Partitions F Building New Solutions Remodelling room partitioning often turns out to be expensive and with a lot involved. By using Lindner’s easily removable partitions you can adapt your rooms to momentary requirements at any time. Lindner partition systems provide decisive advantages for your individual requirements. Various Systems for Lindner LVT Partitions: • Metal partitions F0 / F30 / F90 with G30- / G90-fanlight • Chipboard partitions F0 / F30 / F90 with G30- / G90-fanlight • Plasterboard partitions F0 / F30 / F90 with G30- / G90-fanlight • Glazed partitions F0 / F30 Subject to technical changes also without notification. F2 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Table of Contents LVT systems......................................................................................................... Code designation LVT Partition .................................................................................................................................................................. 4 LVT Solid Partition System .................................................................................... System 100 .................................... 6 LVT Glazed Partition with Hook-on Aluminium Frame ........................................... System 110 .................................. 11 LVT Glazed Partition – flush-fronted double-glazing ............................................ System 125 .................................. 15 LVT Glazed Partition – flush-surface bonded double-glazing................................ System 137 .................................. 19 LVT Glazed Partition with Slim Line Glazing ......................................................... System 140 .................................. 23 Surfaces for Partitions and Wall Cladding ................................................................................................................... 27 Doors ........................................................................................................................................................................... 29 Installation System for Partition Systems ................................................................................................................... 35 Accessories ................................................................................................................................................................. 36 Great Ways to Organise Your Office ........................................................................................................................... 39 LVT Partition for Inspection Chambers F30 .......................................................... System LM 500 ............................ 40 Instructions for Ordering, Installation and Use ............................................................................................................ 41 Standards and Regulations ......................................................................................................................................... 43 LW systems Fully-Glazed Partitions GDL-IGG .......................................................................... System LW 600 ............................ 45 Lindner Fully-Glazed Partition ............................................................................... System LW 620 ............................ 48 Timber Framework Partition .................................................................................. System LW 640 ............................ 51 Fully-Glazed Partition ............................................................................................ System LW 650 ............................ 55 Lindner Safelite SL 90 ........................................................................................... System LW 660 F90 ..................... 58 Team Panel ........................................................................................................... System LW 670 ............................ 61 GK systems Plasterboard Partition .................................................................................................................................................. 64 Lindner Akusto-Wand .................................................................................................................................................. 65 Lindner Fire Wall ................................................................................................... System LGK-530-BW................... 66 G30 Steel Frame Glazing in Plasterboard Partitions ............................................. System LGK-100-G30.................. 67 G90 Steel Frame Glazing in Plasterboard Partitions ............................................. System LGK-110-G90 .................. 69 G30 / F30 Frameless Glazing in Plasterboard Partitions ...................................... System LGK-120-G30/F30 .......... 71 G30 High-performance Sound-Insulation Glazing in Plasterboard Partitions ....... System LGK-140-G30.................. 75 Façade Sword, High-performance Sound-Insulation ............................................ System LGK-500-F0 .................... 77 F90 Access Panel in Plasterboard Shaft Walls or Solid Walls............................... System LGK-510-F90 .................. 78 F0 Access Panel in Plasterboard Partitions .......................................................... System LGK-520-F0 .................... 79 Subject to technical changes also without notification. F3 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Partition Product Description Fig. 1 Exploded view of partiton with infill strip Removable, non-load-bearing partitions for interior fit-out consisting of surface-finished wall panels, glazing and door elements. Lindner‘s LVT-partitions enable flexible room design. Changes can be carried out at any time. After the initial installation it is simple to carry out changes by just moving, removing or adding wall elements, or by exchanging them (e.g. doors). k6106 Fig. 2 Exploded view of linear strip This partition system consists of a sandwich element and can be build as linear or infill strip system. The wall panels are made from 19-mm thick chipboard panels, melamine-coated according to DIN 68 765, Emission Class E1. The panel edges are coated with 0.4-mm to 0.8-mm thick melamine resin as standard. If necessary, 1.5-mm to 3-mm thick plastic or solid wooden edges can also be applied. These are then bevelled. Galvanised steel fixing hooks are screwed onto the reverse sides of the wall panels. Then the panels are ready for hooking into the system studs. As an alternative, panels with real wood veneer on chipboard or gypsum fibre board or metal wall panels are possible. Gaskets are used to seal joints on the floor/ceiling channels and on the stud. k5349 Module Module Element A Element A Module Element A Module Module Element A Module Module Element B Element B Module Element A Element C Module Element A Element A Infill strip system Module Fig. 4 Element A Linear modular system Element B Fig. 3 Subject to technical changes also without notification. F4 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Partition The Substructure Fig. 5 Floor/Ceiling channels with stud The substructure consists of folded and roll-formed steel profiles either galvanised or coated. When PVC-floor coverings are used, the floor channel is designed that it can be fixed and sealed to the side of it, glued and sealed. The standard surface for floor/ceiling channel is powder-coated or coil-coated. The wall panels are held in the system stud by fixing hooks made of galvanised steel. These studs consist of punched, galvanised steel profiles. There are openings in the middle for horizontal installation of electrical cables, etc. k6102 Shelving System Fig. 6 Shelf bracket with shelf inserts The design of this shelving system is ideal for offices. In our partitions there is a concealed hook-on system for shelf brackets attached in the vertical shadow gap along the entire room height. These can be individually adjusted. The requirement upon load capacity is in accordance with DIN 4103-Bracket Loads. k10212 Organisational System Fig. 7 Installing organiser panels is also useful in offices. These are hooked into the system studs instead of a wall panel and are used to fasten numerous organisational materials, such as pigeonholes, furniture or desk sets. Subject to technical changes also without notification. F5 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Solid Partition System System 100 Fig. 8 Subject to technical changes also without notification. F6 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Solid Partition System System 100 Fig. 9 System description A non-load bearing solid partition system with light weight construction that meets the wide variety of requirements upon architectural styling and engineering. This movable partition can be combined with various glazing and supplemented by numerous accessories. Substructure: This consists of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Panelling: Sandwich element construction with hook-on system Chipboard: 19 mm, E1/B2 Metal panel: 13 mm Support panel: 19 mm, A2 Surface: Metal, real wood veneer, melamine resin, laminated sheet material Shelving system / Office equipment: These are