PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Link Engineering Company 401 Southfield Road, Dearborn, MI 48120 13840 Elmira Street, Detroit, MI 48227 (Hereinafter called the Organization) and hereby declares that Organization is accredited in accordance with the recognized International Standard: ISO/IEC 17025:2005 This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (as outlined by the joint ISO-ILAC-IAF Communiqué dated January 2009): Testing of Automotive and Heavy Truck Break Components, Wheel Components, Fluids, Friction Materials, and Vehicle Testing including Chemical Composition for Automotive Products (As detailed in the supplement) Accreditation claims for such testing and/or calibration services shall only be made from addresses referenced within this certificate. This Accreditation is granted subject to the system rules governing the Accreditation referred to above, and the Organization hereby covenants with the Accreditation body’s duty to observe and comply with the said rules. For PJLA: Tracy Szerszen President/Operations Manager Perry Johnson Laboratory Accreditation, Inc. (PJLA) 755 W. Big Beaver, Suite 1325 Troy, Michigan 48084 Initial Accreditation Date: Issue Date: Expiration Date: August 27, 2002 October 21, 2014 January 31, 2017 Accreditation No.: Certificate No.: 59264 L14-282 The validity of this certificate is maintained through ongoing assessments based on a continuous accreditation cycle. The validity of this certificate should be confirmed through the PJLA website: www.pjlabs.com Page 1 of 5 Certificate of Accreditation: Supplement Link Engineering Company 401 Southfield Road, Dearborn, MI 48120 13840 Elmira Street, Detroit, MI 48120 Contact Name: Ann Helms Phone: 313-933-4900 Accreditation is granted to the facilities to perform the following testing: 401 Southfield Road, Dearborn, MI 48120 & 13840 Elmira Street, Detroit, MI 48120 FIELD OF TEST Mechanical F ITEMS, MATERIALS OR PRODUCTS TESTED Friction Materials SPECIFIC TESTS OR PROPERTIES MEASURED Friction/Wear Compressibility Swell & Growth Internal Shear Shear Strength Friction Materials and Components for Hydraulic Brakes Noise Wear Friction Effectiveness/Performance/Wear Friction Materials and Components for Air Brakes Suspension and Brake Corner Components Strength and Fatigue Friction Effectiveness/Performance/Wear Hydraulic Brake Systems Stopping Distance/Balance/Fade SPECIFICATION, STANDARD METHOD OR TECHNIQUE USED SAE J661 VESC-V3 SAE J2468 ISO 6310 ABNT NBR 9301 ECE R90-02 GMW 15334 SAE J160 ABNT NBR 5505 ISO 6311 ISO 6312 ABNT NBR 5537 SAE J840 ECE R90-02 SAE J2521 JASO C427 SAE J2707 SAE J2522 SAE J2784 SAE J2684 SAE J2928 ISO 26867 JASO C406 JASO C407 ECE R90-2 JASO C441 JASO C448 SAE J1713 RP 628 TP-121D SAE J2115 FMVSS 105 FMVSS 135 ECE R90-02 JIS D 2603 SAE J101 Hydraulic Brake Systems Performance Hydraulic Wheel Cylinders for Performance Automotive Drum Brakes Wheel Nut Seat System SAE J2316 Master Cylinder Assemblies Performance and Durability SAE J1153 Hub-bearing Assemblies and Impact SAE J175 Wheels Issue: 10/14 This supplement is in conjunction with certificate #L14-282 RANGE (WHERE APPROPRIATE) AND DETECTION LIMIT 0.4 % of F.S.R. 0.85 % F.S.R. 0.72 % F.S.R. 0.13 % F.S.R. 0.29 % F.S.R. 0.3 % F.S.R. 0.63 % F.S.R. 0.63 % F.S.R. 0.52 % F.S.R. 0.33 % F.S.R. 0.63 % F.S.R. Page 2 of 5 Certificate of Accreditation: Supplement Link Engineering Company 401 Southfield Road, Dearborn, MI 48120 13840 Elmira Street, Detroit, MI 48120 Contact Name: Ann Helms Phone: 313-933-4900 Accreditation is granted to the facilities to perform the