EA43210/EA43310- Ed1 RAILWAY SIGNALING CABLES, A-2Y2YV UV Resistant Control cable (H115/ H95) RoHs Compliant SPECIFICATIONS DB AG 416.0113 (formerly Dlk 1.013.107y) DB AG 416.0114 (formerly Dlk 1.013.110y) DESCRIPTION AND APPLICATION Cables from 1 to 50 PE insulated conductors of 0.9, 1.4 and 1.8 mm. Conductors are stranded in concentric layers to form the core which is protected by a reinforced polyethylene sheath. They are used as control cables up to 100 Hz signals, especially in rail infrastructures. Suitable for installation in ducts or directly buried. CONSTRUCTION Conductors: Annealed copper solid wire, 0.9, 1.4 and 1.8 mm diameter. Insulation: Solid polyethylene .(2Y) Cabling element: PE insulated conductors + 2 insulation-perforated conductors of 0,5 mm (≥14 conductors) to detect water presence. Lay-up. Stranded into Layers. Core wrapping: non-hygroscopic polyester tape longitudinally applied with overlap. Outer sheath: Reinforced polyethylene. (2YV) Sheath marks : The sheath shall be marked, at irregular intervals with the following information: o o SignalCable/A-2Y2YV/Cable type + S + Capacitance: i.e 20x1x0,9 S (H115)/ Dlk 1.1013.107y Other type of marks according to the costumer pág. 1/3 EA43210/EA43310- Ed1 RAILWAY SIGNALING CABLES, A-2Y2YV ELECTRICAL CHARACTERISTICS (20ºC) Conductor resistance (Ω/km) Max admissible intensity (A) Air at 30ºC Pipe at 30ºC Minimum insulation resistance (MΩxkm, 20ºC, 500 V) Capacitance (nF/km, 800 Hz) Dielectric Strength (Vdc, 60 s) conductor – conductor (H115/ H95) 0,9 mm 1,4 mm 1,8 mm ≤ 28.9 ≤11.9 ≤7.2 4 3 7 5 9 7 ≥10.000 ≤115 ≥10.000 ≤95 ≥10.000 ≤95 3500 3500 3500 MECHANICAL CHARACTERISTICS Operating temperature range : from -10º C to +60º C Storage temperature range: from -40ºC to + 60ºC Minimum radius of curvature: 10 x Rcable 2 2 Maximum pulling strength: 50 N/mm x total copper conductor cross section (mm ) SIZE, DIMENSIONS AND WEIGHTS Diameter : 0.90 mm (H115) Code no. conductor Diameter : 1.4 mm (H95) Cable Diam. Approx. weight Delivery length (mm) (kg/km) (m) Drum type Code no. conductor Cable Diam. Approx. weight Delivery length (mm) (kg/km) (m) Drum type EA4321090000400N 4 8,30 65,72 2000 B08W000 EA43310A4001000N 10 15,80 270,45 2000 BA4W000 EA4321090000700N 7 9,30 92,56 2000 BA0W000 EA43310A4001600N 16 17,80 398,60 2000 BA4W000 EA4321090001000N 10 10,80 122,43 2000 BA0W000 EA43310A4002000N 20 19,10 477,79 2000 BA4W000 EA4321090001600N 16 11,80 174,20 2000 BA2W000 EA43310A4002400N 24 21,40 569,40 2000 BA6W000 EA4321090002000N 20 12,40 205,45 2000 BA2W000 EA43310A4003000N 30 23,60 698,75 2000 BA6W000 EA4321090002400N 24 13,90 242,20 2000 BA4W000 EA43310A4004000N 40 24,40 889,40 2000 BA6W000 EA4321090003000N 30 14,90 289,60 2000 BA4W000 EA43310A4005000N 50 28,40 1100,70 2000 BB0W000 EA4321090004000N 40 15,50 361,90 2000 BA4W000 EA4321090005000N 50 17,60 443,50 2000 BA6W000 Diameter : 1.8 mm (H95) Code no. conductor Cable Diam. Approx. weight Delivery length (mm) (kg/km) (m) Drum type EA432JRA8001000N 10 16,60 364,73 2000 BA4W000 EA432JRA8001600N 16 18,70 542,60 2000 BA4W000 EA432JRA8002000N 20 19,60 662,52 2000 BA4W000 EA432JRA8002400N 24 22,80 792,27 2000 BA6W000 EA432JRA8003000N 30 24,9 975,10 2000 BA8W000 EA432JRA8004000N 40 25,80 1255,60 2000 BA8W000 EA432JRA8005000N 50 30,4 1575,20 2000 BB0W000 pág. 2/3
© Copyright 2025 ExpyDoc