Fixed Gas Detector CTX 300 FIXED GAS DETECTOR Quick response time Pre-calibrated sensor modules One man calibration Local display (optional) Durable in harsh environments The detection of toxic gases or oxygen depletion requires the installation of detectors satisfying demanding requirements. The CTX 300 range is designed for all safety needs in unclassified areas. Flexibility and reduced maintenance The CTX 300 transmits the relevant data in record time, covering all hazard situations and providing extreme flexibility by way of a wide range of sensors. Sensors integrating zero and sensitivity parameters are used so that maintenance is quick and safe. Equipped with pre-calibrated sensors, display unit and adjustment devices, the CTX 300 transmitter can be maintained by one person. Satisfying your safety requirements means making genuine technical breakthroughs as well as providing clear economic value. The principle of the pre-calibrated sensor unit allows maintenance by a single person and significant reduction in costs. Compliance with standards • Compliance with European standards • EMC in compliance with directives CERTIFICATIONS Pre-calibrated sensor for easier maintenance The Fixed Gas Detection Experts www.oldhamgas.com an company SENSORS TECHNICAL SPECIFICATIONS Operating temperature 30.0 % -20 °C to +50 °C WC3oO2F O2 Electrochemical 100 % +5 °C to +40 °C WC3oO2S 100 -20 °C to +50 °C WC3oCOA 300 -20 °C to +50 °C WC3oCOB CO Electrochemical 1000 -20 °C to +50 °C WC3oCOC 1.00 % -20 °C to +50 °C WC3oCOD 10.0 % -20 °C to +50 °C WC3oCOE 6514881 1% -30 °C to +45 °C WC30IRL 5% -30 °C to +45 °C CO2 Infrared 6514882 10 % -30 °C to +45 °C 6514879 50 % -30 °C to +45 °C 30.0 -20 °C to +50 °C WC3oHSA H 2S Electrochemical 100 -20 °C to +50 °C WC3oHSB 1000 -20 °C to +50 °C WC3oHSC 100 -20 °C to +50 °C WC3oNOA NO Electrochemical 300 -20 °C to +50 °C WC3oNOB 1000 -20 °C to +50 °C WC3oNOC 10.0 -20 °C to +50 °C WC3oN2A NO2 Electrochemical 30.0 -20 °C to +50 °C WC3oN2B 10.0 -20 °C to +50 °C WC3oSOA SO2 Electrochemical 30.0 -20 °C to +50 °C WC3oSOB 100 -20 °C to +50 °C WC3oSOC Cl2 Electrochemical 10.0 -20 °C to +50 °C WC3oCL2 2000 -20 °C to +50 °C WC3oH2A H2 Electrochemical 2% -20 °C to +50 °C WC3oH2B 30.0 -20 °C to +50 °C WC3oHLA HCl Electrochemical 100 -20 °C to +50 °C WC3oHLB 10.0 -20 °C to +50 °C HCN WC3oHNA Electrochemical 30.0 -20 °C to +50 °C WC3oHNB 100 -20 °C to +40 °C WC3oNH3 WC30NH3F 100 -40 °C to +40 °C NH3 Electrochemical 1000 -20 °C to +40 °C WC3oNH1 WC30NH2 5000 -20 °C to +40 °C ETO/PO Electrochemical 30.0 -20 °C to +50 °C WC3oOET HF Electrochemical 10.0 -10 °C to +30 °C WC3oHFA O3 Electrochemical 1.00 -20 °C to +50 °C WC3oO3A PH3 Electrochemical 1.00 -20 °C to +50 °C WC3oPH3 ClO2 Electrochemical 3.00 -20 °C to +50 °C WC3oCLO COCl2 Electrochemical 3.00 -20 °C to +40 °C WC3oCCL Methylene chloride CTX300-507 Semiconductor 500 -20 °C to +55 °C Methyl chloride CTX300-508 Semiconductor 500 -20 °C to +60 °C CTX300-652 2000 -20 °C to +50 °C Toluene Semiconductor CTX300-657 500 -20 °C to +50 °C Trichlorethylene CTX300-655 Semiconductor 500 -20 °C to +60 °C CTX300-653 2000 -20 °C to +50 °C Xylene Semiconductor CTX300-660 500 -20 °C to +50 °C Ethanol CTX300-654 5000 -20 °C to +60 °C Semiconductor CTX300-656 500 -20 °C à +50 °C R12 CTX300-500 Semiconductor 10000 -20 °C to +55 °C R22 CTX300-501 Semiconductor 2000 -20 °C to +55 °C R123 CTX300-509 Semiconductor 2000 -20 °C to +55 °C R134a CTX300-502 Semiconductor 2000 -20 °C to +55 °C R11 CTX300-505 Semiconductor 10000 -20 °C to +55 °C R23 CTX300-506 Semiconductor 10000 -20 °C to +55 °C R143a CTX300-511 Semiconductor 2000 -20 °C to +55 °C R404a CTX300-512 Semiconductor 2000 -20 °C to +55 °C R507 CTX300-513 Semiconductor 2000 -20 °C to +55 °C R410a CTX300-514 Semiconductor 1000 -20 °C to +55 °C R32 CTX300-515 Semiconductor 1000 -20 °C to +55 °C If you