NE rd l oa co l b s to ro bu ro nt d p co r Mo ion t MB fo ica n mu m co W Air Conditioning One Way Cassette Fan Coils Carisma Coanda CCN Carisma Coanda CCN-ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n° 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction CCN Version • Main components • Dimensions, Weight, Water content • EUROVENT certifications • Working conditions and Air throw • Emissions • Water side pressure drop • Accessories • Control operations • Wall electronic controls • Speed switches • Electronic control accessories • Wireless control system • Controls and units MB version Page Page Page Page Page Page Page Page Page Page Page Page Page 3 4 6 7 8 12 13 15 16 18 19 20 22 Page Page Page Page Page Page Page Page Page Page 23 24 26 27 28 32 33 35 36 37 CCN-ECM Version • Main components • Dimensions, Weight, Water content • EUROVENT certifications • Working conditions and Air throw • Emissions • Water side pressure drop • Accessories • CCN–ECM configuration • CR-T-ECM Wall electronic control • CR-T-ECM Accessories CCN / CCN-ECM Version • Controls and units MB version • Management system for a network of units Page 38 Page 44 Thanks to the particular air handling section, Carisma Coanda cassette units generate an airflow with a “coanda” effect. The unit is suitable for installation in a suspended ceiling. Air intake is from the bottom while the air supply is parallel to the ceiling, through practical and functional intake and outlet grids. The “coanda” effect creates excellent circulation of the air inside the room. In addition to the traditional AC asynchronous motors are available a innovative electronic motors with extremely low energy consumption, controlled by an inverter board and identified by ECM. The EC motors allow to decrease electric consumption by more than 50% compared to traditional AC asynchronous motors. They enable to control the air flow continuously and the ambient temperature with precision, with further benefits in terms of very low noise levels thanks to the reduced average working speed. Every unit can be supplied with 1 coil (2 pipe system) and possibly an electric heating element, or with 2 coils (4 pipe system) with one or two rows, for water supply at a low temperature. Fresh air may be mixed with room air. A condensate pump may also be supplied as an accessory. In addition to the conventional temperature and speed control systems, there is also the possibility to control operation of each unit through a single remote control with central supervisor software installed on a PC (Sabianet). With AC asynchronous motor units it is also possible to use the completely wireless electronic control system based on radio communication, Free Sabiana, with great advantages in terms of installation flexibility and maximum precision in measuring room temperature. Sabiana take part to the Eurovent program of fan coil performance certification. The official figures are published in the Eurovent web sites www.eurovent-certification.com and www.certiflash.com. The tested performances are: • Cooling total emission at the following conditions: - water temperature +7°C E.W.T. +12°C L.W.T. - air temperature +27°C dry bulb +19°C wet bulb • Cooling sensible emission at the following conditions: - water temperature +7°C E.W.T. +12°C L.W.T. - air temperature +27°C dry bulb +19°C wet bulb • Heating emission (2-pipe units) at the following conditions: - water temperature +50°C E.W.T. - air temperature +20°C - water flow rate as for the cooling conditions • Heating emission (4-pipe units) at the following conditions: - water temperature +70°C E.W.T. +60°C L.W.T. - air temperature +20°C • Fan absorption • Water pressure drop • Sound power Main components Carisma Coanda CCN Version Constructional features of the main components Casing Made from 1 mm galvanized steel insulated with polyolefin (PO) foam (class M1). Diffuser with intake grille In prepainted metal sheet in RAL 9003 colour with intake grille that can be opened for inspection and maintenance of the air filter. Air Filter Polypropylene cellular fabric regenerating filter. Fan Assembly The fans have aluminium or plastic blades directly keyed on the motor with double aspiration and they are dynamically and statically balanced during manufacture in order to have an extremely quiet operation. Electric motor The motor is wired for single phase and has six speeds, three of which are connected, with capacitor. The motor is fitted on sealed for life bearings and is secured on anti-vibration and self-lubricating mountings. Internal thermal protection with automatic reset, protection IP 20, class B. The speeds connected in the factory are indicated by “MIN, MED and MAX” in the following tables. Heat exchange coil It is manufactured from drawn copper tube and the aluminium fins are mechanically bonded onto the tube by an expansion process. The coil has two 1/2 inch BSP internal connections and 1/8 inch BSP air vent and drain. The heat exchanger is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. The connection side cannot be changed on site. Condensate Collection Tray Made from plastic (ABS UL94 HB), with an “L”-shape fitted on the inner casing; the try is insulated with polyolefin (PO) foam (class M1). The outside diameter of the condensate discharge pipe is 15mm. Round diffuser The Carisma Coanda one-way cassette units are supplied with round diffusers suitably designed to generate an airflow with “coanda” effect. The direction of diffuser air flow can be adjusted on site. 3 Dimensions, Weight, Water content Carisma Coanda Gr 1 - 3 diffusers CCN Version Carisma Coanda Carisma Coanda Gr 2 - 5 diffusers A 592 592 A Carisma Coanda Gr 3 - 6 diffusers 592 A Water inlet Water outlet Coil connections on the left 4 Dimensions, Weight, Water content CCN Version Carisma Coanda W 730 370 DIMENSIONS (mm) Model A E F W 1 2 3 592 454 78 750 970 884 43 1130 1192 1099 46,5 1350 weight (kg) Model Rows 3 3+1 3+2 4 4+1 1 Weight packed unit 2 3 Weight unpacked unit 1 2 3 18 20 23 20 23 34 40 46 37 42 44 51 58 48 54 16 19 22 18 21 33 38 43 35 40 42 48 54 45 51 Water content (l) Rows Model 3 4 +1 +2 1 2 3 0,6 0,8 0,2 0,4 1,3 1,7 0,4 0,8 1,7 2,4 0,5 1,0 5 CCN Version Carisma Coanda EUROVENT certifications www.eurovent-certification.com www.certiflash.com Technical features 2-pipe units The following standard rating conditions are used: COOLING (summer operation) Entering air temperature: + 27°C d.b. / + 19°C w.b. Water temperature: + 7°C E.W.T. / + 12°C L.W.T. Model CCN 13 1 (E) 2 (E) 3 Speed MIN MED Air flow m3/h 140 180 220 Cooling total emission (E) kW 0,88 1,06 1,26 Cooling sensible emission (E) kW 0,66 0,81 0,98 Heating (E) kW 1,08 1,33 1,59 ∆P Cooling (E) kPa 2,4 3,3 4,5 ∆P Heating (E) kPa 1,8 2,6 3,5 Fan (E) W 16 22 32 Sound power (E) Lw dB(A) 35 41 46 Sound pressure (*) Lp dB(A) 26 32 37 Model HEATING (winter operation) Entering air temperature: + 20°C Water temperature: + 50°C E.W.T. Water flow rate as for the cooling conditions CCN 23 4 5 (E) 6 MAX 245 280 305 1,35 1,50 1,60 1,06 1,18 1,27 1,73 1,93 2,08 5,1 6,1 6,8 4,0 4,9 5,6 38 49 66 49 52 55 40 43 46 CCN 14 1 (E) 2 (E) 3 Speed MIN MED Air flow m3/h 140 180 220 Cooling total emission (E) kW 0,97 1,19 1,44 Cooling sensible emission (E) kW 0,71 0,88 1,07 Heating (E) kW 1,14 1,42 1,72 ∆P Cooling (E) kPa 4,7 6,7 9,2 ∆P Heating (E) kPa 3,7 5,4 7,6 Fan (E) W 16 22 32 Sound power (E) Lw dB(A) 35 41 46 Sound pressure (*) Lp dB(A) 26 32 37 4 245 1,55 1,17 1,88 10,6 8,8 38 49 40 1 (E) 2 (E) 3 4 (E) 5 MIN MED MAX 200 240 305 380 470 1,37 1,62 1,97 2,37 2,81 1,00 1,19 1,47 1,77 2,13 1,60 1,91 2,35 2,86 3,43 2,9 3,9 5,5 7,6 10,3 2,3 3,1 4,5 6,3 8,4 24 27 34 44 57 33 36 42 48 54 24 27 33 39 45 CCN 33 6 560 3,23 2,47 3,95 13,1 10,8 71 57 48 1 (E) MIN 290 1,97 1,44 2,30 6,4 5,2 27 35 26 6 1 560 3,58 2,67 4,44 21,7 17,9 71 57 48 290 2,05 1,48 2,38 4,7 3,9 27 35 26 2 360 2,37 1,74 2,79 8,8 7,3 33 41 32 CCN 24 5 (E) MAX 280 1,74 1,31 2,10 12,9 10,7 49 52 43 6 305 1,87 1,42 2,27 14,6 12,3 66 55 46 1 (E) 2 (E) 3 4 (E) 5 MIN MED MAX 200 240 305 380 470 1,44 1,72 2,12 2,57 3,09 1,04 1,24 1,54 1,88 2,28 1,69 2,03 2,54 3,12 3,79 4,4 6,0 8,6 12,1 16,8 3,5 4,8 7,1 10,2 13,6 24 27 34 44 57 33 36 42 48 54 24 27 33 39 45 3 (E) MED 440 2,84 2,11 3,37 12,1 9,8 42 46 37 4 (E) MAX 540 3,34 2,51 4,02 16,2 13,4 59 52 43 5 6 620 3,75 2,83 4,53 19,8 16,3 72 55 46 680 4,05 3,07 4,88 22,7 18,6 84 57 48 5 (E) MAX 620 4,02 2,98 4,77 15,5 12,6 72 55 46 6 CCN 34 2 (E) MIN 360 2,49 1,81 2,90 6,7 5,5 33 41 32 3 440 3,00 2,20 3,51 9,3 7,3 42 46 37 4 (E) MED 540 3,56 2,63 4,20 12,6 10,0 59 52 43 680 4,36 3,25 5,20 17,9 14,6 84 57 48 4-pipe units The following standard rating conditions are used: COOLING (summer operation) Entering air temperature: + 27°C d.b. / + 19°C w.b. Water temperature: + 7°C E.W.T. / + 12°C L.W.T. Model CCN 13 + 1 1 (E) 2 (E) 3 Speed MIN MED Air flow m3/h 140 180 220 Cooling total emission (E) kW 0,88 1,06 1,26 Cooling sensible emission (E) kW 0,66 0,81 0,98 Heating (E) kW 0,92 1,08 1,25 ∆P Cooling (E) kPa 2,4 3,3 4,5 ∆P Heating (E) kPa 1,6 2,1 2,7 Fan (E) W 16 22 32 Sound power (E) Lw dB(A) 35 41 46 Sound pressure (*) Lp dB(A) 26 32 37 (E) = Eurovent certified performance. 4 5 (E) 6 MAX 245 280 305 1,35 1,50 1,60 1,06 1,18 1,27 1,34 1,47 1,56 5,1 6,1 6,8 3,1 3,6 4,0 38 49 66 49 52 55 40 43 46 HEATING (winter operation) Entering air temperature: + 20°C Water temperature: + 70°C E.W.T. / + 60°C L.W.T. CCN 23 + 1 1 (E) 2 (E) 3 4 (E) 5 MIN MED MAX 200 240 305 380 470 1,37 1,62 1,97 2,37 2,81 1,00 1,19 1,47 1,77 2,13 1,49 1,71 2,02 2,35 2,73 2,9 3,9 5,5 7,6 10,3 0,9 1,2 1,6 2,0 2,6 24 27 34 44 57 33 36 42 48 54 24 27 33 39 45 CCN 33 + 1 6 560 3,23 2,47 3,07 13,1 3,2 71 57 48 1 (E) MIN 290 1,97 1,44 2,12 6,4 2,0 27 35 26 2 360 2,37 1,74 2,47 8,8 2,6 33 41 32 3 (E) MED 440 2,84 2,11 2,87 12,1 3,4 42 46 37 4 (E) MAX 540 3,34 2,51 3,30 16,2 4,3 59 52 43 5 6 620 3,75 2,83 3,64 19,8 5,1 72 55 46 680 4,05 3,07 3,89 22,7 5,8 84 57 48 MIN-MED-MAX = Standard connected speeds. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. 6 CCN Version Carisma Coanda Working conditions and Air throw Working conditions Max. entering water temperature..................... + 80 °C MIn. entering water temperature........................ + 5 °C for entering water temperatures below + 5°C, contact “SABIANA” technical department Max. rated pressure............................................1000 kPa (10 bars) Installation height (m) Model 1 2 3 Minimum Maximum 2,6 3,2 2,6 3,2 2,6 3,5 Water flow limits for main coil (l/h) 3 rows 4 rows Model 13 23 33 14 24 34 Minimum Maximum 100 500 150 1000 150 1500 100 750 150 1000 200 2000 Water flow limits for additional coil (l/h) 1 row 2 rows Model 1 2 3 1 2 3 Minimum Maximum 50 250 100 450 100 650 50 250 100 450 100 650 1 2 3 66 0,30 71 0,32 84 0,38 Motor electrical data (max. absorption) Model 230/1 50Hz W A Air throw C1 - Heating L C2 - Cooling L Model Air throw L (m) C1 C2 Carisma Coanda CCN 1 Carisma Coanda CCN 2 Carisma Coanda CCN 3 1 1 1 2 3 4 5 6 3,8 4,5 5,8 6,3 6,8 7,2 4 3 3,6 4,6 5 5,4 5,7 3,2 2 5 4 3 4 5 6 2 3 4 5 6 6,1 7 8 9 4,5 5,2 6,3 7,5 8,8 9,5 4,8 5,6 6,4 7,2 3,6 4,1 5 6 7 7,6 7 CCN Version Carisma Coanda Emissions Cooling emission of 3 row coil Entering air temperature: +27°C - Relative Humidity: 50% WT: 7/12 °C Model CCN 13 CCN 23 CCN 33 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 1,73 1,62 1,46 1,36 1,14 0,95 3,47 3,03 2,54 2,12 1,74 1,47 4,36 4,03 3,59 3,05 2,55 2,11 1,27 1,18 1,06 0,97 0,81 0,66 2,46 2,13 1,77 1,46 1,19 1,00 3,06 2,82 2,50 2,10 1,74 1,44 298 279 251 234 196 163 597 521 437 365 299 253 750 693 617 525 439 363 7,8 7,0 5,8 5,1 3,8 2,7 14,9 11,7 8,6 6,3 4,4 3,3 25,8 22,5 18,4 13,8 10,0 7,2 1,54 1,44 1,30 1,21 1,02 0,85 3,12 2,72 2,29 1,91 1,57 1,32 3,91 3,63 3,23 2,75 2,30 1,91 1,19 1,11 0,99 0,92 0,76 0,62 2,32 2,00 1,66 1,37 1,12 0,94 2,88 2,65 2,35 1,98 1,64 1,35 265 248 224 208 175 146 537 468 394 329 270 227 673 624 556 473 396 329 6,3 5,6 4,7 4,2 3,1 2,2 12,2 9,6 7,1 5,2 3,6 2,7 21,2 18,6 15,2 11,4 8,3 6,0 1,14 1,07 0,97 0,91 0,77 0,64 2,36 2,06 1,74 1,46 1,20 1,02 2,98 2,77 2,47 2,11 1,77 1,47 1,04 0,97 0,86 0,80 0,66 0,54 2,02 1,74 1,45 1,19 0,97 0,81 2,51 2,31 2,05 1,72 1,42 1,17 196 184 167 157 132 110 406 354 299 251 206 175 513 476 425 363 304 253 3,7 3,3 2,8 2,5 1,8 1,3 7,4 5,8 4,3 3,2 2,2 1,7 13,0 11,4 9,3 7,0 5,2 3,7 0,91 0,85 0,76 0,70 0,59 0,48 1,78 1,54 1,28 1,06 0,86 0,72 2,22 2,04 1,81 1,52 1,26 1,04 0,91 0,85 0,76 0,70 0,59 0,48 1,78 1,54 1,28 1,06 0,86 0,72 2,22 2,04 1,81 1,52 1,26 1,04 157 146 131 120 101 83 306 265 220 182 148 124 382 351 311 261 217 179 2,5 2,2 1,8 1,5 1,1 0,8 4,4 3,4 2,5 1,8 1,2 0,9 7,6 6,6 5,3 3,9 2,8 2,0 Entering air temperature: +26°C - Relative Humidity: 50% WT: 7/12 °C Model CCN 13 CCN 23 CCN 33 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 1,53 1,43 1,30 1,21 1,02 0,84 3,10 2,70 2,27 1,90 1,55 1,31 3,89 3,60 3,21 2,73 2,28 1,89 1,19 1,11 0,99 0,92 0,76 0,62 2,32 2,00 1,67 1,38 1,12 0,94 2,89 2,66 2,36 1,98 1,64 1,36 263 246 224 208 175 144 533 464 390 327 267 225 669 619 552 470 392 325 6,3 5,6 4,7 4,1 3,1 2,2 12,2 9,5 7,1 5,1 3,6 2,7 21,2 18,5 15,1 11,3 8,3 6,0 1,34 1,26 1,14 1,06 0,90 0,74 2,74 2,39 2,01 1,68 1,38 1,17 3,45 3,20 2,85 2,42 2,03 1,69 1,12 1,04 0,93 0,86 0,71 0,58 2,17 1,87 1,56 1,29 1,05 0,88 2,70 2,49 2,21 1,85 1,54 1,27 230 217 196 182 155 127 471 411 346 289 237 201 593 550 490 416 349 291 5,0 4,4 3,7 3,3 2,4 1,8 9,7 7,6 5,7 4,1 2,9 2,2 17,0 14,9 12,2 9,1 6,7 4,8 0,99 0,92 0,80 0,75 0,63 0,53 1,96 1,72 1,46 1,23 1,01 0,86 2,50 2,32 2,08 1,78 1,49 1,24 0,99 0,92 0,80 0,74 0,61 0,50 1,87 1,61 1,34 1,11 0,90 0,75 2,33 2,15 1,90 1,60 1,32 1,09 170 158 138 129 108 91 337 296 251 212 174 148 430 399 358 306 256 213 2,9 2,5 2,0 1,7 1,3 1,0 5,3 4,2 3,2 2,3 1,7 1,2 9,5 8,4 6,9 5,2 3,8 2,8 0,83 0,77 0,69 0,64 0,54 0,44 1,63 1,40 1,18 0,97 0,79 0,66 2,03 1,87 1,65 1,40 1,15 0,95 0,83 0,77 0,69 0,64 0,54 0,44 1,63 1,40 1,18 0,97 0,79 0,66 2,03 1,87 1,65 1,40 1,15 0,95 143 132 119 110 93 76 280 241 203 167 136 114 349 322 284 241 198 163 2,1 1,8 1,5 1,3 1,0 0,7 3,8 2,9 2,1 1,5 1,0 0,8 6,5 5,6 4,5 3,4 2,4 1,7 Entering air temperature: +25°C - Relative Humidity: 50% WT: 7/12 °C Model CCN 13 CCN 23 CCN 33 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 1,34 1,26 1,14 1,06 0,89 0,74 2,73 2,38 2,01 1,68 1,38 1,16 3,44 3,19 2,84 2,41 2,02 1,68 1,12 1,04 0,93 0,86 0,71 0,58 2,18 1,88 1,56 1,29 1,05 0,88 2,71 2,50 2,21 1,86 1,54 1,27 230 217 196 182 153 127 470 409 346 289 237 200 592 549 488 415 347 289 5,0 4,5 3,7 3,3 2,4 1,8 9,7 7,7 5,7 4,1 2,9 2,2 17,0 14,9 12,2 9,1 6,7 4,8 1,15 1,08 0,98 0,91 0,77 0,64 2,37 2,07 1,75 1,46 1,20 1,02 2,99 2,78 2,48 2,11 1,77 1,47 1,04 0,97 0,87 0,80 0,66 0,54 2,03 1,75 1,46 1,20 0,98 0,82 2,53 2,33 2,06 1,73 1,43 1,18 198 186 169 157 132 110 408 356 301 251 206 175 514 478 427 363 304 253 3,8 3,4 2,9 2,5 1,9 1,4 7,5 5,9 4,4 3,2 2,3 1,7 13,2 11,6 9,5 7,1 5,2 3,8 0,91 0,85 0,76 0,70 0,59 0,48 1,79 1,54 1,29 1,06 0,86 0,69 2,22 2,05 1,81 1,53 1,26 1,01 0,91 0,85 0,76 0,70 0,59 0,48 1,79 1,54 1,29 1,06 0,86 0,69 2,22 2,05 1,81 1,53 1,26 1,00 157 146 131 120 101 83 308 265 222 182 148 119 382 353 311 263 217 174 2,5 2,2 1,8 1,6 1,1 0,8 4,5 3,5 2,5 1,8 1,2 0,9 7,7 6,7 5,4 4,0 2,9 1,9 0,75 0,70 0,63 0,58 0,48 0,40 1,48 1,27 1,07 0,88 0,71 0,60 1,84 1,70 1,50 1,27 1,05 0,86 0,75 0,70 0,63 0,58 0,48 0,40 1,48 1,27 1,07 0,88 0,71 0,60 1,84 1,70 1,50 1,27 1,05 0,86 129 120 108 100 83 69 255 218 184 151 122 103 316 292 258 218 181 148 1,7 1,5 1,3 1,1 0,8 0,6 3,2 2,5 1,8 1,3 0,9 0,7 5,5 4,7 3,8 2,8 2,0 1,4 Legend WT = Water temperature = Cooling Total emission Pc = Cooling Sensible emission Ps Qw = Water flow Dp(c) = Water side pressure drop Speed MAX MED MIN Qv Correction factors for different R.H. U.R. 48% 46% 8 WT: Pc Ps Pc Ps 7/12°C 0,95 1,00 0,90 1,00 8/13°C 0,94 1,00 0,88 1,00 10/15°C 1,00 1,00 1,00 1,00 12/17°C 1,00 1,00 1,00 1,00 = Fan speed = High speed = Medium speed = Low speed = Air flow CCN Version Carisma Coanda Emissions Cooling emission of 4 row coil Entering air temperature: +27°C - Relative Humidity: 50% WT: 7/12 °C Model CCN 14 CCN 24 CCN 34 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 2,01 1,87 1,67 1,54 1,28 1,05 3,85 3,32 2,76 2,28 1,84 1,54 4,69 4,32 3,83 3,22 2,67 2,20 1,42 1,31 1,16 1,07 0,88 0,71 2,66 2,28 1,88 1,54 1,24 1,04 3,24 2,98 2,62 2,19 1,81 1,48 346 322 287 265 220 181 662 571 475 392 316 265 807 743 659 554 459 378 16,7 14,6 12,1 10,5 7,6 5,3 24,7 19,0 13,7 9,8 6,8 4,9 20,3 17,6 14,2 10,5 7,5 5,4 1,80 1,68 1,50 1,39 1,15 0,94 3,47 2,99 2,49 2,06 1,67 1,40 4,22 3,89 3,45 2,91 2,41 1,99 1,33 1,23 1,09 1,00 0,83 0,67 2,50 2,14 1,77 1,45 1,17 0,97 3,05 2,80 2,47 2,06 1,70 1,39 310 289 258 239 198 162 597 514 428 354 287 241 726 669 593 501 415 342 13,7 12,0 9,9 8,6 6,2 4,4 20,4 15,7 11,4 8,1 5,6 4,1 16,8 14,6 11,8 8,7 6,3 4,5 1,36 1,27 1,14 1,06 0,88 0,72 2,65 2,30 1,92 1,59 1,29 1,09 3,23 2,98 2,65 2,24 1,86 1,54 1,16 1,07 0,95 0,87 0,72 0,58 2,18 1,86 1,54 1,26 1,01 0,85 2,65 2,44 2,15 1,79 1,48 1,21 234 218 196 182 151 124 456 396 330 273 222 187 556 513 456 385 320 265 8,2 7,3 6,0 5,3 3,8 2,7 12,6 9,7 7,1 5,1 3,5 2,6 10,4 9,0 7,3 5,4 3,9 2,8 1,02 0,95 0,84 0,77 0,64 0,52 1,93 1,65 1,36 1,11 0,85 0,72 2,34 2,15 1,90 1,59 1,30 1,01 1,02 0,95 0,84 0,77 0,64 0,52 1,93 1,65 1,36 1,11 0,85 0,71 2,34 2,15 1,90 1,59 1,30 1,01 175 163 144 132 110 89 332 284 234 191 146 124 402 370 327 273 224 174 4,9 4,3 3,5 3,0 2,1 1,5 7,0 5,4 3,8 2,7 1,7 1,2 5,8 5,0 4,0 2,9 2,1 1,3 Entering air temperature: +26°C - Relative Humidity: 50% WT: 7/12 °C Model CCN 14 CCN 24 CCN 34 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 1,79 1,67 1,49 1,38 1,15 0,94 3,44 2,97 2,47 2,04 1,65 1,39 4,19 3,87 3,43 2,88 2,39 1,97 1,33 1,23 1,10 1,01 0,83 0,67 2,51 2,15 1,77 1,45 1,17 0,98 3,06 2,81 2,47 2,07 1,70 1,40 308 287 256 237 198 162 592 511 425 351 284 239 721 666 590 495 411 339 13,6 12,0 9,9 8,6 6,2 4,3 20,3 15,6 11,3 8,1 5,6 4,1 16,7 14,5 11,7 8,7 6,2 4,4 1,58 1,47 1,32 1,22 1,02 0,83 3,06 2,64 2,20 1,82 1,48 1,24 3,72 3,43 3,05 2,57 2,13 1,76 1,25 1,15 1,03 0,94 0,78 0,63 2,35 2,01 1,66 1,36 1,10 0,91 2,86 2,63 2,31 1,93 1,59 1,31 272 253 227 210 175 143 526 454 378 313 255 213 640 590 525 442 366 303 10,9 9,6 7,9 6,9 5,0 3,5 16,3 12,6 9,2 6,6 4,5 3,3 13,5 11,7 9,5 7,0 5,1 3,6 1,14 1,06 0,96 0,89 0,74 0,61 2,24 1,94 1,62 1,35 1,10 0,92 2,72 2,52 2,24 1,89 1,58 1,31 1,07 0,99 0,88 0,81 0,67 0,54 2,02 1,73 1,43 1,17 0,94 0,78 2,46 2,26 1,99 1,66 1,37 1,12 196 182 165 153 127 105 385 334 279 232 189 158 468 433 385 325 272 225 6,0 5,3 4,4 3,9 2,8 2,0 9,3 7,2 5,3 3,8 2,6 2,0 7,7 6,7 5,4 4,0 2,9 2,1 0,94 0,87 0,77 0,71 0,58 0,47 1,76 1,51 1,25 1,02 0,82 0,68 2,15 1,97 1,74 1,45 1,19 0,98 0,94 0,87 0,77 0,71 0,58 0,47 1,76 1,51 1,25 1,02 0,82 0,68 2,15 1,97 1,74 1,45 1,19 0,98 162 150 132 122 100 81 303 260 215 175 141 117 370 339 299 249 205 169 4,2 3,7 3,0 2,6 1,8 1,3 6,0 4,6 3,3 2,3 1,6 1,1 5,0 4,3 3,5 2,5 1,8 1,3 Entering air temperature: +25°C - Relative Humidity: 50% WT: 7/12 °C Model CCN 14 CCN 24 CCN 34 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 1,58 1,47 1,32 1,22 1,01 0,83 3,05 2,63 2,19 1,81 1,47 1,23 3,71 3,42 3,03 2,56 2,12 1,75 1,25 1,16 1,03 0,94 0,78 0,63 2,36 2,02 1,66 1,36 1,10 0,92 2,87 2,63 2,32 1,94 1,60 1,31 272 253 227 210 174 143 525 452 377 311 253 212 638 588 521 440 365 301 10,9 9,6 7,9 6,9 5,0 3,5 16,4 12,6 9,2 6,6 4,5 3,3 13,5 11,7 9,5 7,0 5,0 3,6 1,37 1,27 1,14 1,06 0,88 0,72 2,66 2,30 1,92 1,59 1,29 1,08 3,24 2,99 2,65 2,24 1,86 1,54 1,16 1,08 0,96 0,88 0,72 0,58 2,19 1,88 1,55 1,27 1,02 0,85 2,67 2,45 2,16 1,80 1,49 1,22 236 218 196 182 151 124 458 396 330 273 222 186 557 514 456 385 320 265 8,4 7,4 6,1 5,4 3,9 2,7 12,8 9,9 7,2 5,2 3,6 2,6 10,5 9,2 7,4 5,5 4,0 2,8 1,03 0,95 0,84 0,78 0,64 0,52 1,93 1,65 1,31 1,09 0,90 0,76 2,35 2,16 1,91 1,53 1,28 1,07 1,03 0,95 0,84 0,78 0,64 0,52 1,93 1,65 1,31 1,07 0,86 0,72 2,35 2,16 1,91 1,52 1,25 1,03 177 163 144 134 110 89 332 284 225 187 155 131 404 372 329 263 220 184 5,0 4,4 3,5 3,1 2,2 1,5 7,2 5,5 3,6 2,6 1,9 1,4 5,9 5,1 4,1 2,8 2,0 1,5 0,85 0,78 0,70 0,64 0,53 0,43 1,60 1,37 1,14 0,93 0,75 0,62 1,95 1,79 1,58 1,32 1,09 0,89 0,85 0,78 0,70 0,64 0,53 0,43 1,60 1,37 1,14 0,93 0,75 0,62 1,95 1,79 1,58 1,32 1,09 0,89 146 134 120 110 91 74 275 236 196 160 129 107 335 308 272 227 187 153 3,5 3,1 2,5 2,2 1,5 1,1 5,1 3,9 2,8 2,0 1,3 1,0 4,2 3,6 2,9 2,1 1,5 1,1 Correction factors for different R.H. U.R. 48% 46% WT: Pc Ps Pc Ps 7/12°C 0,95 1,00 0,90 1,00 8/13°C 0,94 1,00 0,88 1,00 10/15°C 1,00 1,00 1,00 1,00 12/17°C 1,00 1,00 1,00 1,00 Legend WT = Water temperature = Cooling Total emission Pc = Cooling Sensible emission Ps Qw = Water flow Dp(c) = Water side pressure drop Speed MAX MED MIN Qv = Fan speed = High speed = Medium speed = Low speed = Air flow 9 CCN Version Carisma Coanda Emissions Heating emission of 3 row coil Entering air temperature: +20°C WT: 70/60°C Model CCN 13 CCN 23 CCN 33 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 60/50°C WT: 50/40° WT: 50/45° WT: 45/40° Qv m3/h Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 3,54 3,29 2,94 2,71 2,26 1,84 6,64 5,77 4,79 3,95 3,20 2,68 8,20 7,61 6,73 5,65 4,67 3,85 304 283 253 233 194 158 571 496 412 340 275 230 705 654 579 486 402 331 6,3 5,6 4,6 4,0 2,9 2,0 10,7 8,3 6,0 4,3 2,9 2,2 18,0 15,8 12,7 9,4 6,7 4,8 2,71 2,51 2,25 2,07 1,73 1,41 5,10 4,43 3,68 3,03 2,46 2,07 6,30 5,85 5,18 4,35 3,60 2,96 233 216 194 178 149 121 439 381 316 261 212 178 542 503 445 374 310 255 4,1 3,6 2,9 2,5 1,9 1,3 6,9 5,4 3,9 2,8 1,9 1,4 11,7 10,3 8,3 6,1 4,4 3,1 1,87 1,74 1,56 1,44 1,20 0,98 3,55 3,09 2,57 2,12 1,72 1,45 4,40 4,09 3,62 3,04 2,52 2,08 161 150 