integrated/fixed in the horizontal and vertical joints. Fabric panels can be hung up provided they are suitable for pin fixings. Joints and connections: Joints: Concealed in the vertical shadow gaps (along the entire room height) there is a hook-on system attached for shelf brackets. The crosswise organisation is fixed in the horizontal joints. Joint sealant: Plastic profiles are used on the floor and ceiling channels and on stud profile elements. Connections: Recessed floor and ceiling junctions; alternatively: also recessed wall junctions. Special features: - Easy to demount and re-install - Inspection-friendly handling for later installations - Easy to combine with all LVT glazing variations - Matches Lindner floor and ceiling systems Field of application: Offices Industrial and factory rooms Training and research rooms Technical Data Fireproofing: F0 / F30 / F90 as per DIN 4102 EI30 / EI60 as per EN 1364-1 (with metal panel) Soundproofing: up to 54 dB Rw,P as per DIN EN ISO 140-03 Static requirements: Installation area type 1 and 2 Non-supporting partition as per DIN 4103 Height up to max. of 5 000 mm Axial width up to max. of 1 500 mm Weight: 34 – 38 kg/m² (chipboard) 38 – 42 kg/m² (metal) Standard module widths: 1 200 – 1 300 mm Joint width: 6 / 8 mm Partition thicknesses: 100 and 125 mm (19 mm panelling) 89 and 100 mm (13 mm panelling) Applicable standards: DIN 18202, DIN 68100 Customized solutions are possible on request! Subject to technical changes also without notification. F7 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Solid Partition System Fig. 10 Vertical section of Solid partition with chipboard panel Fig. 11 Vertical section of Solid partition with metal panel Fig. 12 Horizontal section of Module with chipboard panel Fig. 13 Horizontal section of Module with metal panel Subject to technical changes also without notification. F8 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Solid Partition System Fig. 14 Horizontal section of 90°-corner Fig. 15 „Horizontal section of T-junction on linear modular system“ Fig. 16 Horizontal section of wall connection with shadow gap Fig. 17 „Horizontal section of T-junction on post cap“ Fig. 18 Horizontal section of wall connection without shadow gap Fig. 19 Horizontal section of stop end Subject to technical changes also without notification. F9 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Solid Partition System Fig. 20 Horizontal section of steel frame Fig. 22 Horizontal section of aluminium frame Fig. 23 Horizontal section of wooden frame Fig. 21 Vertical section of steel frame Fig. 24 Horizontal section of aluminium frame with tubular frame door leaf Subject to technical changes also without notification. F10 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Hook-on Aluminium Frame System 110 Fig. 25 Fig. 26 Subject to technical changes also without notification. F11 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Hook-on Aluminium Frame System 110 Fig. 27 System description A partition consisting of single-pane or thermopane glazing with hook-on type aluminium frame with a visible width of 35 mm. Substructure: Consisting of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Glazing: Single-pane glazing with a single pane or thermopane glazing. The aluminium frames are hooked on later. The frame surface can be enamelled or real wood veneer is possible. Design options: Full glazing Dado-height glazing Fanlight glazing All the glazing variations can be combined with the LVTsystem solid partition. Joints and connections: Joints: Concealed in the vertical shadow gaps (along the entire room height) there is a hook-on system attached for shelf brackets. Joint sealant: Plastic profiles are used on the floor and ceiling channels and on the stud profile. Connections: Recessed floor, ceiling and wall junctions. Field of application: Offices Industrial and factory rooms Training and research rooms Technical Data Fireproofing: F0 / G30 / F30 as per DIN 4102 EI30 as per EN 1364-1 Static requirements: Installation area type 1 and 2 Non-supporting partition as per DIN 4103 Height up to max. of 3 500 mm Axial width up to max. of 1 500 mm Weight: 20 – 60 kg/m² for fully glazed partition Joint width: 6 / 8 mm Partition thicknesses: 100 and 125 mm (19 mm panelling) 89 and 100 mm (13 mm panelling) Glass thicknesses: variable Glass panes with integrated shutter are possible depending on partition thickness, also in the fire protection Applicable standards: DIN 18202, DIN 1249, DIN EN ISO 12543 Customized solutions are possible on request! Soundproofing: up to 46 dB Rw,P as per DIN EN ISO 140-03 Subject to technical changes also without notification. F12 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Hook-on Aluminium Frame Fig. 28 Vertical section of glazed partition with jalousie Fig. 29 Vertical section of aluminium door frame Fig. 30 Horizontal section of linear modular system Fig. 31 Horizontal section of aluminium door frame Subject to technical changes also without notification. F13 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Hook-on Aluminium Frame Fig. 32 Horizontal section of 90°-corner Fig. 33 Horizontal section of T-junction on module via glass facade connection Fig. 34 Horizontal section of wall connection Fig. 35 Horizontal section of stop end Fig. 36 Vertical section of dado connection Fig. 37 Horizontal section of T-junction on linear modular system Subject to technical changes also without notification. F14 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-fronted double-glazing System 125 Fig. 38 Fig. 39 Subject to technical changes also without notification. F15 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-fronted double-glazing System 125 Fig. 40 System description A glazed partition consisting of two aluminium frames with integrated panes, which hook into the system studs. The panes are held in place by a frame at the perimeter with a visible width of 35 mm. Substructure: This consists of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Glazing: This consists of a two-piece glazing element into each of which a pane fastens. The visible width of the frame at the perimeter is 35 mm. The two frames hook into a postand-beam construction. Glass thicknesses are possible from 6 – 9 mm. Design options: Full glazing Dado-height glazing Fanlight glazing possible with shutters for every option All the glazing variations can be combined with the LVTsystem solid wall. Joints and connections: Joints: Concealed in the vertical shadow gaps (along the entire room height) there is a hook-on system attached for shelf brackets. Joint sealant: Plastic profiles are used on the floor and ceiling channels and on the stud profile. Connections: Recessed floor, ceiling and wall junctions. Field of application: Offices Industrial and factory rooms Training and research rooms Static requirements: Installation area type 1 and 2 Non-supporting partition as per DIN 4103 partition height up to max. of 3 500 mm Glazing height up to max. of 3 000 mm Glazing width up to max. of 1 400 mm Weight: 35 – 45 kg/m² for fully-glazed partition Joint width: 6 / 8 mm Partition thicknesses: 100 mm and 125 mm (19 mm panelling) 100 mm (13 mm panelling) Applicable standards: DIN 18202, DIN 1249, DIN EN ISO 12543 Technical Data Customized solutions are possible on request! Fireproofing: F0, F30 (as per DIN 41 02) as a three piece glazing EI30 / EI60 as per EN 1364-1 as a three piece glazing Soundproofing: up to 47 dB Rw,P as per DIN EN ISO 140-03 Fully-glazed partition Subject to technical changes also without notification. F16 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-fronted double-glazing Fig. 41 Vertical section of glazed partition with jalousie Fig. 42 Vertical section of aluminium door frame Fig. 43 Horizontal section of linear modular system Fig. 44 Horizontal section of aluminium door frame Subject to technical changes also without notification. F17 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-fronted double-glazing Fig. 45 Horizontal section of 90°-corner Fig. 46 Horizontal section of T-junction on module via glass facade connection Fig. 47 Horizontal section of wall connection Fig. 48 Horizontal section of stop end Fig. 49 Vertical section of dado connection Fig. 50 Horizontal section of T-junction on linear modular system Subject to technical changes also without notification. F18 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-surface bonded double-glazing System 137 Fig. 51 Fig. 52 Subject to technical changes also without notification. F19 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-surface bonded double-glazing System 137 Fig. 53 System description A glazed partition consisting of two aluminium frames with panes glued on, which hook into the system studs. The panes are flush with the aluminium frame so that only the 20/32-mm adhesive surface behind is visible. Substructure: This consists of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Glazing: This consists of a two-piece aluminium frame onto each of which a pane is glued. With this flush design the visible width of the adhesive surface is 20 mm, it being possible for the profiled section to be as wide as 32 mm for ceiling junctions (tolerance compensation). The two frames hook into a post-and-beam construction. Glass thicknesses are possible from 