CTX 300 - Oldham Gas

Fixed Gas Detector
CTX
300
FIXED GAS DETECTOR
 Quick response time
 Pre-calibrated
sensor modules
 One man calibration
 Local display (optional)
 Durable in harsh
environments
The detection of toxic gases or oxygen
depletion requires the installation of detectors
satisfying demanding requirements. The CTX
300 range is designed for all safety needs in
unclassified areas.
Flexibility and reduced
maintenance
The CTX 300 transmits the relevant data in
record time, covering all hazard situations and
providing extreme flexibility by way of a wide
range of sensors.
Sensors integrating zero and sensitivity
parameters are used so that maintenance is
quick and safe.
Equipped with pre-calibrated sensors, display
unit and adjustment devices, the CTX 300
transmitter can be maintained by one person.
Satisfying your safety requirements means
making genuine technical breakthroughs as
well as providing clear economic value.
The principle of the pre-calibrated sensor unit
allows maintenance by a single person and
significant reduction in costs.
Compliance with standards
• Compliance with European standards
• EMC in compliance with directives
CERTIFICATIONS
Pre-calibrated sensor for
easier maintenance
The Fixed Gas Detection Experts
www.oldhamgas.com
an
company
SENSORS TECHNICAL SPECIFICATIONS
Operating
temperature
30.0 %
-20 °C to +50 °C
WC3oO2F
O2
Electrochemical
100 %
+5 °C to +40 °C
WC3oO2S
100
-20 °C to +50 °C
WC3oCOA
300
-20 °C to +50 °C
WC3oCOB
CO
Electrochemical
1000
-20 °C to +50 °C
WC3oCOC
1.00 %
-20 °C to +50 °C
WC3oCOD
10.0 %
-20 °C to +50 °C
WC3oCOE
6514881
1%
-30 °C to +45 °C
WC30IRL
5%
-30 °C to +45 °C
CO2
Infrared
6514882
10 %
-30 °C to +45 °C
6514879
50 %
-30 °C to +45 °C
30.0
-20 °C to +50 °C
WC3oHSA
H 2S
Electrochemical
100
-20 °C to +50 °C
WC3oHSB
1000
-20 °C to +50 °C
WC3oHSC
100
-20 °C to +50 °C
WC3oNOA
NO
Electrochemical
300
-20 °C to +50 °C
WC3oNOB
1000
-20 °C to +50 °C
WC3oNOC
10.0
-20 °C to +50 °C
WC3oN2A
NO2
Electrochemical
30.0
-20 °C to +50 °C
WC3oN2B
10.0
-20 °C to +50 °C
WC3oSOA
SO2
Electrochemical
30.0
-20 °C to +50 °C
WC3oSOB
100
-20 °C to +50 °C
WC3oSOC
Cl2
Electrochemical
10.0
-20 °C to +50 °C
WC3oCL2
2000
-20 °C to +50 °C
WC3oH2A
H2
Electrochemical
2%
-20 °C to +50 °C
WC3oH2B
30.0
-20 °C to +50 °C
WC3oHLA
HCl
Electrochemical
100
-20 °C to +50 °C
WC3oHLB
10.0
-20 °C to +50 °C
HCN
WC3oHNA
Electrochemical
30.0
-20 °C to +50 °C
WC3oHNB
100
-20 °C to +40 °C
WC3oNH3
WC30NH3F
100
-40 °C to +40 °C
NH3
Electrochemical
1000
-20 °C to +40 °C
WC3oNH1
WC30NH2
5000
-20 °C to +40 °C
ETO/PO
Electrochemical
30.0
-20 °C to +50 °C
WC3oOET
HF
Electrochemical
10.0
-10 °C to +30 °C
WC3oHFA
O3
Electrochemical
1.00
-20 °C to +50 °C
WC3oO3A
PH3
Electrochemical
1.00
-20 °C to +50 °C
WC3oPH3
ClO2
Electrochemical
3.00
-20 °C to +50 °C
WC3oCLO
COCl2
Electrochemical
3.00
-20 °C to +40 °C
WC3oCCL
Methylene chloride
CTX300-507
Semiconductor
500
-20 °C to +55 °C
Methyl chloride
CTX300-508
Semiconductor
500
-20 °C to +60 °C
CTX300-652
2000
-20 °C to +50 °C
Toluene
Semiconductor
CTX300-657
500
-20 °C to +50 °C
Trichlorethylene
CTX300-655
Semiconductor
500
-20 °C to +60 °C
CTX300-653
2000
-20 °C to +50 °C
Xylene
Semiconductor
CTX300-660
500
-20 °C to +50 °C
Ethanol
CTX300-654
5000
-20 °C to +60 °C
Semiconductor
CTX300-656
500
-20 °C à +50 °C
R12
CTX300-500
Semiconductor
10000
-20 °C to +55 °C
R22
CTX300-501
Semiconductor
2000
-20 °C to +55 °C
R123
CTX300-509
Semiconductor
2000
-20 °C to +55 °C
R134a
CTX300-502
Semiconductor
2000
-20 °C to +55 °C
R11
CTX300-505
Semiconductor
10000
-20 °C to +55 °C
R23
CTX300-506
Semiconductor
10000
-20 °C to +55 °C
R143a
CTX300-511
Semiconductor
2000
-20 °C to +55 °C
R404a
CTX300-512
Semiconductor
2000
-20 °C to +55 °C
R507
CTX300-513
Semiconductor
2000
-20 °C to +55 °C
R410a
CTX300-514
Semiconductor
1000
-20 °C to +55 °C
R32
CTX300-515
Semiconductor
