ICC-ES Evaluation Report ESR-2136 Reissued May 1, 2013 This report is subject to renewal June 1, 2014. www.icc-es.org | (800) 423-6587 | (562) 699-0543 DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation Section: 07 25 00—Water-Resistive Barriers/Weather Barriers REPORT HOLDER: PACTIV BUILDING PRODUCTS 2100 RIVEREDGE PARKWAY, SUITE 175 ATLANTA, GEORGIA 30328 (800) 241-4402 www.green-guard.com EVALUATION SUBJECT: GREENGUARD® FANFOLD AND INSULATIVE FOAM BOARDS AND ALSIDE PLATINUM SERIES™ INSULATION 1.0 EVALUATION SCOPE Compliance with the following codes: ® 2009 International Building Code (IBC) ® 2009 International Residential Code (IRC) ® 2009 International Energy Conservation Code (IECC) Other Codes (see Section 8.0) Properties evaluated: Surface-burning characteristics Thermal resistance (R-value) Attic and crawl space installation Water-resistive barrier 2.0 USES The GreenGuard® products recognized in this report, described in Table 1, are nonstructural foam plastic insulative boards used in interior applications, exterior walls and as components of nonclassified (nonrated) roof covering systems. Additionally, the products are used as alternatives to the water-resistive barrier requirements of IBC Sections 1404.2 and 2510.6, and IRC Section R703, when installed on exterior walls as described in Section 4.4 of this report. ® The Greenguard insulation boards listed in Table 1 of this report are also sold under the Alside Platinum Series™ Insulation name. 3.0 DESCRIPTION 3.1 General: The GreenGuard® insulations consist of an extruded polystyrene foam plastic core, with or without various combinations of facers, and are available in semirigid 1 boards or “fanfolded” bundles. They range from /4 to A Subsidiary of the International Code Council ® 3 /4 inch (6.4 to 19.1 mm) thick. Table 1 contains detailed product descriptions for the various GreenGuard® products ® recognized in this report. GreenGuard products are available in 4-foot-wide (1.2 m) boards in lengths up to 50 feet (15.2 m). 3.2 Joint-sealing Tapes: 3.2.1 General: Joint-sealing tapes are used in conjunction with the insulation boards to seal joints between edges of the boards, when installation is as an alternative water-resistive barrier. The installation of the tape is described in Section 4.4. 3.2.2 GreenGuard® Flashing Tape: The tape is a polyester-faced self-adhering flashing tape with a butyl adhesive. The tape is nominally 0.020 inch thick (0.51 mm) and is produced in minimum 2-inch-wide (51 mm) rolls. 3.2.3 GreenGuard® SuperStretch™ Tape: The tape is an EPDM rubber-faced, self-adhering flashing tape with a butyl adhesive. The tape is nominally 0.052 inch thick (1.32 mm) and is produced in minimum 7-inch-wide (178 mm) rolls. ® 3.2.4 GreenGuard Contractor Sheathing/Housewrap Custom Tape: The tape is a polypropylene-faced self-adhering flashing tape with an acrylic adhesive. The tape is nominally 0.002 inch thick (0.051 mm) and is 1 produced in 2 /2-inch-wide (64 mm) rolls. ® 3.2.5 GreenGuard Housewrap: A polyolefin waterresistive barrier, as described in ICC-ES report ESR-2906. 3.2.6 Surface-burning Characteristics: The extruded polystyrene core of the GreenGuard® products described in Table 1 has a flame-spread index of less than 25 and a smoke-developed index of less than 450 when tested in accordance with ASTM E 84 (UBC Standard 8-1) at a 3 maximum thickness of /4 inch. 3.2.7 Thermal Resistance (R-value): Table 1 lists the R-values reported for each product. 4.0 INSTALLATION 4.1 General: The GreenGuard® products recognized in this report must be installed in accordance with the manufacturer’s published installation instructions and this report. When used on exterior wall applications where the exterior and interior wall coverings are fastened through the insulation boards to structural supports, the maximum insulation board thickness is 3/4 inch (19.1 mm). 4.2 Thermal Barrier: Except as noted in Section 4.3, The GreenGuard® products must be protected from the interior of the building by an approved 15-minute thermal barrier in accordance with IBC Section 2603.4 or IRC Section R316.4. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. 1000 Copyright © 2012 Page 1 of 4 ESR-2136 | Most Widely Accepted and Trusted In cold storage room applications, both the interior surface and the room side surface of walls and ceilings must be covered with a thermal barrier complying with the applicable code. The length of the fasteners for the thermal barrier must be increased to accommodate the thickness of the insulation board. 4.3 Attics and Crawl Spaces: The GreenGuard® products, whether installed as an alternate water-resistive barrier or with a separate code-complying water-resistive barrier on the exterior face of the wall, may be installed on vertical (wall) surfaces in attics and crawl spaces with no covering applied to the interior side of the foam plastic, provided all of the following conditions are met: a. Entry to the attic or crawl space is only to service utilities, and no storage is permitted. b. There are no interconnected attic or crawl space areas. c. Air in the attic or crawl space is not circulated to other parts of the building. d. The total thickness of GreenGuard® does not exceed 3 /4 inch (19.1 mm). e. Attic ventilation is provided when required by IBC Section 1203.2, or IRC Section R806, as applicable. Under-floor (crawl space) ventilation is provided when required by IBC Section 1203.3 or IRC Section R408.1, as applicable. f. Combustion air is provided in accordance with IMC Sections 701, as applicable. 