134 124 103 84 305 266 221 182 148 125 378 352 311 261 217 179 2,2 1,9 1,6 1,4 1,0 0,7 3,8 3,0 2,1 1,5 1,1 0,8 6,4 5,6 4,6 3,4 2,4 1,7 2,16 2,01 1,80 1,66 1,38 1,12 4,06 3,52 2,93 2,41 1,95 1,64 5,01 4,65 4,11 3,45 2,85 2,35 372 346 310 286 237 193 698 605 504 415 335 282 862 800 707 593 490 404 9,5 8,4 6,9 6,0 4,3 3,0 16,1 12,5 9,0 6,4 4,4 3,3 27,1 23,8 19,2 14,1 10,1 7,2 1,75 1,62 1,45 1,34 1,12 0,91 3,29 2,86 2,38 1,96 1,59 1,33 4,07 3,77 3,34 2,80 2,32 1,91 301 279 249 230 193 157 566 492 409 337 273 229 700 648 574 482 399 329 6,7 5,9 4,8 4,2 3,0 2,1 11,3 8,8 6,4 4,5 3,1 2,3 19,1 16,8 13,5 9,9 7,1 5,1 Heating emission of 4 row coil Entering air temperature: +20°C WT: 70/60°C Model CCN 14 CCN 24 CCN 34 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 50/40° WT: 50/45° WT: 45/40° Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 3,80 3,52 3,14 2,89 2,37 1,92 7,46 6,37 5,22 4,25 3,40 2,82 8,72 8,00 7,04 5,87 4,83 3,96 327 303 270 249 204 165 642 548 449 366 292 243 750 688 605 505 415 341 11,7 10,2 8,4 7,2 5,1 3,5 18,2 13,8 9,7 6,7 4,5 3,3 13,9 12,0 9,6 6,9 4,9 3,5 2,92 2,70 2,42 2,22 1,83 1,48 5,75 4,92 4,03 3,28 2,63 2,18 6,71 6,16 5,42 4,52 3,72 3,06 251 232 208 191 157 127 495 423 347 282 226 187 577 530 466 389 320 263 7,6 6,6 5,5 4,7 3,3 2,3 11,8 9,0 6,3 4,4 3,0 2,2 9,1 7,8 6,2 4,5 3,2 2,3 2,03 1,88 1,69 1,55 1,28 1,03 4,04 3,46 2,84 2,31 1,85 1,54 4,70 4,31 3,80 3,18 2,62 2,15 175 162 145 133 110 89 347 298 244 199 159 132 404 371 327 273 225 185 4,2 3,6 3,0 2,6 1,8 1,3 6,6 5,0 3,5 2,5 1,7 1,2 5,0 4,3 3,4 2,5 1,8 1,3 2,32 2,15 1,92 1,77 1,45 1,17 4,56 3,90 3,19 2,60 2,08 1,73 5,33 4,89 4,30 3,59 2,95 2,42 399 370 330 304 249 201 784 671 549 447 358 298 917 841 740 617 507 416 17,7 15,4 12,7 10,9 7,7 5,3 27,3 20,7 14,6 10,1 6,9 4,9 20,9 18,0 14,4 10,4 7,4 5,2 1,88 1,74 1,56 1,43 1,18 0,95 3,71 3,17 2,60 2,12 1,69 1,41 4,33 3,97 3,40 2,92 2,40 1,97 323 299 268 246 203 163 638 545 447 365 291 243 745 683 585 502 413 339 12,4 10,8 8,9 7,7 5,4 3,7 19,4 14,7 10,4 7,2 4,9 3,5 14,8 12,7 10,2 7,4 5,3 3,7 Legend WT = Water temperature Ph = Emission Qw = Water flow Dp(c) = Water side pressure drop 10 WT: 60/50°C Qv m3/h Speed MAX MED MIN Qv = Fan speed = High speed = Medium speed = Low speed = Air flow CCN Version Carisma Coanda Emissions Heating emission of 1 row additional coil Entering air temperature: +20°C WT: 80/70°C Model CCN 13+1 14+1 CCN 23+1 24+1 CCN 33+1 CCN 34+1 Speed VI V IV III II I VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN MAX MED MIN WT: 75/65° WT: 70/60° WT: 65/55° WT: 60/50° WT: 55/45° Qv m3/h Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 680 620 540 440 360 290 1,95 1,83 1,67 1,57 1,35 1,15 3,84 3,41 2,94 2,52 2,14 1,86 4,84 4,53 4,10 3,57 3,07 2,64 4,84 4,53 4,10 3,57 3,07 2,64 168 157 144 135 116 99 330 293 253 217 184 160 416 390 353 307 264 227 416 390 353 307 264 227 5,8 5,2 4,4 3,9 3,0 2,3 4,7 3,8 2,9 2,2 1,7 1,3 8,2 7,3 6,2 4,8 3,7 2,8 8,2 7,3 6,2 4,8 3,7 2,8 1,75 1,65 1,51 1,41 1,22 1,03 3,46 3,07 2,65 2,27 1,93 1,68 4,36 4,08 3,70 3,22 2,77 2,38 4,36 4,08 3,70 3,22 2,77 2,38 151 142 130 121 105 89 298 264 228 195 166 144 375 351 318 277 238 205 375 351 318 277 238 205 4,9 4,4 3,7 3,3 2,5 1,9 3,9 3,2 2,5 1,9 1,4 1,1 7,0 6,2 5,2 4,1 3,1 2,4 7,0 6,2 5,2 4,1 3,1 2,4 1,56 1,47 1,34 1,25 1,08 0,92 3,07 2,73 2,35 2,02 1,71 1,49 3,89 3,64 3,30 2,87 2,47 2,12 3,89 3,64 3,30 2,87 2,47 2,12 134 126 115 108 93 79 264 235 202 174 147 128 335 313 284 247 212 182 335 313 284 247 212 182 4,0 3,6 3,1 2,7 2,1 1,6 3,2 2,6 2,0 1,6 1,2 0,9 5,8 5,1 4,3 3,4 2,6 2,0 5,8 5,1 4,3 3,4 2,6 2,0 1,36 1,28 1,17 1,10 0,95 0,81 2,37 2,10 1,82 1,57 1,33 1,16 3,41 3,19 2,89 2,52 2,17 1,86 3,41 3,19 2,89 2,52 2,17 1,86 117 110 101 95 82 70 204 181 157 135 114 100 293 274 249 217 187 160 293 274 249 217 187 160 3,2 2,9 2,5 2,2 1,7 1,3 1,0 0,8 0,6 0,5 0,4 0,3 4,7 4,1 3,5 2,7 2,1 1,6 4,7 4,1 3,5 2,7 2,1 1,6 1,17 1,10 1,00 0,94 0,81 0,69 2,31 2,05 1,77 1,52 1,29 1,13 2,94 2,75 2,49 2,17 1,87 1,61 2,94 2,75 2,49 2,17 1,87 1,61 101 95 86 81 70 59 199 176 152 131 111 97 253 237 214 187 161 138 253 237 214 187 161 138 2,5 2,2 1,9 1,7 1,3 1,0 2,0 1,6 1,3 1,0 0,7 0,6 3,6 3,2 2,7 2,1 1,6 1,3 3,6 3,2 2,7 2,1 1,6 1,3 0,97 0,92 0,84 0,78 0,68 0,58 1,93 1,71 1,48 1,27 1,08 0,94 2,46 2,31 2,09 1,82 1,57 1,35 2,46 2,31 2,09 1,82 1,57 1,35 83 79 72 67 58 50 166 147 127 109 93 81 212 199 180 157 135 116 212 199 180 157 135 116 1,8 1,6 1,4 1,3 1,0 0,7 1,5 1,2 0,9 0,7 0,5 0,4 2,7 2,4 2,0 1,6 1,2 0,9 2,7 2,4 2,0 1,6 1,2 0,9 Heating emission of 2 row additional coil Entering air temperature: +20°C WT: 65/55°C Model CCN 13+2 CCN 23+2 CCN 33+2 Speed VI V IV III II I VI V IV III II I VI V IV III II I MAX MED MIN MAX MED MIN MAX MED MIN WT: 60/50° WT: 55/45° WT: 50/40° WT: 45/40° WT: 45/35° Qv m3/h Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 305 280 245 220 180 140 560 470 380 305 240 200 680 620 540 440 360 290 2,38 2,23 2,02 1,88 1,60 1,35 4,66 4,08 3,47 2,95 2,43 2,07 5,83 5,42 4,86 4,20 3,54 2,96 205 192 174 162 138 116 401 351 298 254 209 178 501 466 418 361 304 255 15,5 13,8 11,6 10,3 7,7 5,7 12,7 10,1 7,6 5,7 4,1 3,1 22,5 19,8 16,3 12,6 9,3 6,8 2,05 1,92 1,75 1,63 1,38 1,16 4,03 3,53 3,00 2,55 2,11 1,79 5,06 4,70 4,22 3,65 3,07 2,57 176 165 151 140 119 100 347 304 258 219 181 154 435 404 363 314 264 221 12,2 10,8 9,1 8,1 6,0 4,5 10,0 8,0 6,0 4,5 3,2 2,4 17,8 15,6 12,9 10,0 7,4 5,4 1,73 1,62 1,47 1,37 1,16 0,98 3,40 2,99 2,54 2,16 1,78 1,52 4,28 3,98 3,57 3,09 2,60 2,18 149 139 126 118 100 84 292 257 218 186 153 131 368 342 307 266 224 187 9,2 8,2 6,9 6,1 4,6 3,4 7,6 6,0 4,5 3,4 2,4 1,8 13,5 11,8 9,8 7,6 5,6 4,1 1,41 1,32 1,20 1,12 0,95 0,80 2,78 2,44 2,09 1,77 1,46 1,25 3,50 3,26 2,92 2,53 2,14 1,79 121 114 103 96 82 69 239 210 180 152 126 108 301 280 251 218 184 154 6,5 5,8 4,9 4,3 3,2 2,4 5,4 4,3 3,3 2,4 1,7 1,3 9,6 8,5 7,0 5,4 4,0 3,0 1,33 1,25 1,13 1,05 0,89 0,75 2,61 2,29 1,96 1,65 1,36 1,16 3,27 3,04 2,72 2,36 1,98 1,66 229 215 194 181 153 129 449 394 337 284 234 200 562 523 468 406 341 286 20,0 17,8 15,0 13,3 9,9 7,4 16,5 13,1 10,0 7,4 5,3 4,0 29,1 25,6 21,1 16,4 12,1 8,8 1,09 1,02 0,92 0,86 0,73 0,62 2,15 1,89 1,62 1,37 1,14 0,97 2,73 2,54 2,28 1,98 1,67 1,40 94 88 79 74 63 53 185 163 139 118 98 83 235 218 196 170 144 120 4,2 3,7 3,1 2,8 2,1 1,6 3,5 2,8 2,1 1,6 1,1 0,9 6,3 5,6 4,6 3,6 2,7 1,9 Legend WT = Water temperature Ph = Emission Qw = Water flow Dp(c) = Water side pressure drop Speed MAX MED MIN Qv = Fan speed = High speed = Medium speed = Low speed = Air flow 11 Water side pressure drop 3 row coil 4 row coil Dp Dp 50 50 40 40 3 30 CCN Version Carisma Coanda 30 20 2 20 3 2 10 9 8 10 9 8 7 7 6 6 5 5 1 4 4 3 3 2 2 1 100 200 1 300 400 600 800 1000 1500 1 Qw Pressure drop for mean water temperature of 10°C; for different temperatures multiply the pressure drop figure by the K correction factors in the table. 100 °C K 200 20 0,94 30 0,90 1 row additional coil 40 0,86 600 50 0,82 800 1000 1500 60 0,78 Qw 70 0,74 80 0,70 Dp 60 60 50 50 40 40 30 30 20 20 10 9 8 7 6 10 9 8 7 6 3 5 5 4 4 3 2 1 3 1 2 2 2 1 50 60 80 100 200 300 400 600 800 1000 Legend Qw = water flow (l/h) Dp = pressure drop (kPa) 1 Qw Pressure drop for mean water temperature of 65°C; for different temperatures multiply the pressure drop figure by the K correction factors in the table. 12 400 2 row additional coil Dp 3 300 50 60 °C K 80 100 40 1,14 200 50 1,08 300 400 60 1,02 600 800 1000 70 0,96 Qw 80 0,90 CCN Version Carisma Coanda Accessories VBP Main coil 3 way valve VBA Additional coil 3 way valve Control valve kit:3 way valve, ON-OFF, with electric motor and mounting kit with micrometric lockshield valve. Control valve kit:3 way valve, ON-OFF, with electric motor and mounting kit with micrometric lockshield valve. VS Simplified kit for 3 way valve for main and additional coil V2 2 way valve for main and additional coil 3 way valve, (ON-OFF) with electric motor and mounting kit. Valve with flat connection without micrometric lockshield valve. Control valve kit: 2 way valve, ON-OFF, with electric motor and mounting kit. Valve type mod. Main 1-2 DN (Ø) Kvs Micrometric lockshield valve DN (Ø) Kvs 15 1/2" 1,6 15 Valve 1/2" 2 Code Fitted Not Fitted 9066561H 9066560H VBP VBA Valves pressure drop Kvs 2 Dp 3 20 3/4" 2,5 15 1/2" 2 9060471H 9060474H Additional All 15 1/2" 1,6 15 1/2" 2 9060472H 9060475H 1-2 15 1/2" 1,6 - - - 9066571H 9066570H 3 20 3/4" 2,5 - - - 9060484H 9060481H 4 All 15 1/2” 1,6 - - - 9060483H 9060480H 2 1-2 15 1/2" 1,7 - - - 9060476H 9060478H 1 3 20 3/4" 2,8 - - - 9060477H 9060479H All 15 1/2” 1,7 - - - 9060476H 9060478H Main Additional Kvs 1,6 Kvs 2,5 Kvs 2,8 40 Main VS Kvs 1,7 30 20 10 9 8 7 6 5 3 100 200 300 400 600 800 1000 2000 3000 4000 Main V2 Additional Qw Legend Qw = water flow (l/h) Dp = pressure drop (kPa) 13 CCN Version Carisma Coanda Accessories BEL Electric heater 1 PHASE 230V Electric heater with integral: safety thermostat and relay control. ID Size Watt Code BEL 1 350 9064051 2 550 9064031 700 9064052 3 1150 9064032 900 9064053 1400 9064033 BSO Extension condensate collection tray to cover valve assembly Connection side ID Code left BSO BSO-SX 6060402 right BSO-DX 6060403 SCR plastic condensate drain pipe with fast connection It helps regular drainage of condensate thereby preventing the formation of bends. ID Code SCR 6060420 PCC condensate drain pump ID Fitted PCC-M Not fitted PCC-S Code 9064011 9064010 Height for vertical flow (m) 1 2 3 4 Water flow (l/h) depending on the length of horizontal flow 5m 10 m 6,8 6,3 5,5 5,0 4,2 3,8 3,0 2,6 FRC fresh air connection Code FRC 100 ID 6064191 Code TCX 3.9 x 9.5 6064192 TCX 3.9 x 9.5 98 14 FRC 120 122 ID CONTROL IDENTIFICATION CONTROL CODES Installation of bimetallic low temperature CUT-OUT thermostat (TMM) Installation of electronic low temperature CUT-OUT thermostat (TME) Room thermostat for fan and electric heater control Room thermostat for chilled water valve (SUMMER) and electric heater (WINTER) control (in winter only the heater is working) Simultaneous thermostatic control of the valves and fan Room thermostat for 2 valve control (4 pipe installation) Room thermostat for 1 valve control (2 pipe installation) Room thermostat for fan control (ON-OFF) Automatic Summer/Winter switch with neutral zone for 4 pipe installation with 2 valves Remote centralized Summer/Winter switch or by an automatic change-over fitted on the water pipe Summer/Winter switch Manual/Automatic 3 speed selection Manual 3 speed switch ON-OFF switch for electric heater ON-OFF switch CONTROL OPERATIONS Control operations Carisma Coanda CCN Version Electrical diagrams are shown on the installation, use and maintenance manual T2T 9060174 TMO-DI 9060165 TMO-503-SV2 9060173 TMO-503-S 9060171 TMO-T-AU 9060164 TMO-T 9060161 CR-T 9066330 MO-3V 9060160 15 Carisma Coanda Wall electronic controls ID Code MO-3V 9060160 CCN Version • ON-OFF switch