RAILWAY SIGNALING CABLES, A-2Y2YV (H115/ H95)

EA43210/EA43310- Ed1
RAILWAY SIGNALING CABLES, A-2Y2YV
UV Resistant
Control cable
(H115/ H95)
RoHs Compliant
SPECIFICATIONS
DB AG 416.0113 (formerly Dlk 1.013.107y)
DB AG 416.0114 (formerly Dlk 1.013.110y)
DESCRIPTION AND APPLICATION
Cables from 1 to 50 PE insulated conductors of 0.9, 1.4 and 1.8 mm. Conductors are
stranded in concentric layers to form the core which is protected by a reinforced
polyethylene sheath. They are used as control cables up to 100 Hz signals, especially in
rail infrastructures. Suitable for installation in ducts or directly buried.
CONSTRUCTION







Conductors: Annealed copper solid wire, 0.9, 1.4 and 1.8 mm diameter.
Insulation: Solid polyethylene .(2Y)
Cabling element: PE insulated conductors + 2 insulation-perforated conductors
of 0,5 mm (≥14 conductors) to detect water presence.
Lay-up. Stranded into Layers.
Core wrapping: non-hygroscopic polyester tape longitudinally applied with
overlap.
Outer sheath: Reinforced polyethylene. (2YV)
Sheath marks : The sheath shall be marked, at irregular intervals with the
following information:
o
o
SignalCable/A-2Y2YV/Cable type + S + Capacitance: i.e 20x1x0,9 S (H115)/ Dlk
1.1013.107y
Other type of marks according to the costumer
pág. 1/3
EA43210/EA43310- Ed1
RAILWAY SIGNALING CABLES, A-2Y2YV
ELECTRICAL CHARACTERISTICS (20ºC)
Conductor resistance (Ω/km)
Max admissible intensity (A)
Air at 30ºC
Pipe at 30ºC
Minimum insulation resistance (MΩxkm, 20ºC, 500 V)
Capacitance (nF/km, 800 Hz)
Dielectric Strength (Vdc, 60 s)
conductor – conductor
(H115/ H95)
0,9 mm
1,4 mm
1,8 mm
≤ 28.9
≤11.9
≤7.2
4
3
7
5
9
7
≥10.000
≤115
≥10.000
≤95
≥10.000
≤95
3500
3500
3500
MECHANICAL CHARACTERISTICS
Operating temperature range : from -10º C to +60º C
Storage temperature range: from -40ºC to + 60ºC
Minimum radius of curvature: 10 x Rcable
2
2
Maximum pulling strength: 50 N/mm x total copper conductor cross section (mm )
SIZE, DIMENSIONS AND WEIGHTS
Diameter : 0.90 mm (H115)
Code
no.
conductor
Diameter : 1.4 mm (H95)
Cable
Diam.
Approx.
weight
Delivery
length
(mm)
(kg/km)
(m)
Drum
type
Code
no. conductor
Cable
Diam.
Approx.
weight
Delivery
length
(mm)
(kg/km)
(m)
Drum
type
EA4321090000400N
4
8,30
65,72
2000
B08W000
EA43310A4001000N
10
15,80
270,45
2000
BA4W000
EA4321090000700N
7
9,30
92,56
2000
BA0W000
EA43310A4001600N
16
17,80
398,60
2000
BA4W000
EA4321090001000N
10
10,80
122,43
2000
BA0W000
EA43310A4002000N
20
19,10
477,79
2000
BA4W000
EA4321090001600N
16
11,80
174,20
2000
BA2W000
EA43310A4002400N
24
21,40
569,40
2000
BA6W000
EA4321090002000N
20
12,40
205,45
2000
BA2W000
EA43310A4003000N
30
23,60
698,75
2000
BA6W000
EA4321090002400N
24
13,90
242,20
2000
BA4W000
EA43310A4004000N
40
24,40
889,40
2000
BA6W000
EA4321090003000N
30
14,90
289,60
2000
BA4W000
EA43310A4005000N
50
28,40
1100,70
2000
BB0W000
EA4321090004000N
40
15,50
361,90
2000
BA4W000
EA4321090005000N
50
17,60
443,50
2000
BA6W000
Diameter : 1.8 mm (H95)
Code
no.
conductor
Cable
Diam.
Approx.
weight
Delivery
length
(mm)
(kg/km)
(m)
Drum
type
EA432JRA8001000N
10
16,60
364,73
2000
BA4W000
EA432JRA8001600N
16
18,70
542,60
2000
BA4W000
EA432JRA8002000N
20
19,60
662,52
2000
BA4W000
EA432JRA8002400N
24
22,80
792,27
2000
BA6W000
EA432JRA8003000N
30
24,9
975,10
2000
BA8W000
EA432JRA8004000N
40
25,80
1255,60
2000
BA8W000
EA432JRA8005000N
50
30,4
1575,20
2000
BB0W000