4.4 Water-resistive Barrier (New Construction Application): 4.4.1 General: The GreenGuard® products described in this report may be used as alternatives to the waterresistive barrier for exterior walls prescribed in the applicable code, when installed in accordance with one of the methods described in Section 4.4.2, 4.4.3 or 4.4.4. Windows are installed in accordance with the window manufacturer’s installation instructions. Prior to installation of the exterior cladding, the insulation is inspected and any damaged insulation repaired using GreenGuard® Contractor Sheathing/Housewrap Custom Tape. During ® the installation of a window, GreenGuard Flashing or ® GreenGuard SuperStretch with a minimum width of 4 inches (102 mm) is installed in water-shedding fashion (shingle fashion) in accordance with the Pactiv ® GreenGuard Flashing Installation Guide. ® PLYGOOD Ultra and 4.4.2 GreenGuard ® GreenGuard : The insulation board is aligned with the bottom edge of the wall, with the length dimension running vertically. The vertical joints must occur over framing members or are backed. Horizontal seams or joints may be unbacked. The framing members must be spaced a maximum of 16 inches (406 mm) on center. The insulation is attached using 11/2-inch-long (38 mm) ring shank nails with 1-inch-diameter (25.4 mm) plastic caps, spaced 16 inches (406 mm) on center around the perimeter and at all vertical framing members. At pipe or other small penetrations, gaps are sealed using a silicone sealant complying with ASTM C 920, Type S, Grade NS, Class 25, or an expanding spray foam sealant complying with AAMA 812. All horizontal and vertical insulation board seams are ® sealed with GreenGuard Contractor Sheathing/Housewrap Custom Tape. 4.4.3 GreenGuard® Fanfold Siding Underlayments Installed Using Flanged Windows: Several feet of the ® GreenGuard Fanfold bundle are unfolded and aligned with the bottom edge of the wall sheathing, with the length Page 2 of 4 ® dimension running horizontally. The GreenGuard fanfold is attached using common roofing nails spaced 24 inches (610 mm) on center around the perimeter and at all vertical framing members. At pipe or other small penetrations, gaps are sealed using a silicone sealant or an expanding spray foam sealant. All horizontal and vertical insulation board seams are sealed using GreenGuard® Contractor Sheathing/Housewrap Custom Tape or GreenGuard® Flashing Tape, or by using strips of 16-inch-wide (406 mm) ® ® GreenGuard Housewrap and GreenGuard Flashing Tape to create a z-furring joint treatment in accordance with the manufacturer’s published installation instructions. ® 4.4.4 GreenGuard Fanfold Siding Underlayments Installed Using Nonflanged Windows: Several feet of the GreenGuard® Fanfold bundle are unfolded and aligned with the bottom edge of the wall sheathing, with the length dimension running horizontally. The GreenGuard® fanfold is attached using common roofing nails spaced 24 inches (610 mm) on center around the perimeter and at all vertical framing members. Framing members must be spaced a maximum of 16 inches (406 mm) on center. At pipe or other small penetrations, gaps are sealed using a silicone sealant complying with ASTM C 920, Type S, Grade NS, Class 25, or an expanding spray foam sealant complying with AAMA 812. All horizontal and vertical insulation board seams are sealed using GreenGuard® Contractor ® Sheathing/Housewrap Custom Tape or GreenGuard Flashing Tape, or by using strips of 16-inch-wide (406 mm) GreenGuard® Housewrap and GreenGuard® Flashing Tape to create a z-furring joint treatment. Aluminum brickmold caps are formed for windows. Sill, jamb and head sections are formed with a minimum 2-inch-wide (51 mm) flange. All brickmold sections are installed in water-shedding fashion (shingle-fashion) and all joints are sealed with silicone sealant complying with ASTM C 920, Type S, Grade NS, Class 25. GreenGuard® Flashing or ® GreenGuard SuperStretch is installed with a minimum 4-inch (102 mm) width in water-shedding fashion (shingle fashion) so that it overlaps the brickmold sections. Windows are installed in accordance with the window manufacturer’s installation instructions. Prior to installation of the exterior cladding, the insulation is inspected and any damaged insulation is repaired using GreenGuard® Contractor Sheathing/Housewrap Custom Tape. 5.0 CONDITIONS OF USE The Pactiv GreenGuard® and Alside Platinum Series™ insulation products described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The insulation products must be installed in accordance with the manufacturer’s published installation instructions, subject to the conditions of this report and the applicable code. In the event of a conflict, this report governs. 