Pressure Spray Set-ups, External Mix, 1/2J Series

Pressure Spray Set-ups, External Mix,
1/2J Series
Features and Benefits
Air Caps
• The dimensions “A”, “B” and “C” are the pattern widths at distances from the nozzle.
• The total distance of spray projection from the nozzle to the maximum dispersal point is represented
by “D”.
• SUE75 and SU380C are pressure set-ups using pressurized liquids.
Flat spray air caps produce
a flat spray pattern.
• In SU380C, the air and liquid mix internally, while in SUE75, they mix externally.
• SU70 is a siphon set-up with the air and siphoned liquid mixing externally.
Fluid cap
Air cap
C
B
A
Flat spray
pattern
9"
(23 cm)
18" (46 cm)
27" (69 cm)
D
8491
gasket
1705 retainer ring
Air Atomizing
nozzles
1705 retainer ring and 8491 gasket must be ordered separately from the spray set-up, but are included in
the standard nozzle assembly. Please contact your sales engineer.
Performance Data
Flat Spray (External Mix)
Spray
Set-up
Spray
Consists of
Set-up
Fluid and
No.
Air Cap
Combination
SUE75
Fluid Cap
250375
+
Air Cap
14356
*At the stated pressure in psi.
Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)*
Spray
Dimensions
Liquid Pressure
3
5
7
10
15
Air
Air
Air
Air
Air
A
gph scfm Air* Liquid*
gph scfm
gph scfm
gph scfm
gph scfm
Press.
Press.
Press.
Press.
Press.
(in.)
30
138
31
40
180
35
138
34
45
40
138
38
45
138 41.5
45
210 41.5
55
252
180 41.5
50
210
45
60
50
180
45
55
210
48
55
180
48
60
180 51.5
–
–
–
60
–
–
–
–
–
38
–
48
80
306
65
252 51.5
85
306
69
70
252
58
90
306
72
210 51.5
75
252
62
95
306
75
65
210
55
80
252
65
100
306
78
70
210
58
85
252
69
–
–
–
35
3
50
5
B
(in.)
C
(in.)
D
(ft.)
8-1/2 14-1/2 20-1/2 19
9
16-1/2 21-1/2 22
55
7
9-1/2 17-1/2
23
23
70
10
9-1/2
18
24
25
90
15
10
19
26
29
Phone 1-800-95-spray, FAX 1-888-95-spray
Visit Our Web Site: www.spray.com, Email: [email protected]
F47
Air Atomizing Nozzles
Pressure Spray Set-ups, External Mix,
1/2J Series
Performance Data
360° Circular Spray
Spray
Set-up
No.
SU380C
Spray
Set-up
Consists of
Fluid and
Air Cap
Combination
Fluid Cap
251376
+
Air Cap
469-6-130160HC
*At the stated pressure in psi.
Liquid Capacity (gallons per hour)* and Air Capacity (standard cubic feet per minute)*
Liquid Pressure
10
20
30
40
60
Air
Air
Air
Air
Air
gph scfm
gph scfm
gph scfm
gph scfm
gph scfm
Press.
Press.
Press.
Press.
Press.
14.0
56.4
12.2
24
104
16.0
36
116
22.4
48
122
27.8
72
128
40.2
16.0
38.4
14.8
26
85.8
18.6
38
98.4
24.8
50
110
29.8
74
116
42.3
44.3
18.0
25.8
16.8
28
72.6
20.3
40
85.2
26.5
52
98.4
31.5
76
108
20
15.6
19.0
30
54.6
22.7
42
73.2
28.9
54
85.8
33.8
78
96.6 46.3
–
–
–
32
42
24.8
44
72
30.9
56
74.4
36
80
85.8 48.3
–
–
–
34
30.6
26.8
46
49.8
32.9
58
66
38.3
82
78.6 50.5
–
–
–
36
24.6
29.3
48
38.4
35
60
55.2
40.1
84
67.8 52.5
–
–
–
38
7.2
31.8
50
30
37.8
62
44.4
42
86
61.2 54.8
–
–
–
–
–
–
–
–
–
64
37.2
44.5
90
48
59
–
–
–
–
–
–
–
–
–
66
20.4
45.8
–
–
–
360° circular spray pattern
Odor control at a compost facility using air atomizing nozzles.
Phone 1-800-95-spray, FAX 1-888-95-spray
Visit Our Web Site: www.spray.com, Email: [email protected]
F48