to download A12.1 thru A12.2

32
A12.1
3"
8 1/2"
3"
1' - 9"
3"
3"
1' - 9"
SYNTHETIC STONE
COUNTER OVER 3/4"
SUBSTRATE
SYNTHETIC
STONE
COUNTER AND
BACKSPLASH
SYNTHETIC
STONE
TRANSACTION
COUNTER
BEYOND (QTZ-1)
SYNTHETIC STONE
COUNTER OVER 3/4"
SUBSTRATE (QTZ-3)
2' - 10"
2' - 0"
4"
4"
SYNTHETIC
STONE
COUNTER AND
BACKSPLASH
RETURN COUNTER
MATERIAL TO WALL. TYP
8 1/2"
SYNTHETIC STONE
TRANSACTION EDGE
SIM
21
A12.1
2X WOOD BLOCKING
2' - 11 1/2"
33
A12.1
4"
1 1/2"
SYNTHETIC STONE
TRANSACTION EDGE
OH
4"
1 1/2"
4"
8 1/2"
1 1/2"
1 1/2"
2 1/2"
1 1/2"
35
A12.1
4"
2' - 11 1/2"
1' - 2 1/2"
SYNTHETIC STONE
TRANSACTION LEDGE
RE: SCHED
3/4" SUBSTRATE
43
A12.1
10"
SYNTHETIC STONE
TRANSACTION
COUNTER BEYOND
2' - 10"
2' - 0"
10"
1 1/2"
1 1/2"
3"
CONT. BEAD SEALANT
PLYWOOD
BACKING PANELS
TOP/BOTTOM OF
SUPPORT
BRACKETS
ADHERED FILM VENEER
(AF-01)
18"x18" ALUM
COUNTER BRACKET
@ 36" MAX OC. TYP.
FRAMING AND
GYP BOARD
PER WALL
TYPE/SCHED
3/8" BY 4" QTZ BASE
MATCH QTZ-1
PLAM VENEER OVER
APPROVED
SUBSTRATE
(HPL-1)
PLAM CABINET
FACE BEYOND
18"x18" ALUM
COUNTER BRACKET
@ 36" MAX OC. TYP.
1" DEEP SIDE TOE
KICK BEYOND TYP. @
CABINET ENDS
5/8" GYP BOARD
1" DEEP SIDE TOE
KICK BEYOND. TYP @
CABINET ENDS
5/8" GYP BOARD
BASE PER SCHED
BASE PER SCHED
BASE PER SCHED
4"
FRAMING AND
GYP BOARD
PER WALL
TYPE/SCHED
2' - 10"
PLAM CABINET
FACE BEYOND
2' - 6"
FACE OF COUNTER
RETURN TO FLOOR
BEYOND. EA SIDE. TYP.
PLAM VENEER
OVER APPROVED
SUBSTRATE
(HPL-1)
2' - 3" CLR. MIN.
2' - 10"
3' - 2"
2X 3 5/8" MTL
STUDS @ 16" O.C.
2' - 6"
PLYWOOD
BACKING PANELS
TOP/BOTTOM OF
SUPPORT
BRACKETS
5/8" HIGH ABUSE
GYP BOARD
CONSULTANTS
RECEPTION TRANSACTION LEDGE
A12.1
RECEPTION DESK WORK SURFACE
22
A12.1
SCALE: 1 1/2" = 1'-0"
CONCESSION WORK COUNTER
23
A12.1
SCALE: 1 1/2" = 1'-0"
RECEPTION WORK SURFACE
24
A12.1
SCALE: 1 1/2" = 1'-0"
25
A12.1
SCALE: 1 1/2" = 1'-0"
CONCESSION WORK SURFACE
Structural:
TOTH AND ASSOCIATES, INC
830 East Primrose Suite 200
Springfield, MO 65807
SCALE: 1 1/2" = 1'-0"
1' - 2 1/2"
1X HANGER RAILS. 3 MIN
SYNTHETIC STONE
TRANSACTION LEDGE
RE: SCHED
3/4" SUBSTRATE
PLAM TOP PANEL
1 1/2"
8 1/2"
1 1/2"
1 1/2"
Mechanical, Electrical, Plumbing:
KUCIREK ENGINEERING, INC
7587 Main Street
Omaha, NE 68127
2 1/2"4"
(5) 3/4" PLAM ADJUSTABLE SHELVES
1 1/2"
1 1/2"
21
Civil:
KOEHLER ENGINEERING AND LAND
SURVEYING INC.