5.2 The insulation boards, when installed on the exterior face of exterior walls, must be covered with an approved exterior wall cladding that is structurally adequate to resist the prescribed wind pressures set forth in the applicable code. Where the boards are not installed as an alternative water-resistive barrier as described in Section 4.4 of this report, the boards must be covered by a water-resistive barrier complying with the requirements of the applicable code. 5.3 Use of the insulation boards to structurally resist transverse, racking-shear or vertical loadings is outside the scope of this report. The walls must be braced in accordance with the requirements of the applicable code. ESR-2136 | Most Widely Accepted and Trusted Page 3 of 4 5.4 The insulation boards must not be used as a nailing base for exterior siding materials. All nailing must be made into the wall framing as required by the siding manufacturer’s instructions or the applicable code. 5.5 In areas where the probability of termite infestation is “very heavy” and the insulation boards are installed on buildings containing wood frame construction, the installation must meet the requirements of IBC Section 2603.8 or IRC Section R318.4, as applicable. 5.6 The insulation boards must be separated from the interior of the building by an approved thermal barrier of 1/2-inch-thick (12.7 mm) gypsum wallboard or equivalent 15-minute thermal barrier in accordance with the applicable code, except when installed in attics and crawl spaces in accordance with Section 4.3 of this report. 5.7 The use of insulation boards in roof covering systems is limited to use where nonclassified (non-rated) roof covering systems are permitted by the applicable code and where the insulation is separated from the interior of the building by an approved 15-minute thermal barrier. 5.8 When use is in the construction of walls, a vapor retarder must be installed in accordance with IBC Section 1405.3 or IRC Section R601.3. 5.9 The GreenGuard® insulation boards are manufactured at the Pactiv plants located in Winchester, Virginia, and Chippewa Falls, Wisconsin, under a quality control program with inspections provided by UL LLC (AA-668). 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Foam Plastic Insulation (AC12), dated June 2012. 6.2 Data in accordance with the ICC-ES Acceptance Criteria for Foam Plastic Panels Used as Weatherresistive Barriers (AC71), dated February 2003 (editorially revised June 2008). 7.0 IDENTIFICATION Each GreenGuard® or Alside Platinum Series™ product, or the product packaging must bear the Pactiv Building Products name and address, the product name, the flamespread and smoke-developed indices, the R-value, the name of the inspection agency (UL LLC ) and the evaluation report number (ESR-2136). Additionally, joint sheathing tape must bear the Pactiv Building Products name, the product name and the evaluation report number (ESR-2136). 8.0 OTHER CODES 8.1 In addition to the codes referenced in Section 1.0, the products described in this report were evaluated for compliance with the requirements of the following codes: ® 2006 International Building Code (2006 IBC) ® 2006 International Residential Code (2006 IRC) 2006 International Energy Conservation Code ® (2006 IECC) The products comply with the above-mentioned codes as described in Section 2.0 through 7.0 of this report, except as noted below: Installation: See Section 4.2, except the interior of the building must be separated from the insulation boards with a thermal barrier complying with Section R314.4 of the 2006 IRC. Special Uses—Attics and Crawl Spaces: See Section 4.3, except combustion air is provided in accordance with Section 701 and 703 of the 2006 International Mechanical Code®. Conditions of Use: See Section 5.0, except use of the insulation boards in areas of “very heavy” termite infestation must be in accordance with 2006 IRC Section R320.5. Also see Section 5.8, except a vapor retarder must be installed in accordance with Sections R318.1 and N1102.5 of the 2006 IRC and Sections 402.5 and 502.5 of the 2006 IECC. 6.3 Reports of room corner testing in accordance with UBC Standard 26-3 for use in attic and crawl space applications. TABLE 1—PRODUCT TYPES PRODUCT NAME THICKNESS (in.) DENSITY (pcf) R-VALUE PRODUCT DESCRIPTION GreenGuard N14 1 3.3 1.0 Perforated extruded polystyrene foam. GreenGuard S14 1 3.3 1.0 Extruded polystyrene foam core with a clear, perforated, flexible plastic facer on one side. GreenGuard NP14 1 3.3 1.0 Multilayered, perforated extruded polystyrene foam. GreenGuard P14 1 3.3 1.0 Extruded polystyrene foam core with clear, perforated plastic facers on both sides. GreenGuard XP14 1 3.3 1.0 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides and a “cut & fold” hinge design. GreenGuard PLYFOLD Y250 1 3.3 1.0 Extruded polystyrene foam core with clear, perforated plastic facers on both sides. GreenGuard FP14 1 3.7 1.0 Extruded polystyrene foam core with clear, perforated