Work lift cylinder Double acting 7 MPa model CNB Pull sensor model model Compact model CNB02-15TB model CNB02-15TN Work lift cylinder new Push / pull sensor model model Push sensor model CNB02-15TD model CNB02-15TU www.pascaleng.co.jp 151 W o r k lif t c ylin d e r Push / pull sensor model D model CNB - D PAT. Push sensor model U model PAT. P. CNB - U PAT. PAT. P. Sensor valve (push) Sensor air (push) Sensor valve (push) Sensor air (push) Sensor air (pull) Sensor valve (pull) Sensor air exhaust Hydraulic and air circuit diagram Sensor air exhaust Hydraulic and air circuit diagram Flow control valve model VCF (option) Work lift cylinder Flow control valve model VCF (option) Air sensor unit Air sensor unit 5μm 5μm Sensor air (pull) Sensor air (push) 0.1∼0.2MPa (recommended air pressure) 0.1∼0.2MPa (recommended air pressure) Specifications → 154 page Specifications → 154 page Piping → 155 page Piping → 155 page Sensor valve → 156 page Sensor valve → 166 page Dimensions → 160 page Dimensions → 168 page Mounting details → 164 page 152 Sensor air (push) Mounting details → 172 page W o r k lif t c ylin d e r Compact model N Pull sensor model B model CNB - B PAT. PAT. P. model CNB - N No sensors available on compact model Sensor air (pull) Sensor valve (pull) Hydraulic and air circuit diagram Hydraulic circuit diagram Flow control valve model VCF (option) Work lift cylinder Flow control valve model VCF (option) Air sensor unit 5μm Sensor air (pull) 0.1∼0.2MPa (recommended air pressure) Specifications → 154 page Specifications → 154 page Piping → 155 page Piping → 155 page Sensor valve → 174 page Dimensions → 184 page Dimensions → 176 page Mounting details → 188 page Mounting details → 180 page 153 CNB Double acting 7MPa Work lift cylinder (common) Specifications Size Stroke Rod tip section shapes 10 15 CNB D : Push / pull sensor model 20 01 25 02 ー 35 04 T : Female thread rod U : Push sensor model P : Pin rod B : Pull sensor model 30 40 N : Compact model 45 50 Rod tip section shapes T : Female thread rod CNB01 Work lift cylinder Model Cylinder force (hydraulic pressure 7MPa) Cylinder force calculation formula *1 P : Pin rod CNB02 CNB04 Push kN 2.7 3.4 4.9 Pull kN 1.6 2.0 3.2 Push F=0.38×P F=0.49×P F=0.71×P Pull F=0.23×P F=0.29×P F=0.45×P Cylinder inner diameter mm 22 25 30 Rod diameter mm 14 16 18 Push cm 2 3.8 4.9 7.1 Pull cm 2 2.3 2.9 4.5 L/min 0.8 1.0 1.6 Recommended tightening torque of mounting screws *2 N·m 3.5 7 7 Effective area Max. oil flow rate ● Working pressure range:1∼7 MPa( model CNB-D, CNB-U, CNB-B), 0.5∼7 MPa(model CNB-N) ● Proof pressure:10.5 MPa ● Operating temperature:0∼70℃ ● Fluid used:General mineral based hydraulic oil (ISO-VG32 equivalent) ● Seals are resistant to chlorine-based cutting fluid. (not thermal resistant specification) *1:F=Cylinder force(kN), P=Hydraulic pressure(MPa) *2:ISO R898 class 12.9 154 ガスケット配管と G ネジ CNB Double acting 7MPa Work lift cylinder (common) Manifold piping and G port piping are available. Manifold piping G port piping A flow control valve (model VCF) and an air bleeding Refer to →193 page for details of G port pipe fitting. valve (model VCE) are mountable on the G ports of The flow control valve and air bleeding valve should be the cylinder when choosing manifold piping. mounted in the oil path when choosing G port piping. Plug Parallel thread connector O-ring Hydraulic pressure (2 circuits) O-ring Hydraulic pressure (2 circuits) Flow control valve model VCF Air bleeding valve model VCE →190 page →192 page Flow control valve Hydraulic port Air bleeding valve Work lift cylinder Hydraulic port Flow control valve Air bleeding valve ● In case of mounting flow control valve model VCF on the G port of the cylinder, air bleeding valve should be installed in the piping to the cylinder.(VCE Mounting details. Refer to → 192 page) 155 D のセンサバルブ CNB - D Double acting 7MPa Push / pull sensor model D Work lift cylinder Sensor valve function and structure Push end detection Sensor valve (push) Sensor valve (push) Sensor cam Piston rod Piston rod Hydraulic pressure Sensor air (pull) Sensor valve (pull) Close(Sensor ON) Sensor air(push) Open(Sensor OFF) Sensor air (pull) ● The sensor valve (push) is pushed down by the sensor cam and shuts off the sensor air flow when the piston rod reaches the push-end position. The sensor valve (pull) is pushed up by the hydraulic force to open for air exhaust and detects the push-end position. In the middle of stroke Sensor valve (push) Sensor valve (push) Piston rod Piston rod Work lift cylinder Hydraulic pressure Sensor air (pull) Hydraulic pressure Sensor valve (pull) Open(Sensor OFF) Sensor air(push) Open(Sensor OFF) Sensor valve (pull) ● The sensor valve (push) is pushed up by the hydraulic force while piston rod strokes and exhausts the sensor air. The sensor valve (pull) is pushed up by the hydraulic force and exhausts the sensor air. 156 D のセンサバルブ CNB - D Work lift