and speed switch, without thermostatic control. • It allows to control the low temperature cut-out thermostat (TMM). Dimensions: 133x93x37 mm ID Code CR-T 9066330 • • • • • • Manual speed switch. Manual Summer/Winter switch. Electronic thermostat for fan control (ON-OFF). Electronic thermostat for valve control (ON-OFF). It allows to control the low temperature cut-out thermostat (TMM). It allows to control the chilled water valve (ON-OFF) and the electric heater (BEL) only in case that hot water is not used in winter (otherwise please use TMO-T-IAQ control with on/off switch for the electric heater described in the Carisma Fan Coil units technical documentation). Dimensions: 133x93x37 mm ID Code TMO-T 9060161 • • • • • • Manual speed switch. Manual Summer/Winter switch. Electronic thermostat for fan control (ON-OFF). Electronic thermostat for valve control (ON-OFF). It allows to control the low temperature cut-out thermostat (TME). It allows to control the chilled water valve (ON-OFF) and the electric heater (BEL) only in case that hot water is not used in winter (otherwise please use TMO-T-IAQ control with on/off switch for the electric heater described in the Carisma Fan Coil units technical documentation). • It allows to install the Summer/Winter switch centralized and remote, or to control it with an automatic change-over fitted on the water pipe (for 2-pipe systems only). The latter case needs the adjustment of the jumper on the control board (see the instruction leaflet supplied with the control). Dimensions: 133x93x37 mm ID Code TMO-T-AU 9060164 Dimensions: 133x93x37 mm • • • • • • • Manual or automatic speed switch. Manual Summer/Winter switch. Electronic thermostat for fan control (ON-OFF). Electronic thermostat for valve control (ON-OFF). Simultaneus thermostatic control on the valves and fan (ON-OFF). It allows to control the low temperature cut-out thermostat (TME). It allows to control the chilled water valve (ON-OFF) and the electric heater (BEL) only in case that hot water is not used in winter (otherwise please use TMO-T-AU-IAQ control with on/off switch for the electric heater described in the Carisma Fan Coil units technical documentation). • It allows to install the Summer/Winter switch centralized and remote, or to control it with an automatic change-over fitted on the water pipe (for 2-pipe systems only). The latter case needs the adjustment of the jumper on the control board (see the instruction leaflet supplied with the control). Note: with 4-pipe systems and continuous chilled and hot water supply, it allows the automatic summer/winter change-over in accordance to the room temperature (-1°C = Winter, +1°C = Summer, Dead Zone 2°C). 16 Carisma Coanda Wall electronic controls ID Code TMO-503-S 9060171 CCN Version The TMO-503-S control for fan coils without valves, is designed to be installed in a DIN 503 wall box. The control is supplied integral with the external frame, but it is possible to use frames of the most known brand on the market (BTicino, Vimar, AVE, Gewiss). The highest working electric absorbtion is 200 W; if the fan coil has an higher absorbtion or more units are connected to the same control, the speed switch SEL-S must be installed. • Manual or automatic speed switch. • Manual Summer/Winter switch. • Electronic thermostat for fan control (ON-OFF). •It allows to control the low temperature cut-out thermostat (included with the control). Dimensions: 118x87x8 mm ID Code TMO-503-SV2 9060173 The TMO-503-SV2 control for fan coils with valves, is designed to be installed in a DIN 503 wall box. The control is supplied integral with the external frame, but it is possible to use frames of the most known brand on the market (BTicino, Vimar, AVE, Gewiss). The highest working electric absorbtion is 200 W; if the fan coil has an higher absorbtion or more units are connected to the same control, the speed switch SEL-S must be installed. • • • • • Dimensions: 118x87x8 mm ID Code TMO-DI 9060165 Dimensions on the wall: 133x93x27 mm Dimensions in the DIN 503 box: 133x93x18 mm ID Code T2T 9060174 Manual or automatic speed switch. Manual Summer/Winter switch. Electronic thermostat for valve(s) control (ON-OFF). Simultaneus thermostatic control on the valves and fan (ON-OFF).. It allows to control the low temperature cut-out thermostat (included with the control). Note: with 4-pipe systems and continuous chilled and hot water supply, it allows the automatic summer/winter change-over in accordance to the room temperature (-1°C = Winter, +1°C = Summer, Dead Zone 2°C). To be installed on the wall or in the DIN 503 box. • Manual or automatic speed switch. • Manual or automatic Summer/Winter switch. • Electronic thermostat for fan control (ON-OFF). • Electronic thermostat for valve control (ON-OFF). • Simultaneus thermostatic control on the valves and fan (ON-OFF). • It allows to control the low temperature cut-out thermostat (TME). • It allows to control the chilled water valve (ON-OFF) and the electric heater (BEL) only in case that hot water is not used in winter. • It allows to control the fan and the heating electric resistance. • It allows to control up to 10 units with SEL-DI speed switch. Note: with 4-pipe systems and continuous chilled and hot water supply, it allows the automatic summer/winter change-over in accordance to the room temperature (-1°C = Winter, +1°C = Summer, Dead Zone 2°C). 2-pipes units only • • • • • • • ON-OFF switch. 3 speed switch. Manual Summer/Winter switch. Electronic thermostat for fan control. Thermostatic control on the valve and continuous fan operation. Simultaneus thermostatic control on the valves and fan. Cannot be used with speed switch (master-slave). Dimensions: 128x75x25 mm 17 Speed switches ID Code SEL-S 9079110 • Speed switch (slave). • It allows to control up to 8 units with only one centralized thermostat using one speed switch for each unit. • For controls: CR-T, MO-T, TMO-T-AU, TMO-503-S and TMO-503-SV2. ID Code SEL-DI 9060139 • Repeater for TMO-DI • It allows to control up to 10 units with only one TMO-DI centralized thermostat. 18 Carisma Coanda CCN Version Electronic control accessories Carisma Coanda CCN Version TME low temperature cut-out thermostat ID Code TME 3021091 To be fitted between the coil fins. When connecting the control, the TME probe cable must be separated from the power supply wires. To be used with the following controls: TMO-T, TMO-T-AU, TMO-DI. It stops the fan when the water temperature is lower than 38°C and it starts the fan when is higher than 42°C. TMM low temperature cut-out thermostat ID Code TMM 9053048 To be installed in contact with the hot water circuit. To be used with the following controls only: MO-3V, CR-T. For units working on heating only. It stops the fan when the water temperature is lower than 30°C and it starts the fan when is higher than 38°C. A Legend B A = red B = brown Change-Over CH 15-25 ID Code CH 15 -25 9053049 Automatic summer/winter switch to be installed in contact with the water circuit. For 2-tube installations only (not to be used with 2 way valve). To be used with the following controls only: TMO-T, TMO-T-AU, TMO-DI. A Legend B A = red B = black 19 CCN Version Carisma Coanda FreeSabiana Wireless control system Free Sabiana Free Sabiana is an innovative, fully wireless electronic system for use with fan coil units, based on radio communication. This technology provides installation flexibility and a more accurate measurement of the room temperature. The probe can be moved until the most suitable position is found, without the worry of changes in the environment layout and of its furniture and also without mounting it on a wall. If a new fan coil unit is added, no electrical wiring for the control system is required: just define the control unit and the probe which regulates it. The improved measurement accuracy derives from the possibility to position the probe near the typical location of the user: this enables to keep the temperature exactly at the required value with more energy savings compared with a traditional measurement system. Transmission is based on communication protocol IEE802.15.4, the most suitable way to transmit a relatively low amount of information with very low consumption and high reliability. The system has been certified by a leading independent body, officially recognized by the EU authorities and its sale has been authorized in all the EU and EFTA countries. Main components Free Sabiana includes 3 main components: • A remote control which features a button panel and LCD display and can be wall mounted or positioned on a dedicated table support. It enables the control of all the operating variables of the fan coil units in different configurations. The control is battery powered. The temperature and the operating speed of the fan coil unit are set with two large buttons featuring user friendly graphics. Description Remote control ID Code Free-Com 9060572 Control unit with support • A power unit to be installed on the fan coil (fan coil interface). It controls the fan and the valves of the fan coil. The power unit is connected to the electric supply. The power unit receives the information required to control the fan coil both from the remote control and locally, such as the temperature of the coil. Description Power unit fitted on the unit Power unit not fitted on the unit ID Code Free-Upm Free-Ups 9060571 9060570 Power unit • A room temperature probe, which can be wall mounted or positioned on a dedicated table support. It is a battery powered device, able to measure the air temperature in the spot where it is positioned, generating temperature information which is communicated to the other devices. Description Temperature probe ID Code Free-Sen 9060573 Probe with support 20 FreeSabiana Wireless control system Carisma Coanda CCN Version Main features of the remote control The control enables: • Fan coil on/off switching •Fan speed selection (high - medium - low - automatic) •Summer/winter operation selection •Valve on/off •Real time clock setting •Temperature setting •Daily switch on/off setting (timer function) •Enable/disable the timer function •Activation of the (eventual) electrostatic filter •Activation of the (eventual) electric resistance Main information displayed: 1 = On-off status 2 = Summer operation 3 = Winter operation 4 = Automatic season change 5 = Electric resistance 6 = Crystall filter 7 = Room temperature (with decimal accuracy) 8 = Fan operating speed 9 = Required/measured temperature 10= Timer 11= Clock 12= Transmission signal 13= Battery level Main features of the power unit to be installed on the fan coil The power unit controls the fan and the valves of the fan coil. The power unit receives the information required to control such units both from the remote control and locally. It enables the following