plastic facers on both sides with an additional perforated, metallized facer on one side. GreenGuard XFP14 1 3.7 1.0 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides with an additional perforated, metallized facer on one side. Product has a “cut & fold” hinge design. GreenGuard BACKER-PRO 1 4.7 1.0 Extruded polystyrene foam that is contoured. GreenGuard DC14 1 4.7 1.0 Extruded polystyrene foam that is contoured. GreenGuard PB4 1 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides. /4 /4 /4 /4 /4 /4 /4 /4 /4 /4 /4 3.7 ESR-2136 | Most Widely Accepted and Trusted Page 4 of 4 TABLE 1—PRODUCT TYPES (Continued) GreenGuard PLYGOOD PG28 1 3.7 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides. GreenGuard PLYGOOD PGF28 1 4.2 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides with an additional nonperforated metallized facer on one side. GreenGuard CB4 1 /4 3.7 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides with an additional white, nonperforated facer on the nonprinted side. 5 /16 2.6 1.0 Multilayered, nonperforated extruded polystyrene foam. 5 3.6 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides. 5 /16 3.6 1.0 Extruded polystyrene foam core with a clear, nonperforated plastic facer on one side and a reinforcing scrim on the printed side. GreenGuard NP38 3 2.6 1.5 Multilayered, perforated extruded polystyrene foam. GreenGuard NPG38 3 2.6 1.5 Multilayered, perforated extruded polystyrene foam. GreenGuard P38 3 3.2 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides. Product has a “cut & fold” hinge design. GreenGuard XP38 3 3.2 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides, printed with grid lines. Product has a “cut & fold” hinge design. GreenGaurd Y375 3 3.2 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides. Product has a “cut & fold” hinge design. GreenGuard FP38 3 3.4 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides with an additional perforated, metallized facer on one side. Product has a “cut & fold” hinge design. GreenGuard XFP38 3 3.4 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides with an additional perforated, metallized facer on one side (nonreflective side is printed with grid lines. Product has a “cut & fold” hinge design. GreenGuard PB6 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides. Product has a “cut & fold” hinge design. GreenGuard PB6W 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional white, nonperforated facer on one side. Product has a “cut & fold” hinge design. GreenGuard PB6 PLUS 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional clear, nonperforated facer on both sides. Product has a “cut & fold” hinge design. GreenGuard PB6FA 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional white, nonperforated facer on one side. Product has a “creased” hinge design. GreenGuard PB6FA 90/180 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional white, polyolefin scrim facer on one or both sides. GreenGuard PLYGOOD PGF38 3 3.5 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional nonperforated, metallized facer on one side. 3 /8 3.6 1.5 Extruded polystyrene foam core with a clear, nonperforated plastic facer on one side and a reinforcing scrim on the printed side. 7 /16 3.2 1.8 Extruded polystyrene foam core with a clear, nonperforated plastic facer on one side and a reinforcing scrim on the printed side. /4 /4 GreenGuard PLYGOOD NPG3075, NPG308 GreenGuard PLYGOOD PG3075, PG308 /16 GreenGuard PGWZ WZPG3075, WZPG308 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 GreenGuard PLYGOOD Ultra PGU38, PGU39 GreenGuard PLYGOOD Ultra PGU48, PGU49 GreenGuard CM 1 3 2.0 3.0 - 3.8 Extruded polystyrene insulation board. GreenGuard SL 1 3 2.0 3.0 - 3.8 Extruded polystyrene insulation board with shiplap edges. GreenGuard CMX 1 3 2.0 3.0 - 3.8 Extruded polystyrene insulation board with a clear plastic facer on both side. GreenGuard SLX 1 3 2.0 3.0 - 3.8 /2 - /4 /2 - /4 /2 - /4 /2 - /4 3 2 Extruded polystyrene insulation board with a clear plastic facer on both sides, and shiplap edges. 2 For SI: 1 inch = 25.4 mm, 1 pcf = 16.02 kg/m , R-value: 1°F·ft ·hr/Btu = 0.176 m ·K/W. ® GreenGuard insulation boards are also sold under the Alside Platinum Series™ name. ICC-ES VAR Environmental Report VAR-1036 Issued November 1, 2012 This report is subject to renewal November 1, 2013. www.icc-es.org/ep | 800-423-6587 | (562) 699-0543 DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation Section: 07 25 00—Water-Resistive Barriers Section: 07 27 00—Air Barriers REPORT HOLDER: PACTIV BUILDING PRODUCTS 2100 RIVEREDGE PARKWAY, SUITE 175 ATLANTA, GEORGIA 30328 (800) 241-4402 www.green-guard.com A Subsidiary of the International Code Council ® 2012 International Green Construction Code™ (IgCC) (see Table 4 for details) International Green Construction Code™, Public Version 2.0 (IgCC PV2.0) (see Table 5 for details) 2010 California Green Building Standards Code™ (CALGreen) (see Table 6 for details) ANSI/ASHRAE/USGBC/IES Standard 189.1-2009 – Standard for the Design of High-Performance Buildings (Except Low-Rise Residential