6 – 8 mm. Bonding: The proved structural glazing technology by Dow Corning had been used for the bonding. This bonding technology guarantees highest reliability and longevity. Design options: Full glazing Dado-height glazing Fanlight glazing possible with shutters for every option All the glazing variations can be combined with the LVTsystem solid partition. Joints and connections: Joints: Concealed in the vertical shadow gaps (along the entire room height) there is a hook-on system attached for shelf brackets. Joint sealant: Plastic profiles are used on the floor and ceiling channels and on the stud profile. Connections: Recessed floor, ceiling and wall junctions. Field of application: Offices Industrial and factory rooms Training and research rooms Technical Data Fireproofing: F0, F30 (as per DIN 41 02) as a three-piece glazing EI30 / EI60 as per EN 1364-1 as a three piece glazing Soundproofing: up to 46 dB Rw,P as per DIN EN ISO 140-03 fully-glazed partition Static requirements: Installation area type 1 and 2 Non-supporting partition as per DIN 4103 Partition height up to max. of 3 500 mm Glazing height up to max. of 3 000 mm Glazing width up to max. of 1 500 mm Weight: 35 – 40 kg/m² for fully-glazed partitions Joint width: 6 / 8 mm Partition thicknesses: 100 and 125 mm (19 mm panelling) 100 mm (13 mm panelling) Adhesive: Type: following ETAG 002, using structural glazing system Temperature resistance: -50° C to +150° C Colour: Light-grey Applicable standards: DIN 18202, DIN 1249, DIN EN ISO 12543 Customized solutions are possible on request! Subject to technical changes also without notification. F20 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-surface bonded double-glazing Fig. 54 Vertical section of glazed partition with jalousie Fig. 55 Vertical section of aluminium door frame Fig. 56 Horizontal section of linear modular system Fig. 57 Horizontal section of aluminium door frame Subject to technical changes also without notification. F21 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition – flush-surface bonded double-glazing Fig. 58 Horizontal section of 90°-corner Fig. 59 Horizontal section of T-junction on module via glass facade connection Fig. 60 Horizontal section of wall connection Fig. 61 Horizontal section of stop end Fig. 62 Vertical section of dado connection Fig. 63 Horizontal section of T-junction on linear modular system Subject to technical changes also without notification. F22 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Slim Line Glazing System 140 Fig. 64 Fig. 65 Subject to technical changes also without notification. F23 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Slim Line Glazing System 140 Fig. 66 System description Glazing featuring frameless design with a vertical covering profiled section and visible width of 60 mm. Substructure: This consists of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Glazing: Single-pane glazing with single pane or thermopane glazing. Design options: Dado-height glazing Fanlight glazing All the glazing variations can be combined with the LVTsystem solid wall. Field of application: Offices Industrial and factory rooms Training and research rooms Technical Data Fireproofing: F0 / G30 as per DIN 4102 For international certifications, see Fire Protection Overview Soundproofing: up to 46 dB Rw,P as per DIN EN ISO 140-03 Static requirements: Installation area type 1 and 2 Non-supporting partition as per DIN 4103 Height up to max. of 3 500 mm Axial width up to max. of 1 500 mm Weight: 40 – 60 kg/m² Joint width: 6 / 8 mm (on dado-height) Partition thicknesses: 100 and 125 mm (19 mm panelling) 89 and 100 mm (13 mm panelling) Glass thicknesses: variable Glass panes with integrated shutter are possible depending on partition thickness, also in the fire protection. Applicable standards: DIN 18202, DIN 1249, DIN EN ISO 12543 Customized solutions are possible on request! Subject to technical changes also without notification. F24 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Slim Line Glazing Fig. 67 Vertical section of fanlight glazing Fig. 68 Vertical section of steel door frame Fig. 69 Horizontal section of linear modular system Fig. 70 Horizontal section of linear modular system Subject to technical changes also without notification. F25 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Glazed Partition with Slim Line Glazing Fig. 71 Horizontal section of 90°-corner Fig. 72 Horizontal section of T-junction Fig. 73 Horizontal section of wall connection Fig. 74 Horizontal section of stop end Fig. 75 Vertical section of wall panel above glazing Subject to technical changes also without notification. F26 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Surfaces for Partitions and Wall Cladding Wooden panel, perforated sound-absorbing / sound-deadening Fig. 76 System description Our partitions and our wall claddings can be equipped with different surfaces. This wooden panel is constructed such that it can be used in combination with nearly all systems. With different stampings and superstructural parts this panel can be used for rooms with high acoustic requirements. Structure: Consisting of a top layer and a bracing wooden frame with an acoustic panel inside. For sound absorbing demands this panel can be fitted out with additional plasterboard inlays. Surface: Veneer Laminated plastic Lacquering Possible hole patterns: Form: round, quadratic, square Size: 5 and 8 mm (Standard) Special features: - sound-absorbing - sound-deadening Field of application: In LVT Solid Partitions, dado-height glazing and wall claddings Offices Industrial and factory rooms Training and research rooms Sound absorption: Assessed sound absorption value as per ISO 11654 αw = 0,50 Hole dimension 6 mm Hole percentage 11% Technical Data Fireproofing: F0 Soundproofing: 49 dB Rw,P as per DIN EN ISO 140-03 with Solid Partition Systems 100 mm each one- sided and two- sided installed Weight: 10 – 15 kg/m² (wall panel) Dimensions: max. b x h = 1200 mm x 3000 mm Panel thickness: 19 mm Subject to technical changes also without notification. F27 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Surfaces for Partitions and Wall Cladding Surfaces of Metal Wall Panels Coil coating Powder coating A metallic base material is provided with an organic coating material in a continuous process (coil coating). Electrostatically charged polyester-based powder particles are blown onto an earthed base material. Afterwards the coating film is cross-linked at approx. 180° C. Base material: Hot-dip galvanized (Sendzimir-galvanised) sheet metal with a zinc deposit of approx. 7 µm = 100 g/m²; with zinc deposited on both sides Coating: Priming coat and coat of finishing enamel with an average coat thickness of approx. 25 µm. Coat of protective enamel on reverse side of 7 µm -10 µm thick. Surface RAL 9010 according to Lindner Plain Gloss rate in units Approx. 24 E according to Gardner DIN 67 530 60° measuring angle Degree of reflection as a percentage Approx. 82 % In addition to this, the visible surface is provided with an approx. 120 µm thick, pull-off protective sheeting as protection during production and installation. Base material: Electrolytically galvanised thin-gage sheet metal with a zinc deposit of 2.5 µm = 36 g/m², with zinc deposited on both sides Coating: Coat of finishing enamel covering the base evenly. Gloss rate in units Degree of reflection as a percentage RAL 9010 according to Lindner Plain Approx. 18 EH according to Gardner DIN 67 530 60° measuring angle Approx. 82 % RAL 9006 according to Lindner Plain Approx. 57 EH according to Gardner DIN 67 530 60° measuring angle Approx. 47 % Surface Properties: - An even coating thickness and thus also an even appearance. - Very good corrosion protection through use of a zinc/ enamel synergy effect. - Edges of cuts are protected against corrosion through the protective cathodic effect of zinc. Properties: - Very thick coat of enamel, providing good technical properties. - Edges of cuts are also coated as a result of the manufacturing process and thus also protected against corrosion. - Very good protection against corrosion through use of a zinc/enamel synergy effect. - Environmentally suitable, as the coating process is solvent-free. Fig. 77 Fig. 78 Illustration of the structure of the coating of coil-coated steel sheet Visible side Illustration of the structure of the coating of powder-coated steel sheet Visible side Pull-off protective sheeting, approx. 120 µm Coat of finishing enamel, approx. 25 µm Zinc layer, approx. 7 µm Steel core, 0.60-1.00 mm Zinc layer, approx. 7 µm Coat of finishing enamel covering the base evenly Zinc layer, approx. 2.5 µm Steel core, 0.60-1.00 mm Zinc layer, approx. 