Young Regulator Co. 7100 Krick Rd • Walton Hills, OH 44146 P: 440-232-9700 • F: 440-232-8266 www.youngregulator.com Submit CVR-SRFXX CVR-SFXX or CVR-RFXX Constant Volume Regulator in deep enclosure, accommodates a fire damper Application and Design Constant Volume Regulators (CVR) are designed to limit the airflow into or out of a space. They feature a specifically engineered free area and a wing-like damper (Aero-Gate). When pressure increases, the increased flow causes the Aero-Gate to rise and block more of the free area. The CVR is adjustable to provide various maximum flow profiles over its rated pressure range. (See reverse for performance curves) The product is precision molded of fire resistant plastic and have been used in Europe for years. They are starting to gain a larger market in North America as well. Constant Volume Regulators may contribute to meeting coveted USGBC Leed Building Certification. The CVR-SFXX (supply) and the CVR-RFXX(return) feature the regulator mounted in a rugged 26 gauge galvanized steel enclosure with enough space for a fire damper. The standard square sizes provide for more aesthetic flexibility and reduce costs. For applications that require the use of fire/radiation dampers the CVR-SFXX (supply) and the CVR-RFXX are the perfect solutions. Control the volume of air while ensuring that smoke is not allowed Front View Side Veiw Duct Collar into or out of the space. B E C SIZE INFORMATION Diameter 4” (Adjustable) 5” (Adjustable) 6” (Adjustable) Low 6” (Adjustable) High 8” (Adjustable) 10” (Adjustable) D Flow (@ 0.2inWC-0.8WC) 10 to 30 CFM or 30 to 60 CFM 30 to 60 CFM 60 to 105 CFM 105 to 175 CFM 175 to 300 CFM 300 to 420 CFM STANDARD CONSTRUCTION Construction Safety Ratings Sheet Metal Color QUANTITY Molded in a specialty engineered ABS plastic European Fire and Smoke rated M1. (See UL94V-0, and UL2043) 26 gauge galvanized steel Black SIZE A B 3/4” Mounting Flange (typical 4 plcs) CVR ENCLOSURE LENGTH * DIAMETER (A) WIDTH (B) 4 6x6 5 8x8 6 8x8 8 10 x 10 10 12 x 12 * All Dimensions in inches NOTES PROJECT LOCATION CONTRACTOR DESIGN SPECIFIER Fire Damper (by Others) ENCLOSURE DEPTH (C) 5.25 5.25 5.25 5.25 5.25 CVR installed COLLAR DEPTH (D) 3.5 3.5 4.5 4.5 6.0 TOTAL DEPTH (E) 8.75 8.75 9.75 9.75 11.75 | back | Constant Volume Regulators Performance Data The CVR is a precision control. Choose the size to meet your performance criteria. Each diameter regulator is adjustable over a range of flow rates. Choose the correct part from the table below. Ensure that both fitting diameter and flow rates match your requirements. Adjustment Process Constant Volume Regulator (CVR) Adjustment Scales Regulator Body Aero-Gate Young Nominal Flow Range Noise Body Diameter/ Length Regulator Part # Diameter (in) (CFM) dB(A) Gasket (in) (in) CVR-04-L 4 10-30 26-38 3.74/4.12 2.73 CVR-04 4 30-60 26-44 3.74/4.12 2.73 CVR-05 5 60-105 33-47 4.68/5.06 3.47 CVR-06-L 6 60-105 33-47 5.69/6.07 3.55 CVR-06 6 105-175 34-45 5.69/6.07 3.55 CVR-08 8 175-300 33-53 7.41/7.79 3.55 CVR-10 10 300-420 46-55 9.56/9.94 4.95 Custom Other Profiles available. Contact the factory for custom orders! Edge Seal Adjustment Screw(s) 1. Select the maximum flow rate (in CFM) from the Performance Curve table (right). 2. Note the Adjust Scale number next to the desired flow. 3. Loosen the adjustment screw using a Torx® T-10 bit. 4. Adjust the carriage that holds the Aero-Gate up and down to line up the top of the Carriage with the desired Adjust Scale number. In the picture the CVR is set to 50 on the Adjust Scale. That equates to 30 CFM. 5. Retighten Adjustment Screw. Finger tight is sufficient. Do not over-tighten the screw(s). Constant Volume Regulator Combined Performance Curves CFM 235 224 212 200 188 177 165 153 141 129 118 106 94 82 71 59 47 35 24 12 0 Adjust Scale 400 0 to 220 CFM Adjust CFM Scale 220 to 500 CFM 500 780 200 CFM 380 447 760 360 436 740 410 CFM 175 340 424 720 320 412 700 160 380 300 400 680 280 388 660 140 260 377 640 353 240 365 620 125 220 353 600 325 200 341 580 105 180 330 560 88 160 318 540 300 140 306 520 71 120 294 500 60 100 283 480 53 265 80 271 460 45 35 60 259 440 30 235 40 247 420 25 18 20 235 400 15, 9 0 224 380 0.2 0.4 0.6 0.8 1.0 0.2 0.4 0.6 0.8 1.0 Pressure Drop (inWC) Pressure Drop (inWC)
© Copyright 2024 ExpyDoc