cylinder Double acting 7MPa Push / pull sensor model D Sensor valve function and structure Pull end detection Sensor valve (push) Piston rod Sensor air (pull) Hydraulic pressure Sensor valve (pull) Open(Sensor OFF) Sensor air(push) Close(Sensor ON) Sensor valve (pull) ● The sensor valve (pull) is pushed down by the piston rod and shuts off the sensor air flow when the piston rod reaches the pull-end position. The sensor valve (push) is pushed up by the hydraulic force to open for air exhaust and detects the pull-end position. Work lift cylinder Sensor valve (push) Piston rod 157 D のセンサ信号 CNB - D Push / pull sensor model D Work lift cylinder Double acting 7MPa Push end, Pull end stroke detection signal Push end detection In the middle of stroke Sensor (push) Sensor (pull) ON OFF Piston rod Sensor valve (push) Piston rod Sensor valve (push) Air sensor Sensor (push) Sensor (pull) OFF OFF Air sensor Primary air Close Open Primary air Secondary air(push) Sensor ON Secondary air(push) Sensor OFF Secondary air(pull) Sensor OFF Secondary air(pull) Sensor OFF Sensor valve (pull) Sensor signal (push) ON Sensor signal (pull) OFF Open P u s h en d Open Sensor valve (pull) Sensor signal (push) OFF Sensor signal (pull) OFF In the middle of stroke More than 1MPa hydraulic pressure is required to operate the sensor valve. To obtain OFF signal in the middle of the valve stroke, over 1MPa of back pressure should be produced by using a meter-out type of flow control valve. In the middle of stroke Pull end detection Sensor (push) Sensor (pull) OFF OFF Piston rod Sensor valve (push) Piston rod Sensor valve (push) Air sensor Sensor (push) Sensor (pull) OFF ON Air sensor Work lift cylinder Primary air Open Open Secondary air(push) Sensor OFF Secondary air(push) Sensor OFF Secondary air(pull) Sensor OFF Secondary air(pull) Sensor ON Sensor valve (pull) Sensor signal (push) OFF Sensor signal (pull) OFF Primary air In the middle of stroke Open Close Sensor valve (pull) Sensor signal (push) OFF Sensor signal (pull) ON P u l l e nd More than 1MPa hydraulic pressure is required to operate the sensor valve. To obtain OFF signal in the middle of the valve stroke, over 1MPa of back pressure should be produced by using a meter-out type of flow control valve. 158 D のセンサ信号 CNB - D Push / pull sensor model D Work lift cylinder Air sensor triggering point Air sensor recommended condition of use GPS2-05 series 1.5 2.5 mm Sensor signal (push) Double acting 7MPa ON Supplier and manufactured by CKD model ISA2-G series manufactured by SMC OFF 0 1 mm ON pressure 0.1 0.2 MPa Inner diameter ø4 mm of piping OFF Sensor signal (pull) Air supply Overall piping length Piston rod stroke 5m or less ● Refer to the sensor supplier s instruction manual for the details of setting. Relation between sensor air pressure, sensor valve and piston stroke Push end Push stroke 1.5 2.5 mm The secondary air pressure when air is shut off 0.195 MPa The diagram shown on the left indicates the relation between the sensor valve, piston stroke, and secondary air pressure. (The pressure shown in the diagram is a reference based on the 0.2 MPa of primary air pressure for one piece of cylinder.) Since the new sensor valve works with less air-leakage compared to previous sensor valve, The secondary air pressure when air is exhausted 0.03 MPa Open Close Sensor valve (push) Pull end ● Enhances the pressure setting range of the sensor which enables the sensor to set easily. (Ex. Pressure setting range 0.03 0.195 MPa in the diagram) ● Allows the use for a number of cylinders by one air sensor because of better pressure holding when air is shut off. ● Allows to choose less air-consumed, i.e. small orifice diameter type, air sensor. Work lift cylinder Pressure setting range for air sensor ● Can create large dif ferential-pressure when opening and closing the sensor valve so that sensor primary pressure can be set as low as possible and reduce the consumption of air. Pull stroke New sensor valve 0 1 mm Previous sensor valve The secondary air pressure when air is shut off 0.195 MPa Pressure setting range for air sensor The secondary air pressure when air is exhausted 0.03 MPa Open Sensor valve Close (pull) Poppet structure ensures superior sealing performance and can create large differential-pressure when the valve is opening and closing, and air leakage can be minimized. Space Air leaks easily due to a large space. 159 TD の外形寸法図 CNB - TD Double acting 7MPa Push / pull sensor model D Work lift cylinder Dimensions (Female thread rod) Push hydraulic port G1/8 E B Pull hydraulic port G1/8 D 3.8 (plug projection depth) C Thread N Y 0 (Full stroke) øH f7 0 P At 11 V 25 J 15° 4-øX M S +0.5 øT -0.1 Cylinder removal thread 4-W1 thread through □F U R4 ø14 4-Z1 KK 0 2-O-ring FA K -0.2 4-øW O-ring FB Sensor air supply port (push) (→164 page) Sensor air supply port (pull) (→164 page) øGG Sensor air exhaust port (→164 page) Pull end øG f7 øGG Push end Sensor air exhaust range ø13 2-M3 thread depth 6 P.C.D. ED 2-M3 thread depth 6 Sensor air exhaust range ø13 P.C.D. ED Pull hydraulic port EA Pull hydraulic port R2 R2 EA Work lift cylinder øG f7 Sensor air exhaust port øEC ° 90 Sensor air exhaust port øEC R3 Push hydraulic port R3 CNB01-□ T D ● Mounting screws are not included. 