1 2 3 4 ARCHITECTURAL SYMBOLS N NORTH ARROW LANKENAU MEDICAL OFFICE BUILDING WINDOW REPLACEMENT A Name Elevation ELEVATION (BENCH MARK) X XXXX BUILDING SECTION DETAIL REFERENCE NUMBER SHEET NUMBER X XXXX X LANKENAU HOSPITAL 100 EAST LANCASTER AVENUE WYNNEWOOD, PENNSYLVANIA EXTERIOR ELEVATION DETAIL REFERENCE NUMBER SHEET NUMBER KEYNOTE REFERENCE 3' - 0" DIMENSION STRING TO CENTER LINE OF COLUMN 3' - 0" DIMENSION STRING RUNNING Room Name XXX X.X 0 MAINLINE HEALTH 000 1 ROOM NAME ROOM NUMBER PARTITION TYPE WINDOW NUMBER DOOR NUMBER SCOPE OF WORK 1 REVISION (NUMBER) B FACE BRICK CMU CONCRETE STEEL CONT. FRAMING MEMBER BLOCKING SHIM SPACE GLASS PLYWOOD W CLE CIR D OO BATT INSULATION CAVITY INSULATION GYPSUM WALL BOARD C LA SAND, GROUT OR MORTAR NC AS T 1 A001 ER AV EN U TR AN SF OR ME RY AR D PROJECT SCOPE CODE CONSIDERATIONS: ZONING DISTRICT: MC AN DI IN PARKING GARAGE K EE CR EAST MOB MEDICAL SCIENCE BUILDING SOUTH ANNEX ABBREVIATIONS: @ ABV APC ACT BLW B.O. BOD BTWN C.C. CH CL CSK CMU CAB CLR CW DET. DN DIA DWG. EL ELEC ELEV. EM EP EQ EQUIP ES EW EXIST. F.D. FDC FE F.F. FEC FHC FL F.O. FT GWB GALV. HCW HM HORIZ HP HT. HVAC HW INCL INSUL LAB LP LT MAT. MAX. MECH. MEP MEZZ. M.H. MFR MTL MIN MISC. M.O. MTD. N/A N.I.C. NO. NOM. OH OPG. OPP PLUM. PL. P.S.I. PT. PTD RD REV. RM R.R. SCHED SIM. SQ. SQ.FT. / SF S.S. STD. STL. STRUCT TBD T.O. T.O.C. T.O.S. TYP. UNO VCT VERT. W/ WD WT. AT ABOVE ACOUSTICAL PANEL CEILING ACOUSTICAL CEILING TILE BELOW BOTTOM OF BASIS OF DESIGN BETWEEN CENTER TO CENTER CEILING HEIGHT CENTERLINE COUNTER SUNK CONCRETE MASONRY UNIT CABINET CLEAR COLD WATER DETAIL DOWN DIAMETER DRAWING(S) ELEVATION ELECTRIC(AL) ELEVATOR EMERGENCY POWER ELECTRICAL PANEL EQUAL EQUIPMENT EMERGENCY SHOWER EYE WASH EXISTING FLOOR DRAIN FIRE DEPARTMENT CONNECTION FIRE EXTINGUISHER FINISHED FLOOR FIRE EXTINGUISHER CABINET FIRE HOSE CABINET FLOOR(ING) FACE OF FOOT/FEET GYPSUM WALL BOARD GALVANIZED HOT AND COLD WATER HOLLOW METAL HORIZONTAL HIGH POINT HEIGHT HEATING/ VENTILATING/ AIR CONDITIONING HOT WATER INCLUDING, INCLUDED INSULATION LABORATORY LOW POINT LIGHT MATERIAL(S) MAXIMUM MECHANICAL MECHANICAL/ ELECTRICAL/ PLUMBING MEZZANINE MANHOLE MANUFACTURER METAL MINIMUM MISCELLANEOUS MASONRY OPENING MOUNTED NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL OPPOSITE HAND