2.5 µm Coat of protective enamel, 7-10 µm Subject to technical changes also without notification. F28 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Doors T0 Door element in LVT Partition Fig. 79 Fig. 80 Aluminium door frame Steel door frame A slim aluminium door frame with decorative rebate and a panel width of only 35 mm. This frame is delivered with door leaves in various designs of solid chipboard or glass. Steel door frame in standard design with panel width of 40/55 mm. This frame can be delivered with a wide variety of rebates and wall thicknesses. It can also be integrated in any LVT partition system. Technical Data: - 6 and 8 mm wall joints possible - For revolving doors - With decorative rebate - Panel width of 35 mm Technical Data: - Wall joints from 6-8 mm (standard) - For revolving doors - Panel width of 40/55 mm (standard) - Wide variety of rebates possible Door leaf options: Wooden door leaf: Flush closing and with rebate Glass door leaf: Clear glass and white satin-finish Steel sheet door leaf: flush closing Aluminium frame door leaf Door leaf options: Wooden door leaf: Flush closing, with rebate, flush with reveal rebate, double-rebate opening action Steel sheet door leaf: flush closing, flush with double rebate Glass door leaf Aluminium frame door leaf Special feature: For example: Closing equipment, switch in door frame Special feature: For example: Closing equipment or switch in door frame Subject to technical changes also without notification. F29 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Doors T0 Door element in LVT Partition Tubular frame door leaf, aluminium Fig. 81 System description Tubular frame door, which consists of aluminium and has the smallest possible visible width. This door leaf is available with glass panes which have different thicknesses. For soundproofing it is possible to integrate an automatic door seal. Technical Data Fireproofing: F0 Soundproofing: 32 dB Rw,P according to DIN EN ISO 140-03 in aluminium door frame Thickness of door leaf: 40 mm / 56 mm Dimension of tubular frame: Sidewise an on top: 86 mm On bottom: 111 mm Possible glass thickness: 6, 8, 10 and 24 mm Fig. 82 Flush at the side of the hinge Fig. 83 Flush at corridor side Subject to technical changes also without notification. F30 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Doors T0 Door element in LVT Partition Aluminium door frame with glass door leaf flush with surface on both sides Fig. 84 Fig. 85 System description Technical Data Aluminium door frame flush closing with double rebate and a panel width of 35/65 mm. The glass door leaf consists of a aluminium frame construction with safety glass panes glued on. The door element is equipped with hinges for 3D adjustment. Fireproofing: F0 Substructure: Consisting of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Bonding: The proved structural glazing technology by Dow Corning had been used for the bonding. This bonding technology guarantees highest reliability and longevity. Soundproofing: 37 dB Rw,P as per DIN EN ISO 140-03 Partition thicknesses: 100 mm (19 mm panelling) Dimensions: Inside frame size Height: max. 2 414 mm Width: max. 1 264 mm Technical Data: - Panel width of 35/65 mm - Door leaf thickness: 100 mm - 6 and 8 mm safety glass Adhesive: Type: following ETAG 002, using structural glazing system Temperature resistance: -50° C to +150° C Colour: Light-grey Subject to technical changes also without notification. F31 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Doors T0 Door element in LVT Partition Sliding Door Fig. 86 System description A sliding door integrated into the partition elements, with pass-through design to match the partition elements. This door element is possible up to the room height in several variations. It can be installed in partition elements and in double glazing systems. When opened, the door itself disappears into the void of the wall. Options: Solid sliding door element: Divided,with fanlight, roomhigh Glass sliding door element: In clear glass or white satinfinished, divided, room-high Technical Data Dimensions: - Partition thickness 100 mm - Width of solid sliding door element 1 100 mm - Width of glass sliding door element 1 200 mm - Clear width 950 mm - Height of element with fanlight or divided 3 400 mm - Height of element, sliding door room-high 3 100 mm - Panel width 35 mm Installation characteristics: - For 13 and 19 mm panelling - 6 and 8 mm wall joint possible - Sliding door can be used on the right-hand or left-hand side - Next to the sliding door in the „opening direction“ at least a 1 000 mm wide element is necessary - double leaf possible Subject to technical changes also without notification. F32 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Doors T30-Türelement in LVT-Wand F30 / F90 T30 Door element in F30 / F90 LVT Partition Fig. 87 System description Technical Data A fireproof door in a single-leaf design optionally with wooden or steel door frame and wooden door leaf for installation in LVT partitions with leastwise F30 requirement. Fireproofing: T30 as per DIN 4102 in F30 / F90 LVT partition Substructure: The studs, beams and hinges are made of galvanised steel tubes and are roll-formed or edged steel sheet profiled section elements. Design options: Door frames: - wooden door frame - steel door frame Design of door leaf: - Flush - With rebate - Full door - Door with window for light Soundproofing: up to 45 dB Rw,P as per DIN EN ISO 140-01 Static requirements: max. partition height: 3 500 mm Partition thicknesses: 100 and 125 mm (19 mm panelling) 100 mm (13 mm panelling) Dimensions: Clear height: max. 2 200 mm Clear width: max. 1 150 mm Panel widths: 50 / 65 mm (wooden door frame) 45 / 60 mm (steel door frame) Multiple functions: - Smoke control as per DIN 18 095 - Air-conditioning category to III as per DIN EN 79 Subject to technical changes also without notification. F33 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Doors T30/RS Door Element in F90 LVT Partition Steel Door Frame with Steel Door Leaf Fig. 88 System description Door element possible with fire protection and smoke protection, single leaf, with steel door frame and steel door leaf for installation into LVT partition with appropriate fire protection requirements. The door leaf is manufactured as butt-jointed type. Substructure: The studs, beams and hinges are made of galvanised and roll-formed or folded steel sheet profiled section elements. Technical Data Fireproofing: T30 as per DIN 4102 in F90 LVT partition Smoke protection (as per DIN 18095): T0 as per DIN 4102 in F30 LVT partition d ≥ 100 mm T30 as per DIN 4102 in F90 LVT partition Static requirements: Max. partition height: 3 500 mm Partition thicknesses: 100 and 125 mm (19 mm panelling) 89 and 100 mm (13 mm panelling) Dimensions: Inside frame size min. ZFM b x h = 670 x 1 710 mm max. ZFM b x h = 1 020 x 2 110 mm Panel widths 55/40 mm (standard) 60/45 mm (with electric door opener) Subject to technical changes also without notification. F34 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Installation System for Partition Systems Gira ITS 30 The installation system Gira ITS 30 provides an installation with great flexibility and functionality in commercial buildings. Fig. 90 Gira ITS 30 brings different functions and devices of electrical installation, bus technology or name plates together, in one busbar: It is integrated in a 30-mm wide joint between the studs of the partition system. The joint serves as space for the installation of power supply lines and control lines, which come out of the ceiling or out of the floor. This system is also integrated in an LVT aluminium door frame. The combination Gira ITS 30 in LVT aluminium door frame with a visible width of 35 mm has been developed especially for glazing systems to hold the small look of the system. For the installation of elements of building services, the busbar has three fixed installation ranges in dif-ferent heights: 300 mm. 1050 mm and 1500 mm. Fig. 91 Moreover name plates of the guidance system COM.form of Mabeg company can be installed on any height of the busbar. Gira ITS 30 is suited for installation in front of glass: The small busbar and LVT aluminium door frame replace the aluminium blind next to the door frame or between glazings and increase the quantity of glass. This leads to more transparency in the building. Fig. 89 Fig. 92 Subject to technical changes also without notification. F35 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Accessories Blinds for Glazing Systems Fig. 93 All Lindner glazing systems can be combined with commercially available blinds for indoors. This makes the extensive range of products from various manufacturers available to you along with a wide variety of options. Field of application: Blinds to provide both shade and privacy in indoor areas. These can be fastened on the frame outside the pane (e.g. with non-bearing frames) or even inside the glazing element (e.g. in double glazing). Operation: - Electric motor - Cord / Reversing motor - Cord / Rod - Chain - Crank - Knob Upper rail: Roll-formed, coated steel channel section, 25 x 24 mm; option: extruded, powder-coated circular profiled section, D = 40 mm Slats: Aluminium band, 16, 25 or 35 mm wide, special alloyed, highly flexible, slightly curved; option: partially perforated Lower rail: Extruded aluminium profiled section element, 18 x 12, 27 x 12 or 35 x 12 mm, depending on width of slats, powdercoated according to RAL. Guide cord and pull-up cord: Made of long-lasting, high-strength polyester. Side guides: Available on request made of polyamide-sheathed steel wire strands Structural limits: Min. width: 340 mm Max width: 2 500 mm Min. height: 2 500 mm Max area: 4.0 m² Options: Vertical blinds with 63-mm wide slats Overall height: up to 3 000 mm Subject to technical changes also without notification. F36 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Accessories Blinds inside thermopane glazing