194 Coker Lane
Cape Girardeau, MO 63701
3"
4"
RECEPTION BASE CABINET
SCALE: 1 1/2" = 1'-0"
1 1/2"
3/8" BY 4" QTZ BASE
MATCH QTZ-1
5/8" GYP BOARD
BASE PER SCHED
5 1/2"
1' - 6 1/2"
RECEPTION BASE CABINET
35
A12.1
SCALE: 1 1/2" = 1'-0"
PUBLIC FACE
CONCESSION TRANSACTION LEDGE
SCALE: 1 1/2" = 1'-0"
ALUM. COUNTER
BRACKET @ 3'
O.C. MAX.
PENCIL DRAWER
1' - 11"
1 1/2"
SYNTHETIC STONE
COUNTER OVER
SUBSTRATE
11"
LIMIT OF LIABILITY
CABINET FRAME
PLAM VENEER
OVER APPROVED
SUBSTRATE
PLAM BACK
PANELS
FILE DRAWER
PLAM SIDE AND END
PANELS
MTL WALL FRAMING
AND GYP BOARD PER
WALL TYPE/SCHED
CABINET BASE
W/ TOE KICK
BASE PER
SCHEDULE
BASE PER
SCHEDULE
3"
3/4" PLAM SHELF
PLAM SIDE AND
END PANELS
CABINET BASE
W/ TOE KICK
5/8" GYP BOARD
BASE PER SCHED
3"
CABINET BASE W/ TOE KICK
THE DESIGNS INCLUDED HEREIN ARE BASED ON EXTENSIVE RESEARCH
OF THE CAUSES AND EFFECTS OF WINDSTORM DAMAGE TO BUILDINGS.
SHELTERS DESIGNED AND BUILT TO THESE STANDARDS SHOULD
PROVIDE A HIGH DEGREE OF OCCUPANT PROTECTION DURING
TORNADOES. ANY SUBSTITUTION OF EITHER MATERIALS OR DESIGN
CONCEPTS MAY DECREASE THE LEVEL OF OCCUPANT PROTECTION
AND/OR INCREASE THE POSSIBILITY OF PERSONAL INJURY DURING A
SEVERE WIND EVENT.
BECAUSE IT IS NOT POSSIBLE TO PREDICT OR TEST ALL CONDITIONS
THAT MAY OCCUR DURING SEVERE WINDSTORMS, OR CONTROL THE
QUALITY OF CONSTRUCTION, AMONG OTHER THINGS, THE DESIGNER
DOES NOT WARRANT THE DESIGN.
1' - 6 1/2"
2' - 7"
UNDER LAVATORY
GUARD, TYP. @
EACH
5/8" MOISTURE
RESISTANT GYP BDPAINT
3/4" PLAM DRAWER
FRONTS
SYNTHETIC STONE
COUNTER OVER 3/4"
PLYWOOD SUBSTRATE
PLAM DRAWER
FACE AND DOOR
5 5/8" 1/2"
3/4" SYNTHETIC STONE
BACKSPLASH AND
ENDSPLASHES
CABINET FRAME
PLAM @
EXPOSED FRONT,
TYP.
SINK BEYOND,
RE: PLUMBING
3"
MORTAR
GLASS WALL TILE
PLAM SIDE AND
END PANELS
CABINET BASE
W/ TOE KICK
WORK FACE
2' - 0"
1 1/2"
3"
QTZ COUNTER
APRON
2x BLOCKING
WALL FRAMING
PER WALL TYPES
CONCRETE
BACKER BOARD
PLAM VENEER OVER
APPROVED
SUBSTRATE
MIRROR, RE:
ELEVATIONS
QTZ COUNTER,
BACKSPLASH, AND
END SPLASH
3/4" COUNTER
SUBSTRATE
CONT SEALANT
BEAD. TYP
WOOD BLOCKING
@ BRACKET
SUPPORTS
34
A12.1
4"
1/2" PLAM BACK
PANEL
SCALE: 1 1/2" = 1'-0"
5 5/8" 1/2"
2' - 1"
2X 3 5/8" MTL
STUDS @ 16" O.C.
BASE PER SCHED
1' - 6 1/2"
PLYWOOD BACKING
PANELS AS REQ'D
5/8" HIGH ABUSE
GYP BOARD
CABINET FRAME
PLAM @ EXPOSED
FRONT, TYP.