main actions: •Fan on/off at a set speed •Fan speed change (fan on/off) •Water valve/s on/off (1 valve for 2 tube system - 2 valves for 4 tube system) •Fan speed change operating the water valve/s •Control of the electric resistance as main heating unit or as integration to the battery supplied with hot water •Control of the operation of the electrostatic filter (in parallel to the fan) •Management of the dead zone function for 4-tube systems •Available functional inputs: - Consent for remote on/off - Consent for remote Summer/Winter switch (centralized) - Consent for the activation of the Energy Saving function with setting change - Minimum probe - Probe for season change Main features of the temperature probe This device is able to measure the temperature of the air in the spot where it is positioned and to transmit it by means of radio communication to the other devices in the system. It is battery powered and can be freely positioned in the area to be air-conditioned. Display: •Measured environment temperature •Transmission signal •Clock •Battery status 21 CCN Version Carisma Coanda Controls and units MB version All the Carisma Coanda units can be supplied with a wide range of controls, which allows managing one single unit or several units by using the Modbus RTU - RS 485 communication protocol. Units can be managed according to the Master/Slave logic (up to 20 units) or by supervisory components. The system consists in a MB board and a series of controls, such as the T-MB wall control, the RT03 infra-red remote control, the PSM-DI multifunction control and the Sabianet supervisory program. T-MB Wall control PSM-DI Multifunction control PC Sabianet Screenshot RT03 Infra-red remote control Sabianet Software All the controls for the ECM version and their functions are described in detail from Page 39. 22 Coanda ECM Coanda ECM Carisma Coanda CCN-ECM Version ECM Version One Way Cassette Fan Coil with EC Brushless Electronic Motor and Inverter Board Constructional features of the main components Casing Made from 1 mm galvanized steel insulated with polyolefin (PO) foam (class M1). Diffuser with intake grille In prepainted metal sheet in RAL 9003 colour with intake grille that can be opened for inspection and maintenance of the air filter. Air Filter Polypropylene cellular fabric regenerating filter. Fan Assembly The fans have aluminium or plastic blades directly keyed on the motor with double aspiration and they are dynamically and statically balanced during manufacture in order to have an extremely quiet operation. Electronic motor Three phase permanent magnet brushless electronic motor that is controlled with current reconstructed according to a BLAC sinusoidal wave. The inverter board that controls the motor operation is powered by 230 Volt, single-phase and, with a switching system, it generates a three-phase frequency modulated, wave form power supply. The electric power supply required for the machine is therefore single-phase with voltage of 230-240V and frequency of 50-60Hz. Heat exchange coil It is manufactured from drawn copper tube and the aluminium fins are mechanically bonded onto the tube by an expansion process. The coil has two 1/2 inch BSP internal connections and 1/8 inch BSP air vent and drain. The heat exchanger is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. The connection side cannot be changed on site. Condensate Collection Tray Made from plastic (ABS UL94 HB), with an “L”-shape fitted on the inner casing; the try is insulated with polyolefin (PO) foam (class M1). The outside diameter of the condensate discharge pipe is 15mm. Round diffuser The Carisma Coanda one-way cassette units are supplied with round diffusers suitably designed to generate an airflow with “coanda” effect. The direction of diffuser air flow can be adjusted on site. 23 Dimensions, Weight, Water content Carisma Coanda Gr 1 - 3 diffusers Carisma Coanda CCN-ECM Version Carisma Coanda Gr 2 - 5 diffusers A 592 592 A Carisma Coanda Gr 3 - 6 diffusers 592 A Water inlet Water outlet Coil connections on the left 24 Dimensions, weight Water content Carisma Coanda CCN-ECM Version W 730 370 DIMENSIONS (mm) Model A E F W 1 2 3 592 454 78 750 970 884 43 1130 1192 1099 46,5 1350 weight (kg) Model Rows 3 3+1 3+2 4 4+1 1 Weight packed unit 2 3 Weight unpacked unit 1 2 3 18 20 23 20 23 34 40 46 37 42 44 51 58 48 54 16 19 22 18 21 33 38 43 35 40 42 48 54 45 51 Water content (l) Rows Model 3 4 +1 +2 1 2 3 0,6 0,8 0,2 0,4 1,3 1,7 0,4 0,8 1,7 2,4 0,5 1,0 25 Carisma Coanda EUROVENT certifications CCN-ECM Version www.eurovent-certification.com www.certiflash.com Technical features 2-pipe units The following standard rating conditions are used: COOLING (summer operation) Entering air temperature: + 27°C d.b. / + 19°C w.b. Water temperature: + 7°C E.W.T. / + 12°C L.W.T. Model HEATING (winter operation) Entering air temperature: + 20°C Water temperature: + 50°C E.W.T. Water flow rate as for the cooling conditions CCN-ECM 13 dB(A) 1 (E) MIN 130 0,82 0,62 1,02 2,1 1,7 8 35 26 Air flow m3/h Cooling total emission (E) kW Cooling sensible emission (E) kW Heating (E) kW ∆P Cooling (E) kPa ∆P Heating (E) kPa Fan (E) W Sound power (E) Lw dB(A) Sound pressure (*) Lp dB(A) 1 (E) MIN 130 0,91 0,66 1,07 4,1 3,3 8 35 26 Speed Air flow Cooling total emission (E) Cooling sensible emission (E) Heating (E) ∆P Cooling (E) ∆P Heating (E) Fan (E) m3/h kW kW kW kPa kPa W Sound power (E) Lw dB(A) Sound pressure (*) Lp Model 3 165 1,00 0,76 1,25 3,0 2,4 11 41 32 5 (E) MED 205 1,18 0,91 1,50 4,0 3,3 14 46 37 7,5 250 1,37 1,07 1,75 5,2 4,3 21 51 42 CCN-ECM 23 10 (E) MAX 295 1,56 1,24 2,02 6,5 5,3 29 55 46 1 (E) MIN 215 1,46 1,07 1,72 3,2 2,6 8 34 25 10 (E) MAX 295 1,81 1,38 2,20 13,9 11,6 29 55 46 1 (E) MIN 215 1,55 1,11 1,82 5,0 4,1 8 34 25 CCN-ECM 14 Speed 3 165 1,12 0,82 1,32 5,9 4,8 11 41 32 5 (E) MED 205 1,34 0,99 1,60 8,1 6,6 14 46 37 7,5 250 1,58 1,18 1,90 10,9 9,0 21 51 42 3 295 1,92 1,42 2,28 5,2 4,2 11 40 31 5 (E) MED 370 2,31 1,73 2,79 7,3 6,0 16 46 37 7,5 450 2,74 2,07 3,33 9,8 8,0 24 52 43 CCN-ECM 33 10 (E) MAX 540 3,16 2,41 3,85 12,6 10,4 37 56 47 1 (E) MIN 275 1,87 1,37 2,19 5,8 4,7 10 36 27 10 (E) MAX 540 3,50 2,60 4,32 20,8 17,1 37 56 47 1 (E) MIN 275 1,95 1,41 2,25 4,3 3,5 10 36 27 CCN-ECM 24 3 295 2,06 1,49 2,46 8,2 6,7 11 40 31 5 (E) MED 370 2,51 1,84 3,03 11,6 9,4 16 46 37 7,5 450 3,00 2,21 3,68 15,9 13,2 24 52 43 3 345 2,31 1,70 2,72 8,4 6,9 13 42 33 5 (E) MED 430 2,78 2,06 3,30 11,7 9,4 19 48 39 7,5 525 3,28 2,45 3,93 15,7 12,9 29 54 45 10 (E) MAX 620 3,75 2,83 4,54 19,8 16,6 42 58 49 CCN-ECM 34 3 345 2,42 1,76 2,82 6,4 5,2 13 42 33 5 (E) MED 430 2,94 2,15 3,44 8,9 7,4 19 48 39 7,5 525 3,49 2,57 4,12 12,1 10,0 29 54 45 10 (E) MAX 620 4,02 2,98 4,78 15,5 13,0 42 58 49 4-pipe units The following standard rating conditions are used: COOLING (summer operation) Entering air temperature: + 27°C d.b. / + 19°C w.b. Water temperature: + 7°C E.W.T. / + 12°C L.W.T. Model HEATING (winter operation) Entering air temperature: + 20°C Water temperature: + 70°C E.W.T. / + 60°C L.W.T. CCN-ECM 13 + 1 Speed Air flow Cooling total emission (E) Cooling sensible emission (E) Heating (E) ∆P Cooling (E) ∆P Heating (E) Fan (E) m3/h kW kW kW kPa kPa W Sound power (E) Lw dB(A) Sound pressure (*) Lp dB(A) 1 (E) MIN 130 0,82 0,62 0,87 2,1 1,4 8 35 26 3 165 1,00 0,76 1,03 3,0 1,9 11 41 32 5 (E) MED 205 1,18 0,91 1,18 4,0 2,5 14 46 37 7,5 250 1,37 1,07 1,35 5,2 3,1 21 51 42 CCN 23-ECM + 1 10 (E) MAX 295 1,56 1,24 1,52 6,5 3,8 29 55 46 1 (E) MIN 215 1,46 1,07 1,58 3,2 1,0 8 34 25 3 295 1,92 1,42 1,97 5,2 1,5 11 40 31 5 (E) MED 370 2,31 1,73 2,31 7,3 2,0 16 46 37 7,5 450 2,74 2,07 2,66 9,8 2,5 24 52 43 CCN 33-ECM + 1 10 (E) MAX 540 3,16 2,41 3,01 12,6 3,1 37 56 47 1 (E) MIN 275 1,87 1,37 2,04 5,8 1,8 10 36 27 3 345 2,31 1,70 2,42 8,4 2,5 13 42 33 5 (E) MED 430 2,78 2,06 2,82 11,7 3,3 19 48 39 7,5 525 3,28 2,45 3,24 15,7 4,2 29 54 45 10 (E) MAX 620 3,75 2,83 3,64 19,8 5,1 42 58 49 (E) = Eurovent certified performance. (*) = The sound pressure levels are 9 dB(A) lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. 26 CCN-ECM Version Carisma Coanda Working conditions and Air throw Working conditions Max. entering water temperature..................... + 80 °C MIn. entering water temperature........................ + 5 °C for entering water temperatures below + 5°C, contact “SABIANA” technical department Max. rated pressure............................................1000 kPa (10 bars) Installation height (m) Model 1 2 3 Minimum Maximum 2,6 3,2 2,6 3,2 2,6 3,5 Water flow limits for main coil (l/h) 3 rows 4 rows Model 13 23 33 14 24 34 Minimum Maximum 100 500 150 1000 150 1500 100 750 150 1000 200 2000 Water flow limits for additional coil (l/h) 1 row 2 rows Model 1 2 3 1 2 3 Minimum Maximum 50 250 100 450 100 650 50 250 100 450 100 650 1 2 3 29 37 42 Motor electrical data (max. absorption) Model 230/1 50Hz W Air throw C1 - Heating L C2 - Cooling L Carisma Coanda CCN-ECM 1 Model Air throw L (m) 1 C1 C2 2 3 4 5 Carisma Coanda CCN-ECM 2 6 1 3,8 4,5 5,8 6,3 6,8 7,2 4 3 3,6 4,6 5 5,4 5,7 3,2 2 5 4 3 4 5 Carisma Coanda CCN-ECM 3 6 1 2 3 4 5 6 6,1 7 8 9 4,5 5,2 6,3 7,5 8,8 9,5 4,8 5,6 6,4 7,2 3,6 4,1 5 6 7 7,6 27 CCN-ECM Version Carisma Coanda Emissions Cooling emission of 3 row coil Entering air temperature: +27°C - Relative Humidity: 50% WT: 7/12 °C Model CCN-ECM 13 CCN-ECM 23 CCN-ECM 33 WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Vdc Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 1,69 1,48 1,27 1,08 0,89 3,40 2,94 2,49 2,06 1,57 4,03 3,53 2,99 2,48 2,01 1,23 1,07 0,91 0,76 0,62 2,41 2,06 1,73 1,42 1,07 2,82 2,45 2,06 1,70 1,37 291 255 218 186 153 585 506 428 354 270 693 607 514 427 346 7,5 6,0 4,6 3,4 2,4 14,3 11,1 8,3 5,9 3,7 22,5 17,8 13,3 9,6 6,6 1,50 1,32 1,14 0,97 0,80 3,05 2,64 2,23 1,85 1,42 3,63 3,17 2,69 2,24 1,82 1,16 1,01 0,85 0,71 0,58 2,26 1,94 1,62 1,33 1,01 2,65 2,30 1,93 1,59 1,28 258 227 196 167 138 525 454 384 318 244 624 545 463 385 313 6,1 4,8 3,7 2,8 2,0 11,7 9,1 6,8 4,9 3,0 18,6 14,7 11,0 7,9 5,5 1,11 0,98 0,85 0,72 0,60 2,31 2,01 1,70 1,42 1,09 2,77 2,43 2,06 1,72 1,40 1,01 0,88 0,74 0,62 0,51 1,97 1,69 1,41 1,16 0,87 2,31 2,01 1,68 1,39 1,12 191 169 146 124 103 397 346 292 244 187 476 418 354 296 241 3,5 2,8 2,2 1,7 1,2 7,1 5,5 4,2 3,0 1,9 11,4 9,0 6,8 4,9 3,4 0,89 0,77 0,65 0,55 0,45 1,74 1,49 1,25 1,03 0,77 2,04 1,77 1,49 1,23 0,98 0,89 0,77 0,65 0,55 0,45 1,74 1,49 1,25 1,03 0,77 2,04 1,77 1,49 1,23 0,98 153 132 112 95 77 299 256 215 177 132 351 304 256 212 169 2,3 1,8 1,4 1,0 0,7 4,3 3,2 2,4 1,7 1,0 6,6 5,1 3,8 2,7 1,8 Entering air temperature: +26°C - Relative Humidity: 50% WT: 7/12 °C Model CCN-ECM 13 CCN-ECM 23 CCN-ECM 33 WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Vdc Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 1,49 1,31 1,13 0,96 0,79 3,03 2,63 2,22 1,84 1,41 