Fig. 94 Field of application: Blinds to provide both shade and privacy in indoor areas. These are built hermetically into the insulating glass and thus are protected against soiling and damage from without, and take less space. Operation: - Electric motor - Pull cord - Crank Upper rail: Upper roller box made of extruded aluminium, stoveenamelled Slats: Aluminium slats, with priming coat and finishing coat of enamel, 15 mm wide, slightly curved. The slats are available in various colours, aluminium-plated and reflective. Pull-up cord: Pull cord made of textile cord with edge guard, UV-radiation guard and scalelike sheath to protect against sunlight. Side guides: Guide cords made of Terylene with UV-radiation guard Structure of the panes: Insulating glass is possible with various thicknesses and combinations of: mirror glass, laminated safety glass, tempered safety glass, casting-resin glass, ornamental glass and heat protection glass. Structural limits: Min. width: 400 mm Min. height: 300 mm Max width: 2 200 mm Max. height: 3 800 mm Subject to technical changes also without notification. F37 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Accessories Tapered Façade Connection Fig. 95 System description Technical Data Tapered façade connection in various designs make it possible to connect to exterior façades using slim supports for LVT partitions. Fireproofing: up to F90 is possible. Substructure: This consists of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Design options: - either matching partitions or - fully-glazed Field of application: Connection of LVT partition systems to exterior façades using slim supports. Soundproofing: up to 51 dB Rw,P as per DIN EN ISO 140-03 With visible width of 241 mm and wall thickness of 43 mm; F0 fireproofing Measurement for the tapered façade connection only Dimensions: Variable, but limited for fireproof and soundproof variations Surfaces: - Chipboard - Metal - Aluminium - Plasterboard Subject to technical changes also without notification. F38 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Great Ways to Organise Your Office Hook-on Items and Office Accessories Here are a few examples showing the possibilities opened up by Lindner office and partition systems. Fig. 101 There are various furnishings, examples of crosswise organisation, filing systems and hook-on cabinets, all geared to our system as shown. Surface of the hook-on elements: Anthracite Fig. 96 A4-Tray, crosswise Fig. 102 Fig. 97 A4-Tray, lenghtwise Fig. 98 Desk set Fig. 103 Fig. 99 File board Fig. 100 Picture hook (stainless steel) Subject to technical changes also without notification. F39 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. LVT Partition for Inspection Chambers F30 LM 500 Fig. 104 System description Technical Data A completely removable partition for inspection chambers, which depends on the technique of removable partitions. It serves as an alternative to conventional inspection chambers of dry mortarless construction, which have to be equipped with expensive flap lids or fire protection doors. Fireproofing: F30 as per DIN 4102 Substructure: Consisting of folded and roll-formed steel sheet profiled section elements, galvanised or coated. Panelling: Sandwich element system with hook-on system and metal panels Joints and connections: Joint sealant: Plastic profiles are used on the floor and ceiling channels and on stud profile elements. Connections: Recessed floor, ceiling and wall junctions Static requirements: Non-supporting partition as per DIN 4103 Height up to max. 3 000 mm Axial width up to max. 1 625 mm Weight: 45 kg/m² Joint width: Vertical: 4 – 8 mm (Standard) Horizontal: 4 – 15 mm Partition thickness: Approx. 90 mm Special features: - completely removable - inspection-friendly handling for later installations - easy dismantlement and reassembly Subject to technical changes also without notification. F40 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Instructions for Ordering, Installation and Use Storage & Transport Instructions - Load and unload delivery units with a forklift or crane (lifting capacity of at least 1.5 t). Fig. 105 A delivery unit of wall panels - Transport inside the building using pallet lifts. - Any interim storage should be in temperature-controlled rooms which are protected against the weather. - In cases of storage lasting for long periods of time, cover the stacks of panels to avoid soiling. - Avoid fast heating up or cooling down of storage rooms. - Protect the corners of the panels against getting damaged. Climatic Conditions for LVT Wall Panels It is necessary to comply with the humidity restrictions to assure the dimensional and geometrical accuracy of the LVT partitions. Fig. 106 Max. humidity in the air in g/m³ Like all materials used in construction, plasterboard panels, which are glued onto the reverse side of LVT wall panels, are subject to linear expansion when affected by temperature or moisture. 25 20 15 ted mit 10 er ep ng Ra 80 % 5 40 % 0 0 5 10 15 20 25 30 Air temperature in °C Subject to technical changes also without notification. F41 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Instructions for Ordering, Installation and Use Installation Instructions Fasten the floor and ceiling tracks (1) & (2) to the local conditions, putting ceiling tape (3) in between and stick on the system seals (4). Screw the suspension brackets (9) into this regular grid with the special screws (10). Joint widths of 0-12 mm can be selected over the clearance of the drilled holes (11). Fig. 107 The nib (12) is an aid for insertion when hooking on the panelling. Fig. 108 3 8 2 9 11 . 10 64 1 4 12 Adjust the main item of the system, the LVT stud (5) in the tracks mentioned above using a height-adjustment bracket (6) and align the axial dimension and height. Draw the joint seal (7) into the groove in the stud. Finally, hook the wall panels provided with the suspension brackets into one side of the post-and-beam structure. After putting the insulation material in, hook on the other side of the partition. Fig. 109 5 7 Note: To hook on the wall panels, it is necessary to lift them. Horizontal joints should therefore be planned with a joint width of at least 12 mm in case the wall panel beneath has to be removed. 6 The prefabricated wall panels are provided with regular drillings on the reverse side of the panels. Clearance = 64 mm (8). min. of 12 mm Fig. 110 Wall panel or glazing frame Wall panel Subject to technical changes also without notification. F42 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Standards and Regulations Table of Standards Standard Designation Issued DIN 4102 Behaviour in fire of building materials & building components Sep 1977 DIN 4103 Non-load bearing interior partition Jul 1984 DIN 4109 Soundproofing in building construction Nov 1989 DIN 1249 Plate glass in the building trade Feb 1980 DIN EN ISO 12 543 Glass in the building trade Aug 1998 DIN 18 165 Fibrous insulating materials for the building industry Mar 1987 DIN 18 202 Tolerances in building construction Apr 1997 DIN 18 361 Glazing work Oct 1979 DIN 18 257 Safety door signs Mar 1991 DIN 68 100 Tolerance system for woodworking Dec 1984 ETAG 002 Guideline for the European Technical Certification for Glued Glass Constructions Jul 1998 System-specific Properties - Consultancy, supervision of the real estate, and installation should all be carried out by specially trained qualified personnel - It is also possible to rearrange this partition at any time after installation (e.g. exchanging a full element for a glazed element). - The system has a sandwich-type construction. - Linear or grid construction (preferred axial measurements: 800-1000 mm) - Uniform partitions thickness (standard: 100 mm) - Standard design up to a height of 3 200 mm - Rw,p soundproofing rating up to 54 dB - Fireproofing: - F30-design - F30-glazing - F90-design - G30-glazing - G90-glazing - T30-door element, single-leaf - Types of glazing: - Double glazing - Glazing flush with surface - Single glazing, outside and centre - Insulation glazing, centre - It is possible to install cables and lines inside these partitions, both horizontally and vertically. - Later installations can be carried out at any time (by removing one element of the wall panel). - Surface options: Melamine resin coating Laminated sheet Real wood veneer Metal Plasterboard - Recessed floor and ceiling connection in the standard design - Subsequent deliveries are possible of elements of the same design as in the initial equipping. Subject to technical changes also without notification. F43 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Standards and Regulations Static requirements Excerpt from DIN 4103 - Non-load bearing interior partitions (July 1984) Installation Area Types Static Loads Installation Area Type 1: - For low numbers of people - Examples: Flats, hotel rooms, offices, hospital rooms and other rooms used similarly, including their corridors Bending limit for load-bearing capacity of the partitions compared with static loading - Acting horizontal linear load (working load), primarily static, with points of application 0.9 m above the base of the partition (Fig. 1). Installation Area Type 1: p1 = 0,5 kN/m Installation Area Type 2: p2 = 1,0 kN/m - Light loading by brackets: Installation Area Type 2: - For high