160 Push hydraulic port TD の外形寸法図 CNB - TD Double acting 7MPa Push / pull sensor model D Work lift cylinder mm CNB01-□TD M od e l CNB04-□TD 10, 15, 20, 25, 30, 35, 40, 45, 50 Y (stroke) Push 0.38×Y 0.49×Y 0.71×Y Pull 0.23×Y 0.29×Y 0.45×Y At Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 70 Y+55 71 Y+56 73.5 Y+58.5 B 38 45 50 C 50.5 55 60 D 29 32.5 35 E 21.5 22.5 25 F 30.5 35 40 -0.025 -0.050 øG 35 øGG 34.4 øH 14 J 33 K KK 39 -0.025 -0.050 47 38.4 -0.016 -0.034 16 -0.025 -0.050 46.4 -0.016 -0.034 18 34 -0.016 -0.034 35 Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 37 Y+22 37 Y+22 38.5 Y+23.5 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 Y=10, 15 Y=20 Y=25∼50 27.5 32.5 27.5 32.5 29 34 32.5 M 8 9 10 N M6×1 M8×1.25 M8×1.25 P 11 14 14 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6 7 8 12 14 16 U (width across flats) 10 12 14 V 17 15 15 S (width across flats height) øT 4.5 øW M5×0.8 W1 8 øX 5.5 5.5 M6×1 M6×1 9.5 9.5 Z1 R3 R3 R5 EA 55° 25° 20° øEC 2 2.5 ED 28 31.5 P7 O-ring FA (fluorocarbon hardness Hs90) 38 P7 P7 AS568-026 AS568-028 AS568-030 Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 O-ring FB (fluorocarbon hardness Hs70) Flow control valve * 3.3 Air bleeding valve Work lift cylinder Cylinder capacity(cm3) CNB02-□TD *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□TD 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.8 0.8 CNB02-□TD 0.7 0.7 0.7 0.8 0.8 0.9 0.9 1.0 1.0 CNB04-□TD 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.2 1.3 161 PD の外形寸法図 CNB - PD Double acting 7MPa Push / pull sensor model D Work lift cylinder Dimensions (Pi n r o d ) Push hydraulic port G1/8 E B □F R4 -0.1 6 -0.2 ø14 4-Z1 Pull hydraulic port G1/8 D 3.8 (plug projection depth) C Y 0 (Full stroke) øH f7 0 øT -0.1 +0.5 Ap 11 V 25 J 15° 4-øX M S ° 45 Cylinder removal thread 4-W1 thread through Pin hole +0.012 ø6 H7 0 N ø5 KK 0 2-O-ring FA K -0.2 4-øW O-ring FB Sensor air supply port (push) (→164 page) Sensor air supply port (pull) (→164 page) øGG Sensor air exhaust port (→164 page) Pull end øG f7 øGG Push end Sensor air exhaust range ø13 2-M3 thread depth 6 P.C.D. ED 2-M3 thread depth 6 Sensor air exhaust range ø13 P.C.D. ED Pull hydraulic port EA Pull hydraulic port R2 R2 EA Work lift cylinder øG f7 Sensor air exhaust port øEC ° 90 Sensor air exhaust port øEC R3 Push hydraulic port R3 Push hydraulic port CNB01-□ P D ● Mounting screws are not included. ● Recommended material for pin:SCM435-H (HB269∼331) 162 PD の外形寸法図 CNB - PD Double acting 7MPa Push / pull sensor model D Work lift cylinder mm CNB01-□PD M od e l CNB02-□PD 10, 15, 20, 25, 30, 35, 40, 45, 50 Y (stroke) 0.38×Y Push 0.49×Y 0.23×Y Pull Ap 0.71×Y 0.29×Y 0.45×Y Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 76 Y+61 76 Y+61 79 Y+64 38 45 50 C 50.5 55 60 D 29 32.5 35 E 21.5 22.5 25 F 30.5 B 35 øGG 34.4 14 øH 35 -0.025 -0.050 øG 39 K KK 47 38.4 -0.016 -0.034 16 39 J 40 -0.025 -0.050 -0.025 -0.050 46.4 -0.016 -0.034 18 39 -0.016 -0.034 40.5 Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 37 Y+22 37 Y+22 38.5 Y+23.5 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 Y=10, 15 Y=20 Y=25∼50 27.5 32.5 27.5 32.5 29 34 32.5 M 9 9 9.5 N 5 5 6 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6.5 S 6.5 7 øT 10 10 12 V 17 15 15 4.5 øW M5×0.8 W1 8 øX 5.5 5.5 M6×1 M6×1 9.5 9.5 Z1 R3 R3 R5 EA 55° 25° 20° øEC 2 2.5 3.3 ED 28 31.5 38 O-ring FA (fluorocarbon hardness Hs90) P7 P7 P7 AS568-026 AS568-028 AS568-030 Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 O-ring FB (fluorocarbon hardness Hs70) Flow control valve * Air bleeding valve Work lift cylinder Cylinder capacity(cm3) CNB02-□PD *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□PD 0.6 0.6 0.7 0.7 0.7 0.7 0.7 0.8 0.8 CNB02-□PD 0.7 0.7 0.7 0.8 0.8 0.9 0.9 1.0 1.0 CNB04-□PD 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.2 1.3 163 D の取付穴加工図 CNB - D Push / pull sensor model D Work lift cylinder Double acting 7MPa Mounting details X X R3 Rz6.3 6.3 Avoid drilling piping hole close to taper area. Min. DE Min. DF DE DG DH 8 øDM 8 DC±0.2 DD±0.2 Rz6.3 4-BB Rz DR 30° 30° (8) 6.3 Rz øDL H8 □F R2 2-Max. ø4 6.3 Rz 30° * Exhaust side face processing range Sensor air piping hole (push) ø4∼ø6.5 In through hole X-X Sensor air piping hole (pull) ø4∼ø6.5 * Exhaust bottom face processing range * Exhaust piping hole Min. ø4 In blind hole X-X *:Exhaust piping hole must be made on either side or bottom face. Work lift cylinder Rz: ISO4287(1997) ● Apply an appropriate amount of grease to the chamfer and the b ore when mounting. E xcessive grease may be a blockage in