Test report No. 2014-1031

Exova Warringtonfire, Frankfurt
Industriepark Höchst, C369
Frankfurt am Main
D-65926
Germany
T : +49 (0) 69 305 3476
F : +49 (0) 69 305 17071
E : [email protected]
W: www.exova.com
Test report
No. 2014-1031
issued 23.01.2014
Applicant:
VS-Vereinigte Spezialmöbelfabriken GmbH & Co. KG
Hochhäuserstraße 8
D – 97941Tauberbischofsheim
Date of order:
Date of sampling:
Date of arrival:
Date of test:
18.12.2013
no official sampling of the specimen by a representative
of Exova Warringtonfire, Frankfurt
18.12.2013
07.01.2014
Order:
Testing of the ignitability according to DIN EN 1021-1 and -2 (April 2006)
With assessment according to DIN 66084
Description / designation of the test object
ClubLounge, Seat and Couchelement
CS CulturalShit / Landscape / Soft Seating
Description of the relevant test procedure
DIN EN 1021 – 1 + -2 (April 2006)
DIN 66084
Registered Office: Exova GmbH, Industriepark Höchst, C369, Frankfurt, D-65926, Registered Company No. HRB 83049
Ust-Id Nr. DE259957713
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
page 2 of 9
1. Description of the test material
1.1 Details of the customer:
ClubLounge, Seat and Couchelement
CS CulturalShit / Landscape / Soft Seating
Specimen composition:
Cover: Stamskin Top (attached sheet)
Upholstered Seat: Carpenter RF40065
Upholstered Back: Carpenter RF60045
PP-Slip Sheet: VAL, Karle + Hartmann
-> attached data sheets
Intende end use of product: Public Building / School
1.2 At the sample preparation by Exova Warringtonfire, Frankfurt determined values:
Leather with fabric on foam
(Foam an in the description)
Imitation leather
Fleece
Colour:
grey
white
Thickness
1 mm
Square weight:
778 g/m²
13 g/m²
Imitation leather
Fleece
Colour:
blue
white
Thickness
1 mm
Square weight:
786 g/m²
13 g/m²
Before the test, the samples were conditioned at 23°C and 50% humidity.
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
page 3 of 9
2. Test results
2.1
Testing of the burning behaviour according to DIN EN 1021-1
(ignition source: cigarette)
Leather grey with Fleece
1
2
Unsafe escalating combustion
no
no
Test assembly consumed
no
no
Smolder to extremities
no
no
smolder through thickness
no
no
smolder more than an hour
no
no
More than 100mm from source
no
no
Unsafe escalating combustion
no
no
Test assembly consumed
no
no
Flames to extremities
no
no
Flames through thickness
no
no
Flames > 120 seconds
no
no
Specimen no.
Smoldering criteria:
Flaming criteria:
Enter "yes" if criteria exceeded or "no" if criteria not exceeded
Remarks:
The cigarette 1 burn out after 4:30 (min.:sec.)
The cigarette 2 burn out after 4:35 (min.:sec.)
Test result:
no ignition
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
page 4 of 9
2.2
Testing the burning behaviour according to DIN EN 1021-2
(ignition source: gas flame)
1
2
3
Unsafe escalating combustion
no
no
no
Test assembly consumed
no
no
no
smolder to extremities
no
no
no
smolder through thickness
no
no
no
smolder more than an hour
no
no
no
More than 100mm from source
no
no
no
Unsafe escalating combustion
no
no
no
Test assembly consumed
no
no
no
Flames to extremities
no
no
no
Flames through thickness
no
no
no
Flames > 120 seconds
no
no
no
specimen no.
Smoldering criteria:
Flaming criteria:
Enter "yes" if criteria exceeded or "no" if criteria not exceeded
Remarks:
none
Test result:
no ignition
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
2.3
page 5 of 9
Testing of the burning behaviour according to DIN EN 1021-1
(ignition source: cigarette)
Leather blue with Fleece
1
2
Unsafe escalating combustion
no
no
Test assembly consumed
no
no
Smolder to extremities
no
no
smolder through thickness
no
no
smolder more than an hour
no
no
More than 100mm from source
no
no
Unsafe escalating combustion
no
no
Test assembly consumed
no
no
Flames to extremities
no
no
Flames through thickness
no
no
Flames > 120 seconds
no
no
Specimen no.
Smoldering criteria:
Flaming criteria:
Enter "yes" if criteria exceeded or "no" if criteria not exceeded
Remarks:
The cigarette 1 burn out after 4:40 (min.:sec.)
The cigarette 2 burn out after 4:35 (min.:sec.)
Test result:
no ignition
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
page 6 of 9
2.4
Testing the burning behaviour according to DIN EN 1021-2
(ignition source: gas flame)
1
2
3
Unsafe escalating combustion
no
no
no
Test assembly consumed
no
no
no
smolder to extremities
no
no
no
smolder through thickness
no
no
no
smolder more than an hour
no
no
no
More than 100mm from source
no
no
no
Unsafe escalating combustion
no
no
no
Test assembly consumed
no
no
no
Flames to extremities
no
no
no
Flames through thickness
no
no
no
Flames > 120 seconds
no
no
no
specimen no.
Smoldering criteria:
Flaming criteria:
Enter "yes" if criteria exceeded or "no" if criteria not exceeded
Remarks:
none
Test result:
no ignition
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
3.
page 7 of 9
Appearance of the specimen after the test
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
3.1
page 8 of 9
Appearance of the specimen after the test
25.08.2014
Test report no. 2014-1031 issued 23.01.2014
4.
page 9 of 9
Assessment
The in chapter one described material fulfils the requirements:
according to DIN EN 1021-1 (April 2006):
no ignition
(ignition source: glowing cigarette)
according to DIN EN 1021-2 (April 2006) :
no ignition
(ignition source: gas flame )
The tested material passed the requirements to classes P-b and P-c according to DIN 66084
5. Special comment
The fire test result is valid only for in section 1 described material.
In the composition with other materials (for example coatings, deposits) the burning behaviour could
be influenced unfavourable that the above classification is not any longer valid.
The burning behaviour in composition with other materials has to be tested separately.
Frankfurt, the 21.08.2014
H. Anders
Tester in charge
Dipl.-Ing. T. Zachäus
Laboratory Supervisor
The results of the tests relate only to the behaviour of the test specimen which is designated on the top.
Test reports are only allowed to be published or reproduced, not changed in form and tenor without permission of the Exova Warringtonfire,
Frankfurt. The abridged account of a test report is only allowed with the agreement of the Exova Warringtonfire, Frankfurt.
This test report is a translation of the German version 2014-1031 (issued 23.01.2014). In case of doubt only the German version is valid
This test report contains 9 pages
25.08.2014