numbers of people - Examples: Assembly rooms, classrooms, auditoriums, exhibition and sales rooms and other rooms used similarly - Partitions between rooms with a difference in the height of the floors ≥ 1.0 m Vertical linear load of 0.4 kN/m (Fig. 2) Resistance of the partitions against impact-like loading (Fig. 3) Proof: - Impact of a human body (soft impact) - Sack of glass beads weighing 50 kg - Damage to the partition is allowed, but the following conditions have to be met: The partitions must be pulled out of their fastenings. Partition elements that might seriously injure people must not fall off. The entire thickness of the partitions must not be punctured. General requirements Partitions have to: - Resist static (primarily static) and impact loads, as might occur when they are used - Be able to assume loads applied to their surface in addition to their own weight, including any plaster or other possible facing, and transfer such to other supporting constructional elements, such as walls and ceilings. - Transfer light loading by brackets - In cases of loading by wind power, such as in industrial buildings with large doors frequently open (supporting documents 4.2-4.4 of DIN 4103), keep a supporting document for half the dynamic pressure as per DIN 1055, Part 4. Partitions can: - Assume functions for securing against crashing Working load (primarily static) -Fig. 1 Loading by brackets - Fig. 2 Impact-like loading - Fig. 3 £ 300 1650 0.4 kN/m (= 40 kg/m) Wall length Room heigt 50 k g = £ 300 Room heigt Installation Area Type 2 (Large numbers of people) 1.0 kN/m (= 100 kg/m) Pressure 50 kg 0.5 kN (= 50 kg) = 900 Horizonal linear loadt Room heigt Traction Installation Area Type 1 (Low numbers of people) 0.5 kN/m (= 50 kg/m) Subject to technical changes also without notification. F44 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. GDL – IGG Fully-Glazed Partition System LW600 Fig. 111 Subject to technical changes also without notification. F45 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. GDL – IGG Fully-Glazed Partition System LW600 Fig. 112 System description A fully-glazed partition flush with surfaces, in which the profiled section elements are integrated between two panes so as not to be visible, without any projecting or visible parts on the surface of the glass. Clamping of the edges of the glass in a connection at the margins makes the technology completely disappear visibly. This full glazing is constructed in row assemblies. Substructure: The substructure, including the glass retaining frame, is made of anodised aluminium. Glazing: Thermopane glazing, 2 x 6 mm tempered safety glass (standard) Field of application: Office and corridor partitions with automatic and manual stop doors and swinging doors. prepared for a shelving system Door Closer: Swinging doors with floor closer Stop door with top door closer Both designs can also be combined with automatic system for opening and/or closing. Technical Data Fireproofing: F0 Partition thickness: 39 mm Soundproofing: 35 dB Rw,P as per DIN 4109 Weight: Fixed panel elements: 2 x 6 mm tempered safety glass = 34 kg/m² 2 x 8 mm tempered safety glass = 44 kg/m² Stop doors and swinging doors: Thickness of door leaf: approx. 40 mm Max. weight of door leaf: 120 kg per door leaf Static requirements: Installation area type 1, non-load bearing partition as per DIN 4103 for the dimensions w x h = max 1250 x 2800 mm Subject to technical changes also without notification. F46 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. GDL – IGG Fully-Glazed Partition Fig. 113 Vertical section of ceiling connection Fig. 114 Horizontal section of linear modular system Fig. 115 Vertical section of floor connection Fig. 116 Horizontal section of wall connection Fig. 117 Horizontal section of door frame Fig. 118 Vertical section of door frame with door closer on the top side Subject to technical changes also without notification. F47 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Fully-Glazed Partitions Lindner Fully-Glazed Partition System LW620 Fig. 119 Subject to technical changes also without notification. F48 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Fully-Glazed Partitions Lindner Fully-Glazed Partition System LW620 Fig. 120 System description Technical Data A fully-glazed partition without any vertical supporting members – only horizontal fastening tracks on the floor and ceiling. Fireproofing: F0 Substructure: Aluminium Field of application: Corridor partitions with manual sliding doors which are moveable in front of the partition or revolving doors with infill strips on both sides. Element connection: Silicon Dry silicon T-section Soundproofing: Depends on the design option Partition height: Up to max. 2 800 mm Glass thicknesses: 10 and 12 mm for tempered safety glass Weight: Sliding door: Max weight of leaf: 100 kg Subject to technical changes also without notification. F49 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Fully-Glazed Partitions Lindner Fully-Glazed Partition Fig. 121 Vertical section of ceiling connection with sliding door Fig. 122 Horizontal section of glazing next to glazing Fig. 123 Horizontal section of ceiling connection with sliding door Fig. 124 Horizontal section of wall connection Fig. 125 Vertical section of aluminium door frame Fig. 126 Horizontal section of aluminium door frame with post cap element Subject to technical changes also without notification. F50 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Timber Framework Partition System LW640 Fig. 127 Fig. 128 Subject to technical changes also without notification. F51 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Timber Framework Partition System LW640 Fig. 129 System description: Technical Data A partition with a timber framework method of construction for interior areas. This partition is delivered with prefabricated elements. The individual elements can later be exchanged without removing the adjacent elements. Fireproofing: F0 Substructure: This is made of derived timber products. Panelling: Wall Shell: Frame: Surface: Glazing: 16 mm, MDF 38 mm, MDF Any type of wood desired mono glass pane Connections: Recessed floor, ceiling and wall connections Design options: Solid partition fully-glazed partition Special features: - Inspection-friendly handling for later installations due to wall shells being removable on one side - Replacement of individual elements Soundproofing: Depends on the design option Static requirements: Installation area type 1 and 2 Non-supporting partitions as per DIN 4103 Height: 2 700 mm Axial width: 1 250 mm for fully-glazed partitions with laminated safety glass 12 mm Weight: 34 – 38 kg/m² for solid partitions 20 – 35 kg/m² for fully-glazed partitions Joint width: 15 mm Partition thicknesses: 100 mm Field of application: Offices Subject to technical changes also without notification. F52 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Timber Framework Partition Fig. 130 Vertical section of solid partition Fig. 131 Vertical section of glass partition Fig. 132 Horizontal section of linear modular system of solid partition Fig. 133 Horizontal section of linear modular system of glazing Subject to technical changes also without notification. F53 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Timber Framework Partition Fig. 134 Horizontal section of wall connection on solid partition Fig. 135 Vertical section of door frame Fig. 136 Horizontal section of wall connection on glazing Fig. 137 Horizontal section of solid partition next to glazing Fig. 138 Horizontal section of door frame Subject to technical changes also without notification. F54 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Fully-Glazed Partition System LW650 Fig. 139 Subject to technical changes also without notification. F55 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Fully-Glazed Partition System LW650 Fig. 140 System description Fully-glazed partition, flush double glazing. The glass panes are installed to the vertical system stud (with glass holding elements on the side). Substructure: Consisting of aluminium profiles. The glass holding elements are made of stainless steel. Door elements: Offset hung door element in rebated frame (with door frame 35/35 mm) and a glazed door leaf (10 mm) with bearing. Field of application: Office partitions and corridor partitions Technical Data Fireproofing: F0 Soundproofing: According to type Static requirements: Installation area 1 Non-load bearing partition as per DIN 4103 Height up to max. of 3,300 mm Axial width up to max. of 1,500 mm Weight: 35 – 40 kg/m² Joint width: 10 mm Partition thickness: 90 mm Subject to technical changes also without notification. F56 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Fully-Glazed Partition Fig. 141 Vertical section of glass wall Fig. 142 Vertical section of door element Fig. 143 Horizontal section of linear modular system Fig. 144 Horizontal section of door element Subject to technical changes also without notification. F57 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Lindner Safelite SL90 System LW660 F90 Fig. 145 Subject to technical changes also without notification. F58 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Lindner Safelite SL90 System LW660 F90 Fig. 146 NEU System description Technical Data Lindner Safelite SL90 is a kit