the air passage, causing malfunction of the sensor. ● The 30°taper machining must be provided to avoid the damage of the O-ring. Ensure that there are no interference on taper area when drilling the hole for sensor air. 164 ● The sensor air piping hole can be used for a pilot hole of Rc 1/16 plug. Rc 1/16 plug D の取付穴加工図 CNB - D Double acting 7MPa Push / pull sensor model D Work lift cylinder mm CNB01-□TD Model CNB01-□PD Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DD 23 23 28 28 28 28 28 28 28 DE 27.5 27.5 32.5 32.5 32.5 32.5 32.5 32.5 32.5 DF 37.5 37.5 42.5 47.5 52.5 57.5 62.5 67.5 72.5 DG 7 7 12 12 12 12 12 12 12 DH 19 19 24 24 24 24 24 24 24 1 1 1 1 35 øDL 35.6 øDM DR +0.039 0 2 2 1 1 1 BB M4 F 30.5 R2 18 R3 22.5 mm CNB02-□TD Model CNB02-□PD Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DD 23 23 28 28 28 28 28 28 28 DE 27.5 27.5 32.5 32.5 32.5 32.5 32.5 32.5 32.5 DF 37.5 37.5 42.5 47.5 52.5 57.5 62.5 67.5 72.5 DG 7 7 12 12 12 12 12 12 12 DH 19 19 24 24 24 24 24 24 24 1 1 1 1 +0.039 0 øDL 39 øDM 39.6 DR 2 2 1 1 1 BB M5 F 35 R2 22 R3 25 CNB04-□PD Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DD 23 23 28 28 28 28 28 28 28 DE 27.5 27.5 32.5 32.5 32.5 32.5 32.5 32.5 32.5 DF 39 39 44 49 54 59 64 69 74 DG 7 7 12 12 12 12 12 12 12 DH 19 19 24 24 24 24 24 24 24 1 1 1 1 +0.039 0 øDL 47 øDM 47.6 DR 2 2 1 1 Work lift cylinder mm CNB04-□TD Model 1 BB M5 F 40 R2 24 R3 28 165 U のセンサバルブ CNB - U Push sensor model U Work lift cylinder Double acting 7MPa Push sensor valve function and structure In the middle of stroke ● The sensor valve (push) is pushed up by the hydraulic force and exhausts the sensor air while piston rod strokes. Sensor (push) Piston rod OFF Sensor valve (push) Air sensor Primary air Secondary air(push) Sensor OFF Open Sensor signal (push) OFF Pull end, in the middle of stroke More than 1MPa hydraulic pressure is required to operate the sensor valve. To obtain OFF signal in the middle of the valve stroke, over 1MPa of back pressure should be produced by using a meter-out type of flow control valve. Push end detection ● The sensor valve (push) is pushed down by the sensor cam and shuts off the sensor air flow Work lift cylinder when the piston rod reaches the push-end position, and detects the push-end position. Sensor (push) Sensor cam Piston rod ON Sensor valve (push) Air sensor Primary air Secondary air(push) Sensor ON Close Sensor signal (push) 166 ON P u s h e nd U のセンサバルブ CNB - U Double acting 7MPa Push sensor model U Work lift cylinder Air sensor triggering point Air sensor recommended condition of use GPS2-05 series 1.5 2.5 mm Sensor signal (push) Supplier and manufactured by CKD model ISA2-G series manufactured by SMC ON Air supply pressure OFF Inner diameter of piping Overall piping Piston rod stroke length 0.1 0.2 MPa ø4 mm 5m or less ● Refer to the sensor supplier s instruction manual for the details of setting. Relation between sensor air pressure, sensor valve and piston stroke Push stroke 1.5 2.5 mm The secondary air pressure when air is shut off 0.195 MPa Pressure setting range for air sensor The secondary air pressure when air is exhausted 0.03 MPa Open Close Sensor valve (push) The diagram shown above indicates the relation between the sensor valve, piston stroke, and secondary air pressure. ( The pressure shown in the diagram is a reference based on the 0.2 MPa of primary air pressure for one piece of cylinder.) Since the new sensor valve works with less air-leakage compared to previous sensor valve, ● Enhances the pressure setting range of the sensor which enables the sensor to set easily. (Ex. Pressure setting range 0.03 0.195 MPa in the diagram) ● Allows the use for a number of cylinders by one air sensor because of better pressure holding when air is shut off. ● Allows to choose less air-consumed, i.e. small orifice diameter type, air sensor. ● Can create large dif ferential-pressure when opening and closing the sensor valve so that sensor primary pressure can be set as low as possible and reduce the consumption of air. New sensor valve Poppet structure ensures superior sealing performance and can create large differential-pressure when the valve is opening and closing, and air leakage can be minimized. Work lift cylinder Push end Previous sensor valve Space Air leaks easily due to a large space. 167 TU の外形寸法図 CNB - TU Double acting 7MPa Push sensor model U Work lift cylinder Dimensions (Female thread rod) Push hydraulic port G1/8 E B Pull hydraulic port G1/8 D 3.8 (plug projection depth) C Thread N Y 0 (Full stroke) øH f7 At 11 V 25 J 15° M S 4-øX P +0.5 0 øT -0.1 Cylinder removal thread 4-W1 thread through □F U R4 ø14 4-Z1 0 2-O-ring FA K -0.2 KK 4-øW O-ring FB Sensor air exhaust port (→172 page) Sensor air supply port (push) (→172 page) øGG Pull end øG f7 øGG Push end P.C.D. ED 2-M3 thread depth 6 2-M3 thread depth 6 P.C.D. ED Pull hydraulic port EA Pull hydraulic port R2 R2 EA Work lift cylinder øG f7 Sensor air exhaust port øEC ° 90 Sensor air exhaust port øEC R3 Push hydraulic port R3 CNB01-□ T U ● Mounting screws are not included. 