1000
-20 °C to +55 °C
If you have any questions about other gases or ranges, please consult us at [email protected]
Gas
Part Number
Type of sensor
Range (ppm)
Relative humidity uncondensed
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
5 % to 95 % RH
5 % to 95 % RH
5 % to 95 % RH
5 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % à 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
10 % to 95 % RH
Ordering example for CTX 300:
WC3oO2F: - without display Order WC3ØO2F
- with display
Order WC3AO2F
SENSORS TECHNICAL SPECIFICATIONS
Accuracy
(% at PA full scale)
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 2 %
+/- 2 %
+/- 2 %
+/- 2 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 1.5 %
+/- 2 %
+/- 2 %
+/- 3 %
+/- 3 %
+/- 3 %
+/- 3 %
+/- 3 %
+/- 3 %
+/- 3 %
+/- 3 %
+/- 2 %
+/- 1.5 %
+/- 15 %
relative
to alarm threshold
Life span
(in months)
28
36
48
48
48
48
48
60
60
60
60
36
36
36
36
36
36
24
24
36
36
36
24
24
24
18
18
24
24
24
24
24
24
36
12
18
12
24
18
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
Pressure : Atm +/- 10 %, IP 55, NEMA 3 and 3R
T(50)
(seconds)
10
< 20
15
15
15
< 20
< 20
70 (T90)
70 (T90)
70 (T90)
70 (T90)
15
15
15
15
15
15
20
20
15
15
15
50
50
50
50
50
30
30
50
50
50
50
50
50
40
40
50
50
40
40
20
20
40
20
20
20
20
30
30
30
30
30
30
30
30
30
20
20
Pre-calibrated sensors ease maintenance
ACCESSORIES
Gas collector
Calibration cup
Remote calibration cup
Mounting bracket
Bypass adapter
TECHNICAL SPECIFICATIONS
Better performance,
enhanced ergonomics
Enclosure
Polycarbonate housing
Function
Detector-transmitter
Better performance
Display
Highly visible backlight display unit
(optional, gas dependent)
• Excellent sensitivity and signal stability
• 2 mA signal for maintenance mode
• Signal lower than 1 mA for failure mode
Clear readability
• Highly sensitive, lighted display allows local reading
• Effective power-up indication by indicator lights
• Indication of maintenance or fault function
High-Level technology
• Pre-calibrated sensor avoiding the need to use
unstable gases on site for calibration purposes
• Remote sensor unit allowing measurements in even the
most inaccessible places
• High-performance semiconductor type detector
(detection of freon gas, etc.)
Advanced design
• Highly resistant to environmental elements
• Avoids having to use protective covers
Indicator
lights
Link
In operation: green color
(on CTX 300 : 3-wire)
Failure / maintenance: yellow color
2 wires – CTX 300 without display unit
3 wires – CTX 300 with display unit
Cable entry
PG9 cable gland
(outer diameter 6 to 11 mm)
Power supply
15 to 32 V DC
Power
consumption
CTX 300 without display unit: 27 mA
CTX 300 with display unit: 110 mA
Infrared or semiconductor versions: 100mA
Operating
temperature
-20°C to + 50°C, 4°F to + 122°F
Sealing
IP 66, NEMA 3 & 3R
Weight
520 g
Dimensions
130 x 136 x 69 (l x h x d) in mm
Heavy-duty
Certification
• Use of polycarbonate and stainless steel mounting hardware
• Resistant to corrosive agents
• Durable housing
EMC
Type 1 according to EN 50270:06
Impedance
32 ohms max loop for CTX 300
with display unit and for solid states
and CO2 sensor versions
Specifically adapted options
• Removable filters, interchangeable without opening the
housing (which is dust-proof, condensation-proof and
water-resistant)
• Splash guard
• Gas collector cone
• Mounting brackets
• Pitot tubes, floats, heating protective device, etc.
CCSA
– Class 4812 10 – Signal Appliances-Detectors
CSAUS – Class 4812 86 - Signal Appliances-Miscellaneous
128 ohms max loop for
CTX 300 without display unit
69 mm
130 mm
CTX300_Lit_Eng_10July2014
136
mm
www.oldhamgas.com
AMERICAS
Tel.: +1-713-559-9280
Fax: +1-281-292-2860
[email protected]
EUROPE
Tel.: +33-3-21-60-80-80
Fax: +33-3-21-60-80-00
[email protected]
ASIA PACIFIC
Tel.: +86 21 3127 6373
Fax: +86 21 3127 6365
[email protected]