Buildings) (see Table 7 for details) 2008 National Green Building Standard™ (ICC 700) (see Table 8 for details) ADDITIONAL LISTEES: LEED for Homes 2008 (see Table 9 for details) GEORGIA-PACIFIC WOOD PRODUCTS, LLC 55 PARK PLACE, 17TH FLOOR ATLANTA, GEORGIA 30303 ANSI/GBI 01-2010 – Green Building Assessment Protocol for Commercial Buildings (see Table 10 for details) LOWES 1000 LOWES BOULEVARD MOORESVILLE, NORTH CAROLINA 28117 EVALUATION SUBJECT: ® GREENGUARD VALUE WRAP BUILDING WRAP GREENGUARD® CLASSIC WRAP BUILDING WRAP GREENGUARD® ULTRA WRAP BUILDING WRAP GREENGUARD® RAINDROP BUILDING WRAP GREENGUARD® MAX BUILDING WRAP ® GREENGUARD C500 BUILDING WRAP GREENGUARD® C2000 BUILDING WRAP GREENGUARD® FANFOLD AND INSULATIVE FOAM BOARDS GREENGUARD® AND GREENGUARD® RCY EXTRUDED POLYSTYRENE INSULATION BOARDS ALSIDE PLATINUM SERIES™ INSULATION ADDITIONAL LISTEE PRODUCT NAMES (BUILDING WRAPS): GEORGIA-PACIFIC WOOD PRODUCTS, LLC: Georgia-Pacific Nautilus™ (refer to Section 3.1) 2.0 USES The following products have been evaluated for use as water-resistive barriers meeting the requirements of International Building Code® (IBC) Sections 1404.2 and ® 2510.6 and International Residential Code (IRC) Section 703 when installed in accordance with ICC-ES report ESR-2906: • GreenGuard® Value Wrap Building Wrap • GreenGuard® Classic Wrap Building Wrap • GreenGuard® Ultra Wrap Building Wrap ® • GreenGuard RainDrop Building Wrap ® • GreenGuard MAX Building Wrap • GreenGuard® C500 Building Wrap ® • GreenGuard C2000 Building Wrap The following products have been evaluated for use as an air barrier material meeting the requirements of IRC Section N1102.4.1 and International Energy Conservation Code® (IECC) Sections 402.4 and 502.4 when installed in accordance with ICC-ES report ESR-2906: • GreenGuard® Ultra Wrap Building Wrap ® • GreenGuard RainDrop Building Wrap LOWES: Lowes Housewrap (refer to Section 3.2) • GreenGuard® MAX Building Wrap 1.0 EVALUATION SCOPE Compliance eligibility with the applicable sections of the following codes, standards and green building rating systems: ® • GreenGuard C2000 Building Wrap ® • GreenGuard C500 Building Wrap The following products are used as nonstructural insulation and as alternatives to the water-resistive barrier requirements of IBC Sections 1404.2 and 2510.6 and IRC ICC-ES Verification of Attributes Reports are issued under the ICC-ES VAR Environmental Program. These reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2012 Page 1 of 5 VAR-1036 | Most Widely Accepted and Trusted Section R703, when installed on exterior walls as described in ICC-ES evaluation report ESR-2136: • GreenGuard® Fanfold and Insulative Foam Boards • Alside Platinum Series™ Insulation The following products are used as nonstructural insulation in wall assemblies, in ceiling/floor assemblies, in door cavities, and at the perimeter of foundations and basements (see ICC-ES ESR-2912 for specific ® ® applications): GreenGuard and GreenGuard RCY extruded polystyrene insulation boards. 3.0 DESCRIPTION ® 3.1 GreenGuard Building Wraps: ® Value Wrap Building Wrap: 3.1.1 GreenGuard ® GreenGuard Value Wrap Building Wrap is a cross-woven, micro-perforated polyolefin material with a polyolefin coating. The wrap is 0.008 inch (0.2 mm) thick, has an 2 average weight of 1.9 ounces per square yard (64 g/m ) and is produced in rolls of varying sizes. GreenGuard® Value Wrap Building Wrap is also sold under the name TM Georgia-Pacific Nautilus . This name applies whenever ® GreenGuard Value Wrap Building Wrap is referenced in this report. ® 3.1.2 GreenGuard Classic Wrap Building Wrap: ® GreenGuard Classic Wrap Building Wrap is a crosswoven, micro-perforated polyolefin material with a polyolefin coating. The wrap is 0.008 inch (0.2 mm) thick, has an average weight of 2.2 ounces per square yard 2 (73 g/m ) and is produced in rolls of varying sizes. GreenGuard® Classic Wrap Building Wrap is also sold under the name Lowe’s Housewrap. This name applies whenever GreenGuard® Classic Wrap Building Wrap is referenced in this report. ® Ultra Wrap Building Wrap: 3.1.3 GreenGuard GreenGuard® Ultra Wrap Building Wrap is a nonwoven, nonperforated material with a vapor-permeable polyolefin coating. The wrap is 0.008 inch (0.2 mm) thick, has an average weight of 2.0 ounces per square yard (68 g/m2) and is produced in rolls of varying sizes. 3.1.4 GreenGuard® RainDrop Building Wrap: ® GreenGuard RainDrop Building Wrap is a cross-woven, nonperforated polyolefin material with a vapor-permeable polyolefin coating. The wrap is 0.018 inch (0.46 mm) thick, has an average weight of 2.4 ounces per square yard 2 (78 g/m ) and is produced in rolls of varying sizes. ® ® 3.1.5 GreenGuard MAX Building Wrap: GreenGuard MAX Building Wrap is a cross-woven, nonperforated polyolefin material with a vapor-permeable polyolefin coating. The wrap is 0.018 inch (46 mm) thick, has an 2 average weight of 2.2 ounces per square yard (75 g/m ) and is produced in rolls of varying sizes. 