HARGON 350 line extender/end amplifier for DOCSIS 3.1 RF Parameters Forward Channel Bandwidth 85...260 – 1218 MHz Gain @1.2GHz 2 x 37 ± 1 dB Noise figure < 7 / 8.5 dB 1 Flatness 2 90 ÷ 862 MHz 90 ÷ 1006 MHz 90 ÷ 1212 MHz Slope ≥ -0.5 and ≤ +0.5 dB ≥ -0.75 and ≤ +0.75 dB ≥ -1.0 and ≤ +1.0 dB ± 1 dB Output level CTB ≤ -60dBc, flat CSO ≤ -60dBc, flat 2 x 110 dBμV 2 x 113 dBμV Return loss 4 > 18 dB Input testpoint (bi-directional) -20 ± 1.5 dB Output testpoints (directional) -20 ± 0.5 dB Forward gain (A), slope (E) control: A1, E1 (ATG) A2, E2 (ATG) E0 (jumper) 0 – 20 step 1 dB 0 – 20 step 1 dB 0 / 14 dB 3: Reverse Channel Bandwidth 5 – 65...200 MHz Flatness 5 ± 0.5 dB Return loss 6 1.2GHz technology Extended bandwidth in downstream up to 1.2GHz > 18 dB Gain 7 2 x 22 / -8 dB HUM modulation 8 ≤ -60 dBc Possibility of extending bandwidth in upstream up to 200MHz Reverse gain (A), slope (E) control: A3, A4, A5, E3 0 – 20 step 0.5 dB GREEN mode – Intelligent Power Consumption Noise figure 9 < 6 dB 200MHz technology Significant reduction of power consumption through optimization of its use VIG (VECTOR INGRESS GUARD) system compliant Others Voltage range: remote powering mains powering 30 – 65 V AC 230 ± 10% V AC Max. current for RF ports 7A Max. current for AC IN port 4A Power consumption < 11 W Operation temperature range - 40 – 60 ºC Connectors IEC / 2 x F Protection class 10 IP 44 Dimensions (W x L x H) 202 x 172 x 80 mm Weight 2 kg Verification and elimination of the source of ingress in the network JXP configuration Simple and cost-effective configuration of devices through plug-in modules GaN Technology Improved output parameters for analog and digital carriers, at a lower power consumption 1. N.F. < 7dB for 862MHz; N.F. < 7.5dB for ≤ 1002MHz, N.F. < 8.5dB for ≤ 1218MHz typical value 2. Valid 15MHz after the starting frequency of the selected diplex filter 3. Typical value, According to EN50083-3, 0dB interstage slope, 42 channels CENELEC, 4. 18dB for f ≤ 40MHz, 18dB -1.5dB/oct for f >40MHz 5. For 5 – 60MHz with DF65G 6. >16dB for 5MHz < f < 8MHz; > 18dB for f > 8MHz 7. For active return path / passive return path; +/- 1dB 8. For f >16MHz, remote current < 6A @25ºC, typical value 9. Up to 200MHz, with diplex filters, typical value, NF <7 for f=200MHz 10. With AC IN connector; IP 65 without AC IN connector Unless otherwise specified, all specifications are tested with 65/85 diplex filters installed; GREEN=0, at room temperature 25°C www.vector.net HARGON 3730 distribution amplifier for DOCSIS 3.1 RF Parameters Forward Channel Bandwidth 85...260 – 1218 MHz Gain @1,2GHz 2 x 43 ± 0.75 dB Noise figure, typical value < 8 dB Flatness 1 ± 0.75 dB Slope ± 1 dB Output level 2, 3: CTB ≤ -60dBc CSO ≤ -60dBc 118 dBμV 118 dBμV Return loss 4 > 18 dB Input testpoint (bi-directional) -20 ± 1.5 dB Output testpoints (directional) -20 ± 0.5 dB Forward gain (A), slope (E) control: A1, E1 A2, A3 E2, E3 0 – 20 step 0.5 dB 0 – 20 step 0.5 dB 0 – 15 step 0.5 dB Reverse Channel Bandwidth 5 – 65...200 MHz Flatness 5 ± 0.75 dB Return loss 6 > 18 dB Gain 25 / -11 dB HUM modulation 7 ≤ -60 dBc Reverse gain (A), slope (E) control: A4, A5, A6, E4 0 – 20 step 0.5 dB Others 1,2 GHz technology Extended bandwidth in downstream up to 1,2 GHz 200MHz technology Possibility of extending bandwidth in upstream up to 200MHz GREEN mode – Intelligent Power Consumption Voltage range: remote powering 8 Mains powering 30 – 65 V AC 230 ± 10% V AC Max. current for RF ports 10 A Max. current for AC IN port 12A Power consumption 9 36 W Operation temperature range - 40 – 60 ºC Connectors PG11 (others on request) Protection class IP 67 Dimensions (W x L x H) 245 x 215 x 91 mm Weight 3 kg Available versions Significant reduction of power consumption through optimization of its use VIG (VECTOR INGRESS GUARD) system compliant Verification and elimination of the source of ingress in the network GaN Technology Improved output parameters for analog and digital carriers, at a lower power consumption NMS transponder Reduced operating costs thanks to remote monitoring and configuration HHT (Hand Held Terminal) support HARGON 2730 /BP33G 089Y remote powering HARGON 2730 /BP33G 089M mains powering Quick and intuitive configuration of devices, and electronic documentation of the network CMS (Craft Management Software) compliant Easy and convenient network documentation thanks to CMS software 1. Valid 15MHz above the starting frequency of the selected diplex filter 2. According to EN50083-3, 9dB interstage slope, 42 channels CENELEC, typical value 3. GREEN 0 (CTB/CSO = 118/118), GREEN 1 (CTB/CSO = 116/118), GREEN 2 (CTB/CSO = 114/118) 4. 18dB for f ≤ 40MHz, 18dB -1.5dB/oct for f >40MHz 5. 7MHz < f < 63MHz 6. >16dB for 5 – 8MHz; > 18dB for f > 8MHz + 1.5dB/oct. for f>40MHz 7. For f >18MHz, remote current <8A @25ºC, typical value 8. With NMS transponder 30 – 65V AC 9. Without NMS transponder @25ºC @65V AC, GREEN 0; 31W = GREEN 1; 28W = GREEN 2 Unless otherwise specified, all specifications are tested with 65/85 diplex filters installed; GREEN=0, at room temperature 25°C Specifications are subject to change without notice. www.vector.net
© Copyright 2024 ExpyDoc