ZITARES CCD Dimmable constant current ECG for LED modules (SELV) with 2 channel output Industry Office & Commercial Outdoor Shop Operating data Designation Material number No. of channels Output current Output voltage Max. total output power Input current CCD235-35LS-01/ 220-240/1-10V 10078992 2 CCD235-35LS-01/ 220-240/DALI 10078993 CCD250-50LS-01/ 220-240/DALI Power factor ECG efficiency mA VDC W A 350 10 ... 50 35 0.18 0.98 90 2 350 10 ... 50 35 0.18 0.98 90 10105113 2 500 10 ... 50 50 0.27 0.98 90 CCD270-70LS-01/ 220-240/1-10V 10078996 2 700 10 ... 50 70 0.36 0.98 91 CCD270-70LS-01/ 220-240/DALI 10078997 2 700 10 ... 50 70 0.36 0.98 91 Hole spacing XM (length direction) Hole spacing ZM (height direction) Weight Ambient temperature ta Housing temperature tc,max % - All specifications with 230 VAC nominal operation and 100 % load - Power output in undimmed operation should not go below 20 % of the maximum permissible value - Asymmetric load distribution on the outputs is permissible - Further output currents can be selected via parallel switching of the ECG outputs, see the table „Current selection“ Height Z mm mm mm mm mm kg °C °C CCD2...35LS-01... / 1-10V 280 39 21 270 9 0.295 -25 ... 55 75 CCD2...35LS-01... / DALI 280 39 21 270 9 0.295 -25 ... 55 75 CCD2...50LS-01... / DALI 280 39 21 270 9 0.295 -25 ... 50 75 CCD2...70LS-01... / 1-10V 280 39 21 270 9 0.295 -25 ... 50 75 CCD2...70LS-01... / DALI 280 39 21 270 9 0.295 -25 ... 50 75 Technical data Conformity Output current CCD23535LS··· Z Product information Current selection • Selection of additional output currents by means of parallel connection of the output channels • SELV equiv. output voltage ≤ 60 VDC LED Components • Soft start and low output current ripple • For use in luminaires of protection class I • ECG extensively protected against abnormal operating conditions at the output e.g. short-circuit, open circuit or overload • Suitable for direct current operation and application in combination with central battery installations • Overvoltage protection of the DALI and 1–10 V interfaces up to 264 VAC Rated voltage range 220 ... 240 [V] EN 61347-2-13 Rated frequency 0 / 50 ... 60 [Hz] EN 62384 Admissible continuous voltage range (AC) 198 - 264 [V] EN 61547 Admissible continuous voltage range (DC) 198 ... 278 [V] Max. leakage current 0.5 mA Total harmonic distortion (THD) 10 %, at 100 % load appr. 320 VAC Overvoltage protection (time) 350 VAC / 2 h Output data +/- 5 % • Settable recovery function: automatic switch-on after mains failure Max. ripple output current +/- 10% Output voltage limitation 60 VDC; SELV equiv. • Certified as thermally protected device • Conformance with international regulations, regarding safety and operation, electromagnetic compatibility and immunity to interference • Nominal service life: 50,000 h with failure rate ≤ 10 % and operation at tc=tc,max Product Catalogue 2014 | BAG electronics Galvanic separation to mains input yes, test voltage 3.75 kV Max. starting time 0.5 s PE L 1 2 1 2 N + – + CH2: LED – DA DA Push-DIM 2 - Connection of ECG output side more ECG + – + CH2: LED – CH1: LED C - Connection of ECG input side for 1 - 10V control L N PE – + 1-10V, DALI, Push-Dim – A - Connection of ECG input side for DALI control Dimming range 1...100% Dimming technology PWM Max. Stand-by power (DALI & Push-Dim) 0.3 W DA Max. number of ECGs (Push-Dim) 25 DA Max. control current (1-10V) 0,6 mA PE L + 1-10 V 1-10 V n.c. N DA DA n.c. Degree of protection Degree of protection 2 B - Connection of ECG input side for control via push-button Interfaces and dimming operation Dimming interfaces; depending on ECG model 1x 1 s. Wiring diagrams Designations Output current tolerance • Identical dimensions for dimmable and non-dimmable versions IEC 60068-2-6 1x 1.400 mA CH1: LED Switch-off of the LEDs at overvoltage • Push-Dim function of DALI interface: switching and dimming via push-button • Compact housing for maximum flexibility in luminaire design EN 62386-207 IEC 60068-2-27 Behaviour at mains overvoltage fixed • PWM dimming with 500 Hz for flicker-free light and prevention of stroboscopic effects Wiring diagrams 1 - Connection of ECG output side 2x 1x 1.050 mA X EN 62386-102 2x 700 mA XM CCD27070LS··· 2x 500 mA EN 55015 Constant current • Dimming range: 1 ... 100 % luminous flux 350 mA EN 61347-1 Mains voltage supply Y • Dimmable 2-channel ECG for constant current operation of LED modules CCD25050LS··· LED Components Width Y ZM Electronic control gears | ZITARES CCD Length X Case drawing • Very high efficiency of up to 91 % (100 % load) 66 Short designation Electronic control gears | ZITARES CCD Dimensions | weights | temperatures more ECG IP20 more ECG BAG electronics | Product Catalogue 2014 67
© Copyright 2025 ExpyDoc