3.1.6 GreenGuard® C500 Building Wrap: GreenGuard® C500 Building Wrap is a cross-woven, nonperforated polyolefin material with a vapor-permeable polyolefin coating. The wrap is 0.010 inch (0.26 mm) thick, has an average weight of 3.6 ounces per square yard (122 g/m2) and is produced in rolls of varying sizes. ® C2000 Building Wrap: 3.1.7 GreenGuard GreenGuard® C2000 Building Wrap is a spun-bonded, vapor-permeable polyolefin material, 0.024 inch (0.60 mm) thick, and with an average weight of 5.1 ounces per square 2 yard (173 g/m ). The wrap is produced in rolls of varying sizes. 3.2 Foam Boards: ® The GreenGuard Fanfold and Insulative Foam Boards consist of an extruded polystyrene foam plastic core, with Page 2 of 5 or without various combinations of facers, and are available in semirigid boards or “fanfolded” bundles. They range from 1/4 to 3/4 inch (6.4 to 19.1 mm) thick. Table 2 contains detailed product descriptions for the various ® products recognized in this report. GreenGuard GreenGuard® products are available in 4-foot-wide (1.2 m) ® boards in lengths up to 50 feet (15.2 m). The GreenGuard Fanfold and Insulative Foam Boards are also sold under the Alside Platinum Series™ Insulation name. 3.3 Joint-sealing Tapes: Joint-sealing tapes are used in conjunction with the insulation boards to seal joints between edges of the boards, when installation is as an alternative waterresistive barrier. ® ® 3.3.1 GreenGuard Butyl Flashing: GreenGuard Butyl Flashing is a polyolefin-faced self-adhering flashing tape with a butyl adhesive. The tape is nominally 0.020 inch thick (0.51 mm) and is produced in minimum 4-inch-wide (100 mm) rolls. ® SuperStretch™: GreenGuard® 3.3.2 GreenGuard SuperStretch™ tape is an EPDM rubber-faced, selfadhering flashing tape with a butyl adhesive. The tape is nominally 0.052 inch thick (1.32 mm) and is produced in minimum 7-inch-wide (178 mm) rolls. ® 3.3.3 GreenGuard Contractor Sheathing/Housewrap Custom: GreenGuard® Contractor Sheathing/Housewrap Custom tape is a polypropylene-faced self-adhering flashing tape with an acrylic adhesive. The tape is nominally 0.002 inch thick (0.051 mm) and is produced in 21/2-inch-wide (64 mm) rolls. 3.4 Insulation Boards: ® ® The GreenGuard and GreenGuard RCY Extruded Polystyrene Insulation Boards are extruded polystyrene foam plastic insulation boards complying with ASTM C578. The insulation boards are available in thicknesses of 1, 11/2 and 2 inches (25.4, 38 and 51 mm) and are produced in the types and densities specified in Table 3. 4.0 CONDITIONS 4.1 Code Compliance: See the ICC-ES reports listed in Table 1 for compliance with applicable IBC, IRC and/or IECC code requirements. 4.2 Codes, Standards and Green Rating Systems Eligibility: The information presented in Tables 4 through 10 of this report provides a matrix of areas of evaluation and corresponding limitations and/or additional project-specific requirements, and offers benefit to individuals who are assessing eligibility for compliance, credits or points. The final interpretation of the specific requirements of the respective codes, standards and/or green building rating systems rests with the Authority Having Jurisdiction, the developer of the specific standard of rating system, as applicable. Compliance with the items noted as “Verified Attribute” is subject to any conditions noted in Tables 4 though 10. The user is advised of the project-specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. Rating systems or standards may provide supplemental information as guidance. 5.0 BASIS OF EVALUATION The information in this report, including the “Verified Attribute,” is based upon the following supporting documentation: VAR-1036 | Most Widely Accepted and Trusted Page 3 of 5 ICC-ES ESR-2906 [Evaluation applies to 2012 IgCC Section 605.1.2.1; IGCC PV2.0 Section 606.1.2; ASHRAE 189.1 Sections 7.4.2.10; ICC 700 Section 703.2.1; LEED Homes EA Credit 3; and ANSI/GBI ® Section 10.8.1 for GreenGuard Ultra Wrap Building ® Wrap, GreenGuard RainDrop Building Wrap, ® ® GreenGuard MAX Building Wrap, GreenGuard C500 Building Wrap, GreenGuard® C2000 Building Wrap only] ICC-ES ESR-2136 and ESR-2906 [Evaluation applies to ICC 700 Section 602.9 for all products listed] Report of testing in accordance with ASTM E 1677 [Evaluation applies to CALGreen Section A4.206.1 for GreenGuard® Ultra Wrap Building Wrap, GreenGuard® ® RainDrop Building Wrap, GreenGuard MAX Building Wrap, GreenGuard® C500 Building Wrap, GreenGuard® C2000 Building Wrap only] ICC-ES ESR-2136 and ESR-2912 [Evaluation applies to ICC 700 Sections 701.4.3, 703.1 and 703.2 for all products listed] 6.0 IDENTIFICATION ® ® GreenGuard Value Wrap Building Wrap, GreenGuard ® Classic Wrap Building Wrap, GreenGuard Ultra Wrap Building Wrap, GreenGuard® Raindrop Building Wrap, GreenGuard® Max Building Wrap, GreenGuard® C500 ® Building Wrap and GreenGuard C2000 Building Wrap are identified by a label on each roll of membrane, bearing the report holder’s name (Pactiv) and address, the product name, and the VAR number (VAR-1036) ® GreenGuard Fanfold and Insulative Foam Boards and Alside Platinum Series™ Insulation are identified by the report holder's name and address, the product name and the VAR