3,60 3,15 2,67 2,22 1,80 1,16 1,01 0,85 0,72 0,58 2,27 1,95 1,63 1,34 1,01 2,66 2,31 1,94 1,60 1,29 256 225 194 165 136 521 452 382 316 243 619 542 459 382 310 6,0 4,8 3,7 2,8 2,0 11,7 9,1 6,8 4,9 3,0 18,5 14,6 10,9 7,9 5,5 1,31 1,15 0,99 0,85 0,70 2,68 2,32 1,97 1,63 1,25 3,20 2,80 2,38 1,98 1,61 1,09 0,94 0,80 0,67 0,55 2,12 1,82 1,52 1,25 0,94 2,49 2,16 1,81 1,50 1,20 225 198 170 146 120 461 399 339 280 215 550 482 409 341 277 4,8 3,8 2,9 2,2 1,6 9,3 7,3 5,4 3,9 2,4 14,9 11,8 8,8 6,4 4,4 0,97 0,84 0,70 0,60 0,50 1,92 1,68 1,43 1,19 0,92 2,32 2,04 1,74 1,45 1,19 0,97 0,84 0,69 0,57 0,47 1,83 1,57 1,31 1,07 0,81 2,15 1,86 1,56 1,29 1,03 167 144 120 103 86 330 289 246 205 158 399 351 299 249 205 2,8 2,1 1,6 1,2 0,9 5,1 4,1 3,1 2,2 1,4 8,4 6,7 5,0 3,7 2,6 0,81 0,70 0,60 0,50 0,41 1,59 1,36 1,15 0,94 0,71 1,87 1,62 1,37 1,12 0,90 0,81 0,70 0,60 0,50 0,41 1,59 1,36 1,15 0,94 0,71 1,87 1,62 1,37 1,12 0,90 139 120 103 86 71 273 234 198 162 122 322 279 236 193 155 2,0 1,5 1,2 0,9 0,6 3,6 2,8 2,0 1,4 0,9 5,6 4,4 3,2 2,3 1,6 Entering air temperature: +25°C - Relative Humidity: 50% WT: 7/12 °C Model CCN-ECM 13 CCN-ECM 23 CCN-ECM 33 WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Vdc Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 1,31 1,15 0,99 0,84 0,70 2,67 2,32 1,96 1,63 1,24 3,19 2,79 2,37 1,97 1,60 1,09 0,94 0,80 0,67 0,55 2,13 1,82 1,53 1,25 0,95 2,50 2,16 1,82 1,50 1,21 225 198 170 144 120 459 399 337 280 213 549 480 408 339 275 4,8 3,8 2,9 2,2 1,6 9,4 7,3 5,4 3,9 2,4 14,9 11,8 8,8 6,4 4,4 1,12 0,99 0,85 0,73 0,60 2,32 2,01 1,71 1,42 1,09 2,78 2,43 2,07 1,72 1,40 1,01 0,88 0,74 0,62 0,51 1,98 1,70 1,42 1,17 0,88 2,33 2,02 1,69 1,39 1,12 193 170 146 126 103 399 346 294 244 187 478 418 356 296 241 3,6 2,9 2,2 1,7 1,2 7,2 5,7 4,2 3,1 1,9 11,6 9,2 6,9 5,0 3,5 0,89 0,77 0,65 0,55 0,45 1,74 1,49 1,26 1,03 0,77 2,05 1,77 1,50 1,23 0,96 0,89 0,77 0,65 0,55 0,45 1,74 1,49 1,26 1,03 0,77 2,05 1,77 1,50 1,23 0,95 153 132 112 95 77 299 256 217 177 132 353 304 258 212 165 2,4 1,9 1,4 1,0 0,7 4,3 3,3 2,4 1,7 1,0 6,7 5,2 3,9 2,7 1,8 0,73 0,63 0,54 0,46 0,37 1,44 1,24 1,04 0,85 0,64 1,70 1,47 1,24 1,02 0,82 0,73 0,63 0,54 0,46 0,37 1,44 1,24 1,04 0,85 0,64 1,70 1,47 1,24 1,02 0,82 126 108 93 79 64 248 213 179 146 110 292 253 213 175 141 1,7 1,3 1,0 0,7 0,5 3,1 2,3 1,7 1,2 0,7 4,7 3,7 2,7 1,9 1,3 Correction factors for different R.H. U.R. 48% 46% 28 WT: Pc Ps Pc Ps 7/12°C 0,95 1,00 0,90 1,00 8/13°C 0,94 1,00 0,88 1,00 10/15°C 1,00 1,00 1,00 1,00 12/17°C 1,00 1,00 1,00 1,00 Legend WT = Water temperature Vdc = Inverter power Qv = Air flow Dp(c) = Water side pressure drop Pc Qw Ps = Cooling Total emission = Water flow = Cooling Sensible emission CCN-ECM Version Carisma Coanda Emissions Cooling emission of 4 row coil Entering air temperature: +27°C - Relative Humidity: 50% WT: 7/12 °C Model CCN-ECM 14 CCN-ECM 24 CCN-ECM 34 WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Vdc Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 1,95 1,70 1,44 1,20 0,98 3,76 3,22 2,69 2,21 1,66 4,32 3,75 3,15 2,60 2,09 1,37 1,18 0,99 0,82 0,66 2,60 2,21 1,83 1,49 1,12 2,98 2,57 2,15 1,76 1,41 335 292 248 206 169 647 554 463 380 286 743 645 542 447 359 15,9 12,4 9,2 6,8 4,7 23,6 18,0 13,2 9,3 5,6 17,6 13,7 10,1 7,2 4,9 1,75 1,52 1,29 1,08 0,88 3,38 2,90 2,43 1,99 1,50 3,89 3,38 2,85 2,35 1,89 1,29 1,11 0,93 0,77 0,62 2,44 2,08 1,72 1,40 1,05 2,80 2,41 2,02 1,65 1,32 301 261 222 186 151 581 499 418 342 258 669 581 490 404 325 13,0 10,2 7,6 5,6 3,9 19,5 14,9 10,9 7,7 4,7 14,6 11,4 8,4 6,0 4,1 1,33 1,16 0,98 0,83 0,68 2,59 2,23 1,87 1,54 1,16 2,98 2,60 2,19 1,81 1,46 1,12 0,97 0,81 0,67 0,54 2,12 1,81 1,50 1,22 0,91 2,44 2,10 1,75 1,44 1,15 229 200 169 143 117 445 384 322 265 200 513 447 377 311 251 7,8 6,2 4,6 3,4 2,4 12,1 9,3 6,8 4,8 2,9 9,0 7,1 5,2 3,7 2,6 0,99 0,85 0,72 0,60 0,48 1,88 1,60 1,33 1,08 0,77 2,15 1,86 1,55 1,27 0,97 0,99 0,85 0,72 0,60 0,48 1,88 1,60 1,33 1,08 0,76 2,15 1,86 1,55 1,27 0,96 170 146 124 103 83 323 275 229 186 132 370 320 267 218 167 4,7 3,6 2,6 1,9 1,3 6,7 5,1 3,7 2,5 1,4 5,0 3,9 2,8 2,0 1,2 Entering air temperature: +26°C - Relative Humidity: 50% WT: 7/12 °C Model CCN-ECM 14 CCN-ECM 24 CCN-ECM 34 WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Vdc Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 1,74 1,51 1,28 1,08 0,87 3,36 2,88 2,41 1,98 1,49 3,87 3,36 2,82 2,33 1,87 1,29 1,11 0,93 0,78 0,63 2,45 2,08 1,73 1,41 1,05 2,81 2,42 2,02 1,66 1,33 299 260 220 186 150 578 495 415 341 256 666 578 485 401 322 13,0 10,1 7,6 5,5 3,8 19,4 14,9 10,8 7,6 4,6 14,5 11,3 8,3 5,9 4,1 1,54 1,34 1,14 0,95 0,78 2,99 2,57 2,15 1,76 1,33 3,43 2,99 2,52 2,08 1,67 1,21 1,04 0,87 0,73 0,58 2,29 1,95 1,62 1,32 0,98 2,63 2,26 1,89 1,55 1,24 265 230 196 163 134 514 442 370 303 229 590 514 433 358 287 10,3 8,1 6,1 4,5 3,1 15,7 12,0 8,8 6,2 3,8 11,7 9,1 6,8 4,8 3,3 1,11 0,97 0,83 0,70 0,57 2,19 1,89 1,58 1,31 0,99 2,52 2,19 1,85 1,54 1,24 1,04 0,89 0,75 0,62 0,50 1,97 1,68 1,39 1,13 0,84 2,26 1,95 1,62 1,33 1,06 191 167 143 120 98 377 325 272 225 170 433 377 318 265 213 5,7 4,5 3,4 2,5 1,8 8,9 6,9 5,1 3,6 2,2 6,7 5,2 3,9 2,8 1,9 0,91 0,78 0,66 0,55 0,44 1,72 1,46 1,22 0,99 0,74 1,97 1,71 1,42 1,16 0,93 0,91 0,78 0,66 0,55 0,44 1,72 1,46 1,22 0,99 0,74 1,97 1,71 1,42 1,16 0,93 157 134 114 95 76 296 251 210 170 127 339 294 244 200 160 4,0 3,1 2,2 1,6 1,1 5,8 4,3 3,1 2,2 1,3 4,3 3,3 2,4 1,7 1,1 Entering air temperature: +25°C - Relative Humidity: 50% WT: 7/12 °C Model CCN-ECM 14 CCN-ECM 24 CCN-ECM 34 WT: 8/13 °C WT: 10/15 °C WT: 12/17 °C Vdc Qv m3/h Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa Pc kW Ps kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 1,54 1,34 1,13 0,95 0,77 2,98 2,56 2,14 1,76 1,32 3,42 2,97 2,50 2,07 1,66 1,21 1,04 0,88 0,73 0,59 2,30 1,95 1,62 1,32 0,99 2,63 2,27 1,90 1,55 1,24 265 230 194 163 132 513 440 368 303 227 588 511 430 356 286 10,4 8,1 6,1 4,5 3,1 15,7 12,0 8,8 6,2 3,8 11,7 9,1 6,8 4,8 3,3 1,33 1,16 0,99 0,83 0,68 2,60 2,23 1,87 1,54 1,16 2,99 2,60 2,19 1,81 1,46 1,13 0,97 0,81 0,68 0,54 2,14 1,82 1,51 1,23 0,92 2,45 2,11 1,77 1,45 1,16 229 200 170 143 117 447 384 322 265 200 514 447 377 311 251 8,0 6,3 4,7 3,5 2,4 12,3 9,4 6,9 4,9 3,0 9,2 7,2 5,3 3,8 2,6 1,00 0,86 0,72 0,60 0,46 1,88 1,60 1,28 1,06 0,81 2,16 1,87 1,50 1,25 1,02 1,00 0,86 0,72 0,60 0,46 1,88 1,60 1,27 1,04 0,77 2,16 1,87 1,49 1,22 0,98 172 148 124 103 79 323 275 220 182 139 372 322 258 215 175 4,7 3,6 2,7 1,9 1,2 6,9 5,2 3,5 2,5 1,6 5,1 4,0 2,7 1,9 1,4 0,82 0,71 0,60 0,50 0,40 1,56 1,33 1,11 0,90 0,67 1,79 1,55 1,29 1,06 0,84 0,82 0,71 0,60 0,50 0,40 1,56 1,33 1,11 0,90 0,67 1,79 1,55 1,29 1,06 0,84 141 122 103 86 69 268 229 191 155 115 308 267 222 182 144 3,4 2,6 1,9 1,4 0,9 4,9 3,7 2,7 1,8 1,1 3,6 2,8 2,0 1,4 1,0 Correction factors for different R.H. U.R. 48% 46% WT: Pc Ps Pc Ps 7/12°C 0,95 1,00 0,90 1,00 8/13°C 0,94 1,00 0,88 1,00 10/15°C 1,00 1,00 1,00 1,00 12/17°C 1,00 1,00 1,00 1,00 Legend WT = Water temperature Vdc = Inverter power Qv = Air flow Dp(c) = Water side pressure drop Pc Qw Ps = Cooling Total emission = Water flow = Cooling Sensible emission 29 Carisma Coanda Emissions CCN-ECM Version Heating emission of 3 row coil Entering air temperature: +20°C WT: 70/60°C Model CCN-ECM 13 CCN-ECM 23 CCN-ECM 33 WT: 60/50°C WT: 50/40° WT: 50/45° WT: 45/40° Vdc Qv m3/h Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 3,44 2,98 2,54 2,12 1,72 6,49 5,60 4,67 3,82 2,88 7,61 6,59 5,53 4,54 3,65 296 256 218 182 148 558 482 402 329 248 654 567 476 390 314 6,0 4,7 3,5 2,6 1,8 10,2 7,9 5,8 4,0 2,4 15,8 12,3 9,0 6,4 4,3 2,63 2,28 1,94 1,62 1,32 4,98 4,30 3,59 2,94 2,22 5,85 5,07 4,25 3,50 2,82 226 196 167 139 114 428 370 309 253 191 503 436 366 301 243 3,9 3,0 2,3 1,7 1,1 6,6 5,1 3,7 2,6 1,6 10,3 8,0 5,9 4,2 2,8 1,82 1,58 1,35 1,13 0,92 3,47 3,00 2,51 2,06 1,55 4,09 3,55 2,98 2,45 1,98 313 272 232 194 158 597 516 432 354 267 703 611 513 421 341 2,1 1,6 1,2 0,9 0,6 3,6 2,8 2,1 1,4 0,9 5,6 4,4 3,2 2,3 1,6 2,10 1,82 1,55 1,30 1,05 3,96 3,42 2,85 2,34 1,76 4,65 4,03 3,38 2,78 2,23 361 313 267 224 181 681 588 490 402 303 800 693 581 478 384 9,1 7,0 5,3 3,9 2,7 15,4 11,9 8,6 6,1 3,7 23,8 18,5 13,5 9,6 6,5 1,70 1,47 1,26 1,05 0,85 3,21 2,78 2,32 1,90 1,43 3,77 3,27 2,74 2,26 1,82 292 253 217 181 146 552 478 399 327 246 648 562 471 389 313 6,4 4,9 3,7 2,7 1,9 10,9 8,4 6,1 4,3 2,6 16,8 13,0 9,6 6,8 4,6 Heating emission of 4 row coil Entering air temperature: +20°C WT: 70/60°C Model CCN-ECM 14 CCN-ECM 24 CCN-ECM 34 WT: 50/40° WT: 50/45° WT: 45/40° Vdc Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 3,69 3,19 2,68 2,22 1,78 7,27 6,17 5,08 4,11 3,04 8,00 6,89 5,74 4,70 3,75 317 274 230 191 153 625 531 437 353 261 688 593 494 404 323 11,1 8,6 6,3 4,5 3,1 17,3 13,0 9,2 6,3 3,7 12,0 9,2 6,7 4,7 3,2 2,83 2,45 2,06 1,71 1,37 5,60 4,76 3,93 3,17 2,35 6,16 5,30 4,43 3,62 2,90 243 211 177 147 118 482 409 338 273 202 530 456 381 311 249 7,2 5,6 4,1 3,0 2,0 11,3 8,5 6,0 4,2 2,5 7,8 6,0 4,4 3,1 2,1 1,97 1,71 1,44 1,19 0,96 3,93 3,35 2,76 2,24 1,66 4,31 3,72 3,11 2,55 2,04 339 294 248 205 165 676 576 475 385 286 741 640 535 439 351 3,9 3,1 2,3 1,6 1,1 6,3 4,7 3,4 2,3 1,4 4,3 3,3 2,4 1,7 1,2 2,25 1,95 1,64 1,36 1,09 4,44 3,77 3,11 2,51 1,86 4,89 4,21 3,51 2,87 2,30 387 335 282 234 187 764 648 535 432 320 841 724 604 494 396 16,7 13,0 9,5 6,8 4,7 26,1 19,6 13,9 9,6 5,6 18,0 13,8 10,0 7,1 4,8 1,83 1,58 1,33 1,10 0,89 3,62 3,07 2,53 2,05 1,52 3,97 3,42 2,85 2,34 1,87 315 272 229 189 153 623 528 435 353 261 683 588 490 402 322 11,8 9,2 6,7 4,8 3,3 18,5 13,9 9,9 6,8 4,0 12,7 9,8 7,1 5,0 3,4 Ph Qw Dp(c) = Emission = Water flow = Water side pressure drop Legend WT = Water temperature Vdc = Inverter power Qv = Air flow 30 WT: 60/50°C Qv m3/h CCN-ECM Version Carisma Coanda Emissions Heating emission of 1 row additional coil Entering air temperature: +20°C WT: 80/70°C Model CCN-ECM 13+1 14+1 CCN-ECM 23+1 24+1 CCN-ECM 33+1 34+1 WT: 75/65° WT: 70/60° WT: 65/55° WT: 60/50° WT: 55/45° Vdc Qv m3/h Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 1,90 1,69 1,48 1,28 1,09 3,77 3,33 2,88 2,46 1,97 4,53 4,04 3,51 3,01 2,53 163 145 127 110 94 324 286 248 212 169 390 347 302 259 218 5,5 4,5 3,5 2,8 2,1 4,5 3,6 2,8 2,1 1,4 7,3 6,0 4,7 3,6 2,6 1,71 1,52 1,33 1,16 0,98 3,39 2,99 2,59 2,22 1,77 4,08 3,64 3,17 2,71 2,28 147 131 114 100 84 292 257 223 191 152 351 313 273 233 196 4,7 3,8 3,0 2,3 1,7 3,8 3,1 2,4 1,8 1,2 6,2 5,1 4,0 3,0 2,2 1,52 1,35 1,18 1,03 0,87 3,01 2,66 2,31 1,97 1,58 3,64 3,24 2,82 2,42 2,04 131 116 101 89 75 259 229 199 169 136 313 279 243 208 175 3,8 3,1 2,5 1,9 1,4 3,1 2,5 2,0 1,5 1,0 5,1 4,2 3,3 2,5 1,8 1,33 1,18 1,04 0,90 0,76 2,64 2,33 2,02 1,73 1,38 3,19 2,85 2,48 2,12 1,79 114 101 89 77 65 227 200 174 149 119 274 245 213 182 154 3,1 2,5 2,0 1,5 1,2 2,5 2,0 1,6 1,2 0,8 4,1 3,4 2,7 2,0 1,5 1,14 1,02 0,89 0,77 0,66 2,26 2,00 1,74 1,49 1,19 2,75 2,45 2,14 1,83 1,54 98 88 77 66 57 194 172 150 128 102 