have any questions about other gases or ranges, please consult us at [email protected] Gas Part Number Type of sensor Range (ppm) Relative humidity uncondensed 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 5 % to 95 % RH 5 % to 95 % RH 5 % to 95 % RH 5 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % à 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH 10 % to 95 % RH Ordering example for CTX 300: WC3oO2F: - without display Order WC3ØO2F - with display Order WC3AO2F SENSORS TECHNICAL SPECIFICATIONS Accuracy (% at PA full scale) +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 2 % +/- 2 % +/- 2 % +/- 2 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 1.5 % +/- 2 % +/- 2 % +/- 3 % +/- 3 % +/- 3 % +/- 3 % +/- 3 % +/- 3 % +/- 3 % +/- 3 % +/- 2 % +/- 1.5 % +/- 15 % relative to alarm threshold Life span (in months) 28 36 48 48 48 48 48 60 60 60 60 36 36 36 36 36 36 24 24 36 36 36 24 24 24 18 18 24 24 24 24 24 24 36 12 18 12 24 18 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 Pressure : Atm +/- 10 %, IP 55, NEMA 3 and 3R T(50) (seconds) 10 < 20 15 15 15 < 20 < 20 70 (T90) 70 (T90) 70 (T90) 70 (T90) 15 15 15 15 15 15 20 20 15 15 15 50 50 50 50 50 30 30 50 50 50 50 50 50 40 40 50 50 40 40 20 20 40 20 20 20 20 30 30 30 30 30 30 30 30 30 20 20 Pre-calibrated sensors ease maintenance ACCESSORIES Gas collector Calibration cup Remote calibration cup Mounting bracket Bypass adapter TECHNICAL SPECIFICATIONS Better performance, enhanced ergonomics Enclosure Polycarbonate housing Function Detector-transmitter Better performance Display Highly visible backlight display unit (optional, gas dependent) • Excellent sensitivity and signal stability • 2 mA signal for maintenance mode • Signal lower than 1 mA for failure mode Clear readability • Highly sensitive, lighted display allows local reading • Effective power-up indication by indicator lights • Indication of maintenance or fault function High-Level technology • Pre-calibrated sensor avoiding the need to use unstable gases on site for calibration purposes • Remote sensor unit allowing measurements in even the most inaccessible places • High-performance semiconductor type detector (detection of freon gas, etc.) Advanced design • Highly resistant to environmental elements • Avoids having to use protective covers Indicator lights Link In operation: green color (on CTX 300 : 3-wire) Failure / maintenance: yellow color 2 wires – CTX 300 without display unit 3 wires – CTX 300 with display unit Cable entry PG9 cable gland (outer diameter 6 to 11 mm) Power supply 15 to 32 V DC Power consumption CTX 300 without display unit: 27 mA CTX 300 with display unit: 110 mA Infrared or semiconductor versions: 100mA Operating temperature -20°C to + 50°C, 4°F to + 122°F Sealing IP 66, NEMA 3 & 3R Weight 520 g Dimensions 130 x 136 x 69 (l x h x d) in mm Heavy-duty Certification • Use of polycarbonate and stainless steel mounting hardware • Resistant to corrosive agents • Durable housing EMC Type 1 according to EN 50270:06 Impedance 32 ohms max loop for CTX 300 with display unit and for solid states and CO2 sensor versions Specifically adapted options • Removable filters, interchangeable without opening the housing (which is dust-proof, condensation-proof and water-resistant) • Splash guard • Gas collector cone • Mounting brackets • Pitot tubes, floats, heating protective device, etc. CCSA – Class 4812 10 – Signal Appliances-Detectors CSAUS – Class 4812 86 - Signal Appliances-Miscellaneous 128 ohms max loop for CTX 300 without display unit 69 mm 130 mm CTX300_Lit_Eng_10July2014 136 mm www.oldhamgas.com AMERICAS Tel.: +1-713-559-9280 Fax: +1-281-292-2860 [email protected] EUROPE Tel.: +33-3-21-60-80-80 Fax: +33-3-21-60-80-00 [email protected] ASIA PACIFIC Tel.: +86 21 3127 6373 Fax: +86 21 3127 6365 [email protected]
© Copyright 2025 ExpyDoc