for the construction of fireresistant glazings. The studs consist of special light metal profiles, which are glazed with fire- resistant panes. Thermal insulators serve as glass supporting bars and are covered with aluminium border bars. Visible width of the profiles is 70 mm. Its time- saving construction simplifies the handling and installation. Fireproofing: F90 as per DIN 4102 Substructure: Aluminium Design options: Fully glazed partition with transversal division Field of application: Corridor- and room partitions Soundproofing: 49 dB Rw,P as per DIN EN ISO 140-03 airbone sound insulation of glass pane Static requirements: installation area 1 and 2 non- supporting partition as per DIN 4103 heigth up to 4 000 mm axial width up to 1 435 mm Clear dimension b x h max. 1 365 x 2 165 mm Single panes applicable in landescape format Weight: 67 kg/m² weigth of glass pane Partition thickness: 121 mm Glass thickness: 45 mm Subject to technical changes also without notification. F59 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Lindner Safelite SL90 Fig. 147 Vertical section of glazing with cross division Fig. 148 Horizontal section of linear modular system Fig. 149 Horizontal section of wall connection Subject to technical changes also without notification. F60 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Team Panel System LW670 Fig. 150 Fig. 151 Fig. 152 Subject to technical changes also without notification. F61 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Team Panel System LW670 Fig. 153 NEU System description Technical Data Movable wall as a nonocoque construction, which can be installed between the storey ceilings without damaging the building. This system guarantees a great flexibility in dismantling and reassembling because of the fact that no dowelled joint is necessary. The studs consist of aluminium circular tubes, which are as high as the room. On the bottom and at the ceiling there are discs which are able to absorb the deflection of the ceiling. The installation of the panels depends on the height of the parapet and the height of the room. The panels are also available as sound-absorbent panels. Sound absorption: Itemisation for punched metal panel: Acoustical absorbance according to ISO 11 654 αw = 0,90 with an perforation rate ≥ 30 % Substructure: Consisting of folded steel sheet profiled section elements, galvanised or coated and aluminium circular tubes. Panelling: The panels are available for vertical or horizontal division. The surface of the panels can be real wood veneer, melamine resin, laminated plastic or metal. Options: covered with textile to use it as a pin board, cork linoleum, punched or slotted sound- absorbing panel. Field of application: Movable wall Room division Wall cladding Other surfaces, hole patterns and perforation rates are possible, as well as panelling with other products of manufacturers who produce sound absorbing wood panels. Excellent acoustical absorption in low- and medium-frequency ranges at a thickness of void of only 30 mm. Static requirements: For movable walls certificates according to DIN 4103 are necessary. But its impact load at a room height of 3 250 mm has been tested. Weight: 35 kg/m² Joint width: 10 mm Partition thickness: 110 mm Customized solutions are possible on request! Subject to technical changes also without notification. F62 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Team Panel Fig. 154 Vertical section Fig. 155 Horizontal section of linear modular system Fig. 156 Horizontal section of stop end Subject to technical changes also without notification. F63 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Plasterboard Partition Built-in Components in Plasterboard Partitions Fig. 157 Lindner is one of the largest end-users of plasterboard products. Lindner also works with external brands on request in addition to its own wide range of products such as: - F30 Glazing - G30 Glazing - G90 Glazing - F0 and F90 Access panels - Façade sword Subject to technical changes also without notification. F64 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Plasterboard Partition Lindner Akusto-Wand System description Fig. 158 With Lindner’s innovative Akusto studs, partitions can achieve a sound insulation to 54 dB – with conventional plasterboard soundproofing is achieved irrespective of boards’ manufacturer. plasterboard value of up panels. This the plaster- With the Akusto stud it is possible to construct partitions from a thickness of 75 mm while at the same time building higher than described in DIN 18 183 without reducing the standard axial measurement of 625 mm. For fireproofing, all commonly used systems can be executed with Akusto studs instead of CW-profiled section elements. Substructure This is made of folded or roll-formed steel sheet profiled section elements and is galvanised. The post-and-beam profiled section element is acoustically decoupled. Wall cladding The "Lindner Akusto" wall panel with double-layer panelling (Fireproofing and soundproof not allowed for) Width of section in mm Partition height in mm EB1 £ 3600 Partition height in mm EB2 75 100 £ 4500 £ 5500 £ 4500 £ 5500 50 – Installation Electrical installations can also be placed horizontally due to removable panels in the post-and-beam profiled section elements. Soundproofing „Lindner Akusto“ single-stud partition, with double-layer panelling Description System D Section h mm 100 125 150 150 mm 50 75 100 100 LGK 2.100.49 LGK 2.125.52 LGK 2.150.52 LGK 2.150.54 Official supporting documents sound static EB1/2 fire * ITA/LSW x x x x LGA h £ 5300 h £ 6400 h £ 7000 h £ 7000 MPA BS EB1 £ 4000 EB1 £ 5500 EB1 £ 6500 EB1 £ 6500 Thickness of Soundproofing DIN4109 insulation layer plasterboard Bbl.1/A1: 2003-9 panel > 8,5 kg Rw, R [dB] Rw, R [dB] mm 40 49 45 60 52 49 40 52 47 54 80 50 * EB2 on request Fire ratings Panelling Insulation layer Type Thickness Apparent density Thickness "Lindner Akusto" single-stud partition, with single-layer panelling F30 A GKF 12.5 30 40 "Lindner Akusto" single-stud partition, with double-layer panelling F30 A F60 A GKB 2 x 12.5 2 x 12.5 F90 A GKF F120 A 15 + 12.5 2 x 18 2 x 15 3 x 12.5 F180 A 25 + 12.5 30 40 40 30 50 100 40 40 50 100 50 100 50 100 40 80 60 40 40 40 80 60 80 60 80 60 Type Mineral wool insulating material, Building-Materials Class A d ³ 13 kg/m³ as per Inspection Certificate 4201/T2) for fireproofing or DIN 41024 Fireproofing Axial clearance a [cm] Supporting document 62.5 DIN 4102-4 and/or 015/01 Mer 3142/9181 62.5 DIN 41024and/or 015/01 Mer 3142/9181 Subject to technical changes also without notification. F65 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Lindner Fire Wall System LGK-530-BW Fig. 159 System description Technical Data Thinnest fire wall of dry and mortaless construction with Lindner-Akusto-studs. High sound insulation values can be achieved by a special way of construction and an additional steel sheet inlay. Fireproofing: Fire wall F90 as per DIN 4102 Partition F120 as per DIN 4102 Substructure Consisting of folded steel sheet profiled section elements, galvanised. The stud profile is installed in a special soundinsulating way. Static requirements: Installation area 1 and 2 Non- supporting partition as per DIN 4103 max. partition height 4 000 mm Partition thickness: 105 mm Subject to technical changes also without notification. F66 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 Steel Frame Glazing in Plasterboard Partitions System LGK-100-G30 Fig. 160 System description Technical Data Plasterboard glazing with steel framing and 50-mm visible width at the perimeter. This glazing can be carried out either with single or double glazing. Fireproofing: G30 as per DIN 4102 in plasterboard partitions for F30 Substructure: The floor and ceiling tracks and cross-section elements are made of folded and galvanised steel sheet profiled section elements. The studs and frames are made of galvanised steel tubes. Design options: Fanlight glazing Soundproofing: 41 dB Rw,P as per DIN 52210-03 Measurement of the glaszing system only Static requirements: Max. height: 3 500 mm Partition thicknesses: from 100 mm with panelling thickness of 2 x 12.5 mm Dimensions: Clear height/width 970 mm x 1770 mm whether vertical or horizontal format Subject to technical changes also without notification. F67 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 Steel Frame Glazing in Plasterboard Partitions Fig. 161 Vertical section of glass wall to GK-wall Fig. 162 Horizontal section of glazing next to glazing Fig. 163 Vertical section of dado connection Fig. 164 Horizontal section of glazing to GK-wall Fig. 165 Horizontal section of wal connection Fig. 166 Horizontal section of 90°-corner Subject to technical changes also without notification. F68 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G90 Steel Frame Glazing in Plasterboard Partitions System LGK-110-G90 Fig. 167 System description Technical Data Plasterboard glazing with steel framing but with only one visible vertical covering profiled section element with a 75-mm visible width. This can also be replaced by a plasterboard strip on request. The glazing can be carried out with single- or double-glazing. Fireproofing: G90 as per DIN 4102 in F90 plasterboard partitions Substructure: The floor and ceiling tracks and cross-section elements are made of edged and