3"
CONCESSION/MTG BASE CABINET
33
A12.1
PENCIL DRAWER
3"
BASE PER
SCHED
CONT. BEAD SEALANT
THE DESIGNER NEITHER MANUFACTURERS NOR SELLS SHELTERS
BUILT FROM THE DESIGN. THE DESIGNERS HAVE NOT MADE AND DO
NOT MAKE ANY REPRESENTATION, WARRANTY, OR COVENANT,
EXPRESSED OR IMPLIED, WITH RESPECT TO THE DESIGN, CONDITION,
QUALITY, DURABILITY, OPERATION, FITNESS FOR USE, OR SUITABILITY
OF THE SHELTER OR ANY OTHER PERSON OR ENTITY ARISING OUT OF
OR IN CONNECTION WITH THE USE, CONDITION, AND/OR
PERFORMANCE OF SHELTERS BUILT FROM THIS DESIGN OR FROM THE
MAINTENANCE THEREOF.
JACKSON SAFE ROOM AND COMMUNITY CENTER FEMA-DR-1980-MO PROJECT # 0067
381 E DEERWOOD DRIVE
JACKSON, MO 63755
NOT FOR CONSTRUCTION
BID SET
CABINET BASE
W/ TOE KICK
SYNTHETIC STONE
COUNTER OVER 3/4"
PLYWOOD SUBSTRATE
CASEWORK DETAILS
CABINET BASE
W/ TOE KICK
RETURN COUNTER
MATERIAL TO WALL. TYP
FILE DRAWER
4"
7' - 8"
32
3/4" ADJUSTABLE SHELF
PLAM SIDE AND
END PANELS
BASE PER
SCHEDULE
A12.1
GYP BOARD AND
WALL FRAMING PER
WALL TYPE
PLAM BACK PANEL
PLAM SIDE AND
END PANELS
2X WOOD BLOCKING
10"
FACE OF COUNTER
RETURN TO FLOOR
BEYOND. EA SIDE. TYP.
PENCIL DRAWER
1' - 10 1/2"
3/4" ADJUSTABLE SHELF
ADJUSTABLE
SHELF BRACKET
2' - 6"
1' - 6 1/2"
PLAM BACK PANEL
PLAM DRAWER
FRONTS
2' - 10"
1X HANG RAILS TOP
AND BOTTOM TYP.
PLAM DRAWER
SIDES, BACK, AND
BOTTOM. TYP
GYP BOARD AND
WALL FRAMING PER
WALL TYPE
3/4" PLAM
CABINET DOOR
SYNTHETIC STONE COUNTER
OVER SUBSTRATE
3/4" PLAM DRAWER
FACE AND DOOR
1X HANG RAILS TOP
AND BOTTOM TYP.
WALL FRAMING
AND GYP BD PER
WALL TYPE/
SCHED
2' - 0"
4"
PLAM DRAWER
FACE AND DOOR
5 1/2" 1/2" 1 1/2"
PLAM DRAWER
SIDES, BACK, AND
BOTTOM. TYP
3/4" SYNTHETIC
STONE ENDSPLASH
AND BACKSPLASH
SYNTHETIC STONE
COUNTER OVER
SUBSTRATE
2' - 0"
5 1/2" 1/2"
CONT SEALANT
BEAD. TYP
3' - 2"
2' - 0"
CONT SEALANT
BEAD. TYP
SYNTHETIC STONE
ENDSPLASH AND
BACKSPLASH
iDS Project Number:
Issue Date:
12-108
8/04/2014
BASE PER SCHED
41
A12.1
FULL HEIGHT CABINET
SCALE: 1 1/2" = 1'-0"
42
A12.1
TOILET ROOM COUNTER
SCALE: 1 1/2" = 1'-0"
43
A12.1
RECEPTION BASE CABINET
SCALE: 1 1/2" = 1'-0"
44
A12.1
RECEPTION BASE CABINET
SCALE: 1 1/2" = 1'-0"
A12.1
WALL FRAMING AND GYP BD PER WALL
TYPE & SCHEDULE
PLYWOOD BLOCKING TOP AND BOTTOM
PLAM BACK PANEL
11 1/2"
3/4" SIDE/DIVIDER
PANELS
1 1/2"
8'-0"
8'-0"
HANGER RAILS
TYP TOP AND
BOTTOM
PLAM BACK
2' - 0"
1' - 9"
CONSULTANTS
ADJUSTABLE
SHELF BRACKETS
Civil:
KOEHLER ENGINEERING AND LAND
SURVEYING INC.
