Technical Data Sheet - Non return valves - R1

NON RETURN VALVES
NON RETURN VALVES
Inta’s spring loaded non return valves are used to control the water flow in
one direction and to prevent backflow of the water. In the event of back pressure
the non return valve seal sits inside the housing eliminating the risk of backflow.
spring loaded
low noise
single non return valve
Prevents cross-flow
Controls water flow direction
Low noise
Soft seat
Complete range of double check valves also available
Product Range
female x female non return valves
Description
Single non return valve ½" FxF connection
Single non return valve 3/4" FxF connection
Single non return valve 1" FxF connection
Code
£228.75
NRV0860050
£228.75
NRV0860075
£228.75
NRV0860100
Single non return valve 1 1/4" FxF connection
NRV0860125
£228.75
Single non return valve 1 1/2" FxF connection
NRV0860150
£228.75
Single non return valve 2" FxF connection
£228.75
NRV0860200
Single non return valve 2 1/2" FxF connection
£228.75
NRV3082250
Single non return valve 3" FxF connection
£228.75
NRV3082300
Single non return valve 4" FxF connection
NRV3082400
male x female non return valves
Description
Single non return valve ½" MxF connection
Single non return valve 3/4" MxF connection
Single non return valve 1" MxF connection
Code
£228.75
NRV0860050MF
NRV0860075MF
£228.75
£228.75
NRV0860100MF
Single non return valve 1 1/4" MxF connection
NRV0860125MF
Single non return valve 1 1/2" MxF connection
NRV0860150MF
Single non return valve 2" MxF connection
NRV0860200MF
£228.75
Single non return valve 2 1/2" MxF connection
NRV3082250MF
Single non return valve 3" MxF connection
NRV3082300MF
£228.75
Single non return valve 4" MxF connection
NRV3082400MF
NON RETURN VALVES
NON RETURN VALVES
Dimensions and Kv values
Kv
3,11
6,39
ØA
1/2"
3/4"
B
34.5
40.5
C
49
57
10,11
1"
48.5
68
16,67
1 1/4"
58.5
70
24,62
38,84
-
1 1/2"
2"
2 1/2"
68.5
85
75
81
-
3"
4"
101
110
154
91
105
118
Technical Specification
Max pressure (static)
15 bar
Min operating pressure (dynamic)
0.04 bar
Operating temperature (water)
0 to 90°C
Operating temperature (air)
-20 to 110°C
Flow rate and Pressure Drop
1/2"
3/4"
1"1/4
1"
1"1/2
2"
10.000
Pressure drop (DP)
1 daPa = 1,02 mmH20
1.000
100
flow rate l/h
E&OE
03/2014
flow rate m3/h
300
200
100
10.000
1.000
100
10