following testing: 401 Southfield Road, Dearborn, MI 48120 & 13840 Elmira Street, Detroit, MI 48120 FIELD OF TEST Mechanical F ITEMS, MATERIALS OR PRODUCTS TESTED Hub-bearing Assemblies and Wheels SPECIFIC TESTS OR PROPERTIES MEASURED Cornering Fatigue Radial Fatigue Hub-bearing Assemblies/Wheels Biaxial Fatigue Issue: 10/14 SPECIFICATION, STANDARD METHOD OR TECHNIQUE USED SAE J328 SAE J1095 SAE J2530 SAE J328 SAE J175 SAE J328 SAE J1095 SAE J2530 SAE J2562 SAE J2562 RANGE (WHERE APPROPRIATE) AND DETECTION LIMIT 0.63 % F.S.R. 0.8 % F.S.R. This supplement is in conjunction with certificate #L14-282 Page 3 of 5 Certificate of Accreditation: Supplement Link Engineering Company 401 Southfield Road, Dearborn, MI 48120 13840 Elmira Street, Detroit, MI 48120 Contact Name: Ann Helms Phone: 313-933-4900 Accreditation is granted to the facilities to perform the following testing: 401 Southfield Road, Dearborn, MI 48120 FIELD OF TEST Mechanical F ITEMS, MATERIALS OR PRODUCTS TESTED Friction Materials/ Brake Hardware/ Full Vehicle Brakes/Tires/ Wheels/Full Vehicle Full Vehicle Issue: 10/14 SPECIFIC TESTS OR PROPERTIES MEASURED Brake Systems Durability City Traffic- Noise/Wear Suburban Traffic Structural Public Road Fuel Economy Coast-Down Fuel Consumption NVH Vehicle Testing Interior/ Exterior Noise Studies Pass by Noise Thermal HVAC, Death Valley Cooling Systems Cold Chamber Wheel and Tire Tire Blow-Out Structural Integrity Customer Specifications SPECIFICATION, STANDARD METHOD OR TECHNIQUE USED FMVSS-105 FMVSS-135 FMVSS-122 FMVSS-126 ECE-R13H ECE-R13 ECE R90-2 Customer Specifications Trailer Tow Thermal Capacity High Speed Fade AMS Fade Test Fluid Boil Vacuum Boosted Performance Customer Specification City Traffic Suburban Traffic Structural Durability SAE J2263 SAE J1321 SAE J986 RANGE (WHERE APPROPRIATE) AND DETECTION LIMIT Instrument Specifications Stopping Distance: Detection: y= (1.33 x 10-3 + 4.66 x 10-2) Pedal Force: 3.1 N to 2 224 N (0.7 lbf to 500 lbf) Temperature: 2° C to 1 371° C Deceleration 0.01 G to 2.0 G Pedal Travel: 0.8 mm to 508 mm (0.32 in to 20 in) Pressure: 5.31 Pa to 34 470 kPa (0.78 psi to 5 000 psi) Steering Wheel Torque: 0.5 Nm to 135 Nm (0.4 ft·lbs to 100 ft·lbs) Lateral Drift Limit: y= (3.938 x 10-5 + 3.122 x 10-5 )m Wheel Break Torque: 8 Nm to 8 135 Nm (6 ft·lbs to 6 000 ft·lbs) Customer Specification FMVSS 110 Directly Related to the Above Listed Methodologies This supplement is in conjunction with certificate #L14-282 Page 4 of 5 Certificate of Accreditation: Supplement Link Engineering Company 401 Southfield Road, Dearborn, MI 48120 13840 Elmira Street, Detroit, MI 48120 Contact Name: Ann Helms Phone: 313-933-4900 Accreditation is granted to the facilities to perform the following testing: 401 Southfield Road, Dearborn, MI 48120 FIELD OF TEST ITEMS, MATERIALS OR PRODUCTS TESTED Chemical F Automotive Friction Materials 1. SPECIFIC TESTS OR PROPERTIES MEASURED Chemical Composition SPECIFICATION, STANDARD METHOD OR TECHNIQUE USED SAE J2975: 2013 SAE J2975: 2011 EPA 3051A EPA 6010C EPA 3060A EPA 7196A EPA/600/R-93/116 RANGE (WHERE APPROPRIATE) AND DETECTION LIMIT 0 % to 100 % Detection Limit(s): Cd, Cr, Cu, Hg, and Ni = 0.000 25 % Pb, Sb, and Zn = 0.002 5 % Cr VI = 0.05 % Asbestos = 0.1 % The presence of a superscript F means that the laboratory performs testing of the indicated parameter at its fixed location. Example: Outside Micrometer F would mean that the laboratory performs this testing at its fixed location. Issue: 10/14 This supplement is in conjunction with certificate #L14-282 Page 5 of 5
© Copyright 2024 ExpyDoc