number (VAR-1036). ® The GreenGuard Butyl and SuperStretch Flashings are identified by the report holder's name, the product name and the VAR number (VAR-1036). The GreenGuard® Contractor Sheathing/Housewrap Tape is identified by the report holder's name, the product name and the VAR number (VAR-1036). GreenGuard® and GreenGuard® RCY Extruded Polystyrene Insulation Boards are identified by the report holder's name and address, the product name and the VAR number (VAR-1036). TABLE 1—EVALUATION REPORTS FOR PACTIV PRODUCTS PRODUCT REPORT NUMBER ® GreenGuard Fanfold and Insulative Foam Boards and Alside Platinum Series™ Insulation ESR-2136 ® GreenGuard Value Wrap Building Wrap ® GreenGuard Classic Wrap Building Wrap ® GreenGuard Ultra Wrap Building Wrap ® GreenGuard RainDrop Building Wrap ® GreenGuard MAX Building Wrap ® GreenGuard C500 Building Wrap ® GreenGuard C2000 Building Wrap ® ESR-2906 ® GreenGuard and GreenGuard RCY Extruded Polystyrene Insulation Boards ESR-2912 TABLE 2—PACTIV INSULATION PRODUCTS (ESR-2136) PRODUCT NAME GreenGuard N14 THICKNESS (in.) 1 /4 DENSITY (pcf) R-VALUE 3.3 1.0 Perforated extruded polystyrene foam. 3.3 1.0 Extruded polystyrene foam core with a clear, perforated, flexible plastic facer on one side. 1 /4 GreenGuard S14 PRODUCT DESCRIPTION GreenGuard NP14 1 3.3 1.0 Multilayered, perforated extruded polystyrene foam. GreenGuard P14 1 3.3 1.0 Extruded polystyrene foam core with clear, perforated plastic facers on both sides. 3.3 1.0 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides and a “cut & fold” hinge design. 3.3 1.0 Extruded polystyrene foam core with clear, perforated plastic facers on both sides. 3.7 1.0 Extruded polystyrene foam core with clear, perforated plastic facers on both sides with an additional perforated, metallized facer on one side. 3.7 1.0 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides with an additional perforated, metallized facer on one side. Product has a “cut & fold” hinge design. Extruded polystyrene foam that is contoured. /4 /4 1 /4 GreenGuard XP14 GreenGuard PLYFOLD Y250 1 /4 1 /4 GreenGuard FP14 1 /4 GreenGuard XFP14 GreenGuard BACKER-PRO 1 4.7 1.0 GreenGuard DC14 1 4.7 1.0 Extruded polystyrene foam that is contoured. 3.7 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides. /4 /4 1 /4 GreenGuard PB4 GreenGuard PLYGOOD PG28 1 3.7 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides. GreenGuard PLYGOOD PGF28 1 4.2 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides with an additional nonperforated metallized facer on one side. GreenGuard CB4 1 /4 3.7 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides with an additional white, nonperforated facer on the nonprinted side. 5 /16 2.6 1.0 Multilayered, nonperforated extruded polystyrene foam. GreenGuard PLYGOOD NPG3075, NPG308 /4 /4 VAR-1036 | Most Widely Accepted and Trusted Page 4 of 5 TABLE 2—PACTIV INSULATION PRODUCTS (ESR-2136) – (Continued) PRODUCT NAME THICKNESS (in.) DENSITY (pcf) R-VALUE 5 3.6 1.0 Extruded polystyrene foam core with clear, nonperforated plastic facers on both sides. 5 /16 3.6 1.0 Extruded polystyrene foam core with a clear, nonperforated plastic facer on one side and a reinforcing scrim on the printed side. GreenGuard NP38 3 2.6 1.5 Multilayered, perforated extruded polystyrene foam. GreenGuard NPG38 3 2.6 1.5 Multilayered, perforated extruded polystyrene foam. GreenGuard P38 3 3.2 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides. Product has a “cut & fold” hinge design. GreenGuard XP38 3 3.2 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides, printed with grid lines. Product has a “cut & fold” hinge design. GreenGaurd Y375 3 3.2 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides. Product has a “cut & fold” hinge design. GreenGuard FP38 3 3.4 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides with an additional perforated, metallized facer on one side. Product has a “cut & fold” hinge design. GreenGuard XFP38 3 3.4 1.5 Extruded polystyrene foam core with clear, perforated, flexible plastic facers on both sides with an additional perforated, metallized facer on one side (nonreflective side is printed with grid lines. Product has a “cut & fold” hinge design. GreenGuard PB6 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides. Product has a “cut & fold” hinge design. GreenGuard PB6W 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional white, nonperforated facer on one side. Product has a “cut & fold” hinge design. GreenGuard PB6 PLUS 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional clear, nonperforated facer on both sides. Product has a “cut & fold” hinge design. GreenGuard PB6FA 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional white, nonperforated facer on one side. Product has a “cut & fold” hinge design. GreenGuard PB6FA 90/180 3 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional white, polyolefin scrim facer on one or both sides. GreenGuard PLYGOOD PGF38 3 3.5 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides with an additional nonperforated, metallized facer on one side. 3 /8 3.6 1.5 