168 Push hydraulic port CNB - TU Double acting 7MPa Push sensor model U Work lift cylinder mm CNB01-□TU M od e l CNB02-□TU CNB04-□TU 10, 15, 20, 25, 30, 35, 40, 45, 50 Y (stroke) Push 0.38×Y 0.49×Y 0.71×Y Pull 0.23×Y 0.29×Y 0.45×Y At Y+51.5 Y+53.5 Y+57.5 B 38 45 50 C 50.5 55 60 D 29 32.5 35 E 21.5 22.5 25 F 30.5 35 -0.025 -0.050 øG 35 øGG 34.4 øH 14 39 40 -0.025 -0.050 47 38.4 -0.016 -0.034 16 -0.025 -0.050 46.4 -0.016 -0.034 18 -0.016 -0.034 J 33 34 35 K Y+18.5 Y+19.5 Y+22.5 KK Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 15.5 20.5 15.5 20.5 15.5 20.5 M 8 9 10 N M6×1 M8×1.25 M8×1.25 P 11 14 14 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6 7 8 S (width across flats height) 12 14 16 U (width across flats) 10 12 14 V 17 15 15 øT 4.5 øW M5×0.8 W1 8 øX 5.5 5.5 M6×1 M6×1 9.5 9.5 Z1 R3 R3 R5 EA 55° 25° 20° øEC 2 2.5 ED 28 31.5 38 O-ring FA (fluorocarbon hardness Hs90) P7 P7 P7 AS568-026 AS568-028 AS568-030 Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 O-ring FB (fluorocarbon hardness Hs70) Flow control valve * 3.3 Air bleeding valve Work lift cylinder Cylinder capacity(cm3) *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□TU 0.5 0.5 0.6 0.6 0.6 0.6 0.7 0.7 0.7 CNB02-□TU 0.7 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 CNB04-□TU 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.2 1.3 169 TU の外形寸法図 CNB - PU Double acting 7MPa Push sensor model U Work lift cylinder Dimensions (Pi n r o d ) Push hydraulic port G1/8 E B □F R4 -0.1 6 -0.2 ø14 4-Z1 Pull hydraulic port G1/8 D 3.8 (plug projection depth) C Y 0 (Full stroke) øH f7 0 øT -0.1 +0.5 Ap 11 V 25 J 15° 4-øX M S ° 45 Cylinder removal thread 4-W1 thread through Pin hole +0.012 ø6 H7 0 N ø5 0 2-O-ring FA K -0.2 KK 4-øW O-ring FB Sensor air exhaust port (→172 page) Sensor air supply port (push) (→172 page) øGG Pull end øG f7 øGG Push end P.C.D. ED 2-M3 thread depth 6 2-M3 thread depth 6 P.C.D. ED Pull hydraulic port EA Pull hydraulic port R2 R2 EA Work lift cylinder øG f7 Sensor air exhaust port øEC ° 90 Sensor air exhaust port øEC R3 Push hydraulic port R3 Push hydraulic port CNB01-□ P U ● Mounting screws are not included. ● Recommended material for pin:SCM435-H (HB269∼331) 170 TU の外形寸法図 CNB - PU Double acting 7MPa Push sensor model U Work lift cylinder mm CNB01-□PU M od e l CNB04-□PU 10, 15, 20, 25, 30, 35, 40, 45, 50 Y (stroke) Push 0.38×Y 0.49×Y 0.71×Y Pull 0.23×Y 0.29×Y 0.45×Y Y+57.5 Y+58.5 Y+63 B 38 45 50 C 50.5 55 60 D 29 32.5 35 E 21.5 22.5 25 F 30.5 35 40 Ap -0.025 -0.050 øG 35 øGG 34.4 øH 14 J 39 39 KK 47 38.4 -0.016 -0.034 16 -0.025 -0.050 46.4 -0.016 -0.034 18 39 Y+18.5 K -0.025 -0.050 -0.016 -0.034 40.5 Y+19.5 Y+22.5 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 15.5 20.5 15.5 20.5 15.5 20.5 M 9 9 9.5 N 5 5 6 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6.5 S 6.5 7 øT 10 10 12 V 17 15 15 4.5 øW M5×0.8 W1 8 øX 5.5 5.5 M6×1 M6×1 9.5 9.5 Z1 R3 R3 R5 EA 55° 25° 20° 3.3 øEC 2 2.5 ED 28 31.5 38 O-ring FA (fluorocarbon hardness Hs90) P7 P7 P7 AS568-026 AS568-028 AS568-030 Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 O-ring FB (fluorocarbon hardness Hs70) Flow control valve * Air bleeding valve Work lift cylinder Cylinder capacity(cm3) CNB02-□PU *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□PU 0.5 0.5 0.6 0.6 0.6 0.6 0.7 0.7 0.7 CNB02-□PU 0.7 0.7 0.7 0.7 0.8 0.8 0.8 0.9 0.9 CNB04-□PU 0.9 0.9 1.0 1.0 1.1 1.1 1.2 1.2 1.3 171 U の取付穴加工図 CNB - U Double acting 7MPa Push sensor model U Work lift cylinder Mounting details X X R3 6.3 Rz øDL H8 Avoid drilling piping hole close to taper area. (8) Rz6.3 6.3 4-BB 6.3 Rz Min. DE Min. DF DE DG Rz øDM 8 DC±0.2 Rz6.3 DR 30° 30° □F R2 2-Max. ø4 30° In through hole X-X * Exhaust side face processing range Sensor air piping hole (push) ø4∼ø6.5 * Exhaust bottom face processing range In blind hole X-X * Exhaust piping hole Min. ø4 *:Exhaust piping hole must be made on either side or bottom face. Work lift cylinder Rz: ISO4287(1997) ● Apply an appropriate amount of grease to the chamfer and the b ore when mounting. E xcessive grease may be a blockage in the air passage, causing malfunction of the sensor. ● The 30°taper machining must be provided to avoid the damage of the O-ring. Ensure that there are no interference on taper area when drilling the hole for sensor air. 172 ● The sensor air piping hole can be used for a pilot hole of Rc 1/16 plug. Rc 1/16 plug U の取付穴加工図 CNB - U Double acting 7MPa Push sensor model U Work lift cylinder mm CNB01-□TU Model CNB01-□PU Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DE 15.5 15.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 DF 29 34 39 44 49 54 59 64 69 DG 7 7 12 12 12 12 12 12 12 1 1 1 1 +0.039 0 øDL 35 øDM 35.6 DR 2 2 1 1 1 BB M4 F 30.5 R2 18 R3 22.5 mm CNB02-□TU Model CNB02-□PU Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DE 15.5 15.