237 211 184 157 132 2,4 1,9 1,5 1,2 0,9 2,0 1,6 1,2 0,9 0,6 3,2 2,6 2,1 1,6 1,2 0,95 0,85 0,74 0,64 0,55 1,89 1,67 1,45 1,24 1,00 2,31 2,06 1,79 1,54 1,30 82 73 64 55 47 163 144 125 107 86 199 177 154 132 112 1,8 1,4 1,1 0,9 0,7 1,4 1,2 0,9 0,7 0,5 2,4 2,0 1,5 1,2 0,9 Heating emission of 2 row additional coil Entering air temperature: +20°C WT: 65/55°C Model CCN-ECM 13+2 CCN-ECM 23+2 CCN-ECM 33+2 WT: 60/50° WT: 55/45° WT: 50/40° WT: 45/40° WT: 45/35° Vdc Qv m3/h Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa Ph kW Qw l/h Dp(c) kPa 10 7,5 5 3 1 10 7,5 5 3 1 10 7,5 5 3 1 295 250 205 165 130 540 450 370 295 215 620 525 430 345 275 2,32 2,04 1,77 1,51 1,26 4,56 3,98 3,42 2,86 2,21 5,42 4,77 4,12 3,45 2,82 200 175 152 130 108 392 342 294 246 190 466 410 354 297 243 14,8 11,9 9,2 6,9 5,1 12,3 9,6 7,4 5,4 3,4 19,8 15,8 12,2 8,9 6,3 2,00 1,77 1,53 1,30 1,09 3,94 3,44 2,97 2,48 1,91 4,70 4,14 3,58 3,00 2,45 172 152 132 112 94 339 296 255 213 164 404 356 308 258 211 11,6 9,3 7,2 5,5 4,0 9,7 7,6 5,8 4,3 2,7 15,6 12,5 9,7 7,1 5,0 1,69 1,49 1,29 1,10 0,92 3,33 2,91 2,51 2,10 1,62 3,98 3,51 3,03 2,54 2,08 145 128 111 95 79 286 250 216 181 139 342 302 261 218 179 8,8 7,0 5,4 4,1 3,0 7,3 5,7 4,4 3,2 2,1 11,8 9,5 7,3 5,4 3,8 1,37 1,21 1,05 0,90 0,75 2,72 2,38 2,05 1,72 1,33 3,26 2,87 2,49 2,08 1,71 118 104 90 77 65 234 205 176 148 114 280 247 214 179 147 6,2 5,0 3,9 2,9 2,2 5,2 4,1 3,2 2,3 1,5 8,5 6,8 5,3 3,9 2,7 1,30 1,14 0,99 0,84 0,71 2,55 2,23 1,92 1,60 1,24 3,04 2,67 2,31 1,93 1,58 224 196 170 144 122 439 384 330 275 213 523 459 397 332 272 19,2 15,4 11,9 9,0 6,6 15,9 12,5 9,6 7,0 4,4 25,6 20,5 15,8 11,6 8,1 1,06 0,94 0,81 0,69 0,58 2,11 1,84 1,59 1,33 1,03 2,54 2,24 1,94 1,63 1,33 91 81 70 59 50 181 158 137 114 89 218 193 167 140 114 4,0 3,2 2,5 1,9 1,4 3,4 2,7 2,1 1,5 1,0 5,6 4,5 3,5 2,5 1,8 Legend WT = Water temperature Vdc = Inverter power Qv = Air flow Ph Qw Dp(c) = Emission = Water flow = Water side pressure drop 31 Water side pressure drop 3 row coil 4 row coil Dp Dp 50 50 40 40 3 30 CCN-ECM Version Carisma Coanda 30 20 2 20 3 2 10 9 8 10 9 8 7 7 6 6 5 5 1 4 4 3 3 2 2 1 100 200 1 300 400 600 800 1000 1500 1 Qw Pressure drop for mean water temperature of 10°C; for different temperatures multiply the pressure drop figure by the K correction factors in the table. 100 °C K 200 20 0,94 30 0,90 1 row additional coil 40 0,86 600 50 0,82 800 1000 1500 60 0,78 Qw 70 0,74 80 0,70 Dp 60 60 50 50 40 40 30 30 20 20 10 9 8 7 6 10 9 8 7 6 3 5 5 4 4 3 2 1 3 1 2 2 2 1 50 60 80 100 200 300 400 600 800 1000 Legend Qw = water flow (l/h) Dp = pressure drop (kPa) 1 Qw Pressure drop for mean water temperature of 65°C; for different temperatures multiply the pressure drop figure by the K correction factors in the table. 32 400 2 row additional coil Dp 3 300 50 60 °C K 80 100 40 1,14 200 50 1,08 300 400 60 1,02 600 800 1000 70 0,96 Qw 80 0,90 CCN-ECM Version Carisma Coanda Accessories VBP Main coil 3 way valve VBA Additional coil 3 way valve Control valve kit:3 way valve, ON-OFF, with electric motor and mounting kit with micrometric lockshield valve. Control valve kit:3 way valve, ON-OFF, with electric motor and mounting kit with micrometric lockshield valve. VS Simplified kit for 3 way valve for main and additional coil V2 2 way valve for main and additional coil 3 way valve, (ON-OFF) with electric motor and mounting kit. Valve with flat connection without micrometric lockshield valve. Control valve kit: 2 way valve, ON-OFF, with electric motor and mounting kit. Valve type mod. Main 1-2 DN (Ø) Kvs Micrometric lockshield valve DN (Ø) Kvs 15 1/2" 1,6 15 Valve 1/2" 2 Code Fitted Not Fitted 9066561H 9066560H VBP VBA Valves pressure drop Kvs 2 Dp 3 20 3/4" 2,5 15 1/2" 2 9060471H 9060474H Additional All 15 1/2" 1,6 15 1/2" 2 9060472H 9060475H 1-2 15 1/2" 1,6 - - - 9066571H 9066570H 3 20 3/4" 2,5 - - - 9060484H 9060481H 4 All 15 1/2” 1,6 - - - 9060483H 9060480H 2 1-2 15 1/2" 1,7 - - - 9060476H 9060478H 1 3 20 3/4" 2,8 - - - 9060477H 9060479H All 15 1/2” 1,7 - - - 9060476H 9060478H Main Additional Kvs 1,6 Kvs 2,5 Kvs 2,8 40 Main VS Kvs 1,7 30 20 10 9 8 7 6 5 3 100 200 300 400 600 800 1000 2000 3000 4000 Main V2 Additional Qw Legend Qw = water flow (l/h) Dp = pressure drop (kPa) 33 Carisma Coanda Accessories CCN-ECM Version BSO Extension condensate collection tray to cover valve assembly Connection side ID Code left BSO BSO-SX 6060402 right BSO-DX 6060403 SCR plastic condensate drain pipe with fast connection It helps regular drainage of condensate thereby preventing the formation of bends. ID Code SCR 6060420 PCC condensate drain pump ID Fitted PCC-M Not fitted PCC-S Code 9064011 9064010 Height for vertical flow (m) 1 2 3 4 Water flow (l/h) depending on the length of horizontal flow 5m 10 m 6,8 6,3 5,5 5,0 4,2 3,8 3,0 2,6 FRC fresh air connection Code FRC 100 ID 6064191 Code TCX 3.9 x 9.5 6064192 TCX 3.9 x 9.5 98 34 FRC 120 122 ID CCN–ECM configuration Carisma Coanda CCN-ECM Version For this fan coil configuration, the 1-10 Vdc signal, which controls the inverter, must be supplied by a controller with the following signal specifications: • Impedance < 100 Ω; • Maximum speed 10 Vdc; • Fan OFF with V < 0,9 Vdc. • Signal 0,3 / 13 V. CCN–ECM electric wiring diagram CM CP Legend CONTROLLER ECM BLAC BOARD M CM CP = Controller = Inverter circuit board = Electronic motor = Motor fan connection = Motor fan thermal protection connection 35 Carisma Coanda CR-T-ECM Wall electronic control ID Code CR-T-ECM 9066342 CCN-ECM Version The control must always be connected with UPM-ECM power unit (fitted on the unit) or with UPS-ECM power unit (not fitted on the unit). • • • • • • • • • It allows to control up to 16 units (one power unit for each unit). ON-OFF switch. Manual 3 speed switch or automatic continuous speed control. Manual Summer/Winter switch. Continuous speed control based on the difference between ambient temperature and Set temperature (speed switch in Auto position). Electronic room thermostat for fan or valves control (ON-OFF). Simultaneus thermostatic control of the valves and fan. It allows to control the low temperature cut-out thermostat (NTC). It allows to control the summer/winter cycle with a centralized and remote switch or with an automatic change-over fitted on the water pipe (for 2-tube installations only). Dimensions: 133x93x37 mm Description Power unit for CR-T-ECM remote control (fitted on the unit) Power unit for CR-T-ECM remote control (not fitted on the unit) ID Code UPM-ECM UPS-ECM 9066341 9066340 Power unit to be installed on the fan coil (fan coil interface). It controls the fan and the valves of the fan coil. The power unit is connected to the electric supply. The power unit receives the information required from the control. Control power absorption: 1,5 VA 36 CR-T-ECM Accessories Carisma Coanda CCN-ECM Version NTC low temperature cut-out thermostat ID Code NTC 3021090 To be fitted between the coil fins; when connecting the control, the NTC probe cable must be separated from the power supply wires. To be used with the following controls: CR-T-ECM It stops the fan when the water temperature is lower than 28°C and it starts the fan when is higher than 33°C. Change-Over CH 15-25 ID Code CH 15 -25 9053049 Automatic summer/winter switch to be installed in contact with the water circuit. For 2-tube installations only (not to be used with 2 way valve). To be used with the following controls: CR-T-ECM. A B Legend A = red B = black 37 CCN / CCN-ECM Version Carisma Coanda Controls and units MB version All the Carisma Coanda units can be supplied with a wide range of controls, which allows managing one single unit or several units by using the Modbus RTU - RS 485 communication protocol. Units can be managed according to the Master/Slave logic (up to 20 units) or by supervisory components. The system consists in a MB board and a series of controls, such as the T-MB wall control, the RT03 infra-red remote control, the PSM-DI multifunction control and the Sabianet supervisory program. T-MB Wall control PSM-DI Multifunction PC Sabianet Screenshot RT03 Infra-red remote control Sabianet Software 38 control CCN / CCN-ECM Version Carisma Coanda Controls and units MB version MB electronic board Description Version CCN CCN CCN_ECM CCN_ECM MB electronic board fitted on the unit MB electronic board supplied with separate packaging MB electronic board fitted on the unit MB electronic board supplied with separate packaging ID Code MB-M MB-S MB-ECM-M MB-ECM-S 9066332 9066333 9066334 9066335 The MB electronic board, to be mounted on the fan coil internal unit, is set to carry out different functions and adjustment modes, in order to meet the installation requirements. These modes are selected by setting the configuration dip switches on the board. • 2/4 pipe system. • Fan ON/OFF thermostatic control. • Valve ON/OFF thermostatic control and continuous ventilation. • Valve and simultaneous ventilation ON/OFF thermostatic control. • Fan operation control depending on the coil temperature (cut-out T3 probe fitted), which can be activated only in heating mode or heating and cooling mode. • Automatic switch of the operating mode by means of T2 water probe (optional) applied on the 2 pipe system. • Seasonal switch by means of remote contact. • ON/OFF of the fan coil by means of the remote contact (window or clock contact). • Electric heater control By activating the cut-out T3 probe function, the fan is stopped in winter when the coil temperature is lower than 32°C and started when the temperature reaches 36°C. In summer mode, the fan stops when the temperature inside the coil exceeds 22°C and starts when it drops below 18°C. The following connections are located on the power board: • Receiver for infra-red remote control. • T-MB wall control. • RS 485 serial connection to manage several fan coils in Master/Slave configuration or to create a supervisory network. 