galvanised steel sheet profiled section elements. The studs and frames are made of galvanised steel pipes. Design options: Fanlight glazing Soundproofing: This depends on the structure of the panes Static requirements: Max. height: 3 500 mm Max. axial measurement: 2 075 mm Partition thicknesses: from 100 mm with panelling thickness of 2 x 12.5 mm Dimensions: Clear height/width Height of pane: max. 1 000 mm Width of pane: max. 2 000 mm Subject to technical changes also without notification. F69 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G90 Steel Frame Glazing in Plasterboard Partitions Fig. 168 Vertical section of GK-wall to glass wall connection Fig. 169 Horizontal section of wall connection Fig. 170 Vertical section of dado connection Fig. 171 Horizontal section of 90°-corner Fig. 172 Horizontal section of glazing next to glazing Fig. 173 Horizontal section of mono glazing Subject to technical changes also without notification. F70 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 / F30 Frameless Glazing in Plasterboard Partitions System LGK-120-G30 System LGK-120-F30 Fig. 174 F30 plasterboard partition with wood veneered wall panels an G30 fanlight Subject to technical changes also without notification. F71 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 / F30 Frameless Glazing in Plasterboard Partitions System LGK-120-G30 System LGK-120-F30 Fig. 175 System description Technical Data Frameless plasterboard glazing with only one vertical covering profiled section element with a 50-mm visible width. The glazing can be carried out with single- or double-glazing. Fireproofing: G30 / F30 as per DIN 4102 in F30 plasterboard partitions Substructure: The floor and ceiling tracks and cross-section elements are made of folded and galvanised steel sheet profiled section elements. The studs are made of galvanised steel tubes. Design options: Fanlight glazing Dado glazing (only F30) Soundproofing: 45 dB Rw,P as per DIN EN ISO 140-03 Measurement of the glazing system Static requirements: Max. height: 4 500 mm Max. axial measurement: 2 550 mm Partition thicknesses: from 100 mm with panelling thickness of 2 x 12.5 mm Dimensions: Clear height/width Height of pane: max. 1 200 mm Width of pane: max. 2 500 mm Customized solutions are possible on request! Subject to technical changes also without notification. F72 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 / F30 Frameless Glazing in Plasterboard Partitions Fig. 176 Vertical section of fanlight glazing Fig. 177 Vertical section of GK-wall to glass wall connection Fig. 178 Horizontal section of wall connection Fig. 179 Horizontal section of linear modular system Fig. 180 Horizontal section of GK-wall to glass wall connection Subject to technical changes also without notification. F73 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 / F30 Frameless Glazing in Plasterboard Partitions Fig. 181 Horizontal section T-junction on linear modular system via GKfacade connection Fig. 182 Horizontal section of T-junction on module via plaster board facade connection Fig. 183 Horizontal section of 90°-corner Fig. 184 Horizontal section of steel door frame Subject to technical changes also without notification. F74 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 High-performance Sound-Insulation Glazing in Plasterboard Partitions System LGK-140-G30 Fig. 185 System description Technical Data Plasterboard glazing in the form of a three-part element with panes glued on, which fit flush with the plasterboard partition. The element can be carry out as flush triple glazing with clear glass. Fireproofing: G30 as per DIN 4102 in F30 plasterboard partitions Substructure: The glazing frame is made of aluminium. The studs and beams are made of galvanised steel tubes. Design options: Fanlight glazing Soundproofing: 47 dB Rw,P as per DIN EN ISO 140-03 Measurement of the glazing system, d = 100 mm Static requirements: Max. height: 3 500 mm Max. axial measurement: 2 500 mm Partition thicknesses: from 100 mm with panelling thickness of 2 x 12.5 mm Dimensions: Height of element: max. 1 200 mm Width of element: max. 2 500 mm Customized solutions are possible on request! Subject to technical changes also without notification. F75 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. G30 High-performance Sound-Insulation Glazing in Plasterboard Partitions Fig. 186 Vertical section of ceiling connection Fig. 187 Vertical section of GK-wall to glass wall connection Fig. 188 Vertical section of glass wall connection Fig. 189 Horizontal section of linear modular system Subject to technical changes also without notification. F76 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. Façade Sword, High-performance Sound-Insulation LGK-500-F0 Axis of construction Fig. 190 System description Technical Data With plasterboard partitions and removeable partitions, the façade sword makes it possible to connect to exterior façades by using slim supports. With a total thickness of just ≥ 58 mm, soundproofing is achieved of Rw,P ≥ 52 dB. These elements are preassembled by the factory and are delivered to the construction site ready to install, where the top layer made of 15-mm GKF-panels is applied. Fireproofing: F0 Substructure: Channel framing section with metal panel permanently attached on one side. The metal panel on the opposite side is fixed in a decoupled way. Field of application: Connecting plasterboards or removable partitions to exterior façades with slim supports. Soundproofing: As per DIN EN ISO 140-03 Rw,P up to 52 dB with a width of just 330 mm Dimensions: Thickness of element: 58 mm Width of element: variable Height of element: variable Surface: GKF panels Other surfaces are available on request Patented method Subject to technical changes also without notification. F77 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. F90 Access Panel in Plasterboard Shaft Walls or Solid Walls LGK-510-F90 Fig. 192 Horizontal section £2100 240 Fig. 191 Elevation ³480 240 £2100 £5000 Fig. 193 Vertical section 200 £1000 ³528 £1000 300 Product Description Technical Data An access panel made of a tubular steel frame with plasterboard surface for installation in plasterboard shaft walls or solid walls. The panel is flush with the partition; only its strap hinge projects above the overall level of the opening. A 10-mm joint is visible on the other sides. Fireproofing: F90 as per DIN 4102 in F90 plasterboard shaft walls or solid walls Substructure: Outer frame made of galvanised tubular steel; the hinge can be installed with a choice of galvanised steel or highgrade steel. The substructure for fastening the outer frame is made of folded and galvanised steel sheet profiled section elements. Design options: Installation in F90 shaft walls with 2 x 25 mm plasterboard panelling (such as Knauf W628) or solid walls; element panelled with 2 x 25-mm GKF-panels, lock with square entering catch (visible on the surface), also with door handle, 2 access panels can be installed on top of one another. Static requirements: Max. height: max. 5 000 mm Partition thicknesses: Plasterboard shaft walls With panelling thickness of 2 x 25 mm plasterboard panels Dimensions: Clear height/width Height: max. 2 100 mm Width: max. 1 000 mm Subject to technical changes also without notification. F78 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so. F0 Access Panel in Plasterboard Partitions LGK-520-F0 Fig. 194 Elevation Fig. 195 Horizontal section Max. clearance = 1000 Max. clearance = 2000 10 4 Fig. 196 Vertical section Product Description Technical Data An access panel made of an aluminium frame with plasterboard surface for installation in plasterboard partitions. The panel is flush with the partition; only its hinge projects above the overall level of the opening. A 4-mm joint is visible on the other sides. This inspection access panel should only be used to close openings for installation and inspection purposes without any special requirements. Fireproofing: F0 Substructure: Outer frame made of aluminium; the strap hinge can be installed with a choice of galvanised steel or high-grade steel. The substructure for fastening the outer frame is made of folded and galvanised steel sheet profiled section elements. Design options: Access panel with only single-layer panelling with 12.5mm plasterboard panels; installation in partitions with single-layer or double-layer panelling; lock with square entering catch (visible on the surface) or with spring-loaded latch; also with door handle. Partition thicknesses: Plasterboard partitions and shaft walls with panelling thickness of 1 x or 2 x 12.5 mm Dimensions: Clear height/width Height: max. 2 000 mm Width: max. 1 000 mm Only for access panel with single-layer panelling (12.5 mm) Up to a clear dimension of 600/600 mm 4-mm joint at the perimeter with recessed hinge Also access panel with double-layer panelling (2 x 12.5 mm) Subject to technical changes also without notification. F79 15.0 Partitions Be sure to see the latest version of this page on our website at: www.lindner-holding.de or www.lindner.ag This document is the intellectual property of Lindner Holding KGaA Arnstorf. Without our approval, it may not be either reproduced or commercialised, distributed or presented to other individuals for commercial purposes without authorisation to do so.
© Copyright 2024 ExpyDoc