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 DF 30 35 40 45 50 55 60 65 70 DG 7 7 12 12 12 12 12 12 12 1 1 1 1 39 øDL 39.6 øDM DR +0.039 0 2 2 1 1 1 BB M5 F 35 R2 22 R3 25 CNB04-□TU Model CNB04-□PU Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DE 15.5 15.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 DF 33 38 43 48 53 58 63 68 73 DG 7 7 12 12 12 12 12 12 12 1 1 1 1 +0.039 0 øDL 47 øDM 47.6 DR 2 2 1 1 Work lift cylinder mm 1 BB M5 F 40 R2 24 R3 28 173 B のセンサバルブ CNB - B Pull sensor model B Work lift cylinder Double acting 7MPa Pull sensor valve function and structure In the middle of stroke ● The sensor valve (pull) is pushed up by the hydraulic force and exhausts the sensor air while piston rod strokes. Sensor (pull) Piston rod OFF Air sensor Primary air Secondary air(pull) Sensor OFF Sensor valve (pull) Open Sensor signal (pull) OFF Push end, in the middle of stroke More than 1MPa hydraulic pressure is required to operate the sensor valve. To obtain OFF signal in the middle of the valve stroke, over 1MPa of back pressure should be produced by using a meter-out type of flow control valve. Pull end detection ● The sensor valve (pull) is pushed down by the piston rod and shuts off the sensor air flow when the piston rod reaches the pull-end position, and detects the pull-end position. Work lift cylinder Sensor (pull) Piston rod ON Air sensor Primary air Secondary air(pull) Sensor ON Sensor valve (pull) Close Sensor signal (pull) 174 ON P u l l e nd B のセンサバルブ CNB - B Double acting 7MPa Pull sensor model B Work lift cylinder Air sensor triggering point Air sensor recommended condition of use GPS2-05 series 0 1 mm Supplier and manufactured by CKD model ISA2-G series manufactured by SMC ON Air supply OFF Sensor signal (pull) pressure Inner diameter of piping Overall piping Piston rod stroke length 0.1 0.2 MPa ø4 mm 5m or less ● Refer to the sensor supplier s instruction manual for the details of setting. Relation between sensor air pressure, sensor valve and piston stroke Pull stroke 0 1 mm The secondary air pressure when air is shut off 0.195 MPa Pressure setting range for air sensor The secondary air pressure when air is exhausted. 0.03 MPa Open Sensor valve Close (pull) The diagram shown above indicates the relation between the sensor valve, piston stroke, and secondary air pressure. ( The pressure shown in the diagram is a reference based on the 0.2 MPa of primary air pressure for one piece of cylinder.) Since the new sensor valve works with less air-leakage compared to previous sensor valve, ● Enhances the pressure setting range of the sensor which enables the sensor to set easily. (Ex. Pressure setting range 0.03 0.195 MPa in the diagram) ● Allows the use for a number of cylinders by one air sensor because of better pressure holding when air is shut off. ● Allows to choose less air-consumed, i.e. small orifice diameter type, air sensor. ● Can create large dif ferential-pressure when opening and closing the sensor valve so that sensor primary pressure can be set as low as possible and reduce the consumption of air. New sensor valve Poppet structure ensures superior sealing performance and can create large differential-pressure when the valve is opening and closing, and air leakage can be minimized. Work lift cylinder Pull end Previous sensor valve Space Air leaks easily due to a large space. 175 TB の外形寸法図 CNB - TB Double acting 7MPa Pull sensor model B Work lift cylinder Dimensions (Female thread rod) Push hydraulic port G1/8 E B Pull hydraulic port G1/8 D 3.8 (plug projection depth) C Thread N Y 0 (Full stroke) øH f7 0 P At 11 V 25 J 15° 4-øX M S +0.5 øT -0.1 Cylinder removal thread 4-W1 thread through □F U R4 ø14 4-Z1 0 K -0.2 2-O-ring FA KK 4-øW O-ring FB Sensor air exhaust port (→180 page) Sensor air supply port (pull) (→180 page) øGG Pull end øG f7 øGG Push end Sensor air exhaust range ø13 2-M3 thread depth 6 P.C.D. ED 2-M3 thread depth 6 Sensor air exhaust range ø13 P.C.D. ED Pull hydraulic port EA Pull hydraulic port R2 R2 EA Work lift cylinder øG f7 ° 90 R3 Push hydraulic port R3 CNB01-□ T B ● Mounting screws are not included. 176 Push hydraulic port TB の外形寸法図 CNB - TB Double acting 7MPa Pull sensor model B Work lift cylinder mm CNB01-□TB M od e l CNB04-□TB 10, 15, 20, 25, 30, 35, 40, 45, 50 Y (stroke) Push 0.38×Y 0.49×Y 0.71×Y Pull 0.23×Y 0.29×Y 0.45×Y At Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 58 Y+43 59 Y+44 61.5 Y+46.5 B 38 45 50 C 48 55 60 D 29 32.5 35 E 19 22.5 25 F 30.5 35 40 -0.025 -0.050 øG 35 øGG 34.4 øH 14 J 33 K KK 39 -0.025 -0.050 47 38.4 -0.016 -0.034 16 -0.025 -0.050 46.4 -0.016 -0.034 18 34 -0.016 -0.034 35 Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 25 Y+10 25 Y+10 26.5 Y+11.5 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 15.5 20.5 15.5 20.5 15.5 20.5 M 8 9 10 N M6×1 M8×1.25 M8×1.25 P 11 14 14 