Explosion-Proof Diverter valves DMN-Westinghouse Operation instructions + Maintenance Safety instructions PTD-II PTD-sp FDV FVV BTD GPD TDV M-TDV 2-TDV 3-TDV ATEX –Approval II 1D / 2GD c II 1D / 3GD c II 1D / - c IMPORTANT: Read before commissioning : • Operation instructions Explosion-Proof Diverter valves. • Operation instructions Standard Diverter valves. (Appendix) and then store carefully for future use ! Customer : Purchase order no. : DMN-Westinghouse Order no. : Type : Serial no. : Year of construction : DMN-Westinghouse Explosion-proof Diverter valves Directive 94/9/EG • Notified body EC-Type examination. EXAM BBG Prüf- und Zertifizier GmbH Dinnendahlstr. 9 44809 Bochum Germany Certificate number BVS 03 ATEX H 046 X. • Notified body in charge of quality surveillance. LCIE 33, Avenue du Général Leclerc 92260 Fontenay aux Roses France Identification number 0081 II 1D/ 2 GD c 1D Internal Diverter valve 2 GD External Diverter valve Zone 20-21-22 Zone 1-21 II 1D/ 3 GD c 1D Internal Diverter valve 3 GD External Diverter valve Zone 20-21-22 Zone 2-22 II 1D/ - c 1D Internal Diverter valve - External Diverter valve Zone 20-21-22 No Zone DMN Machinefabriek Noordwykerhout B.V. 3, Gieterij 2211 WC Noordwijkerhout The Netherlands www.dmn.info Code: DV-Ex-E.B.01.B 06-2008 2 DMN-Westinghouse Explosion-proof Diverter valves General - For the promotion of the life span and correct functioning of DMN-Westinghouse Diverter valves we advise you to respect these operation instructions and to carry out maintenance work accordingly. Should there be any problems, please contact our technical sales department. No liability is accepted for damage and malfunction caused by non-observation of these operation instructions, modification of the diverter valve without written approval of DMN Machinefabriek Noordwykerhout B.V. (hereinafter called DMN). DMN does not accept any liability for damage or accidents resulting from improper use. Copyright Copyright © DMN Machinefabriek Noordwijkerhout B.V. All rights reserved. All information including drawings shown in this manual are covered by copyright. No part of this manual may be reproduced or published in any form or in any way, electronically, by print, photo print, microfilm or any other means without prior written permission from DMN. Code: DV-Ex-E.B.01.B 06-2008 3 DMN-Westinghouse Explosion-proof Diverter valves Contents Page 1. Safety instructions Diverter valves 1.1 General safety instructions 1.2 Symbols 1.3 Responsibilities of management and maintenance personnel 1.4 Applying the safety instructions when installing a valve 1.5 Applying the safety instructions when the valve is in operation 1.6 Applying the safety instructions during maintenance and repair 1.7 Safety instructions for use in potentially explosive atmosphere 5 5 5 6 6 6 6 7 2. Explosion-Proof Diverter valves 2.1 Atex approved equipment 2.2 Type designation 2.3 Intended use 8 8 11 12 3. Installing the Diverter valve in a potentially explosive atmosphere 3.1 FDV-FVV Diverter valves 3.2 TDV Diverter valves 3.3 2-3 TDV Diverter 3.4 PTD-II / PTD-sp Diverter valves 3.4.1 Connection diagram for the plug type diverter Terminal box connection static seal Zone 1-21 Terminal box connection static seal Zone 2-22 Terminal box connection inflatable seal Zone 2-22 3.5 Accessories 12 13 13 14 15 15 18 4. Dismantling, assembling and adjusting instructions 19 5. Inspection and maintenance 5.1 Maintenance every 6 months or after 4,000 operating hours 20 20 Code: DV-Ex-E.B.01.B 06-2008 4 DMN-Westinghouse Explosion-proof Diverter valves 1 Safety instructions Diverter valves 1.1. General safety instructions The safety instructions as described below should be followed by the user when: - installing the valve; maintaining and repairing the valve. The safety instructions should be read carefully both by management and maintenance personnel before carrying out the above operations. Failure to follow these safety instructions, may result in one or more of the following: - the safety of the maintenance personnel could be endangered; the valve may not function correctly; the system which contains the valve may be damaged. Modifications and alterations to the product are not permitted other than by DMN trained personnel, to ensure safe operation. 