Download Ess Ordering Information

ORDERING INFORMATION
RM 2 2 1 1
XXXX
X
CA
11
B XX
XX
Accesories
JB: Junction Box
FD: Flag Disk
LB: `L’ Bracket
Basic Model
LO: Linear Output
TB: Terminal Box
2: Heavy Duty Outdoor
P: Plastic DIN Rail Indoor
E: Industrial Grade Outdoor
D: Direct PLC Application
Probe Size
12/18/30/50/80/mm Dia x ........length
120: Anemometer cups 120 diameter
100: Extension Stand 100mm Roller
03: Belt Loading Monitor 100mm roller
Speed Setting Model
0: No Setting
1: Trimpot
2: knob
4: Not Used
5: Not Used
6: Key-Pad
Probe Enclosure
B: Brass Tube Non Flush
S: SS Tube
A: Plastic Tube
PE: Protective Enclosure
AN: Anemometer cup
ES: Extension Stand (Cast Al)
BLM: Belt Loading Monitor (Cast Al)
Circuit Principle
1: Micro controller
2: Not Applicable
3: Discrete Component AC
4: Digital Anemometer
5: Discrete Component DC
6: Micro-Controller with Display
7: Thumbwheel
Output Contact
11: 1NO + 1NC
22: 2NO + 2 NC
1C: 1 C/O
2C: 2 C/O
Duty
0: Only Speed Indicator
1: Under Speed
2: Over Speed
3: Under-Over Speed
4: Belt Load Monitor / Output Logic
5: Under Speed & Belt
Sequential Starting
6: Slip Monitor
7: Under with EXT STAND
Monitoring Unit Enclosure Details
Time Delay Feature / Output Logic
Nil: Standard Model
TD: With ITD
NTD: With NTD
NITD: With ITD & NTD
NO: Static NO
NC: Static NC
CA : Cast Aluminium
IP-65
CI : Cast Iron
IP-65
PC : Polycarbonate
IP-30
PL : Ind. Plastic
FPA : Cast Aluminium FLP
IP-65
IP-65
FPI : Cast Aluminium FLP
IP-65
B : Brass Tube
SS : Stainless Steel
MS : Mild Steel
IP-67
IP-67
IP-67
Range Selector Switch
Nil: Calibrated dial in 1:10 Ratio
S-2: Two Position Selector Switch
S-3: Three Position Selector Switch
Example
The model with industrial CA grade enclosure and having under-speed duty and initial time delay with standard M30 sensor probe is as given below
RM E211-TD-CA-11-B30
Special Application
Speed switches for specific applications as below are
available. Please refer works for more details.
Special models are available for over
speed safety of hoist crane.
I) Crane Application :
Model with specific operation of output
relay for plugging duty application. The speed switch senses
the speed switch of the rotating object near zero speed and
switches of the reverse sequence supply connected to the
motor.
ii) Plugging Duty :
Special controller unit to take
inputs from multiple no. of probes are available for
monitoring multiple shaft machine. The unit has got a
single output relay which gives a signal if any of the sensors
stops giving pulses.
iii) Cable Winding Machine :
A very high precision (12 bitmicrocontroller) unit for measuring and display speed of a
bullet of high speed projectile launcher. The unit incorporates
a special optical / magnetic type sensor
iv) Defense Applications :