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides and a reinforcing scrim on the printed side. 7 /16 3.2 1.8 Extruded polystyrene foam core with clear, nonperforated, flexible plastic facers on both sides and a reinforcing scrim on the printed side. GreenGuard PLYGOOD PG3075, PG308 /16 GreenGuard PGWZ WZPG3075, WZPG308 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 /8 GreenGuard PLYGOOD Ultra PGU38, PGU39 GreenGuard PLYGOOD Ultra PGU48, PGU49 PRODUCT DESCRIPTION GreenGuard CM 1 3 2.0 3.0 – 3.8 Extruded polystyrene insulation board. GreenGuard SL 1 3 2.0 3.0 – 3.8 Extruded polystyrene insulation board with shiplap edges. GreenGuard CMX 1 3 2.0 3.0 – 3.8 Extruded polystyrene insulation board with clear plastic facer on both sides. GreenGuard SLX 1 3 2.0 3.0 – 3.8 /2 – / 4 /2 – / 4 /2 – / 4 /2 – / 4 3 2 Extruded polystyrene insulation board with clear plastic facer on both sides, and shiplap edges. 2 For SI: 1 inch = 25.4 mm, 1 pcf = 16.02 kg/m , R-value: 1°F·ft ·hr/Btu = 0.176 m ·K/W. ® GreenGuard insulation boards are also sold under the Alside Platinum Series™ name. TABLE 3—PACTIV INSULATION PRODUCTS (ESR-2912) XPS CLASSIFICATION MINIMUM DENSITY (pcf) MINIMUM R-VALUE (per inch of thickness) ASTM Type IV 1.55 5.0 ASTM Type VI 1.8 3 2 5.0 2 For SI: 1 inch = 25.4 mm, 1 pcf = 16.02 kg/m , R-value: 1°F·ft ·hr/Btu = 0.176 m ·K/W. VAR-1036 | Most Widely Accepted and Trusted Page 5 of 5 TABLES 4 THROUGH 10 SECTION NUMBER SECTION INTENT POSSIBLE POINTS CONDITIONS OF USE TO QUALIFY FOR POINTS FINDING TABLE 4—SUMMARY OF AREA OF ELIGIBILITY WITH THE 2012 INTERNATIONAL GREEN CONSTRUCTION CODE 605.1.2.1 Air leakage mitigation measures shall be provided in accordance with this section. 606.1.2 Air leakage mitigation measures shall be provided in accordance with this section. N/A Verify that the air barrier material has been installed properly and tested to meet the requirements as set forth in IgCC Section 605.1.2.2 ○1 TABLE 5—SUMMARY OF AREA OF ELIGIBILITY WITH THE INTERNATIONAL GREEN CONSTRUCTION CODE PV2.0 N/A Verify that the air barrier material has been installed properly and tested to meet the requirements as set forth in IgCC Section 606.1.2.2 ○1 TABLE 6—SUMMARY OF AREA OF ELIGIBILITY WITH 2010 CALGREEN A4.206.1 Voluntary measure Air sealing package Verify that the air barrier material has been installed properly and tested to meet the requirements as set forth in California Energy Code (test method specified is ASTM E1677) ○1 7.4.2.10 Prescriptive TABLE 7—SUMMARY OF AREA OF ELIGIBILITY WITH ASHRAE 189.0-2009 Continuous air barrier The building envelope shall be constructed with a continuous air barrier complying with Normative Appendix B. Pactiv building wraps listed in ESR2906 meet the requirements of B2 for air barrier materials ●1 TABLE 8—SUMMARY OF AREAS OF ELIGIBILITY WITH THE NATIONAL GREEN BUILDING STANDARD (ICC 700-2008) Water-resistive barrier N/A Install a water-resistive barrier and/or drainage plan system behind the exterior veneer and/or siding ● 701.4.3 Insulation and air sealing N/A Insulation is installed in accordance with the manufacturer's instructions or local code, as applicable ●2 703.1.1 Building envelope (insulation) Per Table 703.1.1 Building thermal envelope UA is less than required by the International Energy Conservation Code. Pactiv insulations may be used to comply with this requirement ○2 703.1.2 Building envelope (insulation) Per Table 703.1.2 Insulation is graded by a third party and is in accordance with Section 703.1.2 through 703.1.2.4, as applicable. Pactiv insulations may be used to comply with this requirement ○2 3 15 max Insulation and/or air sealing is installed in accordance with the following, as applicable: (1) third-party verification performed 15 pts, No third-party verification performed 3 pts ○ 602.9 703.2.1 Insulation and/or air sealing TABLE 9—SUMMARY OF AREA OF ELIGIBILITY WITH USGBC'S LEED FOR HOMES 2008 EA 3 Air infiltration 3 max To earn 2 or 3 points meet the leakage requirements shown in Table 17 of the rating system, as applicable, when tested and verified by a third-party ○1 TABLE 10—SUMMARY OF AREA OF ELIGIBILITY WITH ANSI/GBI 01-2010 Earn 3 points for Installation of a continuous air barrier as set forth in Section 10.8.1.1 of the standard 10.8.1 3 6 max Air barrier ○ = Eligible attribute ● = Verified attribute ●1 Earn 3 points for use of an air barrier material tested in accordance with ASTM E2178 where the air permeability of individual materials did not 2 2 exceed 0.02 L/s·m under a pressure differential of 75 Pa (0.004 cfm/ft ) 2 under a pressure differential of 0.3 in. water (1.57 lb/ft ) N/A = Not applicable (i.e. this is a minimum or mandatory requirement and points/credits are not applicable) 1 ® ® ® ® Applicable to GreenGuard Ultra Wrap Building Wrap, GreenGuard RainDrop Building Wrap, GreenGuard MAX Building Wrap, GreenGuard C500 ® Building Wrap, GreenGuard C2000 Building Wrap only. 2 ® ® ® Applicable to GreenGuard Fanfold and Insulative Foam Boards and GreenGuard and GreenGuard RCY Extruded Polystyrene Insulation Boards only.
© Copyright 2024 ExpyDoc