1.2. Symbols Hazard. Possible consequences: Severe or fatal injuries. Hazardous situation. Possible consequences: Slight or minor injuries. STOP Harmful situation. Possible consequences: Damage to the Diverter valve and the environment. Important Notes on Explosion Protection. Remark. Code: DV-Ex-E.B.01.B 06-2008 5 DMN-Westinghouse 1.3. Explosion-proof Diverter valves Responsibilities of the management and maintenance personnel The management must ensure that: - the maintenance personnel observe the safety instructions, as described in this document; all available means which are necessary for working according to the safety instructions are present; the maintenance personnel possess the necessary skills. Maintenance personnel should follow these safety instructions when carrying out installation, repair and maintenance. 1.4. Applying the safety instructions when installing a Diverter valve After removing the packaging material it is possible to reach the inlet of the diverter. During this operation do not operate Diverter. Do not alter, remove or paint the type specification plates of the valve, drive unit or fitted switches. 1.5. Applying the safety instructions when the valve is in operation During operation of the diverter it must not be possible to reach moving parts like the plug, flap or tube. While the valve is in operation no maintenance or repair work must be carried out. 1.6. Applying the safety instructions during maintenance and repair work When product qualities necessitate supplementary safety instructions and wearing protective clothes, it is obligatory to follow the local safety instructions. Before maintenance and repair work is carried out: - electrical supply to the solenoid valve must be isolated. air pressure to pneumatic cylinder must be isolated. After the maintenance and repair work has been carried out, all safety parts removed during the work should be re-assembled and their operation should be checked. Code: DV-Ex-E.B.01.B 06-2008 6 DMN-Westinghouse 1.7. Explosion-proof Diverter valves Safety instructions for use in potentially explosive atmosphere Explosive concentrations of dust can lead to severe or fatal injuries in connection with hot surfaces, parts under power and moving parts of the Diverter valve. Installation, connection, start-up, maintenance and repair work on the Diverter valve may only be performed by a qualified specialist while taking the following into account: • these instructions • the warning and information signs on the Diverter valve • currently valid national / regional regulations (Explosion protection, Safety, accident prevention) Check if there are any potentially explosive atmosphere, oils, acids, gases, vapours, radiation etc. present during installation, connection, start-up, maintenance and repair work. Remove dust deposits when ignition sources (e.g. sparks through grinding) can be created during installation, connection, start-up, maintenance and repair work. The Diverter valves are intended for industrial systems and may only be used in accordance with the information provided in DMN technical documentation and the information listed on the nameplate. They comply with the applicable standards and regulations and meet the requirements of the directive 94/9/EC. Code: DV-Ex-E.B.01.B 06-2008 7 DMN-Westinghouse Explosion-proof Diverter valves 2 Explosion-proof Diverter valves 2.1 ATEX approved equipment. The following table shows the valve types that can be used as equipment: Executions Pneumatic Actuator Cylinder Type Size PTD-II PTD-sp 50-65-80-100-125-150-200 150-175-200-250-300-350 FDV-P 50-65-80-100-125-150 FDV-F 50-65-80-100-125-150-200-250 FVV-P 50-65-80-100-125-150 FVV-F 50-65-80-100-125-150 1A 2A 3A 1C 2C 3C BTD 65-80-100-125-150-200-250 1A GPD 150-200-250-300 1A 2A 3A TDV 40-50-65-80-100-125-150-200 M-TDV 40-50-65-80-100-125-150-200 Type Size Seal 2-TDV 40-50-65-80-100-125-150 2STA 3STA 2DYN 3DYN 3-TDV 40-50-65-80-100-125-150 2DYN 3DYN Hand operation Electrical Actuator 1H 2H 3H 1E 2E 3E 1H 2H 3H 1E 2E 3E Executions These valves correspond to the design requirements of device group II II 1D/ 2 GD c 1D Internal Diverter valve 2 GD External Diverter valve Zone 20-21-22 Zone 1-21 II 1D/ 3 GD c 1D Internal Diverter valve 3 GD External Diverter valve Zone 20-21-22 Zone 2-22 II 1D/ - c 1D Internal Diverter valve - External Diverter valve Zone 20-21-22 No Zone Code: DV-Ex-E.B.01.B 06-2008 8 DMN-Westinghouse Explosion-proof Diverter valves Ambient temperature Operate Diverter valves at an ambient temperature of –20°C to +40°C. Conveying air temperature The conveying air must not exceed a temperature of +70°C. Surface temperature The surface temperature of the diverter