39 CCN / CCN-ECM Version Controls and units MB version Carisma Coanda T-MB wall control Description Wall control (to be used with MB board only) ID Code T-MB 9066331E Wall control with display that allows controlling one or more units in Master/Slave mode. The control is equipped with internal sensor to detect the room temperature, which can be defined as a priority compared to the return air sensor on the fan coil. The T-MB control features the following functions: • • • • • • • • 40 Switch the appliance ON and OFF. Temperature set. Modify the set point (when used as a +/- 3° variation of the set point configured from Sabianet supervisory program). Set the fan speed (low, medium, high or autofan). Set the operation mode (fan only, cooling, heating; auto for 4 pipe systems with mode selection depending on the air temperature). Time setting. Weekly ON/OFF program. Display and change of the fan coil operation parameters. CCN / CCN-ECM Version Controls and units MB version Carisma Coanda RT03 infra-red remote control Description RT03 infra-red remote control with receiver supplied with separate packaging (to be used with MB board only) RT03 infra-red remote control supplied with separate packaging (to be used with MB board only) Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with MB board only) ID Code RS-RT03 9066337 RT03 3021203 RS 9066338 The infra-red remote control allows setting by a remote position the fan coil operation parameters. The RT03 infra-red remote control features the following functions: • Switch the appliance ON and OFF. • Temperature set. • Set the fan speed (low, medium, high or autofan). • Set the operation mode (fan only, cooling, heating; auto for 4 pipe systems with mode selection depending on the air temperature). • Time setting. • 24 hours ON/OFF program. Installation example with infra-red remote ID Code RT03 3021203 control ID Code ID Code RS-RT03 9066337 RS 9066338 41 CCN / CCN-ECM Version Carisma Coanda Controls and units MB version A group of Carisma Coanda units with MB electronic board can be connected via a serial link and can consequently be managed at the same time by just one T-MB wall control or RT03 infra-red remote control. Using the special jumper present on the MB board, one unit must be configured as the master, and all the others as slaves. It is clear that the remote control must be pointed at the receiver on the master unit. To avoid problems, it is recommended to install and connect the receiver only on the master unit. With T-MB wall control One control for each unit (Maximum length of the connection cable = 20 m) Max 20 m One control for more units (20 units max.) (Maximum total length of the connection cable = 800 m) Max 20 m With RT03 infra-red remote control One control for each unit One control for more units (20 units max.) (Maximum total length of the connection cable = 800 m) T2 accessory for units with MB electronic board ID Code T2 9025310 The T2 sensor can be combined with MB boards to be placed on the water supply pipe upstream 3 way valves (not to be used with 2 way valve). The T2 sensor must be used as described below: • Change-Over for 2-pipe system for the automatic switch of the operating mode. If water temperature is lower than 20°C, cooling mode is set; on the other hand, if water temperature exceeds 30°C, heating mode is set. • It can be used on units with electric heater and hot water supply. The T2 priority probe activates the electric heater or water valve, depending on the water temperature detected. If water temperature exceeds 34°C, the water valve ON-OFF control is activated; on the other hand, if water temperature is lower than 30°C, the electric heater is activated. 42 CCN / CCN-ECM Version Controls and units MB version Carisma Coanda PSM-DI Multifunction control Description Multifunction control (to be used with MB board only) ID Code PSM-DI 3021293 Another option available for the serial communication between the units is the possibility to connect up to 60 Carisma Coanda units in series and manage them with just one wall mounted PSM-DI controller. The wall mounted controller can be used to set the operating mode for each individual unit connected, display the operating conditions of each individual unit, and set the ON/OFF time sets for each day of the week (the program can be set for all the units and for a maximum of two groups of units). If more than 60 units need to be connected, two or more controllers must be used. Each wall mounted controller only manages the units it is connected to. The PSM-DI control is used to manage a series of fan coils, up to a maximum of 60 units (the maximum length of the RS 485 connection cable must not exceed 800 m), from one single control point. The PSM-DI control communicates via a serial line with all the units connected, with the possibility of controlling them all together or individually. In fact, the unique address of each individual fan coil means that all the units can be called at the same time, or the individual unit called, to perform the following functions: - display the current operating mode, the fan speed, the set point; - display the room temperature measured on the individual unit; - turn all the units ON and OFF at the same time or alternatively each unit individually; - change the operating mode (fan only, heating, cooling, automatic changeover); - change the set point; - modify the values and operation parameters of the fan speed. Each function can then be sent to all the units connected, or alternatively to each individual unit. Different set points or operating modes can be set for each individual unit. The PSM-DI panel can also be used for the time management of the units over the week. Four ON times and four OFF times can be set on the units for each day of the week. A different Temperature set that will be considered as Operation set for all connected appliances, can be set for each event. If the Temperature set is not entered for the individual event, it must be set during programming for each individual unit or for the entire network. Units without receiver or with receiver can be connected within the network: the former can receive instructions only from the PSM-DI wall mounted panel; while the latter can receive information from both the wall mounted panel (PSM-DI) and infra-red remote control. Use the infra-red remote control to force ON mode of the individual unit, if ON/OFF daily time programming has been set. The unit will regain the settings from the PSM-DI panel during execution of successive start-up program. The PSM-DI panel cannot be used together with the Sabianet management program (see next page). Note: set the configuration Dip Switches of each fan coil as illustrated in the remote control use manual, based on the required solutions. Note: the RS 485 network’s overall length must not exceed 700/800 metres. 43 Management system for a network of units CCN / CCN-ECM Version Carisma Coanda Sabianet program for managing a network of Sabiana MB fan coils Description Hardware/software supervisory system (to be used with MB board only) ID Code Sabianet 9079118 Sabianet is a centralised control system for networks of Sabiana MB fan coils, based on software that runs on LINUX™. The Sabianet software offers a practical and economical solution for managing the units, with the simple click of the mouse. The main characteristics include simplicity of use, an extremely complete and functional weekly program, and the possibility to access the historical operating data for each individual appliance connected. The program exploits all the potential of our units with remote controls, representing an addition to the latter. The Sabianet program is a control tool that can be used as a replacement for the remote control, or in parallel, however the settings made using Sabianet can have priority over those made using the remote control. The program can be used to: • Create uniform groups (groups of units on individual floors, in offices or rooms). • Save weekly programs configured for different types of operation (summer, winter, mid seasons, closing periods etc.); these can then be recalled and activated with a simple click of the mouse. Weekly on/off cycles can be set for individual units or groups of units. • Set the operating conditions for each individual unit or groups of units (operating mode, fan speed, temperature setting). • Set the set point limits for each individual unit or groups of units. • Switch each individual unit or groups of units ON or OFF. “MONITORING” Screen The main program screen can display and interact with the entire network of units. An individual unit, a group of units or the entire network can be called so as to make modifications to the operating mode and the set point. The user can then check the operating status of each individual unit, read the room temperature, the coil temperature and the operating status of the condensate drain pump or any alarms. 44 Management system for a network of units CCN / CCN-ECM Version Carisma Coanda Displaying a unit The “MONITORING” screen shows the units that are connected to the network and scanned by the program. The icon of the terminal unit provides the following information: - Unit name ( C01000001 ) - Set temperature ( TSET ) - Room temperature ( TA ) - Unit status: ON or OFF -Mode: • Summer • Auto • Winter • Fan only - Fan speed: • Low • High • Medium • Autofan “EVENT MANAGEMENT” screen The “Weekly Program” can be used to set the unit operating parameters for each day of the week. Up to 20 different weekly programs can be set. Time bands are available for each day of the week. The time and the type of operation to be performed by the unit can be set for each band. The time and the operating parameters can then be displayed before being sent to the unit and implemented. 45 Management system for a network of units CCN / CCN-ECM Version Carisma Coanda PC Sabianet Software Connection of a Carisma Coanda network with MB electronic board 60 units max. Carisma Coanda Unit Carisma Coanda Unit Carisma Coanda Unit MC2 jumper to close network end. (*) In the event of more than 60 units, add one or more Router-S (see below). RS 485 serial connection cable Shielded cable to be used: Belden 9841, RS-485, 1x2x24 AWG SFTP, 120 Ohm PSM-DI and Sabianet electronic boards for Coanda units ID Code SIOS 3021092 SIOS is a board equipped with 8 relays with potential free contact to control the activation or deactivation of remote electric utilities. Moreover, the board has 8 digital inlets to display the actuators or external consents, such as motor or other. The SIOS boards can be connected: - inside a network managed by Sabianet; - to a PSM-DI panel (one SIOS for each PSM-DI panel). ID Code Router-S 3021290 The Router-S is an electronic board that: -allows creating networks with more than 60 units (minimum 2 Router-S are required) or to divide the network (per floor, building, etc.); -allows creating a Master/Slave sub-network to be controlled as an indipendent group. The Router-S can be used only inside a network managed by Sabianet. The number of Router-S to be used is:-up to 60 units: no Router-S - from 61 to 120 units: 2 Router-S - every 60 subsequent units: 1 additional Router-S 46 The descriptions and illustrations provided in this publication are not binding: Sabiana reserves the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements. Air Conditioning ENVIRONMENTAL COMFORT Sabiana s.p.a. • via Piave, 53 • 20011 Corbetta • Milano • Italia • tel. +39.02.97203.1 r.a. / +39.02.97270429 / +39.02.97270576 fax +39.02.9777282 / +39.02.9772820 • www.sabiana.it • [email protected] D/02/13 COD. A4640100 CARISMA COANDA - 02/13 One Way Cassette Fan Coils Carisma Coanda CCN Carisma Coanda CCN-ECM
© Copyright 2024 ExpyDoc