OPENING OPPOSITE PLUMBING PLATE POUNDS PER SQUARE INCH POINT PAINT(ED) ROOF DRAIN REVISION(S), REVISED ROOM RAILROAD SCHEDULE SIMILAR SQUARE SQUARE FEET STAINLESS STEEL STANDARD STEEL STRUCTURAL TO BE DETERMINED TOP OF TOP OF CONCRETE TOP OF STEEL TYPICAL UNLESS NOTED OTHERWISE VINYL COMPOSITION TILE VERTICAL WITH WOOD WEIGHT E THE PROPOSED PROJECT IS WINDOW REPLACEMENT AND MINOR INTERIOR FINISH REPAIR WEST MOB 5 THERE IS NO CHANGE PROPOSED IN: • LOT AREA • IMPERVIOUS COVERAGE • BUILDING AREA • OPEN SPACE • BUILDING HEIGHT • MEANS OF EGRESS LANKENAU HOSPITAL 100 EAST LANCASTER AVENUE WYNNEWOOD, PA 19096 WEST MOB WINDOW REPLACEMENT DRAWING LIST CS-1 A001 A200 A201 A300 A400 COVER SHEET ARCHITECTURAL SITE PLAN BUILDING ELEVATIONS BUILDING ELEVATIONS PLANS / DETAILS WINDOW DETAILS THERE ARE NO EXTERIOR LIGHTING CHANGES PROPOSED THERE ARE NO MAJOR INTERIOR RENOVATION PROPOSED (FINISH UPDATES / REPAIR ONLY) SOUTH MOB D PARKING GARAGE BOILER HOUSE ENGINEERING FACILITIES BUILDING Seal: CENTRAL BUILDING PARKING GARAGE CHILLER HOUSE MAIN LOBBY ROSENGARTEN BUILDING INSTITUTE FOR MEDICAL RESEARCH RECIEVING CATCH BASIN PEW BUILDING MRI CENTER Revision/ Date N FRIENDS CENTRAL SCHOOL 04/16/14 Comments ISSUED FOR BID E COVER SHEET CAMPUS MAP LOCATION PLAN CS-1 Date: 04.16.14 Proj.No: 1413A k:\voltaix\0814b-voltaix headquarters\revit files\central file\0814b central file.rvt 1 2 3 4 5 A TYP 6 A200 1 4 1 SCOPE OF WORK 5 15' - 0" WEST MOB 4 B TYP 6 A200 4 2 2 A200 8 EAST MOB TYP 7 TYP 7 3 LANKENAU HOSPITAL TYP 6 100 EAST LANCASTER AVENUE WYNNEWOOD, PA 19096 C 3 WEST MOB WINDOW REPLACEMENT A200 SOUTH ANNEX PARKING GARAGE - NOT IN SCOPE ATRIUM A201 1 TYP 7 SOUTH MOB NOT IN SCOPE Seal: D CENTRAL BUILDING - NOT IN SCOPE Revision/ Date E SHEET NOTES x 1) ALL INTERIOR WORK SHOULD BE CLOSELY COORDINATED WITH MLHS. MLHS WILL PROVIDE ALL NECESSARY WORKERS SECURE ACCESS BADGES AND WILL BE REQUIRED TO OPERATE AND ABIDE BY ALL MLHS IMPOSED RULES /REGULATIONS 1 SCOPE OF WORK (DASHED): • WEST MOB (N, S, E, & W FACADES; EXCLUDES GROUND FLOOR) • SOUTH ANNEX (WEST FACADE; ALL FLOORS 2) SEE SHEET A/200 FOR WINDOW REPLACEMENT SCOPE FOR WEST MOB 2 PROPOSED LOCATION FOR CONSTRUCTION TRAILERS (SUBJECT TO CHANGE) 3) SEE SHEET A/201 FOR WINDOW REPLACEMENT SCOPE FOR SOUTH ANNEX 3 CONSTRUCTION PERSONEL BASEMENT