194 Coker Lane
Cape Girardeau, MO 63701
1 1/2"
3' - 0"
(2) 3/4" PLAM
ADJUSTABLE
SHELVES
PLAM SIDE AND
BOTTOM PANEL
6"
1' - 0"
2"
Structural:
TOTH AND ASSOCIATES, INC
830 East Primrose Suite 200
Springfield, MO 65807
Mechanical, Electrical, Plumbing:
KUCIREK ENGINEERING, INC
7587 Main Street
Omaha, NE 68127
WALL FRAMING
AND GYP BD PER
WALL TYPE/SCHED
COAT ROD ESCHTCHEON
PLATE BEYOND
PLYWOOD
BLOCKING PANELS
1" COAT ROD
SCALE: 1 1/2" = 1'-0"
STAINLESS STL
COUNTER W/
INTEGRAL
BACKSPLASK
1 1/2"
PLAM COUNTER AND BACKSPLASH
OVER PLYWOOD SUBSTRATE
HANGER RAIL.
TYP TOP/BOTTOM
5 1/2" 1 1/4"
WALL FRAMING AND
GYP TOP PER WALL
TYPE/SCHED
WALL FRAMING AND
GYP BD PER SCHED/
WALL TYPES
CABINET FRAME PLAM
@ EXPOSED FRONT
5 1/2" 1/2"
SST FRAME
4"
CONT. SEALANT BEAD. TYP
4"
CONT. SEALANT
BEAD. TYP.
SCALE: 1 1/2" = 1'-0"
1"
1 1/4"
2' - 0"
UPPER CABINET
PLAM DRAWER/
BOTTOM/ BACK-TYP
ADJ. SHELF BRACKET
SST DOOR/
DOOR FACE
PLAM BACK
PANEL
CABINET BASE
W/ TOE KICK
3"
3"
SST BASE W/ TOE KICKS
34
A12.2
BASE CABINET SST
SCALE: 1 1/2" = 1'-0"
35
A12.2
BASE CABINET
SCALE: 1 1/2" = 1'-0"
LIMIT OF LIABILITY
THE DESIGNS INCLUDED HEREIN ARE BASED ON EXTENSIVE RESEARCH
OF THE CAUSES AND EFFECTS OF WINDSTORM DAMAGE TO BUILDINGS.
SHELTERS DESIGNED AND BUILT TO THESE STANDARDS SHOULD
PROVIDE A HIGH DEGREE OF OCCUPANT PROTECTION DURING
TORNADOES. ANY SUBSTITUTION OF EITHER MATERIALS OR DESIGN
CONCEPTS MAY DECREASE THE LEVEL OF OCCUPANT PROTECTION
AND/OR INCREASE THE POSSIBILITY OF PERSONAL INJURY DURING A
SEVERE WIND EVENT.
BECAUSE IT IS NOT POSSIBLE TO PREDICT OR TEST ALL CONDITIONS
THAT MAY OCCUR DURING SEVERE WINDSTORMS, OR CONTROL THE
QUALITY OF CONSTRUCTION, AMONG OTHER THINGS, THE DESIGNER
DOES NOT WARRANT THE DESIGN.
THE DESIGNER NEITHER MANUFACTURERS NOR SELLS SHELTERS
BUILT FROM THE DESIGN. THE DESIGNERS HAVE NOT MADE AND DO
NOT MAKE ANY REPRESENTATION, WARRANTY, OR COVENANT,
EXPRESSED OR IMPLIED, WITH RESPECT TO THE DESIGN, CONDITION,
QUALITY, DURABILITY, OPERATION, FITNESS FOR USE, OR SUITABILITY
OF THE SHELTER OR ANY OTHER PERSON OR ENTITY ARISING OUT OF
OR IN CONNECTION WITH THE USE, CONDITION, AND/OR
PERFORMANCE OF SHELTERS BUILT FROM THIS DESIGN OR FROM THE
MAINTENANCE THEREOF.
BASE PER
SCHEDULE
CASEWORK DETAILS
PLAM SIDE AND
BOTTOM PANELS
ADJUSTABLE SHELF
HOLES
EXTEND RESINOUS
FLOORING AND BASE
BEHIND/ UNDER
CABINETS
1' - 10 1/2"
SST ADJUSTABLE
SHELF
2' - 10"
1' - 8 1/2"
3/4" PLAM ADJ SHELF
JACKSON SAFE ROOM AND COMMUNITY CENTER FEMA-DR-1980-MO PROJECT # 0067
381 E DEERWOOD DRIVE
JACKSON, MO 63755
BID SET
25
A12.2
4"
UPPER CABINET
24
A12.2
PLAM FRAME
PLAM BOTTOM AND
FRAME
iDS Project Number:
Issue Date:
12-108
8/04/2014
A12.2