1200 1200 1500 1500 1800 1800 W. 388 388 388 388 388 388 388 450 450 600 600 600 600 1000 1000 1000 1000 H. 880 880 880 880 1200 1200 1200 1350 1350 1600 1600 1600 1600 1850 1850 2000 2000 kg. 80 88 91 97 113 128 137 150 200 267 279 324 367 485 536 617 678 H. 600 600 600 600 600 800 800 800 WEIGHT kg. 258 333 476 528 603 790 995 1120 REFRIGERANT R134a R134a R134a R407C R407C R407C R407C R407C R407C R407C R407C R407C R407C R407C R407C R407C R407C Technical Specification of CDT-W Series Water cooled Dryer AIR FLOW (m3 / min) (CFM) 17 595 26 910 33 1155 40 1400 48 1680 68 2380 81 2835 99 3465 MODEL CDT CDT CDT CDT CDT CDT CDT CDT 100W 150W 200W 250W 300W 400W 500W 600W POWER SUPPLY NOMINAL POWER CONNECTION V / Ph / hz kW inch 380 / 3 / 50 2.71 2 1/2" PT 380 / 3 / 50 4.06 2 1/2" PT 380 / 3 / 50 5.21 3" PT 380 / 3 / 50 5.81 3" PT 380 / 3 / 50 7.55 4" FL 380 / 3 / 50 10.11 4" FL 380 / 3 / 50 11.36 6" FL 380 / 3 / 50 13.65 6" FL *The specification subject to change without notice in advance. Fan motor AIR OUTLET CDT - 100 A (Air cooled) W (Water cooled) DIMENSION W. 600 600 600 600 600 800 800 800 C (Digital Temp.) N (Not Digital Temp.) REFRIGERANT R407C R407C R407C R407C R407C R407C R407C R407C O (R22) S (R407c) AIR INLET After cooler Compact heat exchanger Fan motor Air condensor Expansion valve Or capillary tube Auto drain Filter drier High pressure Hot gass by pass valve Dew point gauge Compressor L. 1200 1200 1500 1500 1500 1600 1600 1600 Water condensor Low pressure Dryer maximum air flow = Dryer air flow x K1 x K2 x K3 x K4 Corretion factor Ambient temp. oC Factor ( K1) Air inlet temp. oC Factor (K2) Working pressure Kg/cm Factor (K3) Pressure Dew Point oC Factor (K4) 1, 2, 3, 4, 5, 6, 28 1,14 45 1,12 4 0,80 2 0,96 30 1,11 50 1,08 5 0,90 3 1,00 32 1,08 55 1,00 6 0,94 4 1,04 35 1,00 60 0,92 7 1,00 5 1,06 38 0,96 65 0,84 8 1,04 6 1,08 40 0,89 70 0,72 9 1,07 7 1,10 42 0,82 75 0,70 10 1,10 8 1,14 43 0,78 80 0,68 13 1,13 10 1,16 CDT Series Air Inlet Temperature 80°C (Max.) Pressure Dew Point 2~10 °C Ambient Temperature 10~43 °C Independent After Cooler Air In-Out Pressure Drop < 0.25kg/cm2 2 Years Warranty for Compressor And Evaporator. Most of the Dryers on the Market are without the After-Cooler, usually People choose the bigger size of air dryer or compressor due to no After-Cooler. Result to higher power consumption.
© Copyright 2024 ExpyDoc