valve depends on the temperature of the product to be handled. The recommended maximum product temperature for the diverter valve is +170°C depending on the type of diverter valve. The temperature increase of the valve by failure is ∆T=20 K. Marked temperature if equipment is subject to type testing (EN-13463-1) ∆T=20 K = measured maximum surface temperature + 5 K The diveter valve without drive, solenoid valve, proximity switch, etc. Maximum surface temperature of the diverter valve without drive, solenoid valve, proximity switch, etc. is 90°C/T5. (calculation: conveying air 70°C +(∆T=20 K) =90°C) If the temperature of the product to be handled can is higher then 70°C than this will influence the surface temperature of the diverter valve. (see table) Product temperature 70°C 80°C 90°C 100°C 110°C 115°C 120°C 130°C 140°C 150°C 160°C 170°C Max. surface temperature 90°C T5 100°C 110°C T4 120°C 130°C 135°C 140°C T3 150°C 160°C 170°C 180°C 190°C Bearing and shaft seal Diverter with standard bearing and shaft seal GPD Diverter with special HTbearing and PTFE lip seal The diverter is equipped with a Explosion-proof solenoid valve, inductive proximity switches, terminal box, etc. with a marking category 2 respectively category 3. The Max. surface temperature depends on the type. Code: DV-Ex-E.B.01.B 06-2008 9 DMN-Westinghouse Explosion-proof Diverter valves Relationship of the maximum surface temperature of the equipment and the minimum ignition temperature of dust cloud and dust layer. Dust cloud. Maximum surface temperature = 2/3 x Minimum Ignition Temperature Dust layer up to 5mm. Maximum surface temperature = Smouldering Temperature – 75 K The plant operator must ensure that any possible dust accumulation does not exceed a maximum thickness of 5 mm in accordance with EN50281-1-2. There must be no flammable solvents within the dust. Code: DV-Ex-E.B.01.B 06-2008 10 DMN-Westinghouse 2.2 Explosion-proof Diverter valves Type designation Example Diverter valve Type Size FDVF 150 Type PTD-II PTD-sp FDVP FDVF FVVP FVVF BTD GPD TDV MTDV 2-TDV 3-TDV Material of construction Execution Material of construction 2 Execution C 40 50 65 80 100 125 150 200 250 300 350 Size 1 2 3 A C E H STA DYN Cast Iron Aluminium Stainless steel Pneumatic Actuator Pneumatic cylinder Electrical Actuator Hand operation Static seal Inflatable seal Code: DV-Ex-E.B.01.B 06-2008 11 DMN-Westinghouse 2.3 Explosion-proof Diverter valves Intended use The DMN-Westinghouse Diverter valves has been specially designed to re-route powders and pellets in pneumatic conveying systems, in a potentially explosive atmosphere. The technical specifications, General assembly and parts list of the Diverter valve are in a separate Operation and maintenance instructions. (see appendix) STOP Material of construction of the Diverter valve must be suited for the product to be handled. 3 Installing the Diverter valve in a potentially explosive atmosphere. Remove all packing material and preservatives. Check for any transport damage. Check valve interior is free from foreign material. Check if there are any potentially explosive atmosphere, oils, acids, gases, vapours, radiation etc. present during installation. Please follow safety instructions of chapter 1 when installing the Diverter valve in a potentially explosive atmosphere. Does the following information on the nameplate of the Diverter valve correspond to the potentially explosive on-site atmosphere. Pay specific attention to: • Unit group • Explosion-proof category • Dust- or Gas area • Temperature class • Maximum surface temperature Do not operate Diverter. Danger to fingers and hands. Code: DV-Ex-E.B.01.B 06-2008 12 DMN-Westinghouse STOP Explosion-proof Diverter valves When installing the valve make sure it is not unevenly loaded by external forces or vibrations. Always ground the Diverter valve, use the earth-stud. Check that the electrical leakage resistance is less than 106 Ω. 3.1 FDV-FVV Diveter valve. FDV-P with Pipe bonded in Body. Check that the electrical leakage resistance is less than 106 Ω between pipe and Body. FDV Diverter with Pneumatic cylinder. The drive must be protected by a guard. 