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6 7 8 12 14 16 U (width across flats) 10 12 14 V 17 15 15 S (width across flats height) øT 4.5 øW M5×0.8 W1 8 øX 5.5 5.5 M6×1 M6×1 9.5 9.5 Z1 R3 R3 R5 EA 55° 25° 20° ED 28 31.5 38 O-ring FA (fluorocarbon hardness Hs90) P7 P7 P7 AS568-026 AS568-028 AS568-030 Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 O-ring FB (fluorocarbon hardness Hs70) Flow control valve * Air bleeding valve Work lift cylinder Cylinder capacity(cm3) CNB02-□TB *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□TB 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 CNB02-□TB 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.8 CNB04-□TB 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.1 177 PB の外形寸法図 CNB - PB Double acting 7MPa Pull sensor model B Work lift cylinder Dimensions (Pi n r o d ) Push hydraulic port G1/8 E B □F R4 -0.1 6 -0.2 ø14 4-Z1 Pull hydraulic port G1/8 D 3.8 (plug projection depth) C Y 0 (Full stroke) øH f7 0 øT -0.1 +0.5 Ap 11 V 25 J 15° 4-øX M S ° 45 Cylinder removal thread 4-W1 thread through Pin hole +0.012 ø6 H7 0 N ø5 0 K -0.2 2-O-ring FA KK 4-øW O-ring FB Sensor air exhaust port (→180 page) Sensor air supply port (pull) (→180 page) øGG Pull end øG f7 øGG Push end Sensor air exhaust range ø13 2-M3 thread depth 6 P.C.D. ED 2-M3 thread depth 6 Sensor air exhaust range ø13 P.C.D. ED Pull hydraulic port EA Pull hydraulic port R2 R2 EA Work lift cylinder øG f7 ° 90 R3 Push hydraulic port R3 Push hydraulic port CNB01-□ P B ● Mounting screws are not included. ● Recommended material for pin:SCM435-H (HB269∼331) 178 PB の外形寸法図 CNB - PB Double acting 7MPa Pull sensor model B Work lift cylinder mm CNB01-□PB M od e l CNB04-□PB 10, 15, 20, 25, 30, 35, 40, 45, 50 Y (stroke) 0.38×Y Push 0.49×Y 0.23×Y Pull Ap 0.71×Y 0.29×Y 0.45×Y Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 64 Y+49 64 Y+49 67 Y+52 38 B 45 50 C 48 55 60 D 29 32.5 35 E 19 22.5 25 F 30.5 35 øGG 34.4 14 øH 35 -0.025 -0.050 øG 39 Y=10 K KK 47 38.4 -0.016 -0.034 16 39 J 40 -0.025 -0.050 46.4 -0.016 -0.034 18 39 Y=15∼50 Y=10 -0.025 -0.050 -0.016 -0.034 40.5 Y=15∼50 Y=10 Y=15∼50 25 Y+10 25 Y+10 26.5 Y+11.5 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 Y=10, 15 Y=20∼50 15.5 20.5 15.5 20.5 15.5 20.5 M 9 9 9.5 N 5 5 6 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6.5 S 6.5 7 øT 10 10 12 V 17 15 15 4.5 øW M5×0.8 W1 8 øX 5.5 5.5 M6×1 M6×1 9.5 9.5 Z1 R3 R3 R5 EA 55° 25° 20° ED 28 31.5 38 O-ring FA (fluorocarbon hardness Hs90) P7 P7 P7 AS568-026 AS568-028 AS568-030 Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 O-ring FB (fluorocarbon hardness Hs70) Flow control valve * Air bleeding valve Work lift cylinder Cylinder capacity(cm3) CNB02-□PB *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□PB 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.6 0.6 CNB02-□PB 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 0.8 CNB04-□PB 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.1 179 B の取付穴加工図 CNB - B Double acting 7MPa Pull sensor model B Work lift cylinder Mounting details X X R3 DE DG Min. DE Avoid drilling piping hole close to taper area. (8) Rz6.3 6.3 DR Rz øDM 8 DC±0.2 Rz6.3 4-BB 6.3 Rz Min. DF 6.3 Rz øDL H8 3 30° 0° □F R2 2-Max. ø4 * Exhaust side face processing range 30° In through hole X-X Sensor air piping hole (pull) ø4∼ø6.5 * Exhaust bottom face processing range In blind hole X-X * Exhaust piping hole Min. ø4 *:Exhaust piping hole must be made on either side or bottom face. Work lift cylinder Rz: ISO4287(1997) ● Apply an appropriate amount of grease to the chamfer and the b ore when mounting. E xcessive grease may be a blockage in the air passage, causing malfunction of the sensor. ● The 30°taper machining must be provided to avoid the damage of the O-ring. Ensure that there are no interference on taper area when drilling the hole for sensor air. 180 ● The sensor air piping hole can be used for a pilot hole of Rc 1/16 plug. Rc 1/16 plug B の取付穴加工図 CNB - B Double acting 7MPa Pull sensor model B Work lift cylinder mm CNB01-□TB Model CNB01-□PB Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DE 15.5 15.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 DF 25.5 25.5 30.5 35.5 40.5 45.5 50.5 55.5 60.5 DG 7 7 12 12 12 12 12 12 12 1 1 1 1 +0.039 0 øDL 35 øDM 35.6 DR 2 2 1 1 1 BB M4 F 30.5 R2 18 R3 22.5 mm CNB02-□TB Model CNB02-□PB Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DE 15.5 15.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 DF 25.5 25.5 30.5 35.5 40.5 45.5 50.5 55.5 60.5 DG 7 7 12 12 12 12 12 12 12 1 1 1 1 +0.039 0 øDL 39 øDM 39.6 DR 2 2 1 1 1 BB M5 F 35 R2 22 R3 25 mm CNB04-□PB Strok e 10 15 20 25 30 35 40 45 50 DC 11 11 16 16 16 16 16 16 16 DE 15.5 15.5 20.5 20.5 20.5 20.5 20.5 20.5 20.5 DF 27 27 32 37 42 47 52 57 62 DG 7 7 12 12 12 12 12 12 12 1 1 1 1 +0.039 0 øDL 47 øDM 47.6 DR 2 2 1 1 1 BB M5 F 40 R2 24 R3 28 Work lift cylinder CNB04-□TB Model 181 配管の注意 CNB - Work lift cylinder sensor model (common) Double acting 7MPa Caution for piping Refer to the diagram shown below for the sensor air exhaust port. Mounting in blind hole (Sensor air exhaust:side face) Mounting in blind hole (Sensor air exhaust:bottom face) Sensor air Sensor air Sensor air Sensor air Sensor air Sensor air Check valve Work lift cylinder Sensor air exhaust 182 Mounting in through hole Pipe flange Sensor air exhaust Check valve Sensor air exhaust Check valve ● Use a check valve with cracking pressure of 0.005 MPa or less if there is a risk of metal chips or coolant intrusion. Recommended check valve : AKH or AKB series manufactured by SMC. ● Furnish the piping by means of the pipe flange when mounting in a through hole. The flange is mountable with M3 threads at the bottom of the cylinder. Be sure to provide an opening not to cover the exhaust port. See the sketch shown above. 183 Work lift cylinder TN の外形寸法図 CNB - TN Double acting 7MPa Compact model N Work lift cylinder Dimensions (Female thread rod) Push hydraulic port G1/8 E D B □F U R4 ø14 4-Z1 Pull hydraulic port G1/8 3.8 (plug projection depth) Thread N Y 0 (Full stroke) C øH f7 0 P At K -0.2 R 0. 4 11 V 25 J 15° M S +0.5 øT -0.1 øG 0 2-O-ring -0.1 -0.2 Push end Work lift cylinder Pull end R2 Pull hydraulic port ● Mounting screws are not included. R3 184 Push hydraulic port TN の外形寸法図 CNB - TN Double acting 7MPa Compact model N Work lift cylinder mm CNB01-□TN M od e l CNB02-□TN CNB04-□TN 10, 15, 20, 25, 30, 35, 40, 45, 50 Push 0.38×Y 0.49×Y 0.71×Y Pull 0.23×Y 0.29×Y 0.45×Y At Y+39.5 Y+41.5 Y+45.5 B 38 45 50 C 48 55 60 D 29 32.5 35 E 19 22.5 25 F 30.5 35 40 35 39 Cylinder capacity(cm3) øG -0.016 -0.034 14 J 33 34 35 K Y+6.5 Y+7.5 Y+10.5 M 8 9 10 N M6×1 M8×1.25 M8×1.25 P 11 14 14 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6 7 8 12 14 16 U (width across flats) 10 12 14 V 17 15 15 øT 18 -0.016 -0.034 øH S (width across flats height) 16 47 -0.016 -0.034 øW 4.5 5.5 5.5 øX 8 9.5 9.5 Z1 R3 R3 R5 O-ring (fluorocarbon hardness Hs90) P7 P7 P7 Flow control valve * Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 Air bleeding valve Work lift cylinder Y (stroke) *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□TN 0.4 0.4 0.5 0.5 0.5 0.5 0.6 0.6 0.6 CNB02-□TN 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 CNB04-□TN 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.1 185 PN の外形寸法図 CNB - PN Compact model N Work lift cylinder Double acting 7MPa Dimensions (Pi n r o d ) Push hydraulic port G1/8 E B □F R4 -0.1 6 -0.2 ø14 4-Z1 Pull hydraulic port G1/8 D 3.8 (plug projection depth) C Y 0 (Full stroke) øH f7 0 øT -0.1 +0.5 Pin hole +0.012 ø6 H7 0 Ap K -0.2 R 0. 4 11 V 25 J 15° M S ° 45 N ø5 øG 0 2-O-ring -0.1 -0.2 Push end Work lift cylinder Pull end R2 Pull hydraulic port ● Mounting screws are not included. ● Recommended material for pin:SCM435-H (HB269∼331) R3 186 Push hydraulic port PN の外形寸法図 CNB - PN Double acting 7MPa Compact model N Work lift cylinder mm CNB01-□PN M od e l CNB02-□PN CNB04-□PN 10, 15, 20, 25, 30, 35, 40, 45, 50 Push 0.38×Y 0.49×Y 0.71×Y Pull 0.23×Y 0.29×Y 0.45×Y Y+45.5 Y+46.5 Y+51 B 38 45 50 C 48 55 60 D 29 32.5 35 E 19 22.5 25 F 30.5 35 40 35 39 Cylinder capacity(cm3) Ap øG -0.016 -0.034 16 47 -0.016 -0.034 14 J 39 39 K Y+6.5 Y+7.5 M 9 9 9.5 N 5 5 6 R2 18 22 24 R3 22.5 25 28 R4 16.2 20 22 6.5 S 18 -0.016 -0.034 øH 40.5 Y+10.5 6.5 7 øT 10 10 12 V 17 15 15 øW 4.5 5.5 5.5 øX 8 9.5 9.5 Z1 R3 R3 R5 O-ring (fluorocarbon hardness Hs90) P7 P7 P7 Flow control valve * Meter-in VCF01S VCF01 VCF01 Meter-out VCF01S-O VCF01-O VCF01-O VCE01 VCE01 VCE01 Air bleeding valve Work lift cylinder Y (stroke) *:Select the right model of VCF according to the size of the cylinder. Refer to each page for the details of options. ● Flow control valve →190 page ● Air bleeding valve →192 page Mass kg Strok e 10 15 20 25 30 35 40 45 50 CNB01-□PN 0.4 0.4 0.5 0.5 0.5 0.5 0.6 0.6 0.6 CNB02-□PN 0.6 0.6 0.6 0.6 0.7 0.7 0.7 0.8 0.8 CNB04-□PN 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.1 1.1 187 N の取付穴加工図 CNB - N Double acting 7MPa Compact model N Work lift cylinder Mounting details X □F R2 2-Max. ø4 X R3 4-BB +1 øA 0 .5 C0 Rz6.3 X-X Rz: ISO4287(1997) Work lift cylinder mm 188 CNB01-□TN CNB02-□TN CNB04-□TN CNB01-□PN CNB02-□PN CNB04-□PN 35 39 47 F 30.5 35 40 R2 18 22 24 R3 22.5 25 28 BB M4 M5 M5 M od e l øA N の取付穴加工図 CNB Double acting 7MPa Work lift cylinder (common) C o mp a r is o n d i m e ns i o na l ( r e f e r e nc e ) model CNB□-□□U model CNB□-□□B model CNB□-□□N Push / pull sensor model D Push sensor model U Pull sensor model B Compact model N D U B N model CNB□-□□D mm CNB01-□ M od e l Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 37 Y+22 37 Y+22 38.5 Y+23.5 N Y+19.5 Y+22.5 Y=10 Y=15∼50 Y=10 Y=15∼50 Y=10 Y=15∼50 25 Y+10 25 Y+10 26.5 Y+11.5 Y+6.5 Y+7.5 Y+10.5 Work lift cylinder Y+18.5 U B CNB04-□ 10, 15, 20, 25, 30, 35, 40, 45, 50 Y (stroke) D CNB02-□ 189
© Copyright 2025 ExpyDoc