ENTRANCE (SECURE) - SEE A/200 4) SEE A/300 FOR FLOOR PLANS 4 GATED ENTRANCE TO CONSTRUCTION STAGING 5) CONTRACTOR PARKING WILL BE PROVIDED IN DESIGNATED PARKING GARAGE "D" (SEE CAMPUS PLAN ON CS-1) 5 CONSTRUCTION STAGING / MATERIAL LAYDOWN - DOTTED 6 FENCING AROUND CONSTRUCTION STAGING AREA (OPAQUE) 7 LIMIT OF SITE DISTURBANCE (5 FT FROM FACE OF BUILDING) - HATCH 8 KEY NOTES AREA FENCED & CLOSED TO PUBLIC ACCESS DURING CONSTRUCTION 04/16/14 Comments ISSUED FOR BID ARCHITECTURAL SITE PLAN 1 SITE PLAN 1" = 20'-0" A001 Date: 04.16.14 Proj.No: 1413A k:\voltaix\0814b-voltaix headquarters\revit files\central file\0814b central file.rvt 1 2 D C 24' - 9" 3 B 25' - 0" 9 A 24' - 9" 4 26' - 3" 7 26' - 0" 5 5 26' - 0" 3 2 26' - 0" 26' - 3" 1 SOUTH ANNEX 3 2 3 2 2 2 2 TYP TYP 22' - 0" (V.I.F) 4 3 2 3 2 2 2 2 10' - 6" 4' - 0" 3 24' - 0" (V.I.F.) 4 4' - 0" 4TH FLOOR 298' - 0" 4' - 0" 3 11' - 4" T.O ROOF SLAB 309' - 4" 4' - 0" T.O PARAPET 313' - 0" 3' - 8" A 3 A400 3 3 3 3 3 2 2 2 2 2 2 2 2 2 4' - 0" 10' - 6" 4' - 0" 10' - 6" 2ND FLOOR 277' - 0" B 2 4' - 0" 3 4' - 0" 3RD FLOOR 287' - 6" TYP TYP 4 4 1ST FLOOR 266' - 6" 1 1 1 1 1 1 1 12' - 6" 1 10' - 6" GROUND FLOOR 254' - 0" WEST MOB / SOUTH ANNEX CONNECTOR (N.I.C.) BASEMENT 243' - 6" 1 NORTH ELEVATION - WEST MOB 1/8" = 1'-0" A B 24' - 9" EAST ELEVATION - WEST MOB 2 C 25' - 0" 24' - 9" 1/8" = 1'-0" 1 D 26' - 3" 2 26' - 0" 3 26' - 0" 5 26' - 0" 7 26' - 3" LANKENAU HOSPITAL 9 100 EAST LANCASTER AVENUE WYNNEWOOD, PA 19096 SOUTH ANNEX 6' - 0" V.I.F 7'-0" V.I.F 11' - 4" T.O ROOF SLAB 309' - 4" 5 2 2 2 2 2 2 2 2 2 2 2 2 2 TYP 4 5 4' - 0" 4TH FLOOR 298' - 0" 10' - 6" 2 WEST MOB WINDOW REPLACEMENT 4' - 0" T.O PARAPET 313' - 0" 3' - 8" C 24' - 0" (V.I.F.) 3 3RD FLOOR 287' - 6" 2 Seal: 4' - 0" 10' - 6" 5 2ND FLOOR 277' - 0" 5 2 2 2 2 4' - 0" 2 10' - 6" D A400 TYP 4 1ST FLOOR 266' - 6" 1 1 1 1 1 12' - 6" CONNECTOR TO SOUTH ANNEX 10' - 6" GROUND FLOOR 254' - 0" WEST MOB / SOUTH ANNEX CONNECTOR (N.I.C.) 8 BASEMENT 243' - 6" 3 E SOUTH ELEVATION - WEST MOB 1/8" = 1'-0" SHEET NOTES x 1) 1 EXISTING GROUND FLOOR WINDOWS (RECENTLY REPLACED) TO REMAIN (N.I.C.) 2 NEW INSULATED 4FT x 24FT WINDOWS TO REPLACE EXISTING (REMOVED) 3 NEW INSULATED 4FT x 22FT WINDOWS TO REPLACE EXISTING (REMOVED) SCOPE OF WINDOW REPLACEMENT INCLUDES (BUT IS NOT LIMITED TO): • REMOVAL OF EXISTING WINDOW AND REQUIRED INTERIOR FINISHES (SEE A/400 FOR SCOPE OF INTERIOR DEMOLITION) • INSTALLATION OF NEW INSULATED FRAME / GLAZING AND ROLLING SHADES • INSTALLATION OF NEW SOLID SURFACE SILL AND PARTITION CLOSURE • VARIOUS CEILING / PARTION REPAIR KEY NOTES 4 OPERABLE WINDOW VENT - BID ALTERNATE No. 2 WINDOW REPLACEMENT SCOPE FOR WEST MOB INCLUDES ONLY FLOORS 1-4 (GROUND FLOOR IS TO REMAIN UNDISTURBED) 5 NEW INSULATED 6FT x 7FT WINDOWS TO REPLACE EXISTING (REMOVED) 3) SEE SHEET A/201 FOR SCOPE OF WORK FOR SOUTH ANNEX 6 NEW INSULATED 60in HIGH WINDOWS (SOUTH ANNEX) TO REPLACE EXISTING 4) SEE SITE PLAN (SHEET A/001) FOR CONSTRUCTION ACCESS / STAGING LOCATIONS 7 NEW INSULATED 48in HIGH WINDOWS (SOUTH ANNEX) TO REPLACE EXISTING 8 SECURE CONSTRUCTION ENTRANCE (WEST MOB BASEMENT LEVEL) 2) NOTE: ALL DIMENSIONS ARE ASSUMED AND SHOULD BE VERIFIED IN FIELD PRIOR TO MATERIAL PURCHASE 4 WEST ELEVATION - WEST MOB 1/8" = 1'-0" Revision/ Date 04/16/14 Comments ISSUED FOR BID BUILDING ELEVATIONS A200 Date: 04.16.14 Proj.No: 1413A k:\voltaix\0814b-voltaix headquarters\revit files\central file\0814b central file.rvt 1 2 7a 6a 3 5a 4a 4 5 3a 24' - 0" 24' - 0" 24' - 0" 24' - 0" 6 6 6 6 WEST MOB 11' - 4" T.O ROOF SLAB 309' - 4" 5' - 0" VIF T.O PARAPET 313' - 0" 3' - 8" A TYP 22'-9" (V.I.F) 4 6 6 6 6 7 7 7 7 7 7 7 7 10' - 6" 5' - 0" VIF 4TH FLOOR 298' - 0" 7 3RD FLOOR 287' - 6" 10' - 6" 4' - 4" VIF A400 10' - 6" 4' - 4" VIF 2ND FLOOR 277' - 0" TYP B 4 1ST FLOOR 266' - 6" 7 7 7 12' - 6" 4' - 4" VIF 7 GROUND FLOOR 254' - 0" WEST MOB / SOUTH ANNEX CONNECTOR (N.I.C.) 1 WEST ELEVATION - SOUTH ANNEX 1/8" = 1'-0" LANKENAU HOSPITAL 100 EAST LANCASTER AVENUE WYNNEWOOD, PA 19096 C WEST MOB WINDOW REPLACEMENT Seal: D Revision/ Date E SHEET NOTES x 1) 1 EXISTING GROUND FLOOR WINDOWS (RECENTLY REPLACED) TO REMAIN 2 NEW INSULATED 4FT x 24FT WINDOWS TO REPLACE EXISTING (REMOVED) 3 NEW INSULATED 4FT x 22FT WINDOWS TO REPLACE EXISTING (REMOVED) SCOPE OF WINDOW REPLACEMENT INCLUDES (BUT IS NOT LIMITED TO): • REMOVAL OF EXISTING WINDOW AND REQUIRED INTERIOR FINISHES (SEE A/400 FOR SCOPE OF INTERIOR DEMOLITION) • INSTALLATION OF NEW INSULATED FRAME / GLAZING AND ROLLING SHADES • INSTALLATION OF NEW SOLID SURFACE SILL AND PARTITION CLOSURE • VARIOUS CEILING / PARTION REPAIR KEY NOTES 4 OPERABLE WINDOW VENT - BID ALTERNATE No. 2 WINDOW REPLACEMENT SCOPE FOR SOUTH INCLUDES ONLY WINDOWS ON THE WEST FACADE (WINDOWS ON ALL FLOORS TO BE REPLACED) 5 NEW INSULATED 6FT x 7FT WINDOWS TO REPLACE EXISTING (REMOVED) 3) SEE SHEET A/200 FOR SCOPE OF WORK FOR WEST MOB 6 NEW INSULATED 60in HIGH WINDOWS (SOUTH ANNEX) TO REPLACE EXISTING 4) SEE SITE PLAN (SHEET A/001) FOR CONSTRUCTION ACCESS / STAGING LOCATIONS 7 NEW INSULATED 48in HIGH WINDOWS (SOUTH ANNEX) TO REPLACE EXISTING 8 SECURE CONSTRUCTION ENTRANCE (WEST MOB BASEMENT LEVEL) 2) NOTE: ALL DIMENSIONS ARE ASSUMED AND SHOULD BE VERIFIED IN FIELD PRIOR TO MATERIAL PURCHASE 04/16/14 Comments ISSUED FOR BID BUILDING ELEVATIONS A201 Date: 04.16.14 Proj.No: 1413A k:\voltaix\0814b-voltaix headquarters\revit files\central file\0814b central file.rvt 1 2 3 4 5 A200 1 A B C D GROUND FLOOR OF WEST MOB - NOT IN PROJECT SCOPE 1 1 2 1 2 1 1 2 2 1 2 2 1 1 1 1 A 1 1 1 1 1 1 1 1 1 1 1 1 2 2 1 1 1 2 2 1 2 1 2 1 3 DN UP DN UP DN DN UP 1 1 A200 4 2 A200 1 1 1 1 1 1 1 A IG L N 1 1 5 A IG L N 2 1 1 1 1 1 1 2 2 1 1 1 7 B 1 1 1 2 1 9 2 1 1 2 DN 7a 1 1 1 1 2 1 1 1 1 1 2 1 6a 8 0 . 0 A G L I N 1 A201 1 LANKENAU HOSPITAL 100 EAST LANCASTER AVENUE WYNNEWOOD, PA 19096 5a C 1 1 A G L I N 1 1 1 WEST MOB WINDOW REPLACEMENT 1 4a 2 A G L I N 1 1 1 1 1 1 2 3a NOTE: PARTITION / GLAZING INTERSECTION TYPES AND QUANTITIES SHOWN WERE DERIVED FROM THE FLOOR PLANS GIVEN AND SURVEY PERFORMED ONSITE. THESE CONDITIONS ARE DOCUMENTED CORRECTLY TO BE BEST OF OUR KNOWLEDGE. THERE MAY BE A FEW INSTANCES HOWEVER, WHERE PARTITION LOCATION, GLAZING INTERSECTION TYPE, QUANTITIES, ETC. VARY FROM WHAT IS SHOWN. PLEASE ALLOW FOR SLIGHT DIFFERENCES BETWEEN CONDITIONS SHOWN AND THOSE FOUND IN FIELD. Seal: - THIS NOTE APPLIES TO ALL FLOORS (BOTH WEST MOB AND SOUTH ANNEX) 1 GROUND FLOOR PLAN 2 1/16" = 1'-0" 1ST FLOOR PLAN 3 1/16" = 1'-0" 2ND FLOOR 4 1/16" = 1'-0" 3RD FLOOR 5 1/16" = 1'-0" 4TH FLOOR 1/16" = 1'-0" D * DISTANCE OF PARTITION IN RELATION TO WINDOW MULLION (AND AMOUNT OF SILL OVERLAP) WILL VARY @ EACH PARTITION / WINDOW INTERSECTION. * DISTANCE OF PARTITION IN RELATION TO WINDOW MULLION (AND AMOUNT OF SILL OVERLAP) WILL VARY @ EACH PARTITION / WINDOW INTERSECTION. ADDITIONAL STUD FRAMING WILL MORE THAN LIKELY BE REQUIRED @ PARTITION TERMINATION *** CERTAIN PARTITIONS MAY NOT OVERLAP INTERIOR SILL. IF THIS IS THE CASE, FINISH PARTITION AS CLOSE TO WINDOW FRAME AS POSSIBLE AND USE APPROPRIATE ALUMINUM CLOSURE SIZE TO BRIDGE THIS EXPANDED DISTANCE ** PARITION LOCATION IN RELATIONSHIP TO THE CENTERLINE OF WINDOW MULLION WILL VARY @ EACH PARTITION / WINDOW INTERSECTION. ** PARITION LOCATION IN RELATIONSHIP TO THE CENTERLINE OF WINDOW MULLION WILL VARY @ EACH PARTITION / WINDOW INTERSECTION. ADD ADDITIONAL ACOUSTICAL BATT INSULATION INSIDE MULLION MATE TO MAXIMIZE ACOUSTICAL ISOLATION ** VARIES (V.I.F) ALUM. CHANNEL STANDARD 4 7/8" PARTITION ADJUSTABLE EXTRUDED ALUMINUM PARTITION CLOSURE - "GORDON" MULLION MATE PARTITION TO MULLION CLOSURE (ACTUAL CONSTRUCTION MAY VARY) VARIES (V.I.F) 2" INSULATION 5" * * * * STEEL PANEL EXTRUDED ALUMINUM CLOSER TRACK (BY MANUFACTURER) PROVIDE NEW GWB, AND S.S. CORNER GUARD TO PROVIDE FINISHED SURFACE FOR EXTRUDED ALUMINUM CLOSURE ADJUSTABLE EXTRUDED ALUMINUM PARTITION CLOSURE "GORDON" MULLION MATE 4 1/2" PARTITION TO MULLION CLOSURE (ACTUAL CONSTRUCTION MAY VARY) VARIES (V.I.F) ** VARIES ** * * ** VARIES (V.I.F) VARIES (V.I.F) * 1" ADDITIONAL STUD FRAMING WILL MORE THAN LIKELY BE REQUIRED @ PARTITION TERMINATION PROVIDE FULL PERIMETER SILICONE SEALANT MATCHING CLEAR ALUMINUM FINISH FOR ACOUSTICAL ISOLATION. VARIES STANDARD 4 7/8" PARTITION NEW 4 1/2" DEEP WINDOW FRAMING NEW 4 1/2" DEEP WINDOW FRAMING Revision/ Date 04/16/14 Comments ISSUED FOR BID E PLANS / DETAILS THIS CONDITION OCCURS IN SOUTH ANNEX ONLY NOTE: EXISTING PARTITION DETAILS ARE A PROVIDED TO ILLUSTRATE THE VARIOUS CONDITIONS ON HOW EXISTING PARTITIONS CLOSE AT THE WINDOW MULLIONS. WHILE WE BELIEVE THESE DETAILS ARE REASONABLY ACCURATE, VARIATIONS WILL OCCUR IN ACTUAL CONSTRUCTION AND DIMENSIONING. 6 TYPICAL PARTITION @ MULLION - 'TYPE 1' 3" = 1'-0" * (SEE NOTE ON DETAIL 6/A300) 1 7 TYPICAL PARTITION @ MULLION - 'TYPE 2' 3" = 1'-0" 2 8 NEW PARTITION CLOSURE DETAIL - 'TYPE 1' 3" = 1'-0" 9 NEW PARTITION CLOSURE DETAIL 'TYPE 2' 3" = 1'-0" A300 Date: 04.16.14 Proj.No: 1413A k:\voltaix\0814b-voltaix headquarters\revit files\central file\0814b central file.rvt 1 2 3 4 5 A TREATED BLOCKING ANCHORED TO CONCRETE BACKUP 1/4" MIN. SHIM SPACE, BACKER ROD AND SEALANT TWO-PIECE "KAWNEER" STANDARD COMPENSATING HEAD RECEPTOR 4" NOM. STANDARD FACEBRICK REMOVED EXISTING METAL ANCHOR CLIP "KAWNEER" TRIFAB 451T FRONT GLAZED FRAMING SYSTEM BENT METAlL ANCHOR CLIP REMOVE EXISTING WINDOW FRAME AND GLAZING PORTION OF NEW GWB CEILING RETURNING AND RUNNING UNDER HEAD RECEPTOR REMOVE WINDOW SHADES AND CEILING TRACK CEILING TRACK FOR WINDOW SHADING REMOVE PORTION OF GWB SOFFIT TO EXPOSE FRAME ANCHORS. REMOVAL OF ENTIRE GWB SOFFIT IS ALLOWABLE. ALMINUM SILL FLASHING ROLLER-SHADE FASTENED TO FRAMING SYSTEM BID ALTERNATE No. 1. 48" 2" DEEP ALUMINUM WINDOW FRAME DOUBLE ANGLES MAINTAIN (IF POSSIBLE) EXISTING GWB FINISH STUD FRAMING AND GWB FINISH ASSESS CONDITION OF STUD BACKUP AND INSULATION; MAINTAIN IF AT ALL POSSIBLE RIGID INSULATION @ CAVITY BREAK METAL SILL FLASHING STANDARD 4" NOM. FACEBRICK BENT METAL ANCHOR CLIPS CONCRETE STRUCTURE WITHIN REMOVE EXISTING SILL FLASHING AND ALL FASTENERS REMOVE EXISTING DOUBLE ANGLES REMOVE ALL METAL FRAME ANCHORS TWO-PIECE "KAWNEER" STANDARD COMPENSATING RECEPTOR BACKER ROD AND SEALANT "KAWNEER" HIGH PERFORMANCE SILL EXTRUSION 4 1/2" STEEL CLIPS ANCHORED TO CMU @ 18" oc; BLOCKING 3/4" SOLID-SURFACE SILL 2 5/8" EXISTING (CONTINUOUS) RIGID INSULATION AND STUD FRAMING 4 1/2" 1 1/2" 3 7/8" GWB FINISH WOOD BLOCKING AND SEALANT OVER EXISTING GWB FINISH 6" REMOVE EXISTING SOLID WOOD SILL 3/4" SOLID WOOD WINDOW SILL "KAWNEER" TRIFAB 451T FRONT GLAZED FRAMING SYSTEM 2 1/8" 2 1/8" 2" DEEP ALUMINUM WINDOW FRAMING - 1/4" GLAZING 1/2" GWB CEILING SOFFIT 48" STEEL SHELF ANGLE ANCHOR BOLTED TO CONCRETE STRUCTURE 2" 3/4" B 1/2" (EXTEND FLASHING BENEATH SILL EXTRUSION, SEAL) MASTIC 2" 7 1/4" RETAINER CLIP 12 GA BREAK METAL FLASHING JAMB DETAIL JAMB DETAIL JAMB DETAIL 1 EXISTING WEST MOB WINDOW CONDITION 2 3" = 1'-0" TYPICAL WEST MOB WINDOW DEMOLITION 3 3" = 1'-0" NEW WEST MOB WINDOW INSTALLATION 3" = 1'-0" LANKENAU HOSPITAL 100 EAST LANCASTER AVENUE WYNNEWOOD, PA 19096 C WEST MOB WINDOW REPLACEMENT COPPER FLASHING TREATED BLOCKING ANCHORED TO CONCRETE BACKUP REMOVE EXISTING WOOD BLOCKING AND WINDOW SHADE TRACK 1/4" MIN. SHIM SPACE, BACKER ROD AND SEALANT 4" NOM. FACEBRICK REMOVE EXISTING METAL ANGLE, COPPER FLASHING, AND FASTENING CLIP STEEL SHELF ANGLE ANCHOR BOLTED TO CONCRETE STRUCTURE REMOVE PORTION OF EXISTING ACT CEILING REMOVE ENOUGH TO ALLOW FOR THE REMOVAL OF BLOCKING AND ALL WINDOW FRAME ANCHORING - HOLD CEILING PANELS FOR REINSTALLATION. TWO-PIECE "KAWNEER" STANDARD COMPENSATING RECEPTOR REMOVE WINDOW FRAME, GLAZING, TRACKSYSTEM, AND SPRING CLIP AT WINDOW FRAME, SAWCUT WINDOW TRACK SYSTEM / SILL FLASHING AND BLOCKING DOWN TO FACE OF BRICK BELOW. BACKER ROD AND SEALANT 2 5/8" "KAWNEER" HIGH PERFORMANCE SILL EXTRUSION REMOVE COPPER FLASHING SOLID-SURFACE SILL INSTALLED OVER EXISTING STEEL SILL EXISTING GROUT FILLED STEEL (INTERIOR) SILL TO REMAIN 4" NEW TREATED WOOD BLOCKING 3/8" 3" PLASTER FINISH ALUMINUM ANGLE OVER SAWCUT PLASTER EDGE 1 5/8" 1" GROUT FILLED, INTERIOR STEEL SILL LEAD COATED COPPER FLASHING 1 3/4" WOOD BLOCKING NOTE: ACTUAL CEILING CONDITION MAY VARY (THERE ARE SOFFITS ON SOME FLOORS); HOWEVER, THE INTENT REMAINS THE SAME - REMOVE ONLY WHAT IS NECESSARY AND REINSTALL ONCE NEW WINDOWS HAVE BEEN INSTALLED 2 1/8" 3/8" ALUMINUM WINDOW SILL FRAMING ALUM. CLIP WELDED TO WINDOW FRAME AND CONTINUOUS ANGLE "KAWNEER" TRIFAB 451T FRONT GLAZED FRAMING SYSTEM ROLLER-SHADE FASTENED TO FRAMING SYSTEM BID ALTERNATE No. 1 1/2" ALUM. WINDOW FRAME / TRACK SYSTEM, ALUM. SPRING CLIP 2 1/8" REPLACE ACT CEILING AS REQUIRED. PROVIDE 1/4" FINISHED HARD BOARD CLOSURE @ FRAME HEAD 3/4" 4' - 4 3/8" VARIES (V.I.F) WINDOW SHADE TRACK "KAWNEER" TRIFAB 451T FRONT GLAZED FRAMING SYSTEM 1/4" ALUMINUM WINDOW FRAME, TRACK SYSTEM, AND GLAZING WOOD BLOCKING AND WELDED ALUMINUM CLIP D Seal: REMOVE EXISTING WINDOW FRAME, GLAZING, AND ASSOCIATED TRACK SYSTEM COPPER FLASHING AND CONTINUOUS ALUM. ANGLE ACT CEILING TWO-PIECE "KAWNEER" STANDARD COMPENSATING HEAD RECEPTOR 4 1/2" PROVIDE CLEAN SAWCUT OF PLASTER FINISH AND BLOCKING TO REMOVE ALUM. ANCHOR CLIP AND ANGLE AND ALLOW FOR CLEAN INSTALLATION OF NEW WINDOW FRAME 12 GA BREAK METAL FLASHING (EXTEND FLASHING BENEATH SILL EXTRUSION, SEAL) FILL CAVITY BENEATH FLASHING WITH RIGID INSULATION 1/2" 4 1/8" 3/4" WOOD BLOCKING Revision/ Date Comments PLASTER FINISH 04/16/14 E JAMB DETAIL 4 EXISTING SOUTH ANNEX WINDOW CONDITION 3" = 1'-0" JAMB DETAIL JAMB DETAIL 6 TYPICAL SOUTH ANNEX WINDOW DEMOLITION 3" = 1'-0" ISSUED FOR BID 7 NEW SOUTH ANNEX WINDOW INSTALLATION 3" = 1'-0" WINDOW DETAILS A400 Date: 04.16.14 Proj.No: 1413A k:\voltaix\0814b-voltaix headquarters\revit files\central file\0814b central file.rvt
© Copyright 2024 ExpyDoc