3.2 TDV Diverter valve. Earth the steel spiral of the tube at both end. Check that the electrical leakage resistance is less than 106 Ω between connection tube. If the material of the tube is non-conductive then the distance between the steel spirals must be <30mm and the material thickness from the inner tube to the spiral must be <2mm. The drive must be protected by a guard. Code: DV-Ex-E.B.01.B 06-2008 13 DMN-Westinghouse 3.3 Explosion-proof Diverter valves 2-3 TDV The 2-TDV unit is driven by means of an pneumatic actuator actuated by a solenoid valve. Indication of pipe changeover is by means of position confirmation switches in control box. The 3-TDV is driven by means of an pneumatic 3-position actuator and a pneumatic cylinder for to get a perfect alignment of the swan-neck and selected nozzle. Connections for all electrical components are in a terminal box and control box. Indication of pipe changeover is by means of position confirmation switches in control box. Moving parts must be protected by a guard. When assembling the protection guard make sure that no ignition sources (e.g. sparks through contact) can be created. Code: DV-Ex-E.B.01.B 06-2008 14 DMN-Westinghouse 3.4 Explosion-proof Diverter valves PTD-II / PTD-sp Diverter valve. The PTD-II plug type diverter is equipped as standard with a pneumatic cylinder, electrically operated 5/2 solenoid-solenoid valve, inductive proximity switches and terminal box. The PTD-sp plug type diverter is equipped as standard with a pneumatic actuator, electrically operated 5/2 bistable valve, inductive proximity switches and terminal box. 3.4.1 Connection diagram for the plug type diverter Terminal box connection static seal Zone 1-21. Solenoid valve. Code: DV-Ex-E.B.01.B 06-2008 15 DMN-Westinghouse Explosion-proof Diverter valves Position switches. Terminal box connection static seal Zone 2-22. Solenoid valve. Position switches. Code: DV-Ex-E.B.01.B 06-2008 16 DMN-Westinghouse Explosion-proof Diverter valves Terminal box connection inflatable seal Zone 2-22 Solenoid valve / pressure switch. Position switches. After assembly test run the valve. Code: DV-Ex-E.B.01.B 06-2008 17 DMN-Westinghouse 3.5 Explosion-proof Diverter valves Accessories II 1D/ 2 GD c 1D Internal Diverter valve 2 GD External Diverter valve Zone 20-21-22 Zone 1-21 II 1D/ 3 GD c 1D Internal Diverter valve 3 GD External Diverter valve Zone 20-21-22 Zone 2-22 II 1D/ - c 1D Internal Diverter valve - External Diverter valve Zone 20-21-22 No Zone Only use • Solenoid valve • Proximity switch • Pressure switch • Terminal box • Electrical Actuator that are CE marked and with a ATEX-approval equal to or better than that of the diverter valve. Please study the operation instructions supplied by the manufacturer. Does the following information on the nameplate of the • Solenoid valve • Proximity switch • Pressure switch • Terminal box • Electrical Actuator correspond to the potentially explosive on-site atmosphere. Pay specific attention to: • Unit group • Explosion-proof category • Dust- or Gas area • Temperature class • Maximum surface temperature Drive According to the ATEX directive the maximum velocity must not be higher then 1 m/s and the maximum power of the motor gear unit is not higher then 4 kW. Code: DV-Ex-E.B.01.B 06-2008 18 DMN-Westinghouse 4 Explosion-proof Diverter valves Dismantling and assembly instructions Diverter valve Also read the attached standard operation instructions for the Diverter valve Dismantling and assembly instructions for the valve are in the attached standard operation instructions. In case of repair work to the valve, please follow safety instructions of chapter 1. - Turn off the electrical supply, lock the switch and/or remove the fuses; Close the compressed air supply. DMN-Westinghouse valves have been manufactured with great care. - do not use coarse tools; - avoid damage such as scratches, burrs, etc.; - clean all components thoroughly. After assembly test run the valve. Code: DV-Ex-E.B.01.B 06-2008 19 DMN-Westinghouse 5 Explosion-proof Diverter valves Inspection and Maintenance The interval between overhauls will vary according to the product being handled and should be based on total operating time. To a large degree the rate of wear for a particular application will be ascertained by practical experience. It is recommended that the complete Diverter valve is dismantled for cleaning, inspection and overhaul as necessary at regular intervals. The plant operator must ensure that any possible dust accumulation does not exceed a maximum thickness of 5 mm in accordance with EN50281-1-2. 5.1 Maintenance every 6 months or after 4,000 operating hours - Check the operation of the diverter valve. Check diverter valve for erosion and corrosion damage. Code: DV-